Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physics vs structure: A systematic benchmark of learning strategies for multi-zone building thermal dynamics

Recent advances in physics-informed and data-driven machine learning promise improved thermal models for advanced building control, yet there is limited quantitative evidence on when added physics structure and architectural complexity are beneficial. Here, this work presents a systematic benchmark of five representative system identification methods for modeling multi-zone building thermal dynamics: linear state-space models, multi-layer perceptrons, neural state-space models, neural ordinary differential equations, and physically-consistent neural networks. The methods are evaluated across multiple data regimes and zone coupling strategies. Using a high-fidelity multi-zone commercial building emulator, we examine short-term and long-term prediction accuracy, computational efficiency, and ease of development. Our results reveal critical trade-offs between prediction performance, model complexity, and physical consistency. We demonstrate that decoupled, nonlinear black-box models consistently outperform coupled physics-constrained architectures in both predictive accuracy and out-of-distribution robustness in majority of the test cases for the building type considered in the study. Our findings quantify the cost of complexity in building thermal modeling and provide concrete, actionable, scenario-based guidelines for selecting model classes for control-oriented applications.

Building thermal modeling↗

Statorless mixed flow turbine for transonic pulsating inflow

Effective harvesting of power from high speed highly transient inflows such as the outflow of rotating detonation combustors (RDCs) is key to achieving their promised cycle efficiency step jump. To increase power density and efficiency simultaneously, a concept that can directly ingest transonic outflow, addressing the choking is needed, i.e. without additional transition elements. A new statorless design was assessed using a comprehensive approach to quantify all contributions to loss generation in transient flows, locally and globally. The turbine rotor was designed under steady flow conditions with a genetic algorithm. The comparison of power and loss generation between steady and unsteady flow results shows that a design methodology under steady-state conditions is suitable to characterize the performance of different designs. Three design families were further assessed under highly transient transonic conditions including traveling shock waves with a relative total pressure amplitude of 149.6% around the mean value and inflow angle variations from -26.5 deg to +51.8 deg. The oblique shock impinging on the pressure side (PS) of the turbine augments the shaft power extraction. When the oblique shock reflects between the pressure side and suction side (SS), its strength diminishes. This paper provides design guidelines on efficient turbine work extraction from the shocks emanating from detonation combustors.

rotating detonation engines↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Large eddy simulation of wind farm performance in horizontally and vertically staggered layouts

This numerical investigation employs Large Eddy Simulation (LES) coupled with Actuator Disk Model (ADM) to evaluate wind farm layout optimization strategies. The study presents a systematic analysis of aligned, horizontal staggering, vertical staggering, and mixed (combination of horizontal and vertical) staggering configurations, aiming to establish optimal design parameters for enhanced power production. The investigation examines key performance metrics including mean velocity distributions, turbulence intensity characteristics, and power generation efficiency. Results demonstrate better performance of both horizontal and vertical staggering patterns compared to conventional aligned configurations, with horizontal staggering exhibiting notably higher power output than vertical arrangements. Our findings also suggest that mixed configurations, incorporating both horizontal and vertical staggering, can offer optimal performance characteristics. As a result, this research advances the understanding of wake interactions in complex wind farm layouts and provides design guidelines for maximizing wind farm power generation efficiency through strategic turbine positioning.

17 WIND ENERGY↗

A review of United States energy-only generator interconnection service policy and considerations for reform

Grid interconnection has emerged as a significant obstacle to the development of new electricity resources. There is growing interest in energy-only interconnection, which is an interconnection service option meant to allow the interconnection of new generators without ensuring their energy deliverability during all hours through the transmission system to customers. This approach potentially avoids upfront congestion-related transmission upgrades but could increase curtailment risk. Interest in energy-only interconnection is shaped by incomplete understanding of how interconnection policy functions in different jurisdictions, a knowledge gap that makes it difficult to determine how energy-only interconnection might be better used or re-designed. In this paper, we provide a regulatory review of energy-only interconnection in U.S. interconnection policy and practice, identifying jurisdictions in which rules are close to -or farther from-the theoretical concept of energy-only interconnection service. We find substantial jurisdictional differences in how energy-only interconnection is implemented, driven by differences in resource adequacy frameworks, real-time transmission operations, and state-level procurement practices. U.S. regulators have preferred local jurisdictional flexibility over federal prescription of interconnection study methods and procedures, which also contributes to differences among regions. Such findings raise fundamental questions about whether competition policies in electricity markets should extend beyond spot energy markets and into more prescriptive guidelines around interconnection rules and market entry. This paper sheds light on tensions that energy-only interconnection raises in allowing generators to access the transmission system on an as available basis and discusses how controlling thresholds for congestion-related network upgrades may be a barrier to electricity market entry.

Gorman, Will↗

Probing degradation at solid-state battery interfaces using machine-learning interatomic potential

Solid-state batteries featuring fast ion-conducting solid electrolytes are promising next-generation energy storage technologies, yet challenges remain for practical deployment due to electro-chemo-mechanical instabilities at solid-solid interfaces. These interfaces, which include homogeneous/internal interfaces such as grain boundaries (GBs) and heterogeneous/external interfaces between solid-electrolyte and electrode materials, can impede Li-ion transport, deteriorate performance, and eventually lead to cell failure. Here, in this study, we leverage large-scale molecular simulations, enabled by validated machine-learning interatomic potentials, to directly probe the onset of interfacial degradation at the garnet Li 7 La 3 Zr 2 O 12 (LLZO) solid-electrolyte/LiCoO 2 (LCO) cathode interface. By surveying different interfacial geometries and compositions, it is found that Li-deficient interfaces can lead to severe interfacial disordering with cation mixing and Co interdiffusion from LCO into LLZO. By contrast, Li-sufficient interfaces are less disordered, although elemental segregation with local ordering is observed. As a consequence of Co interdiffusion, Co-rich regions are formed at the GBs of LLZO due to cation segregation and trapping effects. This behavior is independent of the GB tilting axis, degree of disorder at the GBs, and Co concentration, which implies Co clustering at GBs is a general phenomenon in polycrystalline LLZO and can dictate its overall transport and mechanical properties. Our findings elucidate the underlying fundamental mechanisms that give rise to experimentally observed physicochemical properties and provide guidelines for interface design that can mitigate interfacial degradation and improve cycling performance.

25 ENERGY STORAGE↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Finite element procedure for thermomechanical and structural integrity analysis of beam intercepting devices subjected to free electron laser

High-energy particles, including photons (x-ray, γ-ray, bremsstrahlung), electrons, and protons, possess the capability to penetrate materials and deposit energy within them. The degree of absorption depends on both the energy and type of particles, as well as the properties of the materials with which they interact. This energy deposition can manifest either at the material's surface or throughout its volume, potentially resulting in various failure modes. The primary aim of this paper is to establish a structured analysis methodology for evaluating the structural integrity of beam-intercepting devices when subjected to high-energy particles. Here, the paper also reviews some of the underlying physics, pertinent to the scope of the thermomechanical analysis, potential failure modes, and introduces verification and validation methodologies. Engineers and researchers can utilize the guidelines presented in this paper to effectively plan the development of beam intercepting devices, thereby ensuring their reliability and performance in the presence of high-energy particle exposure.

Finite element analysis↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗

An Evaluation of the Global Effects of Tritium Emissions from Nuclear Fusion Power

We report that tritium, like all hydrogen isotopes, is difficult to confine and easily diffuses through most materials. As currently planned, fusion power plants will process and handle large quantities of deuterium and tritium as fuel, and therefore, will become sources of tritium input into the environment. Tritium releases from a worldwide distribution of tritium sources (fusion or fission) will lead to higher tritium levels overall and have global impact. This report investigates the hydrologic partitioning of yearly tritium releases assuming 1 g/yr loss per 500 MW of nuclear power generation for varying scales of power generation. On large scales, it is found that the worldwide average levels of tritium could exceed some public health goals and regulatory guidelines. Tritium concentrations at such levels may also have other impacts on the environment through increased ion-pair generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A missing layer in COVID-19 studies: Transmission of enveloped viruses in mucus-rich droplets

Here we evaluate the influence of mucus layers on the evaporation time and transport of enveloped viruses, including SARS-CoV-2. Enveloped viruses must remain moist to be fully infective. Yet, the Wells model based on water droplets divides respiratory droplets into either quickly evaporated aerosolized particles termed droplet nuclei (<10 s) or liquid droplets that fall to the nearest surface, leaving no physical mechanism for airborne transmission of fully infective enveloped viruses over large distances (greater than a few meters). Yet, the role of mucus layers on evaporation times has not been considered even though the formation of mucus shells around liquid cores of respiratory droplets has been shown experimentally. Here we show that mucus shells increase the drying time by orders of magnitude so that enveloped virions may remain well hydrated and, thus, fully infective at substantial distances. Further, this provides a mechanism by which infective enveloped virus particles can transmit as aerosols within buildings and between buildings over extended distances. This analysis is important because public health agencies typically follow the Wells model to establish health policies including social/physical distancing guidelines.

60 APPLIED LIFE SCIENCES↗

Isotherm modeling and techno-economic analysis of a TSA moving bed process using a tetraamine-appended MOF for NGCC applications

Tetraamine-appended metal-organic frameworks (MOF) are a new family of amine-functionalized MOF materials that show potential for CO 2 capture from flue gas conditions relevant to natural gas combined cycle (NGCC) power plants. This work presents isotherm modeling of the tetraamine-appended MOF Mg 2 (dobpdc)(3-4-3)(dobpdc 4- =4,4'-dioxidobiphenyl-3,3'dicarboxylate;3-4-3=N,N'bis(3-aminopropyl)-1,4-diaminobutane), process modeling, scale up, and a techno-economic optimization of a moving bed Temperature Swing Adsorption (TSA) process for carbon capture using this sorbent. This MOF exhibits a unique two-step CO 2 adsorption profile in three different pressure ranges. Thus, arctangent-based logistic functions and, quadratic and Langmuir models were employed to represent such isotherm behavior. The results of the isotherm model show good fitting vs the experimental data with an RMSE of 0.41. Here, to model the carbon capture process, the isotherm model was embedded into a moving bed contactor model, and this was used to simulate a TSA CO 2 capture cycle and evaluate cost-optimal designs considering flue gas from a -650 MWe NGCC power plant. The capital cost model consists of CAPEX correlations for reactors, compressors, ducting, etc., while the operating costs include steam, water, chemicals, and electricity (following NETL's quality guidelines for energy systems studies). A techno-economic optimization of the capture system was performed by using NETL's Framework for the Optimization and Quantification of Uncertainty and Surrogates tool (FOQUS). Results suggest that a moving bed carbon capture system with tetraamine-appended MOF can be competitive compared to conventional MEA solvent-based capture processes for NGCC plants, when a heat recovery efficiency of at least 40% is achieved, and MOF materials can be produced at a cost below -$9/kg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗