Estimates of Internal Dose Resulting from I-131 Patients in Hotels - Paper 147
U.S. Nuclear Regulatory Commission Regulatory Guide 8.39 provides the following estimate to the maximum internal committed effective dose, CED{sub i}, to an individual from a released patient having received radionuclide therapy: CED{sub i} = 10{sup -5} Q{sub adm} DCF where Q{sub adm} = activity administered to the patient (Bq), DCF = ingestion dose coefficient (Sv/Bq). Since many released patients stay in a hotel for a day or two after administration of the I-131, an effort was made to provide reasonable estimates of internal committed effective dose to a housekeeper at a hotel. Reasonable exposure scenarios are presented herein with the resulting doses. The value 10{sup -6} from a health physics 'rule of thumb' for intake in workplace environments, and explored by Brodsky, was multiplied by a factor of 10 to account for the most highly exposed individual and to add a degree of conservatism to the evaluation. The ingestion dose coefficient was used since it was felt that the maximum internal intake would either be via the skin or mouth. The scenarios investigated to date and presented herein show rather low potential doses of hotel housekeepers due to internal contamination. The internal doses are conservative since they assume the immediate release and placement of the patient in the hotel or household. The existing Reg. Guide 8.39 internal dose estimate appears to be very conservative and are very low in comparison to external gamma ray dose due to released patients. (authors)