Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR DETECTING CODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Water Vapor in Titan's Stratosphere from Cassini/CIRS Far-infrared Spectra

Since the first detection of water vapor in Titan's stratosphere by disk-average observations from the Infrared Space Observatory (Coustenis et al. 1998) we report here the successful detection of stratospheric water vapor using the Cassini Composite Infrared Spectrometer (CIRS, Flasar et al. 2004). CIRS senses water emissions in the far infrared spectral region near 50 microns, which we have modeled using two independent radiative transfer codes (NEMESIS, Irwin et al 2008 and ART, Coustenis et al. 2007, 2010). From the analysis of nadir spectra we have derived a mixing ratio of (0.14 0.05) ppb at an altitude of 97 kilometers, which corresponds to an integrated (from 0 to 600 kilometers) surface normalized column abundance of (3.7 plus or minus 1.3) x 10(exp 14) molecules per square centimeter. In the latitude range 80 S to 30 N we see no evidence for latitudinal variations in these abundances within the error bars. Using limb observations, we obtained mixing ratios of (0.13 plus or minus 0.04) ppb at an altitude of 115 kilometers and (0.45 plus or minus 0.15) ppb at an altitude of 230 kilometers, confirming that the water abundance has a positive vertical gradient as predicted by photochemical models (e.g. Lara et al. 1996, Wilson and Atreya 2004, Horst et al. 2008); retrieved scaling factors (from approximately 0.1 to approximately 0.6) to the water profile suggested by these models show that water vapor is present in Titan stratosphere with less abundance than predicted.

Cottini, V.↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping DNA polymerase errors by single-molecule sequencing

Genomic integrity is compromised by DNA polymerase replication errors, which occur in a sequence-dependent manner across the genome. Accurate and complete quantification of a DNA polymerase's error spectrum is challenging because errors are rare and difficult to detect. We report a high-throughput sequencing assay to map in vitro DNA replication errors at the single-molecule level. Unlike previous methods, our assay is able to rapidly detect a large number of polymerase errors at base resolution over any template substrate without quantification bias. To overcome the high error rate of high-throughput sequencing, our assay uses a barcoding strategy in which each replication product is tagged with a unique nucleotide sequence before amplification. Here, this allows multiple sequencing reads of the same product to be compared so that sequencing errors can be found and removed. We demonstrate the ability of our assay to characterize the average error rate, error hotspots and lesion bypass fidelity of several DNA polymerases.

60 APPLIED LIFE SCIENCES↗

NASA Tech Briefs, May 2011

Topics covered include: 1) Method to Estimate the Dissolved Air Content in Hydraulic Fluid; 2) Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes; 3) High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence; 4)Metrology Arrangement for Measuring the Positions of Mirrors of a Submillimeter Telescope; 5) On-Wafer S-Parameter Measurements in the 325-508-GHz Band; 6) Reconfigurable Microwave Phase Delay Element for Frequency Reference and Phase-Shifter Applications; 7) High-Speed Isolation Board for Flight Hardware Testing; 8) High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors; 9) 3D Orbit Visualization for Earth-Observing Missions; 10) MaROS: Web Visualization of Mars Orbiting and Landed Assets; 11) RAPID: Collaborative Commanding and Monitoring of Lunar Assets; 12) Image Segmentation, Registration, Compression, and Matching; 13) Image Calibration; 14) Rapid ISS Power Availability Simulator; 15) A Method of Strengthening Composite/Metal Joints; 16) Pre-Finishing of SiC for Optical Applications; 17) Optimization of Indium Bump Morphology for Improved Flip Chip Devices; 18) Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures; 19) Marshall Convergent Spray Formulation Improvement for High Temperatures; 20) Real-Time Deposition Monitor for Ultrathin Conductive Films; 21) Optimized Li-Ion Electrolytes Containing Triphenyl Phosphate as a Flame-Retardant Additive; 22) Radiation-Resistant Hybrid Lotus Effect for Achieving Photoelectrocatalytic Self-Cleaning Anticontamination Coatings; 23) Improved, Low-Stress Economical Submerged Pipeline; 24) Optical Fiber Array Assemblies for Space Flight on the Lunar Reconnaissance Orbiter; 25) Local Leak Detection and Health Monitoring of Pressurized Tanks; 26) Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging; 27) Automated Cryocooler Monitor and Control System; 28) Broadband Achromatic Phase Shifter for a Nulling Interferometer; 29) Super Dwarf Wheat for Growth in Confined Spaces; 30) Fine Guidance Sensing for Coronagraphic Observatories; 31) Single-Antenna Temperature- and Humidity-Sounding Microwave Receiver; 32) Multi-Wavelength, Multi-Beam, and Polarization-Sensitive Laser Transmitter for Surface Mapping; 33) Optical Communications Link to Airborne Transceiver; 34) Ascent Heating Thermal Analysis on Spacecraft Adaptor Fairings; 35) Entanglement in Self-Supervised Dynamics; 36) Prioritized LT Codes; 37) Fast Image Texture Classification Using Decision Trees; 38) Constraint Embedding Technique for Multibody System Dynamics; 39) Improved Systematic Pointing Error Model for the DSN Antennas; 40) Observability and Estimation of Distributed Space Systems via Local Information-Exchange Networks; 41) More-Accurate Model of Flows in Rocket Injectors; 42) In-Orbit Instrument-Pointing Calibration Using the Moon as a Target; 43) Reliability of Ceramic Column Grid Array Interconnect Packages Under Extreme Temperatures; 44) Six Degrees-of-Freedom Ascent Control for Small-Body Touch and Go; and 45) Optical-Path-Difference Linear Mechanism for the Panchromatic Fourier Transform Spectrometer.

Source record↗

Final Report Forensics City Transport 2012

This project was to demonstrate practical Monte Carlo transport calculational methods applied to city models in prompt forensics. Typically 1 source gamma ray in ~10 18 is physically detected in most real world scenarios for this class of problems. Major factors are detector solid angles at ~ km distances, building and air attenuation, as well as huge variations in source intensities. We used the world-wide standard for transport calculations, MCNP, developed at LANL. We used ARA supplied city models used in consequence management. One indication of the extreme difficulty of these problems is that the huge numbers were larger than the space allotted by the code developers and were output as “*********”. (LANL was very helpful in resolving multiple issues we encountered like this.) Hardware memory issues also needed to be resolved. Calculational success was achieved in the simpler WDC model by a combination of variance reduction, voxelized geometry eliminated the mcnp geometry errors in the NYC model, eliminating peripheral buildings, and convolution of the source terms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Parallel digital modem using multirate digital filter banks

A new class of architectures for an all-digital modem is presented in this report. This architecture, referred to as the parallel receiver (PRX), is based on employing multirate digital filter banks (DFB's) to demodulate, track, and detect the received symbol stream. The resulting architecture is derived, and specifications are outlined for designing the DFB for the PRX. The key feature of this approach is a lower processing rate then either the Nyquist rate or the symbol rate, without any degradation in the symbol error rate. Due to the freedom in choosing the processing rate, the designer is able to arbitrarily select and use digital components, independent of the speed of the integrated circuit technology. PRX architecture is particularly suited for high data rate applications, and due to the modular structure of the parallel signal path, expansion to even higher data rates is accommodated with each. Applications of the PRX would include gigabit satellite channels, multiple spacecraft, optical links, interactive cable-TV, telemedicine, code division multiple access (CDMA) communications, and others.

Sadr, Ramin↗

A Tunable, Software-based DRAM Error Detection and Correction Library for HPC

Proposed exascale systems will present a number of considerable resiliency challenges. In particular, DRAM soft-errors, or bit-flips, are expected to greatly increase due to the increased memory density of these systems. Current hardware-based fault-tolerance methods will be unsuitable for addressing the expected soft error frequency rate. As a result, additional software will be needed to address this challenge. In this paper we introduce LIBSDC, a tunable, transparent silent data corruption detection and correction library for HPC applications. LIBSDC provides comprehensive SDC protection for program memory by implementing on-demand page integrity verification. Experimental benchmarks with Mantevo HPCCG show that once tuned, LIBSDC is able to achieve SDC protection with 50\% overhead of resources, less than the 100\% needed for double modular redundancy.

99 GENERAL AND MISCELLANEOUS↗

DISCOVERY OF AN X-RAY-EMITTING CONTACT BINARY SYSTEM 2MASS J11201034−2201340

We report the detection of orbital modulation, a model solution, and the X-ray properties of a newly discovered contact binary, Two Micron All Sky Survey (2MASS) J11201034−2201340. We serendipitously found this X-ray point source outside the error ellipse when searching for possible X-ray counterparts of γ-ray millisecond pulsars among the unidentified objects detected by the Fermi Gamma-ray Space Telescope. The optical counterpart of the X-ray source (unrelated to the γ-ray source) was then identified using archival databases. The long-term Catalina Real-Time Transient Survey detected a precise signal with a period of P=0.28876208(56) days. A follow-up observation made by the Super Light Telescope of Lulin Observatory revealed the binary nature of the object. Utilizing archived photometric data of multi-band surveys, we construct the spectral energy distribution (SED), which is well fit by a K2V spectral template. The fitting result of the orbital profile using the Wilson–Devinney code suggests that 2MASS J11201034-2201340 is a short-period A-type contact binary and the more massive component has a cool spot. The X-ray emission was first noted in observations made by Swift, and then further confirmed and characterized by an XMM-Newton observation. The X-ray spectrum can be described by a power law or thermal Bremsstrahlung. Unfortunately, we could not observe significant X-ray orbital modulation. Finally, according to the SED, this system is estimated to be 690 pc from Earth with a calculated X-ray intensity of (0.7−1.5)×10{sup 30} erg s{sup −1}, which is in the expected range of an X-ray emitting contact binary.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Formation Optical Communication and Estimation System

An architecture has been designed that integrates formation estimation methodologies, precision formation sensing, and high-bandwidth formation communication into a robust, strap-on system that meets knowledge and communication requirements for the majority of planned, precision formation missions. Specifically, the integrated system supports (a) sub-millimeter metrology, (b) multiple greater than 10 Mbps communication channels over a large, 10 deg field-of-view (FOV), and (c) generalized formation estimation methodologies. The sensing sub-system consists of several absolute, metrology gauges with up to 0.1 mm precision that use amplitude-modulated lasers and a LISA-heritage phase meter. Since amplitude modulation is used, inexpensive and robust diode lasers may be used instead of complex, frequency-stabilized lasers such as for nanometer-level metrology. The metrology subsystem laser transceivers consist of a laser diode, collecting optics, and an avalanche photo diode (APD) for detecting incoming laser signals. The APD is necessary since received power is small due to the large (for optical applications) FOV. The phase meter determines the phase of the incoming amplitude modulations as measured by the APD. This phase is equivalent to time-of-flight and, therefore, distance. By placing three laser transceivers on each spacecraft, 18 clock-offset-corrupted distances are calculated. These measurements are communicated and averaged to obtain nine correct distances between the transceivers. From these correct distances, the range and bearing between spacecraft and their relative attitude are determined. Next, communication is integrated on the laser carrier through spectral separation. Metrology amplitude modulations are limited to the 45-50 MHz band, leaving 0-45 MHz for communication. Through careful design of coding scheme, error correction, and filters, six independent 10 Mbps receive channels are possible. Hence, a spacecraft can simultaneously broadcast at 10 Mbps and listen to six other spacecraft. The integrated sensing and communication architecture has been developed, as have formation estimation methodologies that allow the sensing topology to reconfigure as spacecraft maneuver. A bench-top implementation of the integrated sensing and communication architecture is in progress. The final, multiple sensing/communication systems will be tied together via formation estimation algorithms that are also undergoing further development.

Scharf, Daniel↗

MO-FG-202-01: A Fast Yet Sensitive EPID-Based Real-Time Treatment Verification System

Purpose: To create a real-time EPID-based treatment verification system which robustly detects treatment delivery and patient attenuation variations. Methods: Treatment plan DICOM files sent to the record-and-verify system are captured and utilized to predict EPID images for each planned control point using a modified GPU-based digitally reconstructed radiograph algorithm which accounts for the patient attenuation, source energy fluence, source size effects, and MLC attenuation. The DICOM and predicted images are utilized by our C++ treatment verification software which compares EPID acquired 1024×768 resolution frames acquired at ∼8.5hz from Varian Truebeam™ system. To maximize detection sensitivity, image comparisons determine (1) if radiation exists outside of the desired treatment field; (2) if radiation is lacking inside the treatment field; (3) if translations, rotations, and magnifications of the image are within tolerance. Acquisition was tested with known test fields and prior patient fields. Error detection was tested in real-time and utilizing images acquired during treatment with another system. Results: The computational time of the prediction algorithms, for a patient plan with 350 control points and 60×60×42cm^3 CT volume, is 2–3minutes on CPU and <27 seconds on GPU for 1024×768 images. The verification software requires a maximum of ∼9ms and ∼19ms for 512×384 and 1024×768 resolution images, respectively, to perform image analysis and dosimetric validations. Typical variations in geometric parameters between reference and the measured images are 0.32°for gantry rotation, 1.006 for scaling factor, and 0.67mm for translation. For excess out-of-field/missing in-field fluence, with masks extending 1mm (at isocenter) from the detected aperture edge, the average total in-field area missing EPID fluence was 1.5mm2 the out-of-field excess EPID fluence was 8mm^2, both below error tolerances. Conclusion: A real-time verification software, with EPID images prediction algorithm, was developed. The system is capable of performing verifications between frames acquisitions and identifying source(s) of any out-of-tolerance variations. This work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Support for Debugging Automatically Parallelized Programs

We describe a system that simplifies the process of debugging programs produced by computer-aided parallelization tools. The system uses relative debugging techniques to compare serial and parallel executions in order to show where the computations begin to differ. If the original serial code is correct, errors due to parallelization will be isolated by the comparison. One of the primary goals of the system is to minimize the effort required of the user. To that end, the debugging system uses information produced by the parallelization tool to drive the comparison process. In particular the debugging system relies on the parallelization tool to provide information about where variables may have been modified and how arrays are distributed across multiple processes. User effort is also reduced through the use of dynamic instrumentation. This allows us to modify the program execution without changing the way the user builds the executable. The use of dynamic instrumentation also permits us to compare the executions in a fine-grained fashion and only involve the debugger when a difference has been detected. This reduces the overhead of executing instrumentation.

Jost, Gabriele↗

Relative Debugging of Automatically Parallelized Programs

We describe a system that simplifies the process of debugging programs produced by computer-aided parallelization tools. The system uses relative debugging techniques to compare serial and parallel executions in order to show where the computations begin to differ. If the original serial code is correct, errors due to parallelization will be isolated by the comparison. One of the primary goals of the system is to minimize the effort required of the user. To that end, the debugging system uses information produced by the parallelization tool to drive the comparison process. In particular, the debugging system relies on the parallelization tool to provide information about where variables may have been modified and how arrays are distributed across multiple processes. User effort is also reduced through the use of dynamic instrumentation. This allows us to modify, the program execution with out changing the way the user builds the executable. The use of dynamic instrumentation also permits us to compare the executions in a fine-grained fashion and only involve the debugger when a difference has been detected. This reduces the overhead of executing instrumentation.

Jost, Gabriele↗

WOBBLE: A Proposed Mission to Characterize Past and Present Water on Mars

WOBBLE ("Water Observations from a Balloon Borne Light Explorer") is a mission concept study for a small robotic probe to explore Mars and to accomplish a scientific mission compatible with the goals of the NASA Code S enterprise. The detection of past or present water is a crucial goal for Mars exploration, representing a cross-cutting science theme relevant to past or extant life, climate history, sample return missions and eventual human exploration. The WOBBLE mission concept was developed to study evidence of water using in-situ detection methods. The features on Mars most suited to this investigation are the gullies identified by Malin and Edgett as evidence for recent, near-surface runoff of liquid water. These features are typically located on the inside face of crater rims, where the local slope angle is at or near the angle of repose. This makes the terrain difficult or impossible to access with conventional wheeled rover technology. Combined with the small size of the gullies in relation to a standard landing error ellipse, scientific investigation of these features requires a new approach to surface mobility. WOBBLE uses a low-altitude balloon-borne platform to traverse the surface from the landing site, to the investigation site, and then rise up the slope to investigate the regions of interest at close range. Of the mobility technologies available for near-term Mars exploration, only a balloon platform is capable of a well targeted, detailed sampling of the gully regions over periods of days or more. The science approach embodied in WOBBLE is two-pronged, designed to investigate both the historical evidence of liquid water utilizing high-resolution geomorphology and the characterization of mineral deposits, and present subsurface liquid water using radar sounding techniques. The WOBBLE balloon is a high-pressure hydrogen gas design, 24 meters in diameter and lifting a total payload of 130 kg, including a high-resolution camera/IR imager, Raman spectrometer, and a ground penetrating radar (GPR) sounder. The stowed balloon and payload are designed to fit within the current airbag delivery system being built for the Mars Exploration Rovers. Characterization of local meteorological conditions and wind is made over the initial sols following landing and before balloon inflation. Following balloon inflation and launch, a controlled, targeted approach toward the identified regions of interest is made in a series of several low-altitude "hops," with the balloon tethered to the ground between the hop intervals. A "snake" system is used to control the altitude to a few tens of meters above the local ground level. Enroute to the target gully, GPR soundings and Raman spectroscopy measurements study past or present water, while continued camera bearings and meteorological measurements refine the next "hop" trajectory. Once at the gully/outflow region, GPR and Raman soundings continue while the camera obtains detailed, approx. 0.5 cm images for geomorphology studies. The WOBBLE concept is applicable to Mars Scout, Mars Surveyor, or Discovery class missions.

Udrea, Bogdan↗

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

The Next Generation Safeguard Initiative (NGSI) of the U.S Department of Energy is supporting a multi-lab/university collaboration to quantify the plutonium (Pu) mass in spent nuclear fuel (SNF) assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. The following 14 NDA techniques are being studied: Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Lead Slowing Down Spectrometer, Neutron Multiplicity, Passive Neutron Albedo Reactivity, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Gamma, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Self-integration Neutron Resonance Densitometry, and Neutron Resonance Transmission Analysis. Understanding and maturity of the techniques vary greatly, ranging from decades old, well-understood methods to new approaches. Nuclear Resonance Fluorescence (NRF) is a technique that had not previously been studied for SNF assay or similar applications. Since NRF generates isotope-specific signals, the promise and appeal of the technique lies in its potential to directly measure the amount of a specific isotope in an SNF assay target. The objectives of this study were to design and model suitable NRF measurement methods, to quantify capabilities and corresponding instrumentation requirements, and to evaluate prospects and the potential of NRF for SNF assay. The main challenge of the technique is to achieve the sensitivity and precision, i.e., to accumulate sufficient counting statistics, required for quantifying the mass of Pu isotopes in SNF assemblies. Systematic errors, considered a lesser problem for a direct measurement and only briefly discussed in this report, need to be evaluated for specific instrument designs in the future. Also, since the technical capability of using NRF to measure Pu in SNF has not been established, this report does not directly address issues such as cost, size, development time, nor concerns related to the use of Pu in measurement systems. This report discusses basic NRF measurement concepts, i.e., backscatter and transmission methods, and photon source and {gamma}-ray detector options in Section 2. An analytical model for calculating NRF signal strengths is presented in Section 3 together with enhancements to the MCNPX code and descriptions of modeling techniques that were drawn upon in the following sections. Making extensive use of the model and MCNPX simulations, the capabilities of the backscatter and transmission methods based on bremsstrahlung or quasi-monoenergetic photon sources were analyzed as described in Sections 4 and 5. A recent transmission experiment is reported on in Appendix A. While this experiment was not directly part of this project, its results provide an important reference point for our analytical estimates and MCNPX simulations. Used fuel radioactivity calculations, the enhancements to the MCNPX code, and details of the MCNPX simulations are documented in the other appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complementary code and digital filtering for detection of weak VHF radar signals from the mesoscale

The SOUSY-VHF-Radar operates at a frequency of 53.5 MHz in a valley in the Harz mountains, Germany, 90 km from Hanover. The radar controller, which is programmed by a 16-bit computer holds 1024 program steps in core and controls, via 8 channels, the whole radar system: in particular the master oscillator, the transmitter, the transmit-receive-switch, the receiver, the analog to digital converter, and the hardware adder. The high-sensitivity receiver has a dynamic range of 70 dB and a video bandwidth of 1 MHz. Phase coding schemes are applied, in particular for investigations at mesospheric heights, in order to carry out measurements with the maximum duty cycle and the maximum height resolution. The computer takes the data from the adder to store it in magnetic tape or disc. The radar controller is programmed by the computer using simple FORTRAN IV statements. After the program has been loaded and the computer has started the radar controller, it runs automatically, stopping at the program end. In case of errors or failures occurring during the radar operation, the radar controller is shut off caused either by a safety circuit or by a power failure circuit or by a parity check system.

Schmidt, G.↗