Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

SMALL-SCALE HEATING EVENTS IN THE SOLAR ATMOSPHERE. I. IDENTIFICATION, SELECTION, AND IMPLICATIONS FOR CORONAL HEATING

We present a comprehensive method to analyze small-scale heating events in detail in a 3D magnetohydrodynamics simulation for quiet-Sun conditions. The method determines the number, volume, and some general geometric properties of the small-scale heating events at different instants in a simulation with a volume of 16 × 8 × 16 Mm{sup 3}, spanning from the top of the convection zone to the corona. We found that there are about 10{sup 4} small-scale heating events at any instant above the simulated area of 128 Mm{sup 2}. They occur mainly at heights between 1.5 and 3.0 Mm. We determine the average value of their projected vertical extent, which ranges from 375 to 519 km over time, and we show that height, volume, and energy distribution of the events at any instant resemble power laws. Finally, we demonstrate that larger heating structures are a combination of much smaller heating events and that small-scale heating events dissipate enough energy to maintain the coronal energetic balance at any instant.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for Suitable Binary Fluid for an Ejector Heat Pump for Domestic Water Heating

Water heating is a major source of energy consumption in the U.S. residential sector. Heat pumps can significantly increase the energy efficiency of water heating. An ejector heat pump (EHP) is a novel, thermally driven heat pump that uses an ejector as a thermocompressor. Choosing suitable working fluids is critical in developing high-performance EHPs. Therefore, this research screens binary fluid pairs (BFPs) for EHPs to produce domestic hot water at a high coefficient of performance (COP). The criteria for screening BFP candidates for EHP water heaters (EHPWHs) are established, and BFP candidates are shortlisted. This study identifies HFE7000, Novec649, HFE7100, HFE7200, and HFE7500 for the primary fluids and RE170, R600a, R600, and R1234ze(Z) for the secondary fluids. The thermodynamic model is employed to investigate the performance of EHPWHs using the shortlisted BFPs under various operating parameters, including the evaporation pressure of the primary working fluid in the high-temperature evaporator and the condensation temperature. In conclusion, the highest heating-cycle COP of 1.328 is achieved by an EHPWH operating with HFE7000/R600 at a condenser temperature of 50 °C and a pressure of 1.69 MPa in the high-temperature evaporator.

42 ENGINEERING↗

The role of parallel heat transport in the relation between upstream scrape-off layer widths and target heat flux width in H-mode plasmas of NSTX.

The physics of parallel heat transport was tested in the Scrape-off Layer (SOL) plasma of the National Spherical Torus Experiment (NSTX) [M. Ono, et al., Nucl. Fusion 40, 557 (2000) and S. M. Kaye, et al., Nucl. Fusion 45, S168 (2005)] tokamak by comparing the upstream electron temperature (T{sub e}) and density (n{sub e}) profiles measured by the mid-plane reciprocating probe to the heat flux (q{sub {perpendicular}}) profile at the divertor plate measured by an infrared (IR) camera. It is found that electron conduction explains the near SOL width data reasonably well while the far SOL, which is in the sheath limited regime, requires an ion heat flux profile broader than the electron one to be consistent with the experimental data. The measured plasma parameters indicate that the SOL energy transport should be in the conduction-limited regime for R-R{sub sep} (radial distance from the separatrix location) < 2-3 cm. The SOL energy transport should transition to the sheath-limited regime for R-R{sub sep} > 2-3cm. The T{sub e}, n{sub e}, and q{sub {perpendicular}} profiles are better described by an offset exponential function instead of a simple exponential. The conventional relation between mid plane electron temperature decay length ({lambda}{sub Te}) and target heat flux decay length ({lambda}{sub q}) is {lambda}{sub Te} = 7/2{lambda}{sub q}, whereas the newly-derived relation, assuming offset exponential functional forms, implies {lambda}{sub Te} = (2-2.5){lambda}{sub q}. The measured values of {lambda}{sub Te}/{lambda}{sub q} differ from the new prediction by 25-30%. The measured {lambda}{sub q} values in the far SOL (R-R{sub sep} > 2-3cm) are 9-10cm, while the expected values are 2.7 < {lambda}{sub q} < 4.9 cm (for sheath-limited regime). We propose that the ion heat flux profile is substantially broader than the electron heat flux profile as an explanation for this discrepancy in the far SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric Adsorption Heat Pump for Electric Vehicles: Electric-Powered Adsorption Heat Pump for Electric Vehicles

HEATS Project: PNNL is developing a new class of advanced nanomaterial called an electrical metal organic framework (EMOF) for EV heating and cooling systems. The EMOF would function similar to a conventional heat pump, which circulates heat or cold to the cabin as needed. However, by directly controlling the EMOF's properties with electricity, the PNNL design is expected to use much less energy than traditional heating and cooling systems. The EMOF-based heat pumps would be light, compact, efficient, and run using virtually no moving parts.

ARPA-E↗

Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

exergy↗

Analysis of heating load diversity in German residential districts and implications for the application in district heating systems

In recent years, the application of district heating systems for the heat supply of residential districts has been increasing in Germany. Central supply systems can be very efficient due to diverse energy demand profiles which may lead to reduced installed equipment capacity. Load diversity in buildings has been investigated in former studies, especially for the electricity demand. However, little is known about the influence of single building characteristics (such as building envelope or hot water demand) on the overall heating peak load of a residential district. For measuring the diversity, the peak load ratio (PLR) index is used to represent the percentage reduction of peak load of a district system from a simple sum of individual peak loads of buildings. A total of 144 residential building load profiles have been created with the dynamic building simulation software IDA ICE for a theoretical analysis in which the PLR reaches 15%. Within this study, certain district features are identified which lead to higher diversity. Furthermore, these results are used in a district heating simulation model which confronts the possible advantage of reduced installed capacity with the practical disadvantage of heat distribution losses. Likewise, the influence of load density and the districts building structure can be analyzed. This study shows that especially in districts with high load density, which consist of newly constructed buildings with low supply temperature and high influence of the hot water demand, the advantages of load diversity can be exploited.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

Saturated critical heat flux in a multi-microchannel heat sink fed by a split flow system

An extensive experimental campaign has been carried out for the measurement of saturated critical heat flux in a multi-microchannel copper heat sink. The heat sink was formed by 29 parallel channels that were 199 {mu}m wide and 756 {mu}m deep. In order to increase the critical heat flux and reduce the two-phase pressure drop, a split flow system was implemented with one central inlet at the middle of the channels and two outlets at either end. The base critical heat flux was measured using three HFC Refrigerants (R134a, R236fa and R245fa) for mass fluxes ranging from 250 to 1500 kg/m{sup 2} s, inlet subcoolings from -25 to -5 K and saturation temperatures from 20 to 50 C. The parametric effects of mass velocity, saturation temperature and inlet subcooling were investigated. The analysis showed that significantly higher CHF was obtainable with the split flow system (one inlet-two outlets) compared to the single inlet-single outlet system, providing also a much lower pressure drop. Notably several existing predictive methods matched the experimental data quite well and quantitatively predicted the benefit of higher CHF of the split flow. (author)

42 ENGINEERING↗

Microstructural response to heat affected zone cracking of prewelding heat-treated Inconel 939 superalloy

The microstructural response to cracking in the heat-affected zone (HAZ) of a nickel-based IN 939 superalloy after prewelding heat treatments (PWHT) was investigated. The PWHT specimens showed two different microstructures: 1) spherical ordered {gamma} Prime precipitates (357-442 nm), with blocky MC and discreet M{sub 23}C{sub 6} carbides dispersed within the coarse dendrites and in the interdendritic regions; and 2) ordered {gamma} Prime precipitates in 'ogdoadically' diced cube shapes and coarse MC carbides within the dendrites and in the interdendritic regions. After being tungsten inert gas welded (TIG) applying low heat input, welding speed and using a more ductile filler alloy, specimens with microstructures consisting of spherical {gamma} Prime precipitate particles and dispersed discreet MC carbides along the grain boundaries, displayed a considerably improved weldability due to a strong reduction of the intergranular HAZ cracking associated with the liquation microfissuring phenomena. - Highlights: Black-Right-Pointing-Pointer Homogeneous microstructures of {gamma} Prime spheroids and discreet MC carbides of Ni base superalloys through preweld heat treatments. Black-Right-Pointing-Pointer {gamma} Prime spheroids and discreet MC carbides reduce the intergranular HAZ liquation and microfissuring of Nickel base superalloys. Black-Right-Pointing-Pointer Microstructure {gamma} Prime spheroids and discreet blocky type MC carbides, capable to relax the stress generated during weld cooling. Black-Right-Pointing-Pointer Low welding heat input welding speeds and ductile filler alloys reduce the HAZ cracking susceptibility.

36 MATERIALS SCIENCE↗

Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating

The continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl{sub 2}6H{sub 2}O was used as PCM in thermal energy storage with a melting temperature of 29 C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18-23% of total daily thermal energy requirements of the greenhouse for 3-4 h, in comparison with the conventional heating device. (author)

14 SOLAR ENERGY↗

Heat transfer and pressure drop of supercritical carbon dioxide flowing in several printed circuit heat exchanger channel patterns

Closed-loop Brayton cycles using supercritical carbon dioxide (SCO{sub 2}) show potential for use in high-temperature power generation applications including High Temperature Gas Reactors (HTGR) and Sodium-Cooled Fast Reactors (SFR). Compared to Rankine cycles SCO{sub 2} Brayton cycles offer similar or improved efficiency and the potential for decreased capital costs due to a reduction in equipment size and complexity. Compact printed-circuit heat exchangers (PCHE) are being considered as part of several SCO{sub 2} Brayton designs to further reduce equipment size with increased energy density. Several designs plan to use a gas cooler operating near the pseudo-critical point of carbon dioxide to benefit from large variations in thermophysical properties, but further work is needed to validate correlations for heat transfer and pressure-drop characteristics of SCO{sub 2} flows in candidate PCHE channel designs for a variety of operating conditions. This paper presents work on experimental measurements of the heat transfer and pressure drop behavior of miniature channels using carbon dioxide at supercritical pressure. Results from several plate geometries tested in horizontal cooling-mode flow are presented, including a straight semi-circular channel, zigzag channel with a bend angle of 80 degrees, and a channel with a staggered array of extruded airfoil pillars modeled after a NACA 0020 airfoil with an 8.1 mm chord length facing into the flow. Heat transfer coefficients and bulk temperatures are calculated from measured local wall temperatures and local heat fluxes. The experimental results are compared to several methods for estimating the friction factor and Nusselt number of cooling-mode flows at supercritical pressures in millimeter-scale channels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase transitions in heated Sr{sub 2}MgTeO{sub 6} double perovskite oxide probed by X-ray diffraction and Raman spectroscopy

Double-perovskite oxide Sr{sub 2}MgTeO{sub 6} has been synthetized, and its crystal structure was probed by the technique of X-ray diffraction at room temperature. The structure is monoclinic, space group I2/m. Temperature-induced phase transitions in this compound were investigated by Raman spectroscopy up to 550 °C. Two low-wavenumber modes corresponding to external lattice vibrations merge at temperature of around 100 °C, indicating a phase transition from the monoclinic (I2/m) to the tetragonal (I4/m) structure. At 300 °C, changes in the slopes of temperature dependencies of external and O–Te–O bending modes are detected and interpreted as a second phase transition from the tetragonal (I4/m) to the cubic (Fm-3m) structure.

36 MATERIALS SCIENCE↗