At least 397 records · Page 22

Measurements of Breakdown Field and Forward Current Stability in 3C-SiC P-N Junction Diodes Grown on Step-Free 4H-SiC

This paper reports on initial fabrication and electrical characterization of 3C-SiC p-n junction diodes grown on step-free 4H-SiC mesas. Diodes with n-blocking-layer doping ranging from approx. 2 x 10(exp 16)/cu cm to approx.. 5 x 10(exp 17)/cu cm were fabricated and tested. No optimization of junction edge termination or ohmic contacts was employed. Room temperature reverse characteristics of the best devices show excellent low-leakage behavior, below previous 3C-SiC devices produced by other growth techniques, until the onset of a sharp breakdown knee. The resulting estimated breakdown field of 3C-SiC is at least twice the breakdown field of silicon, but is only around half the breakdown field of <0001> 4H-SiC for the doping range studied. Initial high current stressing of 3C diodes at 100 A/sq cm for more than 20 hours resulted in less than 50 mV change in approx. 3 V forward voltage. 3C-SiC, pn junction, p+n diode, rectifier, reverse breakdown, breakdown field,heteroepitaxy, epitaxial growth, electroluminescence, mesa, bipolar diode

Neudeck, Philip G.↗

Progresses in Developing Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

Development of the novel patented high voltage insulation system, namely micro-multilayer multifunctional electrical insulation (MMEI) was continued particularly for the future hybrid or all electric aircraft applications. Initially, the concept and feasibility of the MMEI system were successfully demonstrated with its exceptionally high dielectric breakdown voltage via optimizing the multilayer structures of the Kapton® PI films and binder layers such as PFA in terms of individual film thickness and layer configuration. Overall, MMEI structures outperformed most of the state-of-the-art (SOA) polymer insulation materials or structures. Since then, further optimizations and improvement of the system were pursued with specific emphasis on multifunctionalities such as moisture blocking, partial discharge (PD) resistance, durability, etc. Efforts have been also continued to identify the controlling mechanisms for the major improvement in dielectric strength of the MMEI structures via 3-dimensional dielectric failure mode analysis. At the same time, significant progress has been made in scaling up the MMEI structures and assessing their commercial applicability and manufacturability by developing full-scale prototypes of electrical components, such as power cable and bus bar. Overall progresses on the MMEI development to date will be presented in this paper.

Novel Electrical Insulation↗

Elemental Analyses of Hypervelocity Microparticle Impact Sites on Interplanetary Dust Experiment Sensor Surfaces

The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to breakdown the 0.4 or 1.0 micron thick SiO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results classification resulted from the particles' origins as 'manmade', 'natural', or 'indeterminate'. The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters, of these features. Thus far, a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF were analyzed: 36 from tray C-9 (Leading (ram), or east, side), 18 from tray C-3 (Trailing (wake), or west, side), 12 from tray B-12 (north side), 4 from tray D-6 (south side), 3 from tray H-11 (space end), and 6 from tray G-10 (earth end). Residue from manmade debris was identified in craters on all trays (aluminum oxide particle residues were not detectable on the Al/Si substrates). These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the west, space, and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the east, north, and south sides of the satellite, denoting passage through orbital debris clouds or rings.

Simon, C. G.↗

Effect of Mechanical Deformation on the Dielectric Electric Field in Dynamic Umbilical Cables

Wave energy converter (WEC) systems have unique umbilical cable design requirements compared to conventional marine designs. Due to their dynamic nature, WEC umbilical cables are required to handle increased loads and larger motions over longer deployment scenarios. However, the life expectancy of dynamic umbilical cables is predominantly analyzed for mechanical fatigue, with little consideration given to the effect of mechanical stress on the response of the dielectric as it has been previously assumed that the non-polymeric components will fail prior to the polymeric components. In this work, we explore the effects of mechanical bending on the concentration of the electric field in the insulation of a conceptual three-core dynamic umbilical cable to determine the limiting requirements for life expectancy. A conceptual industrial schematic of a medium voltage dynamic umbilical cable was used as the basis for the WEC system under study. Simulations on the dynamic umbilical cable were performed using COMSOL Multiphysics®. Mechanical loads up to the calculated limit (2.64 m minimum bend radius or 388 kN transverse load) were applied to the dynamic umbilical in a step-wise fashion with one end of the umbilical cable fixed. One-way coupling in three-dimensions was conducted by first determining the engineering strains, then using the engineering strains as the initial condition for determination of the Green-Lagrange strains, and lastly calculating the electric field in the deformed dielectric. Based upon the input load, deformation of the dielectric at the minimum bend radius produced an increase in the electric field of more than 12% when compared to the undeformed umbilical cable, which may lead to dielectric breakdown of the insulation prior to mechanical failure of the umbilical cable.

Spencer, Mychal P.↗

RF multicoupler design techniques to minimize problems of corona, multipaction, and stability

A mathematical expression was derived describing multipacting and corona effects in a coaxial cavity. Both mechanical and electrical design techniques were investigated to minimize the susceptibility of coaxial cavity to corona and multipacting-type breakdown. To assist in the design of a multicoupler free from corona and multipactor breakdown, a flow chart obtained from the derived mathematical expression is included.

Hurley, H. S.↗

Contamination control in hybrid microelectronic modules. Part 2: Selection and evaluation of coating materials

The selection, test, and evaluation of organic coating materials for contamination control in hybrid circuits is reported. The coatings were evaluated to determine their suitability for use as a conformal coating over the hybrid microcircuit (including chips and wire bonds) inside a hermetically sealed package. Evaluations included ease of coating application and repair and effect on thin film and thick film resistors, beam leads, wire bonds, transistor chips, and capacitor chips. The coatings were also tested for such properties as insulation resistance, voltage breakdown strength, and capability of immobilizing loose particles inside the packages. The selected coatings were found to be electrically, mechanically, and chemically compatible with all components and materials normally used in hybrid microcircuits.

Himmel, R. P.↗

Macroscopic T nonconservation - Prospects for a new experiment

Breakdown of time-reversal invariance can be detected in macroscopic samples as a magnetic alignment along an electric field. It is shown that both fundamental and practical limits to the detection of this effect in paramagnets correspond to measurement of electron electric dipole moments down to d(e) of about 10 to the -28th e cm on 50-g quantities of EuS near its Curie point; this compares to the current limit of d(e) not greater than 10 to the -24th e cm. Strategies for still greater sensitivity are outlined.

Bialek, W.↗

Controlling Triboelectrification Effects on Spacecraft Ethernet Cabling

Triboelectric charging of a spacecraft and launch vehicles on ascent may occur due to the process of contact and separation between the vehicle skin and aerosols, dust, ice, water droplets, smoke, and other particulates encountered in the flight path. Depending on characteristics at the atomic and molecular levels of the vehicle skin’s surface and the substances and particulates encountered, electrical charge will transfer between the vehicle and the encountered substances, resulting in an accumulation of electrical charge on the vehicle skin. If the vehicle skin is conductive and electrically bonded such that in its entirety it presents an equipotential surface, then the accumulated electrical charge will spread in a nearly uniform manner leaving all regions with a nearly equal potential with respect to each other and the surrounding environment. Regions that are not electrically bonded as described, or surfaces that have resistivity values, can reach different potentials than the surrounding surfaces. When this happens, the differing potentials may grow to very large magnitudes, leading to electrostatic discharge events between the regions. As the vehicle rises in altitude, the breakdown potential between these regions of differing potential decreases commensurate with decreases in atmospheric density and pressure. If the potential differences between surfaces of the vehicle become equal to or exceed the breakdown potential, one or more discharge events may occur, each of them generating voltage and current transients that can easily damage or interfere with the designed operation of on-board electrical, avionic, and communications and navigation systems. This lesson learned discusses an in-flight anomaly caused by triboelectric discharge events and exacerbated by the lack of adequate cable shielding that affected flight computer communication links. Also discussed are mitigations to prevent this occurrence.

Ethernet↗

Observation of well-defined Kohn-anomaly in high-quality graphene devices at room temperature

Abstract Due to its ultra-thin nature, the study of graphene quantum optoelectronics, like gate-dependent graphene Raman properties, is obscured by interactions with substrates and surroundings. For instance, the use of doped silicon with a capping thermal oxide layer limited the observation to low temperatures of a well-defined Kohn-anomaly behavior, related to the breakdown of the adiabatic Born–Oppenheimer approximation. Here, we design an optoelectronic device consisting of single-layer graphene electrically contacted with thin graphite leads, seated on an atomically flat hexagonal boron nitride substrate and gated with an ultra-thin gold layer. We show that this device is optically transparent, has no background optical peaks and photoluminescence from the device components, and no generation of laser-induced electrostatic doping (photodoping). This allows for room-temperature gate-dependent Raman spectroscopy effects that have only been observed at cryogenic temperatures so far, above all the Kohn-anomaly phonon energy normalization. The new device architecture, by decoupling graphene optoelectronic properties from the substrate effects, allows for observing quantum phenomena at room temperature.

Materials Science↗

Physical and Electrical Characterization of Aluminum Polymer Capacitors

Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

Liu, David↗

Physical and Electrical Characterization of Polymer Aluminum Capacitors

Polymer aluminum capacitors from several manufacturers with various combinations of capacitance, rated voltage, and ESR values were physically examined and electrically characterized. The physical construction analysis of the capacitors revealed three different capacitor structures, i.e., traditional wound, stacked, and laminated. Electrical characterization results of polymer aluminum capacitors are reported for frequency-domain dielectric response at various temperatures, surge breakdown voltage, and other dielectric properties. The structure-property relations in polymer aluminum capacitors are discussed.

Liu, David↗

The electric fields and “lightning jets” of the Sun and solar wind

A model of electric energization of the solar wind and corona is developed, including electro-magnetic particle effects precluded by traditional magneto-hydro (MHD) assumptions. Using standard 1D radial solar models for particle density and temperature, the core gravito-electric field is calculated; and the range of possible photospheric photo-electric fields is estimated. The extant DC field apparently arises from about 460 C of charge displacement, mainly caused by the immense solar energy flux pushing electrons outward. Energetically, this electric field can accelerate surface protons out of the 2 keV gravity well and up to the 4 keV energies observed in the fast solar wind. The electrical energy is released in pervasive, persistent “proton lightning jets,” which are proton beams, charge-neutralized by co-propagating electrons. The jets are formed by pinched “avalanche breakdown” of the weakly ionized photosphere, probably initiated on the down-welling edges of solar surface granulations. These energetic jets will glow as discrete filamentary surface spicules and will be observed in reflected solar light as the diffuse K-corona. Significantly, the total charge displacement and observed fast wind speed are quantitatively predicted by a novel “virial limit”: the (positive) electrical potential energy at r = 0 is limited in magnitude to the 10 keV gravitational well at r = 0.

Physics↗

Retail Rate Projections for Long-Term Electricity System Models

Electricity prices reported in most electricity-system planning studies leave out many price components and do not translate into retail rates, making it difficult to interpret how projected electricity system changes will impact costs to consumers. Full transmission costs are left out of many studies; distribution and administration costs are similarly excluded or highly simplified. Here, we present a detailed bottom-up accounting method for projecting future retail electricity rates in the United States. Making the simplifying assumption that each state is served by an investor-owned utility (IOU), we translate projected generation and transmission capacity and costs from the Regional Energy Deployment System (ReEDS) capacity-expansion model into IOU balance sheet expenditures, accounting for depreciation, taxes, and the breakdown between operating and capitalized (rate-based) expenses. Distribution, administration, and intra-regional transmission costs are projected forward based on empirical trends over the past decade. Modeled bottom-up electricity rates are compared to historical rates from 2010-2019, and the sensitivity of modeled rates to a range of financing and modeling assumptions is explored. Distribution and administration rate components account for roughly 40% (4.4 ¢/kWh) of the projected national-average retail rate over 2020-2050 under central assumptions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of UV, ns-laser damage resistance of hafnia films produced by electron beam evaporation and ion beam sputtering deposition methods

Laser-induced damage in coating materials with a high index of refraction, such as hafnia, limits the performance of high power and high energy laser systems. Understanding the underlying physics responsible for laser damage holds the key for developing damage-resistant optical films. Previous studies have reported a substantial difference in laser damage onset for hafnia films produced by different deposition methods, yet the underlying mechanisms for the observed difference remain elusive. We combined laser damage testing with analytical characterizations and theoretical simulations to investigate the response of hafnia films produced by electron (e-) beam evaporation vs ion beam sputtering (IBS) methods upon UV ns-laser exposure. We found that e-beam produced hafnia films were overall more damage resistant; in addition, we observed a polarization anisotropy associated with the onset of damage in the e-beam films, while this effect was absent in the latter films. The observed differences can be attributed to the stark contrast in the pressure inside the pores inherent in both films. The high pressure inside the IBS-induced nanobubbles has been shown to reduce the threshold for laser-induced plasma breakdown leading to film damage. The polarization effects in the e-beam coatings can be related to the asymmetric electric field intensification induced by the columnar void structure. Our findings provide a fundamental basis for developing strategies to produce laser damage-resistant coatings for UV pulsed laser applications.

36 MATERIALS SCIENCE↗

Solar-induced variations of environment affecting manned space flight and spacecraft operations

Estimates of short and long term solar activity are required for calculating variations in the environment with regard to spacecraft charging, radiation effects, and orbital lifetime. Correlations appear to exist between the time of solar activity and the time of operational anomalies due to electrical discharges when the dielectric surfaces of geosynchronous spacecraft are charged by interaction with the ambient plasma to levels above breakdown voltage. An ability to predict the solar induced variation variability of the plasmas could permit refinement of design criteria. The influence of the radiation on spacecraft materials, systems, and manned operations is summarized. Solar radition effects on the orbital altitude atmospheric density environment and spacecraft lifetimes are also considered.

Johnson, W. G.↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

Three tasks were undertaken to investigate reliability attributes of terrestrial solar cells: (1) a study of the electrical behavior of cells in the second (reverse) quadrant; (2) the accelerated stress testing of three new state-of-the-art cells; and (3) the continued bias-temperature testing of four block 2 type silicon cells at 78 C and 135 C. Electrical characteristics measured in the second quadrant were determined to be a function of the cell's thermal behavior with breakdown depending on the initiation of localized heating. This implied that high breakdown cells may be more fault tolerant when forced to operate in the second quadrant, a result contrary to conventional thinking. The accelerated stress tests used in the first (power) quadrant were bias-temperature, bias-temperature-humidity, temperature-humidity, thermal shock, and thermal cycle. The new type cells measured included an EFG cell, a polycrystalline cell, and a Czochralski cell. Significant differences in the response to the various tests were observed between cell types. A microprocessed controlled, short interval solar cell tester was designed and construction initiated on a prototype.

Lathrop, J. W.↗