Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emulsions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Demixing of aqueous polymer two-phase systems in low gravity

Experiments on the effect of gravity on phase emulsion demixing were performed in order to study the potential of two-phase partitioning in space. The behavior of phase systems possessing phase density differences and systems with essentially identical phase densities was investigated during one-g and low-g parabolic aircraft maneuvers. It is found that demixing can occur rather rapidly in space, although more slowly than on earth. The Ostwald ripening theory predicts demixing rates many orders of magnitude lower than the observed values.

Bamberger, S.↗

Photopolymerization Of Levitated Droplets

Experimental containerless process combines two established techniques to make variety of polymeric microspheres. In single step, electrostatically-levitated monomer droplets polymerized by ultraviolet light. Faster than multiple-step emulsion polymerization process used to make microspheres. Droplets suspended in cylindrical quadrupole electrostatic levitator. Alternating electrostatic field produces dynamic potential along axis. Process enables tailoring of microspheres for medical, scientific, and industrial applications.

Rembaum, Alan↗

In-reach and out-reach programs

Information is given in viewgraph form on in-reach and out-reach programs in in-space technology experiments. Information is given on thermal energy storage materials technology, industry/university in-space technology experiments, heat pipe performance, working fluid behavior, a tank pressure control experiment, spacecraft glow, the Mid-Deck Zero-Gravity Dynamics Experiment, and emulsion chamber technology.

Pyle, Jon S.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Expanding the utility of manned observations of earth - 70 mm film tests on the Space Shuttle

The Space Shuttle Orbiter provides opportunities for testing different ways to record terrestrial scenes using film. Such opportunities are limited by launch schedules and orbital parameters, properties of the Orbiter windows, available astronaut time and equipment stowage, and the necessity for safety qualification of equipment. To date, astronauts have accomplished several successful tests using color-infrared film, plane-polarizing filters, and a faster color emulsion, both on single 70-mm cameras and using a dual camera mount.

Amsbury, David L.↗

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.↗

JACEE long duration balloon flights

JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1 to 100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed.

Burnett, T.↗

New calculations and measurements of the Coulomb cross-section for the production of direct electron pairs by high energy nuclei

Recently, new calculations were made of the direct Coulomb pair cross section that rely less in arbitrary parameters. More accurate calculations of the cross section down to low pair energies were made. New measurements of the total direct electron pair yield, and the energy and angular distribution of the electron pairs in emulsion were made for O-16 at 60 and 200 GeV/amu at S-32 at 200 GeV/amu which give satisfactory agreement with the new calculations. These calculations and measurements are presented along with previous accelerator measurements made of this effect during the last 40 years. The microscope scanning criteria used to identify the direct electron pairs is described. Prospects for application of the pair method to cosmic ray energy measurements in the region 10 (exp 13) to 10 (exp 15) eV/amu are discussed.

Derrickson, J. H.↗

Direct measurement of the composition and spectra of cosmic rays above 1 TeV/amu from JACEE

Direct measurements on cosmic ray protons through iron above about 1 TeV/amu have been performed in a series of balloon-borne experiments with emulsion chambers. The measured energy spectra of protons and helium are power laws with exponents of 2.77 + or - 0.09 and 2.72 + or - 0.11 in the energy range 5 to 500 TeV and 2 to 50 TeV/amu, respectively. The proton spectrum shows no evidence of the steepening near 2 TeV which was reported by other experiments. Helium has a slightly higher intensity compared to extrapolations from lower energy measurements. The heavier elements, carbon to sulfur, show a small tendency for intensity enhancement in the relative abundance obove 10 TeV/amu.

Parnell, T. A.↗

Energy spectra of cosmic rays above 1 TeV per nucleon

Direct measurements of cosmic-ray nuclei above 1 TeV/nucleon have been performed in a series of balloon-borne experiments with emulsion chambers. The observed all-particle spectrum above 20 TeV is consistent with the results of the Proton satellite and many air shower experiments. The proton spectrum is consistent with a power law having an index of 2.76 + or - 0.09 up to at least 100 TeV, but an overabundance of helium by a factor of 2 above 2 TeV per nucleon is found when compared with the extrapolation from the low energies. For heavy elements (C through Fe), the intensities around 1 TeV/nucleon are consistent, within the statistical errors, with the extrapolation from lower energy data using the Spacelab 2 spectral indices. An enhancement for the medium-heavy components (C through Ca) above 200 TeV is indicated. The mean mass above 50 TeV indicates slightly higher values than the results of the air shower experiments.

Burnett, T. H.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

Thermodynamic properties and crystallization kinetics at high liquid undercooling

The heat capacities of liquid and crystalline Au-Pb-Sb alloys in the glass-forming composition range were measured with droplet emulsion and bulk samples. Based on the measured C(sub p) data, the entropy, enthalpy, and Gibbs free energy functions of the eutectic, solid mixture, and undercooled liquid were determined as a function of undercooling and compared with theoretical predictions. The results indicate an isentropic temperature at 313 + or - 5 K, which agrees well with experimental data for the glass transition. A kinetics analysis of the nucleation undercooling response suggests that the proper choice for the Gibbs free energy change during crystallization is most important in analyzing the nucleation kinetics. By classical nucleation theory, the prefactors obtained, based on a variety of theoretical predictions for the driving force, can differ by six orders of magnitude. If the nucleation rates are extrapolated to high undercooling, the extrapolations based on measured heat capacity data show agreement, whereas the predicted nucleation rates are inconsistent with results from drop tower experiments. The implications for microg experiments are discussed.

Fecht, Hans J.↗

Spectra, composition and interactions of nuclei above 10 TeV using magnet-interferometric chambers (SCIN/MAGIC)

Initial definition studies were performed for the SCIN/MAGIC experiment selected as an Astromag investigation on Space Station Freedom. The study focused on Science Objectives and Science Requirement, Accommodation on both the STS and the Astromag facility, Data extraction techniques and Background Studies. The detectors are emulsion chambers which will be exposed for approximately 90 days and then recovered from orbit for subsequent processing and analysis in the laboratory. Such a technique is the only means to obtain information on the ultrahigh energy cosmic rays and their nuclear interactions. The SCIN/MAGIC investigation can supply unique data in relatively unexplored energy region and address many of the fundamental questions in particle astrophysics.

Wefel, John P.↗

Improved Capacitive Liquid Sensor

Improved capacitive sensor used to detect presence and/or measure thickness of layer of liquid. Electrical impedance or admittance of sensor measured at prescribed frequency, and thickness of liquid inferred from predetermined theoretical or experimental relationship between impedance and thickness. Sensor is basically a three-terminal device. Features interdigitated driving and sensing electrodes and peripheral coplanar ground electrode that reduces parasitic effects. Patent-pending because first to utilize ground plane as "shunting" electrode. System less expensive than infrared, microwave, or refractive-index systems. Sensor successfully evaluated in commercial production plants to characterize emulsions, slurries, and solutions.

Waldman, Francis A.↗

JACEE long duration balloon flights

JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1 to 100A TeV. Experiments with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed.

Burnett, T.↗

Flow-induced gelation of living (micellar) polymers

The effect of shear velocity gradients on the size (L) of rodlike micelles in dilute and semidilute solution is considered. A kinetic equation is introduced for the time-dependent concentration of aggregates of length L, consisting of 'bimolecular' combination processes L + L-prime yield (L + L-prime) and unimolecular fragmentations L yield L + (L - L-prime). The former are described by a generalization (from spheres to rods) of the Smoluchowski mechanism for shear-induced coalesence of emulsions, and the latter by incorporating the tension-deformation effects due to flow. Steady-state solutions to the kinetic equation are obtained, with the corresponding mean micellar size evaluated as a function of the Peclet number P (i.e., the dimensionless ratio of the flow rate and the rotational diffusion coefficient). For sufficiently dilute solutions, only a weak dependence of the micellar size on P is found. In the semidilute regime, however, an apparent divergence in the micellar size at P of about 1 suggests a flow-induced first-order gelation phenomenon.

Bruinsma, Robijn↗

On-line process analysis innovation: DiComp (tm) shunting dielectric sensor technology

The DiComp Shunting Dielectric Sensor (SDS) is a new patent-pending technology developed under the Small Business Innovation Research Program (SBIR) for NASA's Kennedy Space Center. The incorporation of a shunt electrode into a conventional fringing field dielectric sensor makes the SDS uniquely sensitive to changes in material dielectric properties in the KHz to MHz range which were previously detectable only at GHz measurement frequencies. The initial NASA application of the SDS for Nutrient Delivery Control has demonstrated SDS capabilities for thickness and concentration measurement of Hoagland nutrient solutions. The commercial introduction of DiComp SDS technology for concentration and percent solids measurements in dispersions, emulsions and solutions represents a new technology for process measurements for liquids in a variety of industries.

Davis, Craig R.↗