Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Surface Trap Dynamics and Gamma‐Ray Detection Enhancement in Passivated FAPbBr 3 Perovskite Crystals

Perovskite‐based direct radiation detectors offer a compelling platform for room‐temperature gamma spectroscopy due to their high sensitivity, tunable optoelectronic properties, and compatibility with solution processing. While prior studies on formamidinium lead tribromide (FAPbBr 3 ) have shown that surface passivation mitigates deep trap state impact on the charge collection efficiency (CCE), the influence of surface‐based shallow traps on time‐resolved detector response remains largely unexplored. In this article, a digital signal processing (DSP) method is applied to analyze waveform rising edge dynamics in FAPbBr 3 single‐crystal detectors, identifying prompt and delayed charge collection components. Using the second derivative of the collected charge signal, the onset of shallow trap reemission is isolated, occurring 1.1 µs after carrier generation. Surface passivation suppressed deep trap states, shifting carrier occupancy toward shallower traps and extending the temporal window of delayed charge collection. This delayed contribution correlates with measurable changes in the temporal and amplitude distributions of detector events. By leveraging time‐domain filtering informed by these dynamics, a selective enhancement in signal quality and gamma peak‐to‐Compton ratio (PCR) is achieved, while preserving over 90% of photoelectric events. An improvement in the PCR to 1.80, from the original 1.09, is enabled by focusing on high collection efficiency events corresponding to reemitted carriers in the 1.1 to 3 µs range after the generation event. These results demonstrate a pathway for leveraging shallow trap dynamics to enhance spectral fidelity in time‐resolved perovskite detectors.

36 MATERIALS SCIENCE↗

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219↗

Interaction of hydrogen chloride with alumina

The influence of temperature, pressure, and outgas conditions on the absorption of hydrogen chloride and water vapor on both alpha and gamma alumina was studied. Characterization of the adsorbents was performed using X-ray powder diffraction, scanning electron microscopy (SEM), low temperature nitrogen adsorption desorption measurements, BET nitrogen surface area measurements and electron spectroscopy for chemical analysis (ESCA). Water vapor adsorption isotherms at 30, 40, and 50 C were measured on alpha and gamma alumina after outgassing at 80, 200, and 400 C. Both outgas temperature and adsorption temperature influenced the adsorption of water vapor on the aluminas. The water vapor adsorption was completely reversible. Alpha alumina absorbed more water per unit area than gamma alumina. Differences in the adsorption capacity for water vapor of the two aluminas were explained on the basis of ideal surface models of alpha and gamma alumina. Isosteric heats of adsorption for water vapor on the aluminas were determined over a limited range of surface coverage.

Bailey, R. R.↗

Preface to the Special Issue on Signal Processing, Data Acquisition and Front-end Systems for Radiation Detection and Measurements

This special issue of the Journal of Signal Processing Systems focuses on advancement of signal processing and data-acquisition for radiation detection and measurements. The seven articles included cover diverse topics within the scope of radiation detection ranging from understanding of fundamental fission process, instrumentation, and application of radiation interaction (e.g., tomography and imaging). The articles focus on signal processing for fission spectrometer, neutron and gamma-ray computed tomography and artificial intelligence methods, dynamic neutron imaging system, pulse-pileup correction in x-ray spectroscopy and calibration methods in radiation measurement.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Three-dimensional diagnostics and measurements of inertial confinement fusion plasmas

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium–tritium plasma undergoing fusion (“hotspot”), v HS . Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide v HS to better than 1 part in 10 4 and enable cross correlations with other measurements. Here we present the impact of v HS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

47 OTHER INSTRUMENTATION↗

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗

The Distant, Galaxy Cluster Environment of the Short GRB 161104A at $z\sim 0.8$ and a Comparison to the Short GRB Host Population

We present optical observations of the Swift short-duration gamma-ray burst (GRB) GRB 161104A and its host galaxy at z = 0.793 ± 0.003. We model the multiband photometry and spectroscopy with the stellar population inference code Prospector and explore the posterior using nested sampling. We find a mass-weighted age of $t_m = 2.12^{+0.23}_{-0.21}$ Gyr, stellar mass of log(M/M ⊙ ), metallicity of log(Z/Z ⊙ ), dust extinction of $A_V = 0.08^{+0.08}_{-0.05}$, and low star formation rate of 9.9 × 10 -2 M ⊙ yr -1 . These properties, along with a prominent 4000 Å break and optical absorption lines, classify this host as an early-type, quiescent galaxy. Using Dark Energy Survey galaxy catalogs, we demonstrate that the host of GRB 161104A resides on the outskirts of a galaxy cluster at z ≈ 0.8, situated ≈1 Mpc from the likely brightest cluster galaxy. We also present new modeling for 20 additional short GRB hosts (≈33% of which are early-type galaxies), finding population medians of and $t_m = 1.07^{+1.98}_{-0.67}$ Gyr (68% confidence). We further find that the host of GRB 161104A is more distant, less massive, and younger than the four other short GRB hosts known to be associated with galaxy clusters. Cluster short GRBs have faint afterglows, in the lower ≈11% (≈30%) of observed X-ray (optical) luminosities. We place a lower limit on the fraction of short GRBs in galaxy clusters versus those in the field of ≈5%–13%, consistent with the fraction of stellar mass of ≈10%–20% in galaxy clusters at redshifts 0.1 ≤ z ≤ 0.8. Future studies that take advantage of wider-field and deeper cluster surveys are needed to understand the true rate of short GRBs in clusters and their effect on heavy-element enrichment in the intracluster medium.

79 ASTRONOMY AND ASTROPHYSICS↗

INTEGRAL reloaded: Spacecraft, instruments and ground system

The European Space Agency’s INTErnational Gamma-Ray Astrophysics Laboratory (ESA/INTEGRAL) was launched aboard a Proton-DM2 rocket on 17 October 2002 at 06:41 CEST, from Baikonur in Kazakhstan. Since then, INTEGRAL has been providing long, uninterrupted observations (up to about 47 h, or 170 ksec, per satellite orbit of 2.7 days) with a large field-of-view (FOV, fully coded: 100 deg), millisecond time resolution, keV energy resolution, polarization measurements, as well as additional wavelength coverage at optical wavelengths. This is realized by two main instruments in the 15 keV to 10 MeV energy range, the spectrometer SPI (spectral resolution 3 keV at 1.8 MeV) and the imager IBIS (angular resolution: 12 arcmin FWHM), complemented by X-ray (JEM-X; 3–35 keV) and optical (OMC; Johnson V-band) monitor instruments. All instruments are co-aligned to simultaneously observe the target region. A particle radiation monitor (IREM) measures charged particle fluxes near the spacecraft. The Anti-coincidence subsystems of the main instruments, built to reduce the background, are also very efficient all-sky γ-ray detectors, which provide virtually omni-directional monitoring above ~75 keV. Besides the long, scheduled observations, INTEGRAL can rapidly (within a couple of hours) re-point and conduct Target of Opportunity (ToO) observations on a large variety of sources. INTEGRAL observations and their scientific results have been building an impressive legacy: The discovery of currently more than 600 new high-energy sources; the first-ever direct detection of (56)Ni and (56)Co radio-active decay lines from a Type Ia supernova; spectroscopy of isotopes from galactic nucleo-synthesis sources; new insights on enigmatic positron annihilation in the Galactic bulge and disk; and pioneering gamma-ray polarization studies. INTEGRAL is also a successful actor in the new multi-messenger astronomy introduced by non-electromagnetic signals from gravitational waves and from neutrinos: INTEGRAL found the first prompt electromagnetic radiation in coincidence with a binary neutron star merger. Up to now more than 1750 scientific papers based on INTEGRAL data have been published in refereed journals. In this paper, we will give a comprehensive update of the satellite status after more than 18 years of operations in a harsh space environment, and an account of the successful Ground Segment.

Erik Kuulkers↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

High energy spectroscopy with the AXAF

The AXAF is a meter-class telescope that is planned to be the third of NASA's Great Observatories, joining the Hubble Space Telescope and the Compton Gamma Ray Observatory in orbit before the end of this decade. The telescope will approach tenth-arc-second resolution over a dynamic range of 100 (0.1-10 keV). An assortment of gratings and focal plane detectors will be utilized to provide unprecedented imaging and spectroscopic capabilities in a long-lived facility. In particular, the AXAF is unique in its high resolution imaging, and in the hard X-ray spectroscopy that can be performed with both high resolution and high throughput.

Holt, S. S.↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

PING Gamma Ray and Neutron Measurements of a Meter-Sized Carbonaceous Asteroid Analog

Determining the elemental composition of carbonaceous (spectral type C) asteroids is still one of the basic problems when studying these objects. The only main source of elemental composition information for asteroids is from their optical, NIR and IR properties, which include their spectral reflectance characteristics, albedo, polarization, and the comparison of optical spectroscopy with meteorite groups corresponding to asteroids of every spectral type. Unfortunately, these sources reflect observations from widely contrasting spatial scales that presently yield a void in the continuum of microscopic and macroscopic evidence, a lack of in situ measurement confirmation, and require deeper sensing techniques to discern the nature of these asteroids. The Probing In situ with Neutrons and Gamma rays (PING) instrument is ideally suited to address this problem because it can be used to determine the bulk elemental composition, H and C content, the average atomic weight and density of the surface and subsurface layers of C-type asteroids, and can provide measurements used to determine the difference between and distinguish between different types of asteroids. We are currently developing the PING instrument that combines gamma ray and neutron detectors with a 14 Me V pulsed neutron generator to determine the in-situ bulk elemental abundances and geochemistry of C-type asteroids with a spatial resolution of 1 m down to depths of tens of cm to 1 m. One aspect of the current work includes experimentally testing and optimizing PING on a known meter-sized Columbia River basalt C-type asteroid analog sample that has a similar composition and the same neutron response as that of a C-type asteroid. An important part of this effort focuses on utilizing timing measurements to isolate gamma rays produced by neutron inelastic scattering, neutron capture and delayed activation processes. Separating the gamma ray spectra by nuclear processes results in higher precision and sensitivity elemental composition measurements. Using gated data acquisition techniques allows for the unambiguous identification of gamma ray lines from different isotopes and nuclear processes, especially in situations when limited detector resolution results in overlapping gamma ray lines that cannot be individually resolved. In this paper, we will present the PING basalt layering experimental data, taken at the test facility at NASA Goddard Space Flight Center using the time tagged event-by-event data analysis technique, compared to our MCNPX computer simulation results for the C-type asteroid and basalt layering simulant models. Comparison of these data will show the advantages, validity, and measurement sensitivity of PING's nuclear interrogation methods to obtain more precise and sensitive in situ bulk elemental composition and density measurements of the subsurface of asteroids.

Bodnarik, J.↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Workshop on Impulsive Solar Flares, 2nd, University of New Hampshire, Durham, Sept. 26-28, 1988, Proceedings

Papers on impulsive solar flares are presented, covering topics such as the optical properties of impulsive flares, soft X-ray spectroscopy of solar flares, the energy release process in impulsive bursts, high-velocity evaporation and a high-speed shock wave during the impulsive phase of the April 24, 1984 flare, nonpotential magnetic fields at sites of gamma-ray flares, and meter-decimeter and microwave radio observations of solar flares. Other topics include rise times in solar radio bursts, removal of the gradual component in analyses of solar impulsive bursts, ion and relativistic electron transport in solar flares, neutrons and gamma-ray emission on June 3, 1982, emission characteristics of three intense solar flares in cycle 21, and solar flare gamma-ray observations with the Hinotori satellite. Additional topics include spectra of relativistic solar proton ground-level events recorded in Antarctica, a 153-d periodicity in the occurrence of solar flares producing energetic interplanetary electrons, a search for solar neutron response in neutron monitor data, neutral beams in two-ribbon flares and in the geomagnetic tail, beam heating in solar flares, and solar flare gamma-ray line shapes.

Source record↗

Fermi GBM Observations of Terrestrial Gamma Flashes

In its first two years of operation, the Fermi Gamma Ray Burst Monitor (GBM) has observed 79 Terrestrial Gamma Flashes (TGFs). The thick Bismuth Germanate (BGO) detectors are excellent for TGF spectroscopy, having a high probability of recording the full energy of an incident photon, spanning a broad energy range from 150 keV to 40 MeV, and recording a large number of photons per TGF. Correlations between GBM TGF triggers and lightning sferics detected with the World-Wide Lightning Location Network indicate that TGFs and lightning are simultaneous to within tens of microseconds.

Wilson-Hodge, Colleen A.↗

Science Capabilities of the GLAST Burst Monitor

The Large Area Telescope (LAT) on GLAST will make pioneering observations of gamma-ray bursts in the energy range above about 20 MeV. The primary function of the GLAST Burst Monitor (GBM) is to extend the energy range for GRB observations down to about 10 keV, allowing time-resolved spectroscopy over an energy range of six decades or more for strong bursts. The GBM will also generate alerts for strong bursts outside the LAT field-of-view, permitting re-orientation of the spacecraft so that the LAT can observe prompt or delayed high-energy emission. Burst locations will be disseminated rapidly to ground observers. The GBM will also provide data suitable for a variety of other studies, including discovery of gamma-ray transient sources, monitoring of Soft Gamma Repeaters, and observations of solar flares.

Meegan, Charles↗