Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEEDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Erythroneura lawsoni abundance and feeding injury levels are influenced by foliar nutrient status in intensively managed American sycamore.

Abstract 1 Abundance and feeding injury of the leafhopper Erythroneura lawsoni Robinson was measured in an intensively-managed American sycamore Platanus occidentalis L. plantation. Trees were planted in spring 2000 in a randomized complete block design, and received one of three annual treatments: (i) fertilization (120 kg N/ha/year); (ii) irrigation (3.0 cm/week); (iii) fertilization + irrigation; or (iv) control (no treatment). 2 Foliar nutrient concentrations were significantly influenced by the treatments because only sulphur and manganese levels were not statistically greater in trees receiving fertilization. 3 Over 116 000 E. lawsoni were captured on sticky traps during the study. Leafhopper abundance was highest on nonfertilized trees for the majority of the season, and was positively correlated with foliar nutrient concentrations. Significant temporal variation in E. lawsoni abundance occurred, suggesting five discrete generations in South Carolina. 4 Significant temporal variation occurred in E. lawsoni foliar injury levels, with the highest injury ratings occurring in late June and August. Foliar injury was negatively correlated with foliar nutrient content, and higher levels of injury occurred more frequently on nonfertilized trees. 5 The results obtained in the present study indicated that increased E. lawsoni abundance occurred on trees that did not receive fertilization. Nonfertilized trees experienced greater foliar injury, suggesting that lower foliar nutrient status may have led to increased levels of compensatory feeding.

60 APPLIED LIFE SCIENCES↗

Supervisory Feed-Forward Control for Real-Time Topping Cycle CHP Operation

This paper presents an energy dispatch algorithm for real-time topping cycle Cooling, Heating, and Power (CHP) operation for buildings with the objective of minimizing the operational cost, primary energy consumption (PEC), or carbon dioxide emission (CDE). The algorithm features a supervisory feed-forward control for real-time CHP operation using short-term weather forecasting. The advantages of the proposed control scheme for CHP operation are (a) relatively simple and efficient implementation allowing realistic real-time operation , (b) optimized CHP operation with respect to operational cost, PEC, or CDE, and (c) increased site-energy consumption (SEC) resulting in less dependence on the electric grid. In the feed-forward portion of the control scheme, short-term electric, cooling, and heating loads are predicted using the U.S. Department of Energy (DOE) benchmark small office building model. The results are encouraging regarding the potential saving of operational cost, PEC, and CDE from using the control system for a CHP system with electric and thermal energy storages.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing Load Cell Monitoring on the Mock UF 6 Feed and Withdrawal System

A proof-of-concept load cell monitoring system has been developed for the Mock Feed and Withdrawal (F&W) System at Oak Ridge National Laboratory (ORNL). This system leverages industry-standard commercial off-the-shelf (COTS) hardware and software in a modular and scalable design. The Mock F&W System was designed to simulate operations at a uranium hexafluoride (UF 6 ) gas centrifuge enrichment plant F&W area. It provides a test bed for process-monitoring technologies. Water, used as a surrogate for UF 6 , is pumped from three feed tanks, through a process surge tank, and is then cut between two tails tanks and three product tanks. The weight of the each tank is continuously monitored using a load cell monitoring system. In addition to the F&W stations, large and small accountancy stations are monitored. The Mock F&W System allows ORNL to test and evaluate capabilities of industry-standard process monitoring hardware and software. A variety of commonly used weighing indicators are connected to the load cells to monitor the weight at each station. These weighing indicators are representative of the types likely found in operating facilities. A data center modeled after those currently used for international safeguards was installed to collect and manage the weight data. This data center provides a robust and flexible test bed for testing and developing software solutions. COTS software packages that leverage industry-standard communication protocols provide a data flow architecture that is modular, interoperable, and scalable. One software package provides communication drivers to collect the raw weight data from the weighing indicators. A data historian is used to store the raw data. Custom in-house algorithms have been developed using MATLAB to analyze the raw historical data and to automatically identify process information. This information includes the number of cycles completed and the mass of material transferred from stations to the process. The process information identified by the analysis is stored in a Microsoft SQL Server database. Visualization concepts have been developed that display the analyzed process information alongside visually compelling plots and animations of the raw data. The load cell monitoring system developed on the Mock F&W System was designed as a proof of concept that could be scaled to a field trial at an operating facility. This system, built with industry standard hardware and software, has allowed ORNL to develop capabilities that provide confidence in the ability to leverage existing operator load cell monitoring equipment with minimal impact on operations. The international safeguards community is evaluating the use of load cell monitoring as an additional safeguards measure; this system demonstrates a practical solution to collect, store, analyze, and visualize load cell weight data.

commercial off the shelf↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant

A comprehensive front-end engineering design (FEED) study has been undertaken for a post-combustion capture (PCC) unit located at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in a full and unredacted FEED study report with all supporting documents, numbering over 150, also publicly available.

20 FOSSIL-FUELED POWER PLANTS↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

Development of Enabling Technologies for a Pressurized Dry Feed Oxy-Coal Reactor

Researchers at Brigham Young University (3 faculty, 9 graduate students, and 35 undergraduate students) completed this 5-year research program with the main objective to build and test a 100 kWth pressurized dry-feed oxy-coal combustor (POC). This objective was achieved through the development and testing of a unique pressurized dry coal fluidization feed system that operates in conjunction with a pressurized oxycoal combustor. The project included a series of R&D tasks, including design, modeling, bench-scale testing, construction, safety reviews, and reactor testing which are detailed in this report. BYU researchers were supported in some modeling tasks by project partners Reaction Engineering International (REI) and CPFD Software.

01 COAL, LIGNITE, AND PEAT↗

Feed-in Tariff Policy: Design, Implementation, and RPS Policy Interactions

Feed-in tariff (FIT) policies are implemented in more than 40 countries around the world and are cited as the primary reason for the success of the German and Spanish renewable energy markets. As a result of that success, FIT policy proposals are starting to gain traction in several U.S. states and municipalities. Experience from Europe is also beginning to demonstrate that properly designed FITs may be more cost-effective than renewable portfolio standards (RPS), which make use of competitive solicitations. This article explores the design and operation of feed-in tariff policies, including a FIT policy definition, payment-structure options, and payment differentiation. The article also touches on the potential interactions between FIT policies and RPS policies at the state level.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Mock UF6 Feed and Withdrawal System for Testing Safeguards Monitoring Systems and Strategies Intended for Nuclear Fuel Enrichment and Processing Plants

This report describes an engineering-scale, mock UF6 feed and withdrawal (F&W) system, its operation, and its intended uses. This system has been assembled to provide a test bed for evaluating and demonstrating new methodologies that can be used in remote, unattended, continuous monitoring of nuclear material process operations. These measures are being investigated to provide independent inspectors improved assurance that operations are being conducted within declared parameters, and to increase the overall effectiveness of safeguarding nuclear material. Testing applicable technologies on a mock F&W system, which uses water as a surrogate for UF6, enables thorough and cost-effective investigation of hardware, software, and operational strategies before their direct installation in an industrial nuclear material processing environment. Electronic scales used for continuous load-cell monitoring also are described as part of the basic mock F&W system description. Continuous monitoring components on the mock F&W system are linked to a data aggregation computer by a local network, which also is depicted. Data collection and storage systems are described only briefly in this report. The mock UF{sub 6} F&W system is economical to operate. It uses a simple process involving only a surge tank between feed tanks and product and withdrawal (or waste) tanks. The system uses water as the transfer fluid, thereby avoiding the use of hazardous UF{sub 6}. The system is not tethered to an operating industrial process involving nuclear materials, thereby allowing scenarios (e.g., material diversion) that cannot be conducted otherwise. These features facilitate conducting experiments that yield meaningful results with a minimum of expenditure and quick turnaround time. Technologies demonstrated on the engineering-scale system lead to field trials (described briefly in this report) for determining implementation issues and performance of the monitoring technologies under plant operating conditions. The ultimate use of technologies tested on the engineering-scale test bed is to work with safeguards agencies to install them in operating plants (e.g., enrichment and fuel processing plants), thereby promoting new safeguards measures with minimal impact to operating plants. In addition, this system is useful in identifying features for new plants that can be incorporated as part of 'safeguards by design,' in which load cells and other monitoring technologies are specified to provide outputs for automated monitoring and inspector evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Testing LIDAR Based Feed-Forward Controls on the NREL Controls Advanced Research Turbine: Preprint

Wind turbines are complex, nonlinear, dynamic systems driven by aerodynamic, gravitational, centrifugal, and gyroscopic forces. The aerodynamics of wind turbines are nonlinear, unsteady, and complex. Turbine rotors are subjected to a chaotic three-dimensional (3-D) turbulent wind inflow field with imbedded coherent vortices that drive fatigue loads and reduce lifetime. In order to reduce cost of energy, future large multimegawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, maximize energy capture, and add active damping to maintain stability for these dynamically active structures operating in a complex environment. Researchers at the National Renewable Energy Laboratory (NREL) and University of Stuttgart are designing, implementing, and testing advanced feed-back and feed-forward controls in order to reduce the cost of energy for wind turbines.

17 WIND ENERGY↗

Distributed Parameter Analysis of Pressure and Flow Disturbances in Rocket Propellant Feed Systems

A digital distributed parameter model for computing the dynamic response of propellant feed systems is formulated. The analytical approach used is an application of the wave-plan method of analyzing unsteady flow. Nonlinear effects are included. The model takes into account locally high compliances at the pump inlet and at the injector dome region. Examples of the calculated transient and steady-state periodic responses of a simple hypothetical propellant feed system to several types of disturbances are presented. Included are flow disturbances originating from longitudinal structural motion, gimbaling, throttling, and combustion-chamber coupling. The analytical method can be employed for analyzing developmental hardware and offers a flexible tool for the calculation of unsteady flow in these systems.

UNSTEADY FLOW↗

1KW Power Transmission Using Wireless Acoustic-Electric Feed-Through (WAEF)

A variety of space applications require the delivery of power into sealed structures. Since the structural integrity can be degraded by holes for cabling we present an alternative method of delivering power and information using stress waves to the internal space of a sealed structure. One particular application of this technology is in sample return missions where it is critical to preserve the sample integrity and to prevent earth contamination. Therefore, the container has to be hermetically sealed and the integrity of the seal must be monitored in order to insure to a high degree of reliability the integrity of the sample return vessel. In this study we investigated the use of piezoelectric acoustic-electric power feed-through devices to transfer electric power wirelessly through a solid wall by using elastic or acoustic waves. The technology is applicable to a range of space and terrestrial applications where power is required by electronic equipment inside sealed containers, vacuum or pressure vessels, etc., where holes in the wall are prohibitive or may result in significant structural performance degradation or unnecessarily complex designs. To meet requirements of higher power applications, the feasibility to transfer kilowatts level power was investigated. Pre-stressed longitudinal piezoelectric feed-through devices were analyzed by finite element models and an equivalent circuit model was developed to predict the power transfer characteristics to different electric loads. Based on the results of the analysis a prototype device was designed, fabricated and a demonstration of the transmission of electric power up to 1.068-kW was successfully conducted. Efficiencies in the 80-90% range were also demonstrated and methods to increase the efficiency further are currently being considered.

pressure vessels↗

The S/X-Band Microwave Feed System for NASA's First Beamwaveguide Antenna

The configuration, detail design, and performance of a dual S/X- band microwave feed system for the first Deep Space Network beamwaveguide antenna is reported. This antenna, which is primarily used for research and development tasks, is an elevation-over-azimuth type using wheel and track azimuth bearings. The S/X-band microwave feed system is super low noise for support of deep space missions.

microwave↗

Hepatic Arterial Embolization Using Cone Beam CT with Tumor Feeding Vessel Detection Software: Impact on Hepatocellular Carcinoma Response

PurposeDedicated tumor feeding vessel detection software (TFVDS) using cone beam CT has shown a higher sensitivity to detect tumor feeding vessels during hepatic arterial embolization (HAE) of hepatocellular carcinoma (HCC) compared to 2D imaging. Our primary hypothesis was that HCC tumors treated with HAE guided by a TFVDS would show more complete response (CR) than when treated with 2D imaging alone. Secondary analysis of the impact on X-ray exposure was performed.Materials and MethodsNineteen males and 8 females (median age: 69 year, 46–85) with 44 tumors (median size: 38 mm, 6–100) treated with selective HAE between January 2013 and December 2014 were included. Exclusion criteria were: extra-hepatic supply, >4 tumors, tumor size >10 cm, and adjunctive local therapy. Baseline patient and procedure characteristics were reviewed. Differences in CR per modified Response Evaluation Criteria in Solid Tumors were assessed by univariate and multivariate analyses for tumor size, number, location, particles size, and use of TFVDS.ResultsMedian imaging follow-up was 20.1 months (2–33). Use of TFVDS (13 patients, 19 tumors) was the only factor predictive of CR (OR = 3.85 [CI95%: 1.09, 13.67], p = 0.04) on univariate analysis but not on multivariate analysis (OR = 3.26 [0.87, 12.23], p = 0.08). A higher rate of CR was observed for HAE using TFVDS guidance versus 2D imaging alone (68.4%, 13–19, vs. 36%, 9–25, p = 0.03). Median dose area product was lower when TFVDS was used (149.7 Gy.cm{sup 2}, 38–365, vs. 227.8 Gy.cm{sup 2}, 85.3–468.6, p = 0.05).ConclusionsHCC embolized with TFVDS may result in improved local tumor response without increasing the dose exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Multicomponent Hydrocarbon Feed on Hydrocarbon Adsorption–Desorption and Oxidation Light-Off Behavior on a Pd/BEA Hydrocarbon Trap

A model hydrocarbon trap material consisting of palladium promoted zeolite beta on a monolith core was studied with a multicomponent hydrocarbon feed. Dodecane and ethylene adsorption, followed by temperature programmed oxidation (TPO), was used in the presence of CO in wet and dry conditions to study the impact of various species on hydrocarbon storage, oxidation, and desorption. Low temperature adsorption experiments were used to quantify hydrocarbon storage capacity, while temperature programmed desorption (TPD) and TPO studies were used to investigate both oxidation and desorption of the various hydrocarbon species. Here, the low temperature adsorption experiments suggest a moderate impact of water on dodecane uptake as dry experiments adsorbed more dodecane overall than those under wet conditions. Additionally, the presence of CO and ethylene also impaired dodecane uptake. TPD studies indicated a coupled relationship between hydrocarbon oxidation light-off and desorption. By varying the composition of the feed, specifically via the inclusion of CO or ethylene, dodecane oxidation light-off was delayed, which actually increased the overall hydrocarbon trap efficiency.

42 ENGINEERING↗