Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Characterization of Polyhydroxybutyrate-Based Composites Prepared by Injection Molding

The waste generated by single-use plastics is often non-recyclable and non-biodegradable, inevitably ending up in our landfills, ecosystems, and food chain. Through the introduction of biodegradable polymers as substitutes for common plastics, we can decrease our impact on the planet. In this study, we evaluate the changes in mechanical and thermal properties of polyhydroxybutyrate-based composites with various additives: Microspheres, carbon fibers or polyethylene glycol (2000, 10,000, and 20,000 MW). The mixtures were injection molded using an in-house mold attached to a commercial extruder. The resulting samples were characterized using microscopy and a series of spectroscopic, thermal, and mechanical techniques. We have shown that the addition of carbon fibers and microspheres had minimal impact on thermal stability, whereas polyethylene glycol showed slight improvements at higher molecular weights. All of the composite samples showed a decrease in hardness and compressibility. The findings described in this study will improve our understanding of polyhydroxybutyrate-based composites prepared by injection molding, enabling advancements in integrating biodegradable plastics into everyday products.

36 MATERIALS SCIENCE↗

Ducted Fuel Injection vs. Conventional Diesel Combustion: Extending the Load Range in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) is a technique to attenuate soot formation in compression ignition engines relative to conventional diesel combustion (CDC). The concept is to inject fuel through a small tube inside the combustion chamber to reduce equivalence ratios in the autoignition zone relative to CDC. DFI has been studied at loads as high as 8.5 bar gross indicated mean effective pressure (IMEP g ) and as low as 2.5 bar IMEP g using a four-orifice fuel injector. Across previous studies, DFI has been shown to attenuate soot emissions, increase NO x emissions (at constant charge dilution), and slightly decrease fuel conversion efficiencies for most tested points. This study expands on the previous work by testing 1.1 bar IMEPg (low-load/idle) conditions and 10 bar IMEPg (higher-load) conditions with the same four-orifice fuel injector, as well as examining potential causes of the degradations in NO x emissions and fuel conversion efficiencies. DFI and CDC are directly compared at each operating point in the study. At the low-load condition, the intake charge dilution was swept to elucidate the soot and NO x performance of DFI. The low-load range is important because it is the target of impending, more-stringent emissions regulations, and DFI is shown to be a potentially effective approach for helping to meet these regulations. The results also indicate that DFI likely has slightly decreased fuel conversion efficiencies relative to CDC. We find that the increase in NO x emissions with DFI is likely due to longer charge gas residence times at higher temperatures, which arise from shorter combustion durations and advanced combustion phasing relative to CDC.

42 ENGINEERING↗

Data and figures for "Integrated modeling of boron powder injection for real-time plasma-facing component conditioning"

This dataset contains raw and processed data, as well as supplementary figures used in the paper titled "Integrated modeling of boron powder injection for real-time plasma-facing component conditioning." The data includes simulation results for boron transport and deposition in DIII-D tokamak scenarios, and processed plots. It provides insights into the effects of boron powder injection on plasma-facing component conditioning and surface composition.

ablative particle injection↗

Cost-Benefit Assessment of Additive Manufacturing for Injection Molds

This report presents an additive-manufacturing (AM) technology, where AM Cyclic Olefin Resin (COR) molds would be used for injection molding. The National Laboratory of the Rockies (NLR) team has focused on the costs and economics of this developing technology. This report presents a cost-benefit analysis of using the polySpectra AM COR molds made of COR, at the start of the project (Present') and the potential lifetime, cost-effectiveness, and performance by the end of the project period (Period 3'). The analysis of the AM COR molds is compared to traditional Computer Numerical Control (CNC) machined aluminum molds across the time periods. A cost-benefit model framework has been developed to evaluate AM COR molds. This model accounts for mold delivery to customers, current and future levels of technology readiness, the type of material injected, and various business cases. AM COR molds offer a major advantage in lead time, reducing production setup from weeks or months (with CNC machining) to as little as two to five days. This enables faster prototyping, quicker design cycles, and accelerated time-to-market, critical in industries like electronics, aerospace, medical devices, and automotive. Even modest improvements in the durability of polySpectra AM COR molds show the potential for these molds to complement traditional tooling. With further development, AM COR mold technology could provide significant time and cost savings while supporting increased domestic manufacturing capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Risk-based area of review estimation in overpressured reservoirs to support injection well storage facility permit requirements for CO 2 storage projects

This paper by the Energy & Environmental Research Center presents a workflow and modeling approach for delineating a risk-based area of review (AOR) to support a U.S. Environmental Protection Agency (EPA) Class VI permit for a carbon dioxide (CO 2 ) storage project. The approach combines semianalytical solutions for estimating formation fluid leakage through a hypothetical leaky wellbore with the results of numerical reservoir simulations to define the AOR. The modeling utilizes 1) semianalytical solutions from the peer-reviewed literature for formation fluid leakage through abandoned wellbores by Raven (1990) and Avci (1994), 2) a FORTRAN model compiled and described in Cihan et al. (2011, 2012) called ASLMA (Analytical Solution for Leakage in Multilayered Aquifers), and 3) a computational framework for estimating a risk-based AOR first proposed by Oldenburg et al. (2014, 2016). Therefore, the approach builds upon well-established research and underlying hydrogeological principles that have been upheld for nearly three decades. Moreover, the ASLMA model has been broadly applied to an array of storage projects. The work presented herein extends these earlier works using a custom wrapper written in the software environment, R (R Core Team, 2020), which was developed to perform multiple runs of the ASLMA model using given ranges for one or more input parameters. In addition, the current work simulates the pressure buildup within the storage reservoir in response to CO 2 injection using a compositional simulator to better accommodate the temporospatial evolution of pressure buildup within the storage reservoir that is more accurately modeled using a heterogeneous geologic model and a compositional simulator that accounts for the multiphase interactions. The workflow is demonstrated using a case study for a 180,000-metric-ton-per-year storage project located in the PCOR (Plains CO 2 Reduction) Partnership region. For the storage project evaluated here, under the scenario where the leaky wellbore is open to a saline aquifer (thief zone) between the overlying seal (cap rock) and the underground sources of drinking water (USDW), the risk-based AOR essentially collapses to the areal extent of the CO 2 plume in the storage reservoir because the pressure buildup in the storage reservoir beyond the CO 2 plume is insufficient to drive formation fluids up a hypothetical leaky wellbore into the USDW. However, even under the conservative assumption that the leaky wellbore is not open to a thief zone, beyond the areal extent of the CO 2 plume, the incremental leakage is less than 400 m 3 over 20 years, which represents ~0.0001% or less of the total volume of water contained within the USDW rock volume. As discussed in the text, the threshold criterion for defining the risk-based AOR is site-specific and should be informed by the results of the sensitivity analysis and available site characterization data. The approach outlined in this paper is designed to be protective of USDWs and, therefore, comply with the Safe Drinking Water Act requirements and provisions for the U.S. EPA Class VI Underground Injection Control (UIC) Program (Class VI Rule) and North Dakota Administrative Code Chapter 43-05-01.

54 ENVIRONMENTAL SCIENCES↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pore-scale CFD simulations of clay mobilization in natural porous media due to fresh water injection

The present work investigates mechanisms of permeability impairment as a result of low-salinity fluid injection into brine-saturated porous media containing dispersible clays. Here, we present a computational fluid dynamics model at the pore-scale to simulate detachment, migration and straining of fine particles in porous media. The model uses an immersed boundary method to simulate the motion of clay fines in a fluid. In addition to the hydrodynamic forces, we model the Derjaguin-Landau-Verwey-Overbeek forces (DLVO) between clay fines and grains. Our simulations show the impact of the injected fluid's salinity and velocity on the concentration of clay fines retained on the grain surface. We see clay particles dislodging from the grain surface in clusters of up to 12 particles. Our simulation results also demonstrate clogging of narrow pore spaces by the detached particles from the grain surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatiotemporal flame propagations, combustion and solid particle emissions from lean and stoichiometric gasoline direct injection engine operation

Increased particle number and mass emissions in gasoline direct injection (GDI) engines should require to investigate in-cylinder flame and combustion characteristics associated with primary source of particle emissions. In this article, in-cylinder spatiotemporal flame luminosity is quantitatively characterized to features combustion process and solid particle emissions from a GDI engine operating in two lean and one stoichiometric modes. Low- and high-steady state operating points were used to compare combustion strategies on flame development and emission characteristics. A fiber-optic sensor composed of eight measurement channels detected the flame front and the direction of the flame propagation in the combustion chamber. Solid particle emissions in the exhaust were measured using an engine exhaust particle sizer and a micro soot sensor. Results of the experiments showed that two lean combustion modes by injection strategies resulted in distinct combustion and flame development. Lean combustion modes generated high diffusion flame by burning stratified rich-mixture. Although the lean cases resulted in strong diffusion flames, the lean-homogeneous produced similar particle size distributions with the stoichiometric mode with high ash particles. Piston pool fires on the piston surface in the lean-stratified mode induced a large accumulation mode with high particle mass concentrations.

42 ENGINEERING↗

A dynamic solvent chamber propagation estimation framework using RNN for warm solvent injection in heterogeneous reservoirs

Warm solvent injection (WSI), injecting low-temperature solvent into formations to reduce the viscosity of heavy oil, is a clean technology for heavy oil production through reducing greenhouse gas emissions and water usage. The success of WSI operation depends on the uniform development and propagation of solvent chambers in reservoirs. However, reservoir heterogeneity stemming from shale barriers plays a detrimental role in the conformance of solvent chamber development and oil production rate. In this work, we developed a novel recurrent neural network (RNN)-based framework with the capability of efficiently tracking and estimating the solvent chamber positions in heterogeneous reservoirs based on only production time-series data. The developed estimation model utilizes the “sequence-to-sequence" mapping methodology to correlate observed production time-series sequence and solvent chamber edge sequence via a long short-term memory (LSTM) algorithm. The trained RNN models exhibit high accuracy, evidenced by the predicted dynamic solvent chamber locations match the corresponding true locations from numerical simulation, with a high coefficient of determination (R 2 ) and a low mean squared error. Specifically, the achieved R 2 values exceed 0.98 on both the training and testing data. The developed RNN-based workflow was tested via several cases from both regularly- and irregularly-shaped shale barriers, and the results were promising. The predicted solvent chambers showed strong agreement with those obtained from numerical simulations. The major benefits of this workflow include reducing computational time and saving overall monitoring and tracking costs for conventional techniques. In conclusion, the present work would provide a good demonstration of the capability of practical integration of machine learning methods in solving engineering problems.

58 GEOSCIENCES↗

A comparative analysis of numerical approaches for the description of gas flow in clay-based repository systems: From a laboratory to a large-scale gas injection test

There is nowadays a consensus among many countries that geological disposal is a favourable solution for the long-term management. Although different host formations and different barrier systems are under consideration around the world, clay-based materials form an important component for waste isolation in most national programmes. Hence, a good comprehension of the effect of gas flow on the hydro-mechanical behaviour of clay-based soils is essential, both at laboratory and field scale. Task B under the international cooperative project DECOVALEX-2023 has recently shown that, after some enhancement, models can be employed to reproduce laboratory scale tests, even with different sample geometries 37 . However, further work is required to understand whether they can be applied to simulate a large-scale experiment. Up-scaling of models for the advective transport of gas through clay-based low permeable material presents a number of problems related to the difficulty in obtaining consistent hydrogeological parameters and constitutive relationships at both laboratory and field scale. Based on a unique dataset from a large-scale gas injection test (Lasgit) performed at the Äspö Hard Rock Laboratory (Sweden), Task B within DECOVALEX-2023 has explored the refinement of these numerical strategies applied to the simulation of gas flow. Work performed within the task reveals that codes do not need to be substantially modified from the laboratory models to reproduce full-scale tests: indeed, model parameters calibrated and validated at laboratory scale have been applied to predict field scale gas flow at Lasgit, including peak gas pressure and injected cumulative gas volume. By means of (1) the introduction of interfaces between blocks to reflect the experimental configuration and the (2) adjustment of some parameters (e.g., higher permeability), the updated models are able to represent most of the key features observed in the experimental data, even at a large scale.

Tamayo-Mas, E↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

The Corrected Distortion model for Lagrangian spray simulation of transcritical fuel injection

In this work, we present a detailed implementation and validation of the droplet modeling framework proposed by Dahms and Oefelein (2016) into the engine commercial CFD software CONVERGE using the User Defined Function (UDF) interface. The model accounts for the nonlinear deformation and oscillation experienced by liquid spray droplet injected into high pressure and temperature. Lagrangian spray simulations of Engine Combustion Network (ECN) Spray A are performed. Model validation against standard experimental measurements of liquid velocity, vapor mixture fraction is conducted. To perform more rigorous model validation, new experimental measurements based on Diffused Back Illumination (DBI) are introduced. The new measurements are processed for Projected Liquid Volume (PLV), which offers as close as possible one-to-one model validation for liquid penetration while offering new insights into the spray physics. Comparison with a One-D model based on adiabatic mixing theory by Siebers (1999) and Desantes et al. (2007) are also conducted. Through these model validation exercises, it is shown that the new framework improves liquid-phase penetration predictions, following a tendency for enhanced evaporation, compared to the standard approach for both Reynolds Average Navier Stokes (RANS) and Large Eddy Simulation (LES). Additionally, at the liquid length, maximum mixture fraction values predicted by the new approach are in good agreement those of an adiabatic mixing model. Qualitative analysis of the spray behaviors during the early stage of the injection process reveals that the proposed framework predicts significant increase in droplet evaporation rate with lower drop drag compared to the current standard approach.

42 ENGINEERING↗

3D Simulations of gas injection on callovo-oxfordian claystone assuming spatial heterogeneity and anisotropy

A series of gas injection tests on Callovo-Oxfordian (COx) claystone from the Bure underground research laboratory (URL) in France were carried out at the British Geological Survey (BGS). The tests were performed using a triaxial apparatus specifically designed to capture small volumetric strains induced by the injected gas flow and consequent material dilatancy. The long-duration experiments were monitored throughout. Measurements also included pressure, stresses (axial and radial stresses prescribed for each test stage), rate of gas inflow, gas outflow volume as well as pore-pressures observed at various points of the sample. A coupled hydro-gas-mechanical 3D numerical model has been developed to simulate the tests. Initial permeability is assumed heterogeneous throughout the specimen and embedded fractures are incorporated in the formulation. Gas pressure-induced deformations during the test lead to variations of permeability due to changes in matrix porosity and, especially, fracture aperture as well as fracture orientation due to material anisotropy. A programme of sensitivity analyses involving the variation of different aspects and parameters of the model contributes to a better understanding of the phenomena and highlights its complexity. The model is able to reproduce the observed behaviour of the tests.

58 GEOSCIENCES↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

A state of the art Lambertson septum magnet of the RHIC beam injection system

The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system. This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet.

43 PARTICLE ACCELERATORS↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗