Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emergency operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Unified description of DGLAP, CSS, and BFKL evolution: TMD factorization bridging large and small x

This paper introduces a transverse-momentum dependent (TMD) factorization scheme designed to unify both large and small Bjorken-x regimes. We compute the next-to-leading order quantum chromodynamics (QCD) corrections to the gluon TMD operator for an unpolarized hadron within this proposed scheme. This leads to the emergence of a new TMD evolution, incorporating those in transverse momentum, rapidity, and Bjorken-x. When matched to the collinear factorization scheme, our factorization scheme faithfully reproduces the well-established Dokshitzer-Gribov-Lipatov-Altarelli-Parisi and Collins-Soper-Sterman (CSS) evolutions. Conversely, matching with high-energy factorization not only yields the Balitsky-Fadin-Kuraev-Lipatov evolution but also reveals distinctive signatures of CSS logarithms. The development of this novel TMD factorization scheme, capable of seamlessly reconciling disparate Bjorken-x regimes and faithfully reproducing established QCD evolution equations, has the potential to significantly advance our comprehension of high-energy processes and three-dimensional parton structures of hadrons. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Iterative ML and Experiments for Emerging VOCs

SAND2026-17074O Iterative ML and Experiments for Emerging VOCs is a tool that analyzes and predicts the behaviors of SARS-CoV-2 variants. It processes experimental data on ACE2 (the receptor for the SARS-CoV-2 virus that allows it to infect the cell) and antibody binding using machine learning models, including neural networks, to forecast ACE2 interactions and variant expression. The tool employs transfer learning and global epistasis modeling, integrating public datasets with proprietary data to enhance prediction accuracy. Additionally, it fits concentration-response curves to determine dissociation constants and generates visualizations to support research findings, thereby aiding in the identification of new antibodies for emerging variants of concern. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Sheffield, Thomas [Sandia National Lab. (SNL-NM), ↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Networked Microgrid Energy Management Considering Ownership and Control Structures: A Comparison

With the growing deployment of microgrids, networked microgrids have emerged for their additional advantages of economy, reliability and resilience by coordinating the operation of multiple microgrids. As microgrids are operated with different ownership, objectives and functionalities, the formed networked microgrids show characteristics of mixed ownership, inconsistent objectives and various functionalities. To enable the coordinated operation of networked microgrids, three control structures, i.e., centralized, distributed and decentralized, have been constructed in the literature. However, the data sharing enabling these different paradigms and the resulted value propositions are not well defined, leading to poor resource management and resilience, etc. To solve this issue, a complete comparison of networked microgrid energy management under centralized, distributed and decentralized structures are performed. As a novel contribution, the required minimum data exchange of networked microgrid energy management under three control structures are identified, respectively. The value propositions are calculated and compared against each other by the results of case studies.

control structures↗

Making Grid-interactive Efficient Buildings a “Win” for Both Customers and Utilities

Buildings account for more than 70% of U.S. electricity use and at least one-third of U.S. economy-wide CO2 emissions. Changing the timing and overall amount of electricity consumption in buildings would significantly reduce energy costs to consumers and facilitate the transition to a decarbonized economy. Grid-interactive efficient buildings (GEBs) incorporate energy efficiency, smart technologies, and active use of distributed energy resources (DERs) to provide these benefits. As the link between the customer and the power system, utilities are central to widespread deployment of GEBs. Yet, despite the significant cost savings and operational benefits of GEBs for utilities, deployment has remained limited. This paper explores emerging models for enabling utilities to facilitate GEB adoption. Building off foundational research conducted to develop the U.S. DOE’s A National Roadmap for Grid-Interactive Efficient Buildings, we describe the most novel recent examples of ways in which utilities and regulators have made demand-side innovation a win for both the customer and the utility. Emerging concepts include: (1) performance incentive mechanisms to align GEB deployment with utility financial motivations, (2) the use of subscription pricing (i.e., fixed monthly bills) to promote load flexibility and energy efficiency, (3) rate-basing utility-controlled behind-the-meter assets, and (4) coupling energy efficiency and load flexibility with electrification proposals to ensure that customer benefits are maximized. The paper concludes with a discussion about prospects for widespread GEB deployment and utilization by utilities, and how to scale efforts.

Satchwell, Andrew↗

Adaptive Power System Emergency Control using Deep Reinforcement Learning

Power system emergency control is generally regarded as the final safety net for grid security and resiliency. Existing emergency control schemes are usually designed off-line based on either the conceived “worst” case scenarios or a few typical operation scenarios. These schemes are facing significant adaptiveness and robustness issues as increasing uncertainties and variations occur in modern electrical grids. To address these challenges, for the first time, this paper proposes a novel adaptive emergency control scheme using deep reinforcement learning (DRL), by leveraging the high-dimensional feature extraction and non-linear generalization capabilities DRL has for complex systems with high-dimensional variations. Furthermore, an open-source platform named DeepGrid has been designed for the first time to assist the DRL development and benchmarking processes in power system emergency control. Details of the platform, DRL, and emergency control schemes that use dynamic braking or under-voltage load shedding are presented. Extensive case studies performed in both two-area four-machine system and IEEE 39-Bus system have demonstrated the excellent performance and robustness of the proposed schemes.

Deep reinforcement learning, emergency control, lo↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operator origin of anomalous dimensions in de Sitter space

The late-time limit of the power spectrum for heavy (principal series) fields in de Sitter (dS) space yields a series of polynomial terms with complex scaling dimensions. Such scaling behavior is expected to result from an associated operator with a complex dimension. In a free theory, these complex dimensions are known to match the constraints imposed by unitarity on the space of states. Yet, perturbative corrections to the scaling behavior of operators are naively inconsistent with unitary evolution of the quantum fields in dS space. This paper demonstrates how to compute one-loop corrections to the scaling dimensions that appear in the two-point function from the field theory description in terms of local operators. We first show how to evaluate these anomalous dimensions using Mellin space, which has the feature that it naturally accommodates a scaleless regulator. We then explore the consequences for the soft de Sitter effective theory (SdSET) description that emerges in the long wavelength limit. Carefully matching between the UV and SdSET descriptions requires the introduction of novel nondynamical “operators” in the effective theory. This is not only necessary to reproduce results extracted from the Källén-Lehmann representation (that use the space of unitary states directly), but it is also required by general arguments that invoke positivity. Published by the American Physical Society 2025

Cohen, Timothy↗

Municipal Adaptation to Changing Curbside Demands: Findings from Semi-Structured Interviews with Ten U.S. Cities

Emerging mobility services (e.g. ride-hailing, e-commerce, micro-mobility, etc.), are generating novel and rapidly growing demands to use curbside space, with potentially large impacts on mobility, energy consumption, and related outcomes. This presents both opportunities and challenges to municipal agencies responsible for managing this interface between the road network and adjacent land uses, as legacy practices require updating. In this study, we employ a semi-structured interviewing approach to establish how municipalities are adapting to these new pressures on their curbside. We interviewed senior staff responsible for curbside policy of ten large U.S. municipalities, with populations ranging from ~250,000 to ~5,000,000 (and the majority of which are the central city of their metropolitan region). We document a trend of organizational restructuring to more formally include curbside management teams, with the majority of interviewees also reporting increased staffing. Respondents reported that operational failures at their curbside (e.g. demand in excess of capacity) have impacts on safety, capacity, and emergency vehicle mobility, with impacts highly concentrated spatially and temporally (e.g. late evenings in nightlife districts). We document a diversity of data flows between ride-hailing operators (e.g. Uber, Lyft) and municipalities, with some cities reporting obtaining types of data that other cities report not receiving, despite requesting such data. Finally, respondents consistently expressed a desire for new data streams and methodologies to help manage the curbside of the future. It is hoped that establishing the state of practice in this rapidly changing context will be of use to practitioners facing similar pressures as those of our interviewees.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

The threat of a disaster happening at the Savannah River Site (SRS) is low, but not zero. When an emergency arises, emergency responders utilize a variety of tools to detect, track, and mitigate the disaster. HYSPLIT is a community atmospheric dispersion model that is highly configurable and has been used operationally to simulate particle, chemical, and radionuclide releases. We have developed a preliminary user interface (UI) that configures HYSPLIT to run for a variety of Emergency Action Level (EAL) scenarios at SRS. Using a hypothetical EAL scenario of an accidental release of Pu-238 in H-area and K-area onsite, an analysis was done to show how a preliminary UI framework allows HYSPLIT to be run on a terminal without the need form an active network connection. The study was successful in multiple aspects. For the preliminary UI, users were able to input certain characteristics of the hypothetical EAL such as hours of emission (how long was Pu-238 being released), curies of release, release start time (when does the model run start), and type of radionuclide directly into the terminal. For HYSPLIT, the model was successful in being able to take the UI input, calculate the results from the inputs and output multiple figures of both total volumetric airborne concentrations and surface deposition. We used the Pu-238 Derived Intervention Level (DIL) deposition thresholds for produce, dairy, and beef for visualization of the surface deposition, showing how a release would impact ingestion pathways.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

Protonic nickelate device networks for spatiotemporal neuromorphic computing

Computation in biological neural circuits arises from the interplay of nonlinear temporal responses and spatially distributed dynamic network interactions. Replicating this richness in hardware has remained challenging, as most neuromorphic devices emulate only isolated neuron- or synapse-like functions. Here we introduce an integrated neuromorphic computing platform in which both nonlinear spatiotemporal processing and programmable memory are realized within a single perovskite nickelate material system. By engineering symmetric and asymmetric hydrogenated NdNiO 3 junction devices on the same wafer, we combine ultrafast, proton-mediated transient dynamics with stable multilevel resistance states. Networks of symmetric NdNiO 3 junctions exhibit emergent spatial interactions mediated by proton redistribution, while each node simultaneously provides short-term temporal memory, enabling nanosecond-scale operation with an energy cost of ~0.2 nJ per input. When interfaced with asymmetric output units serving as reconfigurable long-term weights, these networks allow both feature transformation and linear classification in the same material system. Leveraging these emergent interactions, the platform enables real-time pattern recognition and achieves high accuracy in spoken digit classification and early seizure detection, outperforming temporal-only or uncoupled architectures. These results position protonic nickelates as a compact, energy-efficient, CMOS-compatible platform that integrates processing and memory for scalable intelligent hardware.

Electrical and electronic engineering↗

Nuclear Safety [Vol. 37, No. 2, April-June 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 97 The Nuclear Community and the Public: Cognitive and Cultural Influences on Thinking About Nuclear Risk, M. A. Meyer; 109 Twenty-Third Water Reactor Safety Information Meeting, D. A. Copinger; ACCIDENT ANALYSIS: 126 Analysis of a PWR LBLOCA Without SCRAM, Trevor N. Tyler, Rafael Macian-Juan and John H. Mahaffy; DESIGN FEATURES: 139 Vulnerability of Multiple-Barrier Systems, N. C. Lind; ENVIRONMENTAL EFFECTS: 149 A Study of Wet Catalytic Oxidation of Radioactive Spent Ion Exchange Resin by Hydrogen Peroxide, Xingchao Jian, Tianbao Wu, and Guichun Yun; 157 A Comparison Study and Resolution of Differences Between Emergency Response and Safety Analysis Codes Used at the Savannah River Site, A. A. Simpkins; OPERATING EXPERIENCES: 164 Reactor Shutdown Experience, Compiled by J. W. Cletcher; RECENT DEVELOPMENTS: 167 Reports, Standards, and Safety Guides, D. S. Queener; 172 Proposed Rule Changes as of Dec. 31,1995; ANNOUNCEMENTS: 178 American Nuclear Society 1997 Annual Meeting; 178 American Nuclear Society Nuclear Criticality and Safety Division Topical Meeting; 176 The Authors.

05 NUCLEAR FUELS↗

Nuclear Safety [Vol. 37, No. 2, April-June 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 97 The Nuclear Community and the Public: Cognitive and Cultural Influences on Thinking About Nuclear Risk, M. A. Meyer; 109 Twenty-Third Water Reactor Safety Information Meeting, D. A. Copinger; ACCIDENT ANALYSIS: 126 Analysis of a PWR LBLOCA Without SCRAM, Trevor N. Tyler, Rafael Macian-Juan and John H. Mahaffy; DESIGN FEATURES: 139 Vulnerability of Multiple-Barrier Systems, N. C. Lind; ENVIRONMENTAL EFFECTS: 149 A Study of Wet Catalytic Oxidation of Radioactive Spent Ion Exchange Resin by Hydrogen Peroxide, Xingchao Jian, Tianbao Wu, and Guichun Yun; 157 A Comparison Study and Resolution of Differences Between Emergency Response and Safety Analysis Codes Used at the Savannah River Site, A. A. Simpkins; OPERATING EXPERIENCES: 164 Reactor Shutdown Experience, Compiled by J. W. Cletcher; RECENT DEVELOPMENTS: 167 Reports, Standards, and Safety Guides, D. S. Queener; 172 Proposed Rule Changes as of Dec. 31,1995; ANNOUNCEMENTS: 178 American Nuclear Society 1997 Annual Meeting; 178 American Nuclear Society Nuclear Criticality and Safety Division Topical Meeting; 176 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗