Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally graded materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Experimental Investigation of Gas/Slag/Matte/Tridymite Equilibria in the Cu-Fe-O-S-Si System in Controlled Gas Atmospheres: Experimental Results at 1473 K (1200 °C) and P(SO{sub 2}) = 0.25 atm

Experimental studies were undertaken to determine the gas/slag/matte/tridymite equilibria in the Cu-Fe-O-S-Si system at 1473 K (1200 °C), P(SO{sub 2}) = 0.25 atm, and a range of P(O{sub 2})’s. The experimental methodology involved high-temperature equilibration using a substrate support technique in controlled gas atmospheres (CO/CO{sub 2}/SO{sub 2}/Ar), rapid quenching of equilibrium phases, followed by direct measurement of the chemical compositions of the phases with Electron Probe X-ray Microanalysis (EPMA). The experimental data for slag and matte were presented as a function of copper concentration in matte (matte grade). The data provided are essential for the evaluation of the effect of oxygen potential under controlled atmosphere on the matte grade, liquidus composition of slag and chemically dissolved copper in slag. The new data provide important accurate and reliable quantitative foundation for improvement of the thermodynamic databases for copper-containing systems.

36 MATERIALS SCIENCE↗

Influence of printing parameters on the mechanical behavior of 3D-printed SS316L parts manufactured using laser hot wire directed energy deposition

Hybrid manufacturing combines the simultaneous benefits of additive manufacturing (complex geometries, part consolidation, and mass customization) with the advantages of subtractive manufacturing (superior surface finish and enhanced dimensional accuracies) by integrating a suite of complementary traditional processes into a base platform of additive manufacturing. The use of hybrid technology has grown in recent years given its capabilities on repairing metallic structures, producing parts with conformal cooling features, and manufacturing functionally graded products. These kinds of capabilities are of great interest to the medical implant, energy, automotive, maritime, and aerospace industry sectors, among many other fields. This work investigated the mechanical properties of stainless steel (SS) 316L as a function of different tool paths strategies using an integrated 5-axis CNC hybrid Mazak system with a laser hot wire deposition system (LHWDS). This study includes the evaluation of different printing parameters and their impact on the quality of the printed bead as well as the incorporation of a structure–property material relationship based on the mechanical performance of the manufactured coupons.

36 MATERIALS SCIENCE↗

Joining of Ni-TiC FGM and Ni-Al Intermetallics by Centrifugal Combustion Synthesis

A centrifugal combustion synthesis (CCS) process has been investigated to join a Ni-Al intermetallic compound and a Ni-TiC cermet. The cermet, a tubular graphite mold, and a green compact of reactants consisting of Al, Ni and NiO were set in a centrifugal caster. When the combustion synthesis reaction was induced in the centrifugal force field, a synthesized molten Ni-Al alloy flowed into the graphite mold and joined to the cermet. The soundness of the joint interface depended on the volume percentage of TiC phase in the cermet. A lot of defects were formed near the interface between the Ni-TiC cermet and the cast Ni-Al alloy when the volume percentage of TiC was 50% or higher. For this kind of cermet system, using a functionally graded cermet such as Ni-10 vol.%TiC/Ni-25 vol.%TiC/Ni-50 vol.%TiC overcame this difficulty. The four-point bending strength of the joined specimen consisting of the three-layered FGM cermet and cast Ni-29 mol%Al alloy was 1010 MPa which is close to the result for a Ni-29 mol%Al alloy specimen.

36 MATERIALS SCIENCE↗

MATERIAL CONTROL ACCOUNTING INMM

Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

99 GENERAL AND MISCELLANEOUS↗

Additive Manufacturing of Ultrahigh Temperature Refractory Metal Alloys

The project advances the manufacture of RMA for ultrahigh-temperature service with three main innovations: a thermodynamically derived high-throughput AM synthesis and characterization using reactive synthesis of elemental powders, a new dimensional number to predict processing parameters, and a novel processing scheme for the fabrication of components with functional grading microstructures. With these advances, the project demonstrates in Phase I the manufacture of RMAs exhibiting room temperature compression ductility above 20%, room temperature fracture toughness above 10 MPam 0.5 , and the fabrication of tensile test samples that have a transformative impact on the manufacturing of RMAs by enabling cost-efficient and large-scale fabrication of components.

33 ADVANCED PROPULSION SYSTEMS↗

Oak Ridge National Laboratory Thermoplastic Composite Joining of Pultruded Continuous Fiber Spars for Multi-Functional Battery Enclosure

Oak Ridge National Laboratory (ORNL) worked with DowAksa Industry to investigate the potential of using PA66 material to produce larger composite parts, transcending the limitations of traditional presses. The project aimed to develop a suitable material for printing battery boxes using Nylon 66 infused with 40 wt.% carbon fiber, compatible with the ORNL Additive Manufacturing and Compression Molding (AM-CM) system. However, even with extensive work, it was concluded that the material is not compatible with the AMCM process and suitable for joining using compression technique. Main reason for the incompatibility were found to be very high crystallinity of the PA66 grade chosen for this work. To improve printability, a modifier (proprietary) was added to decrease crystallinity, but this led to reduced thermal stability and adhesion issues.

36 MATERIALS SCIENCE↗

Patterns of Response After Preoperative Intensity-Modulated Radiation Therapy and Capecitabine/Oxaliplatin in Rectal Cancer: Is There Still a Place for Ecoendoscopic Ultrasound?

Purpose: The main goals of preoperative chemoradiotherapy (CHRT) in rectal cancer are to achieve pathological response and to ensure tumor control with functional surgery when possible. Assessment of the concordance between clinical and pathological responses is necessary to make decisions regarding alternative conservative procedures. The present study evaluates the patterns of response after a preoperative CHRT regimen, and the value of endoscopic ultrasound (EUS) in assessing response. Methods and Materials: A total of 51 EUS-staged T3 to T4 and/or N0 to N+ rectal cancer patients received preoperative CHRT (intensity-modulated radiation therapy and capecitabine/oxaliplatin (XELOX) followed by radical resection. Clinical response was assesed by EUS. Rates of pathological tumor regression grade (TRG) and lymph node (LN) involvement were determined in the surgical specimen. Clinical and pathological responses were compared, and the accuracy of EUS in assessing response was calculated. Results: Twenty-four patients (45%) achieved a major pathological response (complete or >95% pathological response (TRG 3+/4)). Sensitivity, specificity, negative predictive value, and positive predictive value of EUS in predicting pathological T response after preoperative CHRT were 77.8%, 37.5%, 60%, and 58%, respectively. The EUS sensitivity, specificity, negative predictive value, and positive predictive value for nodal staging were 44%, 88%, 88%, and 44%, respectively. Furthermore, EUS after CHRT accurately predicted the absence of LN involvement in 7 of 7 patients (100%) with major pathological response of the primary tumor. Conclusion: Preoperative IMRT with concomitant XELOX induces favorable rates of major pathological response. EUS has a limited ability to predict primary tumor response after preoperative CHRT, but it is useful for accurately determining LN status. EUS may have a potential value in identifying patients with a very low risk of LN involvement in association with a good pathological response as potential candidates for conservative local surgical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM Polymorphisms Predict Severe Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: The ataxia telangiectasia mutated (ATM) gene mediates detection and repair of DNA damage. We investigated associations between ATM polymorphisms and severe radiation-induced pneumonitis (RP). Methods and Materials: We genotyped 3 potentially functional single nucleotide polymorphisms (SNPs) of ATM (rs1801516 [D1853N/5557G>A], rs189037 [-111G>A] and rs228590) in 362 patients with non-small cell lung cancer (NSCLC), who received definitive (chemo)radiation therapy. The cumulative severe RP probabilities by genotypes were evaluated using the Kaplan-Meier analysis. The associations between severe RP risk and genotypes were assessed by both logistic regression analysis and Cox proportional hazard model with time to event considered. Results: Of 362 patients (72.4% of non-Hispanic whites), 56 (15.5%) experienced grade ≥3 RP. Patients carrying ATM rs189037 AG/GG or rs228590 TT/CT genotypes or rs189037G/rs228590T/rs1801516G (G-T-G) haplotype had a lower risk of severe RP (rs189037: GG/AG vs AA, adjusted hazard ratio [HR] = 0.49, 95% confidence interval [CI], 0.29-0.83, P=.009; rs228590: TT/CT vs CC, HR=0.57, 95% CI, 0.33-0.97, P=.036; haplotype: G-T-G vs A-C-G, HR=0.52, 95% CI, 0.35-0.79, P=.002). Such positive findings remained in non-Hispanic whites. Conclusions: ATM polymorphisms may serve as biomarkers for susceptibility to severe RP in non-Hispanic whites. Large prospective studies are required to confirm our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Texture and Silica Content on Crack Growth in Boron Nitrides

Boron nitride is used in applications such as crucibles for melting and casting glasses and metals, insulators for furnaces, molds for hot pressing, and neutron absorbers. Historically, various grades of hot pressed hexagonal boron nitride (BN) have been used. This study investigates the fracture toughness and slow crack growth parameters of several commercially available BN grades. Prior work revealed that some grades of BN absorb water and change strength, thus presenting a philosophical conundrum on crack growth test methods. The grades selected for this study are of interest because their available billet size is sufficient for large components, or because they have heritage in specific applications. Ultimately, the data will be used to perform material selection, system design and reliability analyses of components of interest. Boron nitrides exhibit limited slow crack growth in humidity, with an orientation dependence due to crystallographic texture: orientations with van der Waal bonds are insensitive to water whereas those with covalent bonds are sensitive. Fracture toughness is low, around that of glass, and is also a function of orientation (bond type), with fracture occurring more readily along van der Waal bonds between hexagonal BN platelets than at covalent bonds across platelets. Silica additions toughen BN, but increase slow crack growth susceptibility.

Salem, Jonathan A.↗

High-temperature structure, elasticity, and thermal expansion of ε-ZrH 1.8

Zirconium hydride is a promising candidate material for nuclear microreactor applications as a solid-state moderator component, owing to its favorable neutronics properties and good thermal stability over other metal hydrides. Here, in the present work, the crystal structure, thermal expansion, and elastic properties of the hydrogen-rich ε phase hydride were measured at elevated temperatures in the range 300–900 K. Samples were prepared by direct hydriding Zircaloy-4 metal – a nuclear-grade zirconium alloy. Room-temperature lattice parameters agree well with those reported from literature for unalloyed zirconium hydride and fall within an observed quadratic H-content dependence. The coefficients of thermal expansion, determined from lattice expansion and dilatometry, agree well within our work but were about 30 % lower than those reported by others for unalloyed hydrides. Density functional theory-based molecular dynamics simulations were used to compare with thermal expansion and elasticity measurements. Results showed lattice parameter temperature dependence and slope of thermal expansion align with those from measurements. Based on diffraction scans at select temperatures, ε phase remained stable in air up to at least 770 K. Likewise, dilatometry showed smooth thermal expansion up to the thermal decomposition temperature around 950 K. The precise decomposition temperature was not determined via diffraction due to sparse scanning. The complete elastic property measurements were gathered for ε-phase Ziracloy-4 hydride for the first time. Young's modulus was lower compared to the metal and δ hydride phases. High-temperature elasticity measurements were limited to <350 K due to acoustic dissipation effects.

36 MATERIALS SCIENCE↗

C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride

A C-sphere specimen geometry was used to determine the failure strength distributions of a commercially available bearing-grade silicon nitride (Si3N4) having ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably strength-scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diameters indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types in both ball diameters, that one flaw type was always associated with lower strength specimens, and that significantly higher fraction of the 24.5-mm-diameter c-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both c-sphere geometries.

36 MATERIALS SCIENCE↗

Motexafin Gadolinium Combined With Prompt Whole Brain Radiotherapy Prolongs Time to Neurologic Progression in Non-Small-Cell Lung Cancer Patients With Brain Metastases: Results of a Phase III Trial

Purpose: To determine the efficacy of motexafin gadolinium (MGd) in combination with whole brain radiotherapy (WBRT) for the treatment of brain metastases from non-small-cell lung cancer. Methods and Materials: In an international, randomized, Phase III study, patients with brain metastases from non-small-cell lung cancer were randomized to WBRT with or without MGd. The primary endpoint was the interval to neurologic progression, determined by a centralized Events Review Committee who was unaware of the treatment the patients had received. Results: Of 554 patients, 275 were randomized to WBRT and 279 to WBRT+MGd. Treatment with MGd was well tolerated, and 92% of the intended doses were administered. The most common MGd-related Grade 3+ adverse events included liver function abnormalities (5.5%), asthenia (4.0%), and hypertension (4%). MGd improved the interval to neurologic progression compared with WBRT alone (15 vs. 10 months; p = 0.12, hazard ratio [HR] = 0.78) and the interval to neurocognitive progression (p = 0.057, HR = 0.78). The WBRT patients required more salvage brain surgery or radiosurgery than did the WBRT+MGd patients (54 vs. 25 salvage procedures, p < 0.001). A statistically significant interaction between the geographic region and MGd treatment effect (which was in the prespecified analysis plan) and between treatment delay and MGd treatment effect was found. In North American patients, where treatment was more prompt, a statistically significant prolongation of the interval to neurologic progression, from 8.8 months for WBRT to 24.2 months for WBRT+MGd (p = 0.004, HR = 0.53), and the interval to neurocognitive progression (p = 0.06, HR = 0.73) were observed. Conclusion: In the intent-to-treat analysis, MGd exhibited a favorable trend in neurologic outcomes. MGd significantly prolonged the interval to neurologic progression in non-small-cell lung cancer patients with brain metastases receiving prompt WBRT. The toxicity was acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiosensitization of Chemotherapy-Refractory, Locally Advanced or Locally Recurrent Breast Cancer With Trastuzumab: A Phase II Trial

Purpose: Trastuzumab (Herceptin), an anti-human epidermal growth factor receptor 2 (HER2) antibody, has been shown to be an effective radiosensitizer in preclinical studies. The present Phase II trial evaluated trastuzumab plus radiotherapy in patients with HER2-positive, chemotherapy-refractory, locally advanced or locoregionally recurrent breast cancer. Methods and Materials: Eligible patients had measurable disease, normal cardiac function, and biopsy-confirmed residual HER2-positive disease. Patients received weekly trastuzumab (2 mg/kg intravenously), concurrent with radiotherapy (50 Gy) to the breast and regional lymph nodes for 5 weeks. If feasible, surgery followed radiotherapy. The primary endpoint was safety, and the secondary endpoint was efficacy (pathologic response and interval to symptomatic local progression). Results: Of the 19 patients enrolled, 7 were ineligible and received radiotherapy alone and 12 received therapy per protocol. Of these 12 patients, 11 had a Stage T4 diagnosis. Grade 3 toxicities included skin (n = 2) and lymphopenia (n = 1). One patient experienced delayed wound healing after surgery. No patients developed symptomatic cardiac dysfunction. Of the 7 patients who had undergone mastectomy, 3 (43%) had a substantial pathologic response (complete response or microscopic residual disease), significantly more than a comparison cohort (2 of 38 or 5%, p = .02). The median interval to symptomatic local progression was not reached. The median overall survival was 39 months. Conclusion: This is the first prospective trial providing evidence for a radiosensitizing effect of trastuzumab in breast cancer. The combination of trastuzumab and radiotherapy was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalation Study of Single-Fraction Stereotactic Body Radiotherapy for Liver Malignancies

Purpose: We performed a Phase I dose-escalation study to explore the feasibility and safety of treating primary and metastatic liver tumors with single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Between February 2004 and February 2008, 26 patients were treated for 40 identifiable lesions. Nineteen patients had hepatic metastases, 5 had intrahepatic cholangiocarcinomas, and 2 had recurrent hepatocellular carcinomas. The prescribed radiation dose was escalated from 18 to 30 Gy at 4-Gy increments with a planned maximum dose of 30 Gy. Cumulative incidence functions accounted for competing risks to estimate local failure (LF) incidence over time under the competing risk of death. Results: All patients tolerated the single-fraction SBRT well without developing a dose-limiting toxicity. Nine acute Grade 1 toxicities, one acute Grade 2 toxicity, and two late Grade 2 gastrointestinal toxicities were observed. After a median of 17 months follow-up (range, 2-55 months), the cumulative risk of LF at 12 months was 23%. Fifteen patients have died: 11 treated for liver metastases and 4 with primary liver tumors died. The median survival was 28.6 months, and the 2-year actuarial overall survival was 50.4%. Conclusions: It is feasible and safe to deliver single-fraction, high-dose SBRT to primary or metastatic liver malignancies measuring {<=}5 cm. Moreover, single-fraction SBRT for liver lesions demonstrated promising local tumor control with minimal acute and long-term toxicity. Single-fraction SBRT appears to be a viable nonsurgical option, but further studies are warranted to evaluate both control rates and impact on quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the drift-time method to measure the electron lifetime in long-drift-length CdZnTe detectors

The traditional method for electron lifetime measurements of CdZnTe (CZT) detectors relies on using the Hecht equation. The procedure involves measuring the dependence of the detector response on the applied bias to evaluate the μτ product, which in turn can be converted into the carrier lifetime. Despite general acceptance of this technique, which is very convenient for comparative testing of different CZT materials, the assumption of a constant electric field inside a detector is unjustified. In the Hecht equation, this assumption means that the drift time would be a linear function of the distance. This condition is not fulfilled in practice at low applied biases, where the Hecht equation is most sensitive to the μτ product. As a result, researchers usually take measurements at relatively high biases, which work well in the case of the low μτ-product material, <10 -3 cm 2 /V, but give significantly underestimated values for the case of high μτ-product crystals. In this paper, we applied the drift-time method to measure the electron lifetimes in long-drift-length (4 cm) standard-grade CZT detectors produced by the Redlen Technologies. We found that the electron μτ product of tested crystals is in the range 0.1–0.2 cm 2 /V, which is an order of the magnitude higher than any value previously reported for a CZT material. Finally, in comparison, using the Hecht equation fitting, we obtained μτ = 2.3 × 10 -2 cm 2 /V for a 2-mm thin planar detector fabricated from the same CZT material.

47 OTHER INSTRUMENTATION↗

Modeling Plan-Related Clinical Complications Using Machine Learning Tools in a Multiplan IMRT Framework

Purpose: To predict organ-at-risk (OAR) complications as a function of dose-volume (DV) constraint settings without explicit plan computation in a multiplan intensity-modulated radiotherapy (IMRT) framework. Methods and Materials: Several plans were generated by varying the DV constraints (input features) on the OARs (multiplan framework), and the DV levels achieved by the OARs in the plans (plan properties) were modeled as a function of the imposed DV constraint settings. OAR complications were then predicted for each of the plans by using the imposed DV constraints alone (features) or in combination with modeled DV levels (plan properties) as input to machine learning (ML) algorithms. These ML approaches were used to model two OAR complications after head-and-neck and prostate IMRT: xerostomia, and Grade 2 rectal bleeding. Two-fold cross-validation was used for model verification and mean errors are reported. Results: Errors for modeling the achieved DV values as a function of constraint settings were 0-6%. In the head-and-neck case, the mean absolute prediction error of the saliva flow rate normalized to the pretreatment saliva flow rate was 0.42% with a 95% confidence interval of (0.41-0.43%). In the prostate case, an average prediction accuracy of 97.04% with a 95% confidence interval of (96.67-97.41%) was achieved for Grade 2 rectal bleeding complications. Conclusions: ML can be used for predicting OAR complications during treatment planning allowing for alternative DV constraint settings to be assessed within the planning framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Pneumonitis Risk: A Dosimetric Alternative to Mean Lung Dose

Purpose: To determine whether the association between mean lung dose (MLD) and risk of severe (grade {>=}3) radiation pneumonitis (RP) depends on the dose distribution pattern to normal lung among patients receiving 3-dimensional conformal radiation therapy for non-small-cell lung cancer. Methods and Materials: Three cohorts treated with different beam arrangements were identified. One cohort (2-field boost [2FB]) received 2 parallel-opposed (anteroposterior-posteroanterior) fields per fraction initially, followed by a sequential boost delivered using 2 oblique beams. The other 2 cohorts received 3 or 4 straight fields (3FS and 4FS, respectively), ie, all fields were irradiated every day. The incidence of severe RP was plotted against MLD in each cohort, and data were analyzed using the Lyman-Kutcher-Burman (LKB) model. Results: The incidence of grade {>=}3 RP rose more steeply as a function of MLD in the 2FB cohort (N=120) than in the 4FS cohort (N=138), with an intermediate slope for the 3FS group (N=99). The estimated volume parameter from the LKB model was n=0.41 (95% confidence interval, 0.15-1.0) and led to a significant improvement in fit (P=.05) compared to a fit with volume parameter fixed at n=1 (the MLD model). Unlike the MLD model, the LKB model with n=0.41 provided a consistent description of the risk of severe RP in all three cohorts (2FB, 3FS, 4FS) simultaneously. Conclusions: When predicting risk of grade {>=}3 RP, the mean lung dose does not adequately take into account the effects of high doses. Instead, the effective dose, computed from the LKB model using volume parameter n=0.41, may provide a better dosimetric parameter for predicting RP risk. If confirmed, these findings support the conclusion that for the same MLD, high doses to small lung volumes ('a lot to a little') are worse than low doses to large volumes ('a little to a lot').

62 RADIOLOGY AND NUCLEAR MEDICINE↗