Hydrogen on Venus - Exospheric distribution and escape

The spatial distribution of suprathermal H in the Venus atmosphere is calculated using an approximate numerical solution of the time-independent Boltzmann equation. Sources of suprathermal H are specified on the basis of Pioneer Venus measurements. Reactions involving H2 are neglected. The computed densities of suprathermal H are in satisfactory agreement with profiles derived from analysis of Lyman-alpha airglow by Mariners 5 and 10 and Veneras 11 and 12. The dayside emission at radial distances larger than 18,000 km is attributed to scattering of solar photons by fast H atoms produced primarily on the nightside near midnight. The nightside ionosphere, and consequently the source of suprathermal H, are both expected to vary in response to changes in the solar wind.

Rodriguez, J. M.↗

Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation

Linac4 accelerator of Centre Europeen de Recherches Nucleaires is under construction and a RF-driven H{sup -} ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H{sup -}, electrons, and Cs{sup -} ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

08 HYDROGEN↗

Negative hydrogen ion yields at plasma grid surface in a negative hydrogen ion source

Negative hydrogen (H{sup −}) ion yield from the plasma grid due to incident hydrogen ions and neutrals has been evaluated with the surface collision cascade model, ACAT (Atomic Collision in Amorphous Target) coupled to a negative surface ionization models. Dependence of negative ion fractions upon the velocity component normal to the surface largely affect the calculation results of the final energy and angular distributions of the H{sup −} ions. The influence is particularly large for H{sup −} ions desorbed from the surface due to less than several eV hydrogen particle implact. The present calculation predicts that H{sup −} ion yield can be maximized by setting the incident angle of hydrogen ions and neutrals to be 65 degree. The Cs thickness on the plasma grid should also affect the yields and mean energies of surface produced H{sup −} ions by back scattering and ion induced desorption processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEAR-INFRARED AND MILLIMETER-WAVELENGTH OBSERVATIONS OF Mol 160: A MASSIVE YOUNG PROTOSTELLAR CORE

We have discovered two compact sources of shocked H{sub 2} 2.12 {mu}m emission coincident with Mol 160 (IRAS 23385+6053), a massive star-forming core thought to be a precursor to an ultracompact H II region. The 2.12 {mu}m sources lie within 2'' (0.05 pc) of a millimeter-wavelength continuum peak where the column density is {>=}10{sup 24} cm{sup -2}. We estimate that the ratio of molecular hydrogen luminosity to bolometric luminosity is >0.2%, indicating a high ratio of mechanical to radiant luminosity. CS J = 2{yields}1 and HCO{sup +} J = 1{yields}0 observations with the Combined Array for Research in Millimeter-wave Astronomy (CARMA) indicate that the protostellar molecular core has a peculiar velocity of {approx}2 km s{sup -1} with respect to its parent molecular cloud. We also observed 95 GHz CH{sub 3}OH J = 8{yields}7 Class I maser emission from several locations within the core. Comparison with previous observations of 44 GHz CH{sub 3}OH maser emission shows that the maser sources have a high mean ratio of 95 GHz to 44 GHz intensity. Our observations strengthen the case that Mol 160 (IRAS 23385+6053) is a rapidly accreting massive protostellar system in a very early phase of its evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Limitations of spectral analysis of the Phobos magnetometer data in the search for an intrinsic Martian magnetic field

Both observed and synthetic time series of the magnetic field obtained in circular orbit around Mars by the Phobos spacecraft are analyzed. Of the three reported spectral peaks at 8, 12 and 24 h only the 24-h peak could be due to intrinsic sources. However, 24-h spectral peaks can also be produced in synthetic time series with no intrinsic field effects included. Hence, it is concluded that present spectral analyses of time series obtained with the Phobos magnetometers provide no constraints on the size or the existence of an intrinsic magnetic field at Mars.

Russell, C. T.↗

Negative Hydrogen Ion Source with Inverse Gas Magnetron Geometry

The work is dedicated to the experimental investigation of the intense volume-plasma H{sup -} ion source. Formation of ions occurs in a volume of hydrogen plasma (without additives of cesium) due to two-step dissociative attachment of thermal electrons to vibrationally excited molecules H{sub 2}. Preliminary experimental researches of two parameters of the upgraded source--emission density of H{sup -} ions and gas flow are represented below. The advancing of electrode system of the emission chamber of a source has allowed receiving the value of an emission density of H{sup -} ions equal 440 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

End of Life Decisions for Sealed Radioactive Sources

Sealed radioactive sources are encountered in a wide variety of settings – from household smoke detectors and instrument check sources, through fixed industrial gauges, industrial radiography and well logging sources, to irradiators and medical teletherapy devices. In general, the higher the level of activity in the sealed source, the stricter the regulatory control that is applied to its use, control and ultimate disposition. Lower levels of attention and oversight can and do lead to sources ending up in the wrong place – as orphan sources in uncontrolled storage, disposed in a sanitary landfill, melted down in metal recycling operations and incorporated into consumer products, or handled by an unsuspecting member of the public. There are a range of issues that contribute to the problem of improper disposal of sealed sources, and, in particular, to disused source disposal. General licensed sources and devices are particularly at risk of being disposed incorrectly. Higher activity general licensed sources, although required to be registered with the Nuclear Regulatory Commission (NRC) or Agreement State, receive limited regulatory oversight and are not tracked on a national scale. Users frequently do not consider the full life-cycle costs when procuring sources or devices and discover that they cannot afford to package, transport and dispose of their sources properly. The NRC requirements for decommissioning funding plans and financial assurance are not adequate to cover sealed source transport and disposal costs fully. While there are regulatory limits for storage of disused sources, enforcement is limited and there is no financial incentive for owners to dispose of the sources. In some cases, the lack of availability of approved Department of Transportation (DOT) Type B shipping casks also presents a barrier to sealed source disposal. The report of the Disused Sources Working Group does an excellent job of framing these issues. This article reviews both the issues and the report’s recommendations, which are designed to improve sealed source control and encourage proper disposal of disused sources.

disused source↗

COMPARISON OF THE DIFFUSE H{alpha} AND FUV CONTINUUM BACKGROUNDS: ON THE ORIGINS OF THE DIFFUSE H{alpha} BACKGROUND

We compare the diffuse H{alpha} map of our Galaxy with the FUV (1370-1710 A) continuum map. The H{alpha} intensity correlates well with the FUV intensity. The H{alpha}/FUV intensity ratio increases in general with the H{alpha} intensity and the FUV hardness ratio (1370-1520 A to 1560-1710 A), implying that late OB stars may be the main source of the H{alpha} recombination line at high latitudes. The variation of the H{alpha} intensity as a function of the Galactic latitude is also very similar to that of the FUV intensity. The results likely suggest that not only the original radiation sources of the H{alpha} and FUV backgrounds but also the radiative transfer mechanisms responsible for the diffuse backgrounds are largely common. Therefore, we propose a scenario wherein the H{alpha} background at high latitudes is mostly composed of two components, H{alpha} photons produced by in situ recombination at the ionized regions around late OB stars and dust-scattered light of the H{alpha} photons originating from late OB stars.

79 ASTRONOMY AND ASTROPHYSICS↗

ALMA observation of the 658 GHz vibrationally excited H{sub 2}O maser in Orion KL source I

We present an observational study of the vibrationally excited H{sub 2}O line at 658 GHz (ν{sub 2} = 1, 1{sub 1,0}-1{sub 0,1}) toward Orion KL using the Atacama Large Millimeter/Submillimeter Array (ALMA). This line is clearly detected at the position of the massive protostar candidate, Source I. The spatial structure is compact, with a size of about 100 AU, and is elongated along the northeast–southwest low-velocity (18 km {sup −1}) bipolar outflow traced by 22 GHz H{sub 2}O masers, SiO masers, and thermal SiO lines. A velocity gradient can be seen perpendicular to the bipolar outflow. The overall spatial and velocity structure seems to be analogous to that of the 321 GHz H{sub 2}O maser line previously detected with ALMA and vibrationally excited SiO maser emission. The brightness temperature of the 658 GHz H{sub 2}O line is estimated to be higher than 2 × 10{sup 4} K, implying that it is emitted via maser action. Our results suggest that the 658 GHz H{sub 2}O maser line is emitted from the base of the outflow from a rotating and expanding accretion disk as observed for the SiO masers and the 321 GHz H{sub 2}O maser. We also search for two other H{sub 2}O lines at 646 GHz (9{sub 7,3}-8{sub 8,0} and 9{sub 7,2}-8{sub 8,1}), but they are not detected in Orion KL.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of optical emission from the hydrogen plasma of the Linac4 ion source and the SPL plasma generator

At CERN, a non caesiated H{sup -} ion volume source derived from the DESY ion source is being commissioned. For a proposed High Power Superconducting Proton Linac (HP-SPL), a non caesiated plasma generator was designed to operate at the two orders of magnitude larger duty factor required by the SPL. The commissioning of the plasma generator test stand and the plasma generator prototype are completed and briefly described. The 2 MHz RF generators (100 kW, 50 Hz repetition rate) was successfully commissioned; its frequency and power will be controlled by arbitrary function generators during the 1 ms plasma pulse. In order to characterize the plasma, RF-coupling, optical spectrometer, rest gas analyzer and Langmuir probe measurements will be used. Optical spectrometry allows direct comparison with the currently commissioned Linac4 H{sup -} ion source plasma. The first measurements of the optical emission of the Linac4 ion source and of the SPL plasma generator plasmas are presented.

43 PARTICLE ACCELERATORS↗

Direct observation of roaming radicals in the thermal decomposition of acetaldehyde.

The thermal dissociation of acetaldehyde has been studied with the reflected shock tube technique using H(D)-atom atomic resonance absorption spectrometry detection. The use of an unreversed light source yields extraordinarily sensitive H atom detection. As a result, we are able to measure both the total decomposition rate and the branching to radical versus molecular channels. This branching provides a direct measure of the contribution from the roaming radical mechanism since the contributions from the usual tight transition states are predicted by theory to be negligible. The experimental observations also provide a measure of the rate coefficient for H + CH{sub 3}CHO. Another set of experiments employing C{sub 2}H{sub 5}I as an H-atom source provides additional data for this rate coefficient that extends to lower temperature. An evaluation of the available experimental results for H + CH{sub 3}CHO can be expressed by a three-parameter Arrhenius expression as k = 7.66 x 10{sup -20}T{sup 2.75} exp((-486 K)/T) cm{sup 3} molecule{sup -1} s{sup -1} (298-1415 K). Analogous experiments employing C{sub 2}D{sub 5}I as a D-atom source allow for the study of the isotopically substituted reaction. The present experiments are the only direct measure for this reaction rate constant, and the results can be expressed by an Arrhenius expression as k = 5.20 x 10{sup -10} exp((-4430 K)/T) cm{sup 3} molecule{sup -1} s{sup -1} (1151-1354 K). The H/D + CH{sub 3}CHO reactions are also studied with ab initio transition-state theory, and the results are in remarkably good agreement with the current experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long Pulse H{sup -} Beam Extraction With A RF Driven Ion Source With Low Fraction Of Co-Extracted Electrons

IPP Garching is developing H{sup -}/D{sup -} RF ion sources for the ITER neutral beam system. On the MANITU testbed the experiments are focussed on long pulse H{sup -}/D{sup -} beam extraction with a 100 kW prototype source. The negative ion production is based on surface conversion of atoms and positive ions on Caesium layers. In long pulses with H{sup -} beam extraction the ion currents were stable but with too high fraction of co-extracted electrons. The electron current could be lowered considerably by avoiding copper impurities from the Faraday screen in the plasma which was achieved by coating of the inner surfaces of the source with Molybdenum. A positive bias potential with respect to the source applied to the plasma grid, the bias plate or to a metal rod installed near the plasma grid enables regulation of the electron current during long pulses. In this way low values consistent with the ITER requirements can be achieved without significant loss of ion current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Li{sup +} ion emission from a hot-plate alumina-silicate source stimulated by flash heating with an infrared laser

The Neutralized Drift Compression Experiment-II accelerator under construction at Lawrence Berkeley National Laboratory has been designed to employ a lithium-doped alumino-silicate (Al-Si) hot-plate surface-ionization ion source. In order to achieve the design 1 mA/cm{sup 2} current density, the emitter must be constantly kept at a high temperature, leading to the accelerated loss of Li material as ions or neutrals. As a result, the estimated lifetime of the source is 50 h. This lifetime can be extended if the source is kept at low temperature during standby, and pulse heated to the high temperature during the ion extraction phase only. A pulsed heating technique based on an infrared laser (CO{sub 2} gas discharge, {lambda}= 10.6 {mu}m) is described in this paper. The feasibility of ion current emission stimulated by flash heating with an infrared (IR) laser was demonstrated. High repeatability of the laser-stimulated ion current was observed, creating an opportunity for modulation and gating of the ion current with a laser pulse. It was found that with the available low power ({approx_equal}115 W/cm{sup 2}) IR laser, current densities as high as 0.8 mA/cm{sup 2} could be achieved with a 2.8 mm diameter source. Various approaches for scaling to a larger (10 cm diameter) source and the application of short pulse, high power lasers are discussed. The results and conclusions of this paper may apply to various species of hot-plate ion sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimum plasma grid bias for a negative hydrogen ion source operation with Cs

The functions of a biased plasma grid of a negative hydrogen (H{sup −}) ion source for both pure volume and Cs seeded operations are reexamined. Proper control of the plasma grid bias in pure volume sources yields: enhancement of the extracted negative ion current, reduction of the co-extracted electron current, flattening of the spatial distribution of plasma potential across the filter magnetic field, change in recycling from hydrogen atomic/molecular ions to atomic/molecular neutrals, and enhanced concentration of H{sup −} ions near the plasma grid. These functions are maintained in the sources seeded with Cs with additional direct emission of negative ions under positive ion and neutral hydrogen bombardment onto the plasma electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source

A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20–40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, −2 to −4 kV, and 0 kV, respectively. The total ion beam current of 30–40 mA is recorded on Faraday cup at 40 keV of beam energy at 600–1000 W of microwave power, 800–1000 G axial magnetic field and (1.2–3.9) × 10{sup −3} mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.