Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOUSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-J-196: Implementation of An In-House Visual Feedback System for Motion Management During Radiation Therapy

Purpose: To describe an in-house video goggle feedback system for motion management during simulation and treatment of radiation therapy patients. Methods: This video goggle system works by splitting and amplifying the video output signal directly from the Varian Real-Time Position Management (RPM) workstation or TrueBeam imaging workstation into two signals using a Distribution Amplifier. The first signal S[1] gets reconnected back to the monitor. The second signal S[2] gets connected to the input of a Video Scaler. The S[2] signal can be scaled, cropped and panned in real time to display only the relevant information to the patient. The output signal from the Video Scaler gets connected to an HDMI Extender Transmitter via a DVI-D to HDMI converter cable. The S[2] signal can be transported from the HDMI Extender Transmitter to the HDMI Extender Receiver located inside the treatment room via a Cat5e/6 cable. Inside the treatment room, the HDMI Extender Receiver is permanently mounted on the wall near the conduit where the Cat5e/6 cable is located. An HDMI cable is used to connect from the output of the HDMI Receiver to the video goggles. Results: This video goggle feedback system is currently being used at two institutions. At one institution, the system was just recently implemented for simulation and treatments on two breath-hold gated patients with 8+ total fractions over a two month period. At the other institution, the system was used to treat 100+ breath-hold gated patients on three Varian TrueBeam linacs and has been operational for twelve months. The average time to prepare the video goggle system for treatment is less than 1 minute. Conclusion: The video goggle system provides an efficient and reliable method to set up a video feedback signal for radiotherapy patients with motion management.

60 APPLIED LIFE SCIENCES↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

Housing Unit Level Social Vulnerability Indices for 2010 and 2020

Housing unit level demographic characteristics for SETX counties. Census years 2010 and 2020. These data are in beta testing stage, designed for use with the SETX-UIFL project. Contact Nathanael Rosenheim (nrosenheim@arch.tamu.edu) for more information. Papers using these data should include Nathanael Rosenheim in the development phase and co-authorship discussions.

Rosenheim, Nathanael↗

3D House (3DH) [SWR-22-83]

The Single-Family and Manufactured Interactive 3D houses can be used as a self-guided learning tool by anyone interested in learning more about retrofit strategies of common weatherization measures. Alternatively, the tool can be used by training organizations for a more structured learning experience when paired with a learning activity or trainer-led demonstration.

Desai, Jal↗

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Pump House in East River Watershed, Colorado 2019-2024

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Pump House at Mount Crested Butte in the East River Watershed. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format ER-X-Y, where ER refers to East River, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, ER-PHS, ER-LMC, ER-LMF, and ER-SMN are associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and ER-RBTn (upslope n=1) are sampling transects during the 2019 Rootball Campaign. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Simulating a Nationally Representative Housing Sample Using EnergyPlus

This report presents a new simulation tool under development at Lawrence Berkeley National Laboratory (LBNL). This tool uses EnergyPlus to simulate each single-family home in the Residential Energy Consumption Survey (RECS), and generates a calibrated, nationally representative set of simulated homes whose energy use is statistically indistinguishable from the energy use of the single-family homes in the RECS sample. This research builds upon earlier work by Ritchard et al. for the Gas Research Institute and Huang et al. for LBNL. A representative national sample allows us to evaluate the variance in energy use between individual homes, regions, or other subsamples; using this tool, we can also evaluate how that variance affects the impacts of potential policies. The RECS contains information regarding the construction and location of each sampled home, as well as its appliances and other energy-using equipment. We combined this data with the home simulation prototypes developed by Huang et al. to simulate homes that match the RECS sample wherever possible. Where data was not available, we used distributions, calibrated using the RECS energy use data. Each home was assigned a best-fit location for the purposes of weather and some construction characteristics. RECS provides some detail on the type and age of heating, ventilation, and air-conditioning (HVAC) equipment in each home; we developed EnergyPlus models capable of reproducing the variety of technologies and efficiencies represented in the national sample. This includes electric, gas, and oil furnaces, central and window air conditioners, central heat pumps, and baseboard heaters. We also developed a model of duct system performance, based on in-home measurements, and integrated this with fan performance to capture the energy use of single- and variable-speed furnace fans, as well as the interaction of duct and fan performance with the efficiency of heating and cooling equipment. Comparison with RECS revealed that EnergyPlus did not capture the heating-side behavior of heat pumps particularly accurately, and that our simple oil furnace and boiler models needed significant recalibration to fit with RECS. Simulating the full RECS sample on a single computer would take many hours, so we used the 'cloud computing' services provided by Amazon.com to simulate dozens of homes at once. This enabled us to simulate the full RECS sample, including multiple versions of each home to evaluate the impact of marginal changes, in less than 3 hours. Once the tool was calibrated, we were able to address several policy questions. We made a simple measurement of the heat replacement effect and showed that the net effect of heat replacement on primary energy use is likely to be less than 5%, relative to appliance-only measures of energy savings. Fuel switching could be significant, however. We also evaluated the national and regional impacts of a variety of 'overnight' changes in building characteristics or occupant behavior, including lighting, home insulation and sealing, HVAC system efficiency, and thermostat settings. For example, our model shows that the combination of increased home insulation and better sealed building shells could reduce residential natural gas use by 34.5% and electricity use by 6.5%, and a 1 degree rise in summer thermostat settings could save 2.1% of home electricity use. These results vary by region, and we present results for each U.S. Census division. We conclude by offering proposals for future work to improve the tool. Some proposed future work includes: comparing the simulated energy use data with the monthly RECS bill data; better capturing the variation in behavior between households, especially as it relates to occupancy and schedules; improving the characterization of recent construction and its regional variation; and extending the general framework of this simulation tool to capture multifamily housing units, such as apartment buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Potential for Energy Retrofits within the City of Sacramento's Rental Housing Inspection Program

This report presents the results of an analysis performed by Pacific Northwest National Laboratory for the City of Sacramento--under the U.S. Department of Energy’s Energy Efficiency and Renewable Energy Office of Weatherization and Intergovernmental Projects Technical Assistance Program--to help determine the potential for incorporating energy efficiency standards into the City’s existing Rental Housing Inspection Program as part of Sacramento’s efforts to create a Climate Action Plan.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Efficiency Integrated Space Conditioning, Water Heating and Air Distribution System for HUD-Code Manufactured Housing

Recognizing the need for new space conditioning and water heating systems for manufactured housing, DeLima Associates assembled a team to develop a space conditioning system that would enhance comfort conditions while also reducing energy usage at the systems level. The product, Comboflair® was defined as a result of a needs analysis of project sponsors and industry stakeholders. An integrated system would be developed that would combine a packaged airconditioning system with a small-duct, high-velocity air distribution system. In its basic configuration, the source for space heating would be a gas water heater. The complete system would be installed at the manufactured home factory and would require no site installation work at the homesite as is now required with conventional split-system air conditioners. Several prototypes were fabricated and tested before a field test unit was completed in October 2005. The Comboflair® system, complete with ductwork, was installed in a 1,984 square feet, double-wide manufactured home built by Palm Harbor Homes in Austin, TX. After the home was transported and installed at a Palm Harbor dealer lot in Austin, TX, a data acquisition system was installed for remote data collection. Over 60 parameters were continuously monitored and measurements were transmitted to a remote site every 15 minutes for performance analysis. The Comboflair® system was field tested from February 2006 until April 2007. The cooling system performed in accordance with the design specifications. The heating system initially could not provide the needed capacity at peak heating conditions until the water heater was replaced with a higher capacity standard water heater. All system comfort goals were then met. As a result of field testing, we have identified improvements to be made to specific components for incorporation into production models. The Comboflair® system will be manufactured by Unico, Inc. at their new production facility in St. Louis, MO. The product will be initially launched in the hot-humid climates of the southern U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Whole-House Design and Commissioning in the Project Home Again Hot-Humid New Construction Community

BSC has been working with Project Home Again since 2008 and has consulted on the design of around 100 affordable, energy efficient new construction homes for victims of hurricanes Katrina and Rita. This report details the effort on the final two phases of the project: Phases V and VI which resulted in a total of 25 homes constructed in 2011. The goal of this project was to develop and implement an energy efficiency package that will achieve at least 20% whole house source energy savings improvement over the B10 Benchmark.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of Carbon Storage Project Public Information Meeting and Open House

The Kentucky Geological Survey (KGS) completed a second phase of carbon dioxide (CO 2 ) injection and seismic imaging in the Knox Group, a Cambrian Ordovician dolomite and sandstone sequence in September 2010. This work completed 2 years of activity at the KGS No. 1 Marvin Blan well in Hancock County, Kentucky. The well was drilled in 2009 by a consortium of State and industry partners (Kentucky Consortium for Carbon Storage). An initial phase of CO 2 injection occurred immediately after completion of the well in 2009. The second phase of injection and seismic work was completed in September 2010 as part of a U.S. DOE funded project, after which the Blan well was plugged and abandoned. Following completion of research at the Blan well, a final public meeting and open house was held in Hancock County on October 28, 2010. This meeting followed one public meeting held prior to drilling of the well, and two on site visits during drilling (one for news media, and one for school teachers). The goal of the final public meeting was to present the results of the project to the public, answer questions, and address any concerns. Despite diligent efforts to publicize the final meeting, it was poorly attended by the general public. Several local county officials and members of the news media attended, but only one person from the general public showed up. We attribute the lack of interest in the results of the project to several factors. First, the project went as planned, with no problems or incidents that affected the local residents. The fact that KGS fulfilled the promises it made at the beginning of the project satisfied residents, and they felt no need to attend the meeting. Second, Hancock County is largely rural, and the technical details of carbon sequestration were not of interest to many people. The county officials attending were an exception; they clearly realized the importance of the project in future economic development for the county.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Best Practices Series - Volume 12: Builders Challenge Guide to 40% Whole-House Energy Savings in the Cold and Very Cold Climates

This best practices guide is the twelfth in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the cold and very cold climates can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and thos erequirements are highlighted in the text. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Builders Challenge↗

Building America Best Practices Series - Volume 11: Builders Challenge Guide to 40% Whole-House Energy Savings in the Marine Climate

This best practices guide is the eleventh in a series of guides for builders produced by the U.S. Department of Energy’s Building America Program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the marine climate (portions of Washington, Oregon, and California) can achieve homes that have whole house energy savings of 40% over the Building America benchmark (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code) with no added overall costs for consumers. These best practices are based on the results of research and demonstration projects conducted by Building America’s research teams. The guide includes information for managers, designers, marketers, site supervisors, and subcontractors, as well as case studies of builders who are successfully building homes that cut energy use by 40% in the marine climate. This document is available on the web at www.buildingamerica.gov. This report was originally cleared 06-29-2010. This version is Rev 1 cleared in Nov 2010.

Builders Challenge↗

Northwest Energy Efficient Manufactured Housing Program: High Performance Manufactured Home Prototyping and Construction Development

The Building America Partnership for Improved Residential Construction, the Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Housing Program (NEEM) administrator, have been collaborating to conduct research on new specifications that would improve on the energy requirements of a NEEM home. In its role as administrator, NEW administers the technical specs, performs research and engineering analysis, implements ongoing construction quality management procedures, and maintains a central database with home tracking. This project prototyped and assessed the performances of cost-effective high performance building assemblies and mechanical systems that are not commonly deployed in the manufacturing setting. The package of measures is able to reduce energy used for space conditioning, water heating and lighting by 50 percent over typical manufactured homes produced in the northwest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Distribution Retrofit Strategies for Affordable Housing

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗