Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

391 records · Page 22

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Platform for Remote Deployment and Training for Enhanced Building Operation Practices (Building Re-Tuning and On-going Commissioning)

While a building’s energy usage is driven largely by its design and use, building operator behavior has a strong influence on its energy consumption. This project developed and piloted a specific, data-driven coaching methodology to help operators understand how they can adjust operations and/or affect no/low-cost repairs or upgrades to their specific building HVAC systems to reduce energy consumption. Named BuildingCoach, the operational optimization method used is based on the Building Re-tuning approach developed by the Pacific Northwest National Laboratory. A building operations analytics market has matured over the past decade, though its potential to affect energy-saving changes has not been fully realized. Training operators to understand the methods for operational optimization with the explicit approach of using building-system performance data is hypothesized to create a more effective, longer lasting result in building energy efficiency, and this strategy is the fundamental premise of this project. With the support of an Industry Advisory Board, the project succeeded in developing materials and recruiting for and delivering three pilot cohorts. Deliverables included twenty-two self-paced training modules (accessed via a Learning Management System) and a web-based platform that includes access to real-time building system data and a repository for building system documentation. The project set out to have 100 participants from 50 buildings in three pilot cohorts. In the end, there were 28 participants from 17 buildings, i.e., a significant shortfall. The first two pilot cohorts had only two buildings in each, and this was partially due to difficulties in deploying the Building Operator Coaching Solution (“the BOCS”), which is technology that extracts the data from the controls network and presents it as prescribed for coaching. In the third cohort, the project team deployed the BOCS successfully to 13 buildings, the methodology was piloted as intended, and numerous opportunities for optimization were identified. The BuildingCoach business plan charts a path to an economically sustainable effort. However, even with a licensing model captured in the final version of the business plan, the scalability is still limited to keeping less than 1,000 buildings affected by 2033. Even so, there are unexplored paths to greater scalability that are being considered. CUNY BPL is working to perpetuate and grow the use of BuildingCoach. As of this writing, about twenty buildings have either been connected or will be connected with operators coached / to be coached in the NYC municipal portfolio, twelve buildings across four campuses in NY State will use BuildingCoach, a NY upstate county wishes for six or seven buildings to participate with the support of funding from NYSERDA, and others have also expressed interest. In the decades to come, there will be an increasing percentage of large and mid-sized buildings that incorporate automated system optimization (ASO), and the building operators’ role will shift to spend more time on maintenance and monitoring. Meanwhile, programs such as BuildingCoach will play a critical role in optimizing operations. And, regardless of the emergence of ASO, operators will still need to understand how their systems operate so that they can monitor them properly. Within that context, BuildingCoach is an important step towards operators’ understanding of efficient building system operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Dual Phase Soft Magnetic Laminates for Low-cost, Non/Reduced-Rare-Earth Containing Electrical Machines

To accelerate the mass market adoption of electric drive vehicles, the key technology barriers in electric motors are (1) magnet cost and rare-earth element price volatility; (2) non-rare-earth electric motor performance; and (3) materials property optimization. The goal of this project was to address these barriers by advancing a unique and innovative dual phase soft magnetic material technology and demonstrating the material in a 30-kW synchronous reluctance motor without using any permanent magnet for electric vehicles. Dual phase magnetic materials offer the electric motor designer the ability to locally control the magnetic saturation level in a motor laminate, while at the same time enhancing the mechanical strength of the laminate material, resulting in an enhancement in motor performance and efficiency. Scalable dual phase soft magnetic laminates manufacturing technologies were developed in collaboration with multiple US manufacturers. 1000 lbs of alloy sheet with a thickness of 0.25mm and width of 280 mm was manufactured within the specifications. Batch sizes of up to 240 laminates per run were produced from the alloy sheet. Two prototype motors with dual phase soft magnetic laminates were designed, built, and tested. The major goal of building the subscale prototype as a pathway to develop scalable manufacturing technologies for the dual phase soft magnetic laminates was met. The additional goal of building and testing the subscale prototype in order to validate the calculated performance with the tested motor performance was also met. For the full-scale 30kW continuous power synchronous reluctance motor prototype, the tested performance met the targets in terms of continuous power at the operating speeds up to 8000 rpm. Post-test studies were conducted and the root causes for the discrepancy between the predicted and tested peak power, continuous power at high speed range, and efficiency were identified. Further modeling study showed that the dual phase rotor machine has a 27% higher torque to active weight ratio than an equivalent performance silicon steel rotor machine. Application space and multiple discussions with traction motor and electric vehicle manufacturers for commercialization of the dual phase soft magnetic material technology were identified and conducted. An initial cost model was established based on the developed manufacturing technologies with the US manufacturers. Future paths for further cost reduction were identified, including increasing the market volume by broadening the applications of the dual phase soft magnetic laminate technology for electric machines in other energy sections such as oil & gas, heating, ventilation, and air conditioning (HVAC), and power generation.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Integrated Mechanical Pods

This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.

30 DIRECT ENERGY CONVERSION↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗