PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

Tonal Noise Control Using Rotor Phase Synchronization

The purpose of this study is to determine if phase synchronization can be used to reduce the net radiated sound power from two rotors. Phase synchronization implies that the rotors have the same rotational speed with a fixed relative azimuthal blade position, or phase. The concept is evaluated both experimentally and numerically. Measurements of source directivity and thrust are initially compared with predictions to confirm that the model accurately captures the relevant trends. The model is then used to explore the design space and identify relevant parameters. Both experimental and numerical results show that the radiated sound power at the blade passage frequency can be reduced by appropriately controlling the relative azimuthal phase of the rotors. Vehicle level predictions are also provided for a notional octocopter, comparing two different modes of operation. Predictions show that phase synchronization can be used to achieve a 4-5 dB reduction of the sound pressure level at the blade passage frequency nearly everywhere on the ground plane beneath the vehicle.

Noah H Schiller↗

Hard ACTS to follow

The Advanced Communications Technology Satellite (ACTS), the third phase of NASA's 30/20 GHz satellite communications program, is praised for its frugal usage of both the geosynchronous orbital arch and the frequency spectrum resources necessary for communications satellites. Its objective is to verify Ka-band satellite communications concepts and to develop a flight and ground system for validation of the multibeam communications proof-of-concept technologies. The ACTS ground segment (comprised of four types of terminals) is designed to compliment the spacecraft for the SS launch in 1989. Precise coordination between the ground and spacecraft segments is performed by the baseband processor (BBP), which is an in-orbit switchboard, and the tracking error word, which enables the ground terminals to remain synchronized with onboard timing. Fixed spot beams and scan beams, comprising the two types of spot beams used, both operate at the same frequency and hence, conserve frequency resources. In addition, the time division multiple access serves to enhance system efficiency. It is concluded that Ka-band satellites are a practical approach to the better usage of those resources potentially threatened by communications satellites. Comprehensive graphs and block diagrams of the system are included.

Moy, L.↗

Harmonic structure of Pc 3-4 pulsations

Power spectra of magnetic pulsations observed at synchronous orbit by the ATS 6 satellite often show several spectral peaks simultaneously. Such pulsations, called harmonic events because of the nearly constant separation between successive peaks, are continuously observed in the dayside in the Pc 3-4 frequency range (6.6-100 mHz). The harmonic events are seen clearly only in the east-west magnetic field component. The spectral peaks are regularly spaced with a typical minimum separation of 14 mHz in the morning gradually decreasing to 10 mHz in the afternoon. In the dynamic spectra of harmonic events, the fundamental mode is usually absent. In addition, the relative amplitudes of the higher harmonics depend on the magnetic latitude. These observed features can be explained by a standing Alfven wave consisting of many discrete harmonic frequencies. A statistical analysis of power spectra demonstrates that at least 10-30% of Pc 3 pulsations can be classified as harmonic events. For a selected event on August 7, 1975, the plasma mass density at the synchronous orbit is estimated to be 3-8 hydrogen mass/cu cm.

Takahashi, K.↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs: Preprint

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.

frequency-shaping control↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Decentralized Data-Driven Estimation of Generator Rotor Speed and Inertia Constant Based on Adaptive Unscented Kalman Filter

This paper proposes an online decentralized and data-driven method for synchronous generator rotor speed and inertia estimation. First, an analytical relationship between the generator terminal voltage/current phasors and its internal rotor speed is derived using the Thevenin equivalent. The parameters of the latter are obtained via a recursive estimator, which allows us to estimate the generator's internal rotor speed from voltage/current phasors without the need for any generator information. Second, we reformulate the equivalent swing equation into the Kalman filter form, which enables us to use a priori-estimated internal rotor speed along with measured real and reactive power injections to obtain an estimate of the inertia for each online synchronous generator. This is achieved through an adaptive unscented Kalman filter. We demonstrate that the use of terminal bus frequency to approximate the rotor speed for inertia estimation by existing methods leads to large estimation biases/errors. Numerical simulations carried out on the IEEE 39-bus and Texas 2000-bus systems reveal that our proposed method is consistently more accurate than existing methods. Moreover, our proposed method is insensitive to both the type and location of system disturbances, and it is robust to different levels of measurement noise.

bus frequency↗

Laser space rendezvous and docking system study continuation

Investigations were made of a configuration for a spaceborne laser radar (ladar) to meet the requirements for rendezvous and docking with a cooperative object in synchronous orbit. An analysis was completed of laser phase locking techniques, while experimental verification was made of pulse repetition frequency and resonant scanning control loops. Data measurements on a satellite mock-up were also made. The investigation supports the original contention that a rendezvous and docking ladar can be configured to offer a cost effective and reliable solution to envisioned space missions.

Adelman, S.↗

New features of different frequency generating systems due to the use of electrodeless rigidly mounted VBA quartz crystal resonator

The BVA 5 MHz crystal equipped frequency sources exhibit a new blend of performances such as 10 to 11 daily stability, 5x10-13 short term stability (1 to 30 s time intervals) and close to the carrier low phase noise (1 Hz : -120 dBc, 10 Hz : -140 dBc), whereby retaining the customary crystal oscillator benefits of small volume, high reliability and low price, as opposed to more sophisticated frequency generators which would be required to achieve comparable performances. Examples illustrating the impact of the Oscilloquartz BVA oven-controlled crystal oscillator in different frequency generating systems are presented: cesium frequency standards; hydrogen frequency standard; a precision distribution sub-system for satellite ground stations; and high hierarchy exchanges of digital networks, synchronized by the master-slave method are discussed.

Jendly, A.↗

Field Telemetry of Blade-rotor Coupled Torsional Vibration at Matuura Power Station Number 1 Unit

The quasi-modal reduction technique and finite element model (FEM) were used to construct an analytical model for the blade-rotor coupled torsional vibration of a steam turbine generator of the Matuura Power Station. A single rotor test was executed in order to evaluate umbrella vibration characteristics. Based on the single rotor test results and the quasi-modal procedure, the total rotor system was analyzed to predict coupled torsional frequencies. Finally, field measurement of the vibration of the last stage buckets was made, which confirmed that the double synchronous resonance was 124.2 Hz, meaning that the machine can be safely operated. The measured eigen values are very close to the predicted value. The single rotor test and this analytical procedure thus proved to be a valid technique to estimate coupled torsional vibration.

Isii, Kuniyoshi↗

Experiment K-7-28: Lung Morphology Study

There are no previous studies investigating the effect of microgravity exposure during spaceflight on lung tissue. We examined the ultrastructure of the left lungs of 5 Czechoslovakian Wistar rats flown on the 13 day, 19+ hr. Cosmos 2044 mission, and compared them to 5 vivarium and 5 synchronous controls at 1-g conditions, and 5 rats exposed to 14 days of tail-suspension. Within 10 minutes of sacrifice by decapitation, the lungs were removed and immersed in 3% glutaraldehyde in 0.1M phosphate buffer (total osmolarity of the fixative: 560 mOsm; pH = 7.4). The tissue stored at 5 C was transported to our laboratory where it was processed for light and electron microscopy. No significant perivascular cuffing caused by interstitial edema was present in the tissue samples. Some of the flight, tail-suspended, and synchronous control rats showed alveolar edema, while vivarium controls did not. The pulmonary capillaries appeared to be more congested in the flight animals than in the other groups. This could be related to the increased hematocrit due to the microgravity exposure. In all 5 flight, 4 tail-suspended, and 3 synchronous rats, red blood cells (RBC) were present in the alveolar spaces. The RBC were either suspended free in the alveoli or observed lining the alveolar wall. The frequency of RBC lining the alveolar walls appeared greater in the dorsal (gravity non-dependent) than in ventral (gravity dependent) regions of the lung in these three animal groups. In 3 of the vivarium controls, a few RBC were found in the alveolar spaces. Intra-capillary fluid-filled vesicles were observed in the flight, tail-suspended and synchronous animals, but not in the vivarium controls. The formation of intra-capillary fluid-filled vesicles has been previously associated with pulmonary hypertension induced by high altitude exposure and mitral stenosis. In conclusion, pulmonary hemorrhage and alveolar edema of unknown origin occurred to a greater extent in the flight, tail-suspended, and synchronous control animals, and in the dorsal regions of the lung when compared to the vivarium controls. The etiology of these changes, which are possibly due to an increase in pulmonary vascular pressure, requires further investigation.

West, J. B.↗

Quantum nonlocal modulation cancelation with distributed clocks

We demonstrate nonlocal modulation of entangled photons with truly distributed radio frequency (RF) clocks. Leveraging a custom radio-over-fiber (RFoF) system characterized via classical spectral interference, we validate its effectiveness for quantum networking by multiplexing the RFoF clock with one photon from a frequency-bin-entangled pair and distributing the coexisting quantum-classical signals over fiber. Phase modulation of the two photons reveals nonlocal correlations in excellent agreement with theory: in-phase modulation produces additional sidebands in the joint spectral intensity, while out-of-phase modulation is nonlocally canceled. Our simple, feedback-free design attains subpicosecond synchronization—namely, drift less than ~0.5 ps in a 5.5 km fiber over 30 min (fractionally only ~2×10 -8 of the total fiber delay)—and should facilitate frequency-encoded quantum networking protocols such as high-dimensional quantum key distribution and entanglement swapping, unlocking frequency-bin qubits for practical quantum communications in deployed metropolitan-scale networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Power system inertia estimation: Review of methods and the impacts of converter-interfaced generations

Understanding and quantifying the inertia of power systems with the integration of converter-interfaced generation (CIG) plays an essential role in the safe transition to a future low-inertia scenario. Here we provide a comprehensive summary of inertia definitions for both synchronous generators and CIGs as well as their corresponding estimation methods. In particular, the estimation methods are categorized as model-based and measurement-based approaches considering both small and large disturbances. The advantages and disadvantages of different methods are carefully discussed. This paper also offers for the first time a framework to quantify the virtual inertia of CIGs at the component and aggregation levels, an open problem in the literature. Finally, future directions for inertia estimation are identified and discussed. This significantly benefits the design of appropriate control and protection schemes in achieving a more reliable, secure, and resilient power system.

42 ENGINEERING↗

The connection between Venus' free obliquity and its CMB oblateness

The most striking feature of Venus rotational state is its slow retrograde rotation which is apparently maintained by a balance between solid tidal friction and thermal tidal torques. Solid tides tend to drive the spin toward synchronous rotation while thermal tides drive it away. A balance is achieved at a specific rate because of the inverse frequency dependence of the thermal tide to the semi-diurnal heating. Atmospheric models have been constructed to estimate the thermal tidal torque based on ground heating. The solid friction dissipation factor Q approximately equal to 50 can be deduced assuming rotation has achieved steady state. The most perplexing feature of Venus orientation is its non-zero free obliquity epsilon approximately equal to 1.5 deg relative to its orbit. Although solid tides and perhaps atmospheric tides tend to increase the free obliquity on a time 1/K(sub t) approximately equal to 1 x 10(exp 8) yr, viscous friction (CMF) at a core-mantle boundary (CMB) resulting from the differential angular orientation Delta-epsilon of the core and mantle spin axes should have damped the free obliquity on a time scale as short as 10(exp 6) yr. One means of achieving a balance similar to that controlling rotation is to introduce a comparatively large CMB ellipticity e(sub c) to reduce Delta-epsilon such that there is a balance between solid-thermal tides and CMF. The balance depends not so much on the potential frequency dependence on the tides as on the quadratic dependence of CMF on Delta-epsilon if the layer is turbulent.

Yoder, C. F.↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Securing and Auto-Synchronizing Communication over Free-Space Optics Using Quantum Key Distribution and Chaotic Systems

Free-Space Optical (FSO) communication provides very large bandwidth, relatively low cost, low power, low mass of implementation, and improved security when compared to conventional Free-Space Radio-Frequency (FSRF) systems. In this paper, we demonstrate a communication protocol that demonstrates improved security and longer-range FSO communication, compared to existing FSO security techniques, such as N-slit interferometers. The protocol integrates chaotic communications with Quantum Key Distribution (QKD) techniques. A Lorenz chaotic system, which is inherently secure and auto-synchronized, is utilized for secure data communications over a classical channel, while QKD is used to exchange crucial chaotic system parameters over a secure quantum channel. We also provide a concept of operations for a NASA mission combining chaotic communications and QKD operating synergistically in an end-to-end space communications link. The experimental simulation results and analysis are favorable towards our approach.

Chaotic Communication↗