Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new control score concept for building performance assessment

In buildings, performance assessment often focuses on energy use with metrics such as energy use intensity (EUI) used to benchmark performance. However, energy performance of a building is fundamentally determined by the control system that engages the energy-using systems. There are two aspects of control that are of particular importance: (1) the ability to regulate process variables to their setpoints; and (2) whether the setpoints are at the right levels and/or following desired profiles. Most buildings do not reach their energy efficiency potential due to deficiencies in control performance and operators do not have access to metrics that can illuminate these deficiencies. Here this paper addresses this problem by providing novel techniques that combine these two aspects of control performance into a single standardized score on the scale of 0-10. The concept of a standardized control scores enables all systems in a building to be compared on the same scale and also for scores to be rolled up to different levels in the building and system hierarchy for system-wide analysis. The paper presents the theory for the method, describes a prototype tool for displaying scores, and presents results from application to a large building in Minneapolis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

pnnl/CPACE

C-PACE Market Assessment Tool This tool was developed for the U.S. Department of Energy’s Commercial Property Assessed Clean Energy (C-PACE) Working Group to support state and local governments creating, joining, and implementing C-PACE programs. This tool allows users to input a jurisdiction (city, county, or state) and automate a report with building characteristics, energy use, and energy efficiency savings opportunities for commercial buildings in that jurisdiction. The report generated by the tool identifies jurisdiction-specific energy end uses, building use types, and building technologies that a local C-PACE program should consider focusing on to more effectively allocate limited resources and maximize energy savings and investment.

Keene, Kevin↗

Medical Imaging Equipment Energy Efficiency

The energy use of medical imaging equipment (MIE) in healthcare facilities is estimated to be about 5% of total site energy use. MIE energy use is only expected to increase as technology advances and more patients seek services from MIE, enabling more facilities to install additional MIE. Healthcare organizations need reliable information regarding comprehensive energy use or lifetime energy costs with which to make energy-efficient MIE procurement decisions, and there are currently no MIE energy or efficiency standards in the United States (U.S.). This fact sheet provides background on MIE energy consumption, key terms, and guidance on why and how to meter MIE, helping stakeholders make informed decisions to enhance their facility's performance.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Opaque Envelopes: Pathway to Building Energy Efficiency and Demand Flexibility: Key to a Low-Carbon, Sustainable Future

The opaque envelope - the barrier that helps maintain comfortable indoor conditions regardless of prevailing outdoor conditions - is the single largest contributor to primary energy use in residential and commercial buildings. Residential and commercial buildings comprise 39% of total U.S. primary energy use [1]. The opaque envelope affects 25% of building energy use, or 10% of total U.S. primary energy use [2]. High-performance opaque envelope technologies, therefore, have substantial potential to reduce energy use in both new construction and existing buildings. Retrofits are particularly crucial to realizing the energy savings potential of the opaque envelope because nearly 85% of residential and 55% of commercial buildings that exist today will still exist in 2050 [1]. Building envelope performance is also important for occupant comfort, productivity, health, and well-being. Improving the energy performance of the opaque envelope in U.S. buildings is critical to achieving aggressive cli- mate goals that support a clean energy economy and an equitable energy future for all Americans. By reducing total building energy use and improving energy efficiency, envelope research and development (R&D) will have a significant impact on how low-carbon buildings can mitigate climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Energy Storage Using Solid Particles for Long-Duration Energy Storage

The rapid growth of renewable energy increases the importance of economically firming the electricity supply from variable solar photovoltaic- and wind-power generators. Energy storage will be the key to manage variability and to bridge the generation gap over time scales of hours or days for high renewable grid integration. The integration of renewable power and storage of excess electricity has several significant and positive impacts including: 1) expanding the renewable energy portion of total electricity generation, 2) improving the peak-load response, and 3) coordinating the electricity supply and demand over the grid. Long-duration energy storage can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Several energy storage methods are deployed or under development, including mechanical, chemical or electrochemical, and thermal energy storage (TES). Comparing their economic potential for different scales and applications helps identify suitable technology to support high renewable grid integration. Despite the progress of TES technologies developed and deployed with concentrating solar power (CSP) systems, TES has been undervalued for its potential role in electric energy storage. This paper introduces TES methods applicable to grid energy storage and particularly focuses on solid-particle-based TES to serve the purpose of long-duration energy storage (LDES). The objective of this paper is to present a standalone particle-based TES system for electric storage and to show the potential of TES systems for LDES applications over other energy storage methods such as batteries, compressed-air energy storage, or pumped-storage hydropower.

27 ARPA - Advanced Research Projects Agency-Energy↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Low Energy Ultrasonic Separation

Separations exist in all manufacturing sectors, accounting for 22% of in-plant energy use. Whereas energy-intense technologies such as centrifuges are well established, low energy separations account for only 1% of industrial energy consumption. Researchers at Los Alamos National Lab are developing a low energy ultrasonic particle concentrator for industry. This technology may reduce energy use, improve separations, reduce wastes, and cut manufacturing costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative techno-economic and environmental analysis of using nuclear energy and fossil energy with carbon sequestration in U.S. Gulf Coast petroleum refineries

U.S. Gulf Coast refineries have processing capacity of approximately 9.4 million barrels of crude oil per day—about 50% of U.S. national capacity—while consuming natural gas, electricity, and hydrogen, resulting in approximately 100 million metric tonnes (MMT) of onsite CO₂ emissions in 2022. This study evaluates two alternative refinery energy supply pathways: nuclear energy (NE) and fossil energy-derived hydrogen with carbon capture and sequestration (FE-CCS; autothermal reforming), intermittent renewable sources are not considered as they cannot reliably meet continuous industrial heat and hydrogen demands. Using publicly available data for refineries, we conducted a bottom-up, facility-level assessment to estimate energy use by type, well-to-gate refinery emissions, and associated costs of integration. Compared to current refinery operations using natural gas energy supply and conventional hydrogen production (steam methane reforming without sequestration), NE and FE-CCS could produce, respectively, average emissions reductions of 37% and 42%, total abatement costs of $\$$52–$\$$221 and $\$$211–$\$$612/MT CO₂, and additional costs of about $\$$0.2–$\$$6 and $\$$3–$\$$11 per barrel of crude, respectively. Our analysis indicates that 25 out of 27 refineries have lower total additional cost ($\$$/bbl.) for the NE scenario than the FE-CCS scenario, making a strong case for NE integration with petroleum refineries. This work's main contribution is a detailed bottom-up refinery-level analysis method that can be utilized by the worldwide refining industry and stakeholders as they assess different technological options, along with their costs and environmental impacts for a specific refinery operation.

Carbon capture and sequestration↗

OSEII (Open-Source Energy Intensity Indicators)

Energy Intensity Indicators provides a framework to quantify how energy efficiency may or may not be affecting energy use relative to other economic trends. The model enables the decomposition of energy use for economic sectors through the use of a Log Mean Divisia Index (LMDI) model. The LMDI methodology decomposes energy use into three main categories: activity, structure and intensity (i.e. energy efficiency). A user can thus explain changes to overall energy use in a sector through changes to sector output (activity), structural shifts within sectors (e.g. across transportation modes), and efficiency of energy use in that sector.

Rabideau, Isabelle↗

Utility-scale Building Type Assignment Using Smart Meter Data

United States building energy use accounted for 40% of total energy use, 74% of peak demand, and $412 billion in 2019. Building energy modeling allows researchers to simulate building physics, gain insights into possible energy/demand saving opportunities, and assess cost-effective resilience amidst climate change. Many building features needed to create building energy models are readily available such as 2D footprints and LiDAR (height). A critical feature that is not generally obtainable is the building type. In partnership with a utility, a years worth of real-world, 15-minute electrical use data has been examined. The smart meter data is compared to 97 different prototype building energy models to assign building type. Real-world considerations including data preparation, quality assurance, and handling of missing values for advanced metering infrastructure data are addressed. Euclidean distance for pattern-matching of energy use, dynamic time warping, and time-window statistics with machine learning are compared for determining building type from measured electricity use.

Bass, Brett↗

Energy management systems for forecasted demand error compensation using hybrid energy storage system in nanogrid

This paper proposes an energy management system (EMS) for nanogrids to balance the power supply and forecasted demand in consideration of forecasting errors arising from high instantaneous demand. The proposed EMS employs a power-balancing optimization process for forecasted demand and a reference power modulation strategy for forecasting errors. This power-balancing optimization utilizes nanogrid sources, such as photovoltaics, fuel cells, and batteries, to meet forecasted demand and a supercapacitor charging process to overcome issues with a low energy density. The proposed reference power modulation strategy is utilized to allocate power from a hybrid energy storage system consisting of a battery and supercapacitor in order to compensate for forecasting errors. In addition, this proposed strategy considers battery and supercapacitor constraints such as the power changing rate and total power limitations. Further, the power-balancing optimization process also operates at faster sampling rate than the reference power modulation process in order to improve the computational efficiency. The performance of the proposed EMS is evaluated using real data obtained from the Korea Electric Power Exchange.

25 ENERGY STORAGE↗

Per-instruction energy debugging using instruction sampling hardware

A processor utilizes instruction based sampling to generate sampling data sampled on a per instruction basis during execution of an instruction. The sampling data indicates what processor hardware was used due to the execution of the instruction. Software receives the sampling data and generates an estimate of energy used by the instruction based on the sampling data. The sampling data may include microarchitectural events and the energy estimate utilizes a base energy amount corresponding to the instruction executed along with energy amounts corresponding to the microarchitectural events in the sampling data. The sampling data may include switching events associated with hardware blocks that switched due to execution of the instruction and the energy estimate for the instruction is based on the switching events and capacitance estimates associated with the hardware blocks.

Wei, Shijia↗

Impacts of the morphology of new neighborhoods on microclimate and building energy

In anticipation of emerging global urbanization and consequent increases in energy use and carbon dioxide emissions, better understanding and quantification of climate effects on energy use in cities are needed, requiring coordinated research into large-scale, regional, and microclimate impacts to and from the city structure. The methodology described here addresses this need by (1) demonstrating a process for creating and testing example morphologies for new neighborhoods for their impact on local and regional meteorology within a two-way-coupled four-domain nested mesoscale weather model (6 km horizontal resolution outer domain, 90 m horizontal innermost domain) and (2) allocating resulting building-level meteorological profiles to each building in a neighborhood for parallel computation of building-by-building energy use. Our Chicago Loop test case shows that the morphology of even a small new added development to a neighborhood affects not only its own microclimate, but also the microclimate of the original neighborhood to which the development was added, and that these changes in microclimate affect both neighborhoods’ building energy use. Furthermore, this method represents an important step toward quantifying and analyzing the relationships among climatic conditions, urban morphology, and energy use and using these relationships to inform energy-efficient urban development and planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗