Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Platform for Remote Deployment and Training for Enhanced Building Operation Practices (Building Re-Tuning and On-going Commissioning)

While a building’s energy usage is driven largely by its design and use, building operator behavior has a strong influence on its energy consumption. This project developed and piloted a specific, data-driven coaching methodology to help operators understand how they can adjust operations and/or affect no/low-cost repairs or upgrades to their specific building HVAC systems to reduce energy consumption. Named BuildingCoach, the operational optimization method used is based on the Building Re-tuning approach developed by the Pacific Northwest National Laboratory. A building operations analytics market has matured over the past decade, though its potential to affect energy-saving changes has not been fully realized. Training operators to understand the methods for operational optimization with the explicit approach of using building-system performance data is hypothesized to create a more effective, longer lasting result in building energy efficiency, and this strategy is the fundamental premise of this project. With the support of an Industry Advisory Board, the project succeeded in developing materials and recruiting for and delivering three pilot cohorts. Deliverables included twenty-two self-paced training modules (accessed via a Learning Management System) and a web-based platform that includes access to real-time building system data and a repository for building system documentation. The project set out to have 100 participants from 50 buildings in three pilot cohorts. In the end, there were 28 participants from 17 buildings, i.e., a significant shortfall. The first two pilot cohorts had only two buildings in each, and this was partially due to difficulties in deploying the Building Operator Coaching Solution (“the BOCS”), which is technology that extracts the data from the controls network and presents it as prescribed for coaching. In the third cohort, the project team deployed the BOCS successfully to 13 buildings, the methodology was piloted as intended, and numerous opportunities for optimization were identified. The BuildingCoach business plan charts a path to an economically sustainable effort. However, even with a licensing model captured in the final version of the business plan, the scalability is still limited to keeping less than 1,000 buildings affected by 2033. Even so, there are unexplored paths to greater scalability that are being considered. CUNY BPL is working to perpetuate and grow the use of BuildingCoach. As of this writing, about twenty buildings have either been connected or will be connected with operators coached / to be coached in the NYC municipal portfolio, twelve buildings across four campuses in NY State will use BuildingCoach, a NY upstate county wishes for six or seven buildings to participate with the support of funding from NYSERDA, and others have also expressed interest. In the decades to come, there will be an increasing percentage of large and mid-sized buildings that incorporate automated system optimization (ASO), and the building operators’ role will shift to spend more time on maintenance and monitoring. Meanwhile, programs such as BuildingCoach will play a critical role in optimizing operations. And, regardless of the emergence of ASO, operators will still need to understand how their systems operate so that they can monitor them properly. Within that context, BuildingCoach is an important step towards operators’ understanding of efficient building system operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Dual Phase Soft Magnetic Laminates for Low-cost, Non/Reduced-Rare-Earth Containing Electrical Machines

To accelerate the mass market adoption of electric drive vehicles, the key technology barriers in electric motors are (1) magnet cost and rare-earth element price volatility; (2) non-rare-earth electric motor performance; and (3) materials property optimization. The goal of this project was to address these barriers by advancing a unique and innovative dual phase soft magnetic material technology and demonstrating the material in a 30-kW synchronous reluctance motor without using any permanent magnet for electric vehicles. Dual phase magnetic materials offer the electric motor designer the ability to locally control the magnetic saturation level in a motor laminate, while at the same time enhancing the mechanical strength of the laminate material, resulting in an enhancement in motor performance and efficiency. Scalable dual phase soft magnetic laminates manufacturing technologies were developed in collaboration with multiple US manufacturers. 1000 lbs of alloy sheet with a thickness of 0.25mm and width of 280 mm was manufactured within the specifications. Batch sizes of up to 240 laminates per run were produced from the alloy sheet. Two prototype motors with dual phase soft magnetic laminates were designed, built, and tested. The major goal of building the subscale prototype as a pathway to develop scalable manufacturing technologies for the dual phase soft magnetic laminates was met. The additional goal of building and testing the subscale prototype in order to validate the calculated performance with the tested motor performance was also met. For the full-scale 30kW continuous power synchronous reluctance motor prototype, the tested performance met the targets in terms of continuous power at the operating speeds up to 8000 rpm. Post-test studies were conducted and the root causes for the discrepancy between the predicted and tested peak power, continuous power at high speed range, and efficiency were identified. Further modeling study showed that the dual phase rotor machine has a 27% higher torque to active weight ratio than an equivalent performance silicon steel rotor machine. Application space and multiple discussions with traction motor and electric vehicle manufacturers for commercialization of the dual phase soft magnetic material technology were identified and conducted. An initial cost model was established based on the developed manufacturing technologies with the US manufacturers. Future paths for further cost reduction were identified, including increasing the market volume by broadening the applications of the dual phase soft magnetic laminate technology for electric machines in other energy sections such as oil & gas, heating, ventilation, and air conditioning (HVAC), and power generation.

33 ADVANCED PROPULSION SYSTEMS↗