An investigation of the optimization of parameters affecting the implementation of fourier transform spectroscopy at 20-500 micron from the C-141 airborne infrared observatory

A program for 20-500 micron spectroscopy from the NASA flying C141 infrared observatory is being carried out with a Michelson interferometer. The parameters affecting the performance of the instrument are studied and an optimal configuration for high performance on the C-141 aircraft is recommended. As each parameter is discussed the relative merits of the two modes of mirror motion (rapid scan or step and integrate) are presented.

Thompson, R. I.↗

Improved fourier interference spectrometer

Proposed system compensates for velocity changes by multiplying detector output by signal proportional to scan velocity. Increases in velocity are compensated by increase signal from velocity circuit and decreases in velocity are offset by smaller signal from circuit thereby making output signal velocity independent.

Schindler, R. A.↗

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.↗

Fourier and Hadamard transform spectrometers - A limited comparison. II

A mathematical approach was used to compare interferometric spectrometers and Hadamard transform spectrometers. The principle results are reported, noting that the simple Hadamard spectrometer encodes more efficiently than a Michelson interferometer which, in turn, encodes less efficiently than is usually acknowledged. Hirschfeld's (1977) major objections to these findings are discussed, although it is noted that none of his objections is supported by evidence.

Harwit, M.↗

Airborne infrared astronomical observations by Fourier transform spectroscopy

Infrared spectroscopic observations from NASA-operated aircraft constitute a rapidly maturing application of FTS methods initially developed for ground-based telescopes. Coupled to airborne telescopes up to 36 in. in diameter, these experiments are now producing new astronomical results as exciting and unexpected as those derived from Connes's first high resolution planetary observations at mountain-top observatories. This review examines the special problems of the IR spectral region that led to aircraft observatories and includes a brief survey of the facilities themselves and their modes of operation. The special problems of operating FTS devices on aircraft and the scientific results achieved with current capabilities are discussed. Finally, airborne observations are compared to the ultimate in high-altitude observing platforms: earth-orbiting cooled and uncooled telescopes carried by the Space Shuttle vehicle.

Larson, H. P.↗

The determination of gravity anomalies from geoid heights using the inverse Stokes' formula, Fourier transforms, and least squares collocation

A numerical method for the determination of gravity anomalies from geoid heights is described using the inverse Stokes formula. This discrete form of the inverse Stokes formula applies a numerical integration over the azimuth and an integration over a cubic interpolatory spline function which approximates the step function obtained from the numerical integration. The main disadvantage of the procedure is the lack of a reliable error measure. The method was applied on geoid heights derived from GEOS-3 altimeter measurements in the calibration area of the GEOS-3 satellite.

Rummel, R.↗

Faster fourier transformation: The algorithm of S. Winograd

The new DFT algorithm of S. Winograd is developed and presented in detail. This is an algorithm which uses about 1/5 of the number of multiplications used by the Cooley-Tukey algorithm and is applicable to any order which is a product of relatively prime factors from the following list: 2,3,4,5,7,8,9,16. The algorithm is presented in terms of a series of tableaus which are convenient, compact, graphical representations of the sequence of arithmetic operations in the corresponding parts of the algorithm. Using these in conjunction with included Tables makes it relatively easy to apply the algorithm and evaluate its performance.

Zohar, S.↗

Delay compensation - Its effect in reducing sampling errors in Fourier spectroscopy

An approximate formula is derived for the spectrum ghosts caused by periodic drive speed variations in a Michelson interferometer. The solution represents the case of fringe-controlled sampling and is applicable when the reference fringes are delayed to compensate for the delay introduced by the electrical filter in the signal channel. Numerical results are worked out for several common low-pass filters. It is shown that the maximum relative ghost amplitude over the range of frequencies corresponding to the lower half of the filter band is typically 20 times smaller than the relative zero-to-peak velocity error, when delayed sampling is used. In the lowest quarter of the filter band it is more than 100 times smaller than the relative velocity error. These values are ten and forty times smaller, respectively, than they would be without delay compensation if the filter is a 6-pole Butterworth.

Zachor, A. S.↗

Fourier emission infrared microspectrophotometer for surface analysis. I - Application to lubrication problems

A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.

Lauer, J. L.↗

Fourier spectroscopy of the stratospheric emission

Stratospheric emission spectra in the submillimeter range have been recorded with a resolution of 0.0033/cm with a balloon-borne interferometer. Several minor atmospheric constituents have been identified in a preliminary analysis of the spectra; these are water vapor, oxygen, ozone isotopes, nitric acid, nitrous oxide, hydrofluoric and hydrochloric acids, and carbon monoxide.

Carli, B.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Optical alignment of high resolution Fourier transform spectrometers

Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

Breckinridge, J. B.↗

Modal analysis using a Fourier analyzer, curve-fitting, and modal tuning

The proposed modal test program differs from single-input methods in that preliminary data may be acquired using multiple inputs, and modal tuning procedures may be employed to define closely spaced frquency modes more accurately or to make use of frequency response functions (FRF's) which are based on several input locations. In some respects the proposed modal test proram resembles earlier sine-sweep and sine-dwell testing in that broadband FRF's are acquired using several input locations, and tuning is employed to refine the modal parameter estimates. The major tasks performed in the proposed modal test program are outlined. Data acquisition and FFT processing, curve fitting, and modal tuning phases are described and examples are given to illustrate and evaluate them.

Craig, R. R., Jr.↗

A calibration line list for 807-1167 cm -1 from high resolution Fourier spectroscopy of the 14NH3 nu sub 2 band

A calibration list of 295 lines observed over the 800 to 1170 cm to the -1 power region is presented. This list is intended for use as a calibration reference for calibrating diode laser spectra. The transition frequencies were calibrated against the well established laser frequencies of CO2. The estimated uncertainty in the corrected frequencies is + or - 1x.0001 cm to the -1 power.

Hillman, J. J.↗