At least 397 records · Page 22

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Oxygen Solubility in Aqueous Amine Solvents with Common Additives Used for CO 2 Chemical Absorption

Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.

60 APPLIED LIFE SCIENCES↗

Fabrication of metal matrix composite by semi-solid powder processing

Various metal matrix composites (MMCs) are widely used in the automotive, aerospace and electrical industries due to their capability and flexibility in improving the mechanical, thermal and electrical properties of a component. However, current manufacturing technologies may suffer from insufficient process stability and reliability and inadequate economic efficiency and may not be able to satisfy the increasing demands placed on MMCs. Semi-solid powder processing (SPP), a technology that combines traditional powder metallurgy and semi-solid forming methods, has potential to produce MMCs with low cost and high efficiency. In this work, the analytical study and experimental investigation of SPP on the fabrication of MMCs were explored. An analytical model was developed to understand the deformation mechanism of the powder compact in the semi-solid state. The densification behavior of the Al6061 and SiC powder mixtures was investigated with different liquid fractions and SiC volume fractions. The limits of SPP were analyzed in terms of reinforcement phase loading and its impact on the composite microstructure. To explore adoption of new materials, carbon nanotube (CNT) was investigated as a reinforcing material in aluminum matrix using SPP. The process was successfully modeled for the mono-phase powder (Al6061) compaction and the density and density distribution were predicted. The deformation mechanism at low and high liquid fractions was discussed. In addition, the compaction behavior of the ceramic-metal powder mixture was understood, and the SiC loading limit was identified by parametric study. For the fabrication of CNT reinforced Al6061 composite, the mechanical alloying of Al6061-CNT powders was first investigated. A mathematical model was developed to predict the CNT length change during the mechanical alloying process. The effects of mechanical alloying time and processing temperature during SPP were studied on the mechanical, microstructural and compositional properties of the Al6061-CNT composites. A shear lag model was applied to predict the mechanical property (hardness) of the composite. This work demonstrated the promising potential of SPP in the fabrication of particle/fiber (nanotube) reinforced MMCs.

36 MATERIALS SCIENCE↗

Transverse impact by RCCs on S-glass and Kevlar® FRC strips

This study aims to isolate interactions between plies and tows and reveal fundamental physics involved in transverse impact on fiber-reinforced composite (FRC) structures. Composite strips were sectioned from large panels and characterized by optical photography, three-dimensional synchrotron X-ray computed tomography, and scanning electron microscopy (SEM). Each strip was impacted perpendicularly by a right circular cylinder (RCC) projectile at a velocity ranging from ~ 150 to 600 m/s. The global strip behavior, as well as localized deformation and failure of the strip near the projectile corner, were both captured by high-speed optical imaging. S-Glass FRC strips were observed to fail in tension ahead of the RCC projectiles’ flat surfaces while Kevlar® FRC strips fractured at the projectile corners. The concept of critical velocity region previously used for impact on yarns was introduced to define different failure modes of each composite strip type. The strip damage extent was found to increase with the impact velocity and reach the maximum at the upper limit of the critical velocity region. Above the critical velocity region, the damage extent decreased with impact velocity. Wave propagations and load histories in the composite strips during impact were quantified and compared with Smith’s theory. Finally, critical velocities of single fibers, yarns, and composite strips and ballistic limits of single-ply and multi-ply composite panels were compared to provide insight into the design of impact-resistant fabrics and composites.

42 ENGINEERING↗

Enhancing power grid resilience to winter storms via generator winterization with equity considerations

Here we develop two-stage stochastic programming models for generator winterization that enhance power grid resilience while incorporating social equity. The first stage in our models captures the investment decisions for generator winterization, and the second stage captures the operation of a degraded power grid, with the objective of minimizing load shed and social inequity. To incorporate equity into our models, we propose a concept called adverse effect probability that captures the disproportionate effects of power outages on communities with varying vulnerability levels. Grid operations are modeled using DC power flow, and equity is captured through mean or maximum adverse effects experienced by communities. We apply our models to a synthetic Texas power grid, using winter storm scenarios created from the generator outage data from the 2021 Texas winter storm. Our extensive numerical experiments show that more equitable outcomes, in the sense of reducing adverse effects experienced by vulnerable communities during power outages, are achievable with no impact on total load shed through investing in winterization of generators in different locations and capacities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Platinum Ionomer Interface Properties of Polymer Electrolyte Fuel Cells

A well-designed cathode catalyst layer with optimal ionomer distribution is critical to minimizing amount of Platinum (Pt) content in polymer electrolyte fuel cells (PEFCs). The impact of Pt loading, ionomer content and carbon support types on the catalyst/ionomer interface were also investigated at dry and wet conditions. Higher Pt loadings resulted in higher double layer capacity (C dl ) and similar electrochemical surface area (ECSA) due to well dispersed ionic phase material. Higher ionomer content resulted in higher ionic conductivity but also showed similar SO 3 − group coverage. High surface area (HSA) carbon support had larger ECSA and C dl at both dry and wet conditions, as less agglomerated Pt was well dispersed in the meso-pores of the support. Lower SO 3 − group coverages were observed for HSA carbon than for Vulcan carbon due to Pt particles being buried within the porous HSA carbon support. The effect of cell conditioning and voltage recovery on the PEFC cathode catalyst layer was shown to have minimal impact on SO 3 − group coverage despite a decrease in C dl and ECSA due to the size increase of Pt particles. At dry condition, a significant increases in SO 3 − group coverage were observed for all MEAs due to higher adsorptivity of ionomer in dry conditions.

25 ENERGY STORAGE↗

Large-scale parametric modeling of spent nuclear fuel dynamics in the 30 cm package drop scenario

Packages used to transport spent nuclear fuel (SNF) are required by the U.S. Code of Federal Regulations 10 CFR 71.71 to demonstrate satisfactory performance during a drop scenario. While the CFR is meant to ensure safe package function, it does not evaluate survival of the SNF within. The U.S. Department of Energy Spent Fuel and Waste Science and Technology program is working on closing the knowledge gap related to the response of SNF to external mechanical loads, including the hypothetical 30 cm package drop scenario in the CFR. In support of this effort, LS-DYNA finite element simulations were developed by Pacific Northwest National Laboratory (PNNL) to model generic drop scenarios at both the package and fuel assembly level. The models were validated against one-third scale package and full scale fuel assembly drop test data and were exercised to predict fuel cladding strains in a narrow range of model configurations. This work describes a large-scale parametric study conducted by PNNL using the previously developed and validated PWR finite element model, with the addition of a new generic BWR assembly model. The motivation for the parametric study was to characterize the broad range of SNF responses in the 30 cm package drop scenario. This was accomplished by varying the drop orientation, fuel assembly type (17x17 PWR and 10x10 BWR), burnup, cladding temperature, spacer grid buckling load, package mass, impact limiter stiffness, and mechanical gap conditions within the basket. A MATLAB framework was developed to automate LS-DYNA model generation and execution on PNNL institutional computing resources. In total, over 2000 simulations were performed. For each simulation, the SNF response was quantified in terms of permanent grid deformation, fuel rod contact pressure, and strains within the fuel rods, guide tubes, and water rods. The results provide valuable insight into the range of responses that could be reasonably expected from SNF in the hypothetical drop scenario, as well as the sensitivity to each input parameter. The results of this parametric study are a key component of the testing and modeling strategy the Spent Fuel and Waste Science and Technology program is using to close the external loads knowledge gap.

Kadooka, Kevin↗

Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the Response of Electricity Load to Climate Change

Our purpose is to develop a methodology to quantify the impact of climate change on electric loads in the United States. We perform simple linear regression, assisted by geospatial smoothing, on paired temperature and load time-series to estimate the heating- and coolinginduced sensitivity to temperature across 300 transmission zones and 16 seasonal and diurnal time periods. The estimated load sensitivities can be coupled with climate scenarios to quantify the potential impact of climate change on load, with a primary application being long-term electricity scenarios. The method allows regional and seasonal differences in climate and load response to be reflected in the electricity scenarios. While the immediate product of this analysis was designed to mesh with the spatial and temporal resolution of a specific electricity model to enable climate change scenarios and analysis with that model, we also propose that the process could be applied for other models and purposes.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of TRU Fueled SFR Core during the Transition with Partially Loaded LEU Assemblies

The fast reactor (FR) fuels typically require higher fissile content than the thermal reactor fuels because the cross sections of the fissile isotopes are smaller relative to the fertile isotopes and higher neutron leakage from the reactor core. The medium-sized high-burnup sodium-cooled fast reactors (SFRs) in the framework of uranium-plutonium/transuranic (U/Pu or U/TRU) fuel-cycle can be optimized to operate with less than 17 % of Pu/TRU content in the driver fuel while having higher TRU conversion ratios (CR~1.0) [1]. However, possible shortage or inaccessibility to TRU based fuel could be accommodated by the use of uranium-based fuels on demand such as low enriched uranium (LEU) having significantly higher 235U content than used in the commercial light water reactors (LWRs), which is defined as high-assay LEU. The reactor systems having low TRU conversion ratio are commonly categorized as burner reactors, which include LWRs and even can be achieved by FRs with designed to utilize higher TRU fractions (e.g., increased neutron leakage and lower fuel volume fractions). Such reactor systems need to be initially loaded with high excess reactivity, which decreases toward the end of cycle, in order to achieve target burnup conditions. Therefore, in order to offset the excess reactivity, neutron absorbing materials need to be inserted into the core to compensate (e.g., control rods). By reducing the neutron leakage (e.g., increasing the fuel volume fraction or thicker blankets), the TRU conversion ratio in the FR can be increased. If the TRU conversion ratio becomes 1.0 (technically slightly greater than 1.0 to account for process losses during recycle), the reactor is in the condition known as “breakeven”, in which fuel contains the same amount of fissile material after recycling that was used to fuel the reactor. In such a condition, combined with the fact that fission products do not have strong poisoning effects in FRs, the reactivity swing becomes smaller than that of burner type reactors. For breeders, the reactivity can increase toward the end of the cycle because more fissile material is produced than consumed. In this regard, the breakeven FR core is implicitly optimized in a sense by eliminating the large insertion of control elements to offset the reactivity during the normal operation. However, the breakeven condition here is assumed to be achieved only by the TRU based fuel. Possible lack of TRU based fuel needs to be compensated by available LEU resources containing equivalent amount of fissile (i.e., 235U). The use of LEU will have some impact on important safety parameters that need to be evaluated. U-235 has a higher effective delayed neutron fraction than Pu-239. Also, the number of neutrons produced by fissions per neutron absorption (i.e. ?) of 235U in the fast energy range (>1e4 eV) is lower than that of 239Pu, which may lead to the poor fissile conversion when LEU is used as a high-conversion FR fuel. The full-paper presents the study of the impact of partially loaded LEU fuels within TRU fueled breakeven SFR on the transition of nuclide evolutions and core characteristics particularly focusing on the burnup reactivity swing. The full paper analyzes how the large reactivity swing occurs during the LEU loading and addresses possible options to reduce it to the level equivalent to that of the TRU fueled SFR core.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Societal decisions about climate mitigation will have dramatic impacts on eutrophication in the 21st century

Excessive nitrogen loading leads to degraded water quality that harms human and ecosystem health. Here, we examine the impact of changes in land use and land management for six combinations of socioeconomic pathways (SSPs) and climate outcomes and find that future societal choices will substantially impact riverine nitrogen loading (+54% to -7%) for the continental United States by the end-of-the-century. Regional impacts will be even larger. The increase in nitrogen loading is projected both for high emission pathways with increased food demand and for societal pathways that achieve high climate mitigation through increased biofuel production. Conversely, projected decreases in nitrogen loading are associated with future pathways with low food demand and no climate mitigation efforts. Thus, climate mitigation may have unintended consequences in the form of increased eutrophication, although some pathways suggests that limiting climate change and eutrophication need not be mutually exclusive. We find that changes in cropland, developed land, and fertilizer application rates are all important drivers in explaining the projected changes in nitrogen loading. Climate change–induced precipitation changes will further amplify the projected increase in nitrogen loading or offset the improvement in loading resulting in a net change of +1% to +68% by the end-of-the-century. Globally, vast portions of South, East, and Southeast Asia will also likely experience increased eutrophication by the end-of-the-century due to increased cropland area and agricultural intensification. These findings highlight the need to account for the impact of both societal and climate trends in designing strategies for managing inland and coastal water quality.

54 ENVIRONMENTAL SCIENCES↗

HOSS: an implementation of the combined finite-discrete element method

Nearly thirty years since its inception, the combined finite-discrete element method (FDEM) has made remarkable strides in becoming a mainstream analysis tool within the field of Computational Mechanics. FDEM was developed to effectively “bridge the gap” between two disparate Computational Mechanics approaches known as the finite and discrete element meth-ods. At Los Alamos National Laboratory (LANL) researchers developed the Hybrid Optimization Software Suite (HOSS) as a hybrid multi-physics platform, based on FDEM, for the simulation of solid material behavior complemented with the latest technological enhancements for full fluid–solid interaction. Furthermore, in HOSS, several newly developed FDEM algorithms have been implemented that yield more accurate material deformation formulations, inter-particle interaction solvers, and fracture and fragmentation solutions. Additionally, an explicit computational fluid dynamics solver and a novel fluid–solid interaction algorithms have been fully integrated (as opposed to coupled) into the HOSS’ solid mechanical solver, allowing for the study of an even wider range of problems. Advancements such as this are leading HOSS to become a tool of choice for multi-physics problems. Finally, HOSS has been successfully applied by a myriad of researchers for analysis in rock mechanics, oil and gas industries, engineering application (structural, mechanical and biomedical engineering), mining, blast loading, high velocity impact, as well as seismic and acoustic analysis. This paper intends to summarize the latest development and application efforts for HOSS.

58 GEOSCIENCES↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

The high explosives & affected targets (HEAT) dataset

Artificial Intelligence (AI) surrogate models offer a computationally efficient alternative to full-physics simulations, yet no existing datasets are publicly available for training, testing, and validation of machine learning models of the dynamics of high-explosive driven shocks through multiple materials. Shock propagation through materials is a computationally challenging problem because simulations must include material-specific equations of state (EOS) along with descriptions of other physical processes such as plastic deformation, phase change, damage processes, fluid instabilities, and multi-material interactions. Shocks are typically initiated by high-velocity impacts or explosive loading. The latter case necessitates the addition of models of reactive materials to represent high-explosive (HE) detonation. Here, to address the lack of an expansive dataset for multi-material shock propagation in the AI/ML community, we present the High-Explosives and Affected Targets (HEAT) Dataset. HEAT is a physics-rich collection of two-dimensional, cylindrically symmetric, simulations generated using an Eulerian, multi-material, shock-propagation code developed at Los Alamos National Laboratory. The dataset includes two partitions: (1) the expanding shock-cylinder (CYL) simulations, Figs. 1, and (2) the Perturbed Layered Interface (PLI) simulations, Fig. 2. Entries in both partitions consist of time series of arrays of thermodynamic fields (pressure, density, and temperature), kinematic fields (position and velocity), and additional fields that depend on thermodynamic and/or kinematic fields (e.g., material stress). Materials in the CYL partition include solids (aluminium, copper, depleted uranium, stainless steel, tantalum, and a generic polymer), a liquid (water), gases (air, nitrogen), and a generic detonating material (high explosive, HE). The PLI partition spans a highly varying geometry but consists of fixed materials across entries: Copper, aluminium, stainless steel, generic polymer, and generic HE. HEAT captures critical phenomena such as momentum transfer, shock propagation, plastic deformation, and thermal effects, making HEAT a valuable benchmark for development of AI/ML emulation of multi-material shock propagation.

36 MATERIALS SCIENCE↗

Survey and Analysis of Weather Data for Building Energy Simulations

In recent years, calibrated energy modeling of residential and commercial buildings has gained importance in a retrofit-dominated market. Accurate weather data plays an important role in this calibration process and projected energy savings. It would be ideal to measure weather data at the building location to capture relevant microclimate variation but this is generally considered cost-prohibitive. There are data sources publicly available with high temporal sampling rates but at relatively poor geospatial sampling locations. To overcome this limitation, there are a growing number of service providers that claim to provide real time and historical weather data for 20-35 km2 grid across the globe. Unfortunately, there is limited documentation from 3rd-party sources attesting to the accuracy of this data. This paper compares provided weather characteristics with data collected from a weather station inaccessible to the service providers. Monthly average dry bulb temperature; relative humidity; direct, diffuse and horizontal solar radiation; and wind speed are statistically compared. Moreover, we ascertain the relative contributions of each weather variable and its impact on building loads. Annual simulations are calculated for three different building types, including a closely monitored and automated energy efficient research building. The comparison shows that the difference for an individual variable can be as high as 90%. In addition, annual building energy consumption can vary by 7% while monthly building loads can vary by 40% as a function of the provided location s weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗