Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Corrections to the elastic p ↑ p ↑ analyzing power parameterization at high energies

The HJET polarimeter was designed to measure the absolute polarization of the proton beams at RHIC. It can also be used for the precise measurement of the elastic pp single and double spin analyzing powers. Recently Boris Kopeliovich pointed out that analyzing power parametrization,which is conventionally used for these measurements, was derived with specific simplifications and for the experimental accuracy achieved at HJET, the corrections should be applied. In this not ewe evaluate the corrections to analyzing powers due to (i) the differences between electromagnetic and hadronic form factors, and (ii) the ~$m$ $^{2}_{p}$/s term in elastic pp electromagnetic amplitude. The corresponding variations of the measured hadronic spin-flip amplitudes are about experimental uncertainties of the HJET measurements. It should also be noted that the evaluated corrections might be essential for the elastic pp forward real-to-imaginary amplitude ratios ρ listed in PDG.

43 PARTICLE ACCELERATORS↗

Regenerative Feedback Resonant Circuit to Detect Transient Changes in Electromagnetic Properties of Semi-Insulating Materials

A prototype regenerative feedback resonant circuit has been developed for measuring the transient spectral response due to perturbations in properties of various electromagnetic materials. The circuit can accommodate a variety of cavity resonators, shown here in the 8 GHz range, with passive quality factors (Qstat) as high as 7,000 depending upon material loading. The positive feedback enhanced dynamic quality factors (Qdyn) of resonator/material combinations in the regenerative circuit are on the order of 107 - 108. The theory, design, and implementation of the circuit is discussed along with real-time monitored example measurements of effects due to photon-induced charge carriers in high-resistivity silicon wafers and magnetic-field induced perturbations of yttrium-iron garnet.

cavity perturbation↗

Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ARCADE 2 MEASUREMENT OF THE ABSOLUTE SKY BRIGHTNESS AT 3-90 GHz

The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an in situ reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the cosmic microwave background (CMB) temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an excess radio rise of 54 {+-} 6 mK at 3.3 GHz in addition to a CMB temperature of 2.731 {+-} 0.004 K. Combining the ARCADE 2 data with data from the literature shows an excess power-law spectrum of T = 24.1 {+-} 2.1 (K) ({nu}/{nu}{sub 0}){sup -2.599{+-}0.036} from 22 MHz to 10 GHz ({nu}{sub 0} = 310 MHz) in addition to a CMB temperature of 2.725 {+-} 0.001 K.

79 ASTRONOMY AND ASTROPHYSICS↗

Basin and Range Investigation for Developing Geothermal Energy: Exploration Data

This data package includes exploration material from the Basin & Range Investigation for Developing Geothermal Energy [in Hidden Systems] project (BRIDGE), which is part of a broader initiative to advance the exploration of hidden geothermal resources in the Basin & Range Province of the western U.S. Data modalities include a helicopter-borne time-domain electromagnetic survey, magnetotellurics, 2-meter temperature measurements, ground-based gravity and legacy aeromagnetic surveys, geochemistry, geologic mapping, LiDAR analysis, 3D models, associated geospatial data, and a bibliography of existing data and references utilized in prospect characterization and conceptual modeling. Key files are in CSV, Geosoft, and Geotools formats. Please refer to READMEs for dataset-specific information. Where applicable, acquisition data and inversion models for a particular prospect or area of interest are organized separately. This BRIDGE data package is the product of a collaboration led by Sandia National Laboratories with partners from Geologica Geothermal Group, Inc., the U.S. Navy Geothermal Program Office, and consultants Steven Sewell (Australis Geoscience Ltd) and William Cumming (Cumming Geoscience). The project's areas of interest (AOIs) are based off priority areas of interest in the southwestern portion of the Nevada Play Fairway map, distribution across tectonic provinces, accessibility, and the project team's extensive experience in the region. AOIs cover about a dozen basins that include unexplored prospects, partially explored prospects, and some developed analogue resources that provide validation cases. Many unexplored and partially explored prospects are on U.S. Department of Defense (DoD) land, though adjacent lands are included as well.

15 GEOTHERMAL ENERGY↗

Performance comparison of fiber optic tips in interferrometric displacement measurement

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

Performance comparison of fiber tips in interferometric displacement mesurements

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

Energy dependence of coherent photonuclear production of J/ψ mesons in ultra-peripheral Pb-Pb collisions at $\sqrt{{\textrm{s}}_{\textrm{NN}}}$ = 5.02 TeV

The cross section for coherent photonuclear production of J/ψ is presented as a function of the electromagnetic dissociation (EMD) of Pb. The measurement is performed with the ALICE detector in ultra-peripheral Pb-Pb collisions at a centre-of-mass energy per nucleon pair of $\sqrt{{\textrm{s}}_{\textrm{NN}}}$ = 5.02 TeV. Cross sections are presented in five different J/ψ rapidity ranges within |y| < 4, with the J/ψ reconstructed via its dilepton decay channels. In some events the J/ψ is not accompanied by EMD, while other events do produce neutrons from EMD at beam rapidities either in one or the other beam direction, or in both. The cross sections in a given rapidity range and for different configurations of neutrons from EMD allow for the extraction of the energy dependence of this process in the range 17 < W γ Pb,n < 920 GeV, where W γ Pb,n is the centre-of-mass energy per nucleon of the γPb system. This range corresponds to a Bjorken-x interval spanning about three orders of magnitude: 1.1 × 10 —5 < x < 3.3 × 10 —2 . In addition to the ultra-peripheral and photonuclear cross sections, the nuclear suppression factor is obtained. These measurements point to a strong depletion of the gluon distribution in Pb nuclei over a broad, previously unexplored, energy range. These results, together with previous ALICE measurements, provide unprecedented information to probe quantum chromodynamics at high energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric Effect of Prostate Motion During Helical Tomotherapy

Purpose: To assess the dosimetric consequence of intrafraction prostate motion on helical tomotherapy plans. Methods and Materials: An electromagnetic tracking device was used to measure real-time prostate motion for 515 fractions (16 patients). Motion tracks were used to retrospectively recalculate dose distributions using a four-dimensional calculation engine. The minimum dose (D{sub min}), maximum dose (D{sub max}), and dose to 95% of the volume (D{sub 95%}) were calculated for target volumes and compared with respective values from the treatment plan. The dosimetric effect was evaluated for each fraction. For each patient, the running cumulative effect was assessed throughout the course of treatment. Calculations were repeated assuming a time delay between initial patient setup and start of treatment. Results: Averaged over all fractions, the mean change in target D{sub 95%} was <1% (SD, 3-4%). Reductions in target D{sub 95%} of up to 20% were seen in individual fractions. Changes in prostate D{sub 95%} were similar in frequency and magnitude to D{sub 95%} changes in the planning target volume. The cumulative effect on target D{sub 95%} was approximately 1% (SD, 1%). The average cumulative effect after five fractions was 1% (SD, 1.5%). Conclusions: In general, the dosimetric effect of observed prostate motion on target D{sub 95%}was small. Infrequently severe D{sub 95%} degradations were observed for individual fractions, but their effect on the cumulative dose distribution was quickly reduced with minimal fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EIT Based Gas Detector Design by Using Michelson Interferometer

Electromagnetically induced transparency (EIT) is one of the interesting phenomena of light-matter interaction which modifies matter properties for propagation of light. In other words, we can change the absorption and refractive index (RI) in neighborhood of the resonant frequency using EIT. In this paper, we have doped 3-level quantum dots in one of the Michelson Interferometer's mirror and used EIT to change its RI. So, a controllable phase difference between lights in two arms of interferometer is created. Long response time is the main drawback of Michelson interferometer based sensor, which is resolved by this technique.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Betatron radiation from a beam driven plasma source

Photons produced by the betatron oscillation of electrons in a beam-driven plasma wake provide a uniquely intense and high-energy source of hard X-rays and gamma rays. This betatron radiation is interesting not only for its high intensity and spectral characteristics, but also because it can be used as a diagnostic for beam matching into the plasma, which is critical for maximizing the energy extraction efficiency of a plasma accelerator stage. At SLAC, gamma ray detection devices have been installed at the dump area of the FACET beamline where the betatron radiation from the plasma source used in the E200 plasma wakefield acceleration experiment may be observed. The ultra-dense, high-energy beam at FACET (2 Multiplication-Sign 10{sup 10} electrons, 20 Multiplication-Sign 20{mu}m{sup 2} spot, 20 - 100{mu}m length, 20GeV energy) when sent into a plasma source with a nominal density of {approx} 1 Multiplication-Sign 10{sup 17} cm{sup -3} will generate synchrotron-like spectra with critical energies well into the tens of MeV. The intensity of the radiation can be increased by introducing a radial offset to the centroid of the witness bunch, which may be achieved at FACET through the use of a transverse deflecting RF cavity. The E200 gamma ray detector has two main components: a 30 Multiplication-Sign 35cm{sup 2} phosphorescent screen for observing the transverse extent of the radiation, and a sampling electromagnetic calorimeter outfitted with photodiodes for measuring the on-axis spectrum. To estimate the spectrum, the observed intensity patterns across the calorimeter are fit with a Gaussian-integrated synchrotron spectrum and compared to simulations. Results and observations from the first FACET user run (April-June 2012) are presented.

43 PARTICLE ACCELERATORS↗

Random numbers from vacuum fluctuations

We implement a quantum random number generator based on a balanced homodyne measurement of vacuum fluctuations of the electromagnetic field. The digitized signal is directly processed with a fast randomness extraction scheme based on a linear feedback shift register. The random bit stream is continuously read in a computer at a rate of about 480 Mbit/s and passes an extended test suite for random numbers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AMiBA WIDEBAND ANALOG CORRELATOR

A wideband analog correlator has been constructed for the Yuan-Tseh Lee Array for Microwave Background Anisotropy. Lag correlators using analog multipliers provide large bandwidth and moderate frequency resolution. Broadband intermediate frequency distribution, back-end signal processing, and control are described. Operating conditions for optimum sensitivity and linearity are discussed. From observations, a large effective bandwidth of around 10 GHz has been shown to provide sufficient sensitivity for detecting cosmic microwave background variations.

79 ASTRONOMY AND ASTROPHYSICS↗

TWO EFFICIENT, NEW TECHNIQUES FOR DETECTING DISPERSED RADIO PULSES WITH INTERFEROMETERS: THE CHIRPOLATOR AND THE CHIMAGEATOR

Searching for dispersed radio pulses in interferometric data is of great scientific interest, but poses a formidable computational burden. Here, we present two efficient, new antenna-coherent solutions: The Chirpolator and The Chimageator. We describe the equations governing both techniques and propose a number of novel optimizations. We compare the implementation costs of our techniques with classical methods using three criteria: the operation rates (1) before and (2) after the integrate-and-dump stage, and (3) the data rate directly after the integrate-and-dump stage. When compared with classical methods, our techniques excel in the regime of sparse arrays, where they both require substantially lower data rates, and The Chirpolator requires a much lower post-integrator operation rate. In general, our techniques require more pre-integrator operations than the classical ones. We argue that the data and operation rates required by our techniques are better matched to future supercomputer architectures, where the arithmetic capability is outstripping the bandwidth capability. Our techniques are, therefore, viable candidates for deploying on future interferometers such as the Square Kilometer Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Edge turbulence and divertor heat flux width simulations of Alcator C-Mod discharges using an electromagnetic two-fluid model

The BOUT++ code has been utilized in order to improve the understanding of the role of turbulent modes in controlling edge transport and resulting scaling of the scrape-off layer (SOL) heat flux width. For the C-Mod enhanced D α (EDA) H-mode discharges, BOUT++ six-field two-fluid nonlinear simulations show a reasonable agree- ment of upstream turbulence and divertor target heat flux behavior: a) The simulated quasi-coherent modes (QCMs) show consistent characteristics of the frequency versus poloidal wave number spectra of the electromagnetic fluctuations when compared with experimental measurements: frequencies are around 60-120 kHz (experiment: about 70-110 kHz), k θ are around 2.0 cm ₋1 which is similar to the Phase Contrast Imaging data; b) Linear spectrum analysis is consistent with the nonlinear phase relationship cal- culation which indicates the dominance of resistive-ballooning modes and drift-Alfven wave instabilities; c) The SOL heat flux width λ q vs current I p scaling is reproduced by turbulent transport: the simulations yield similar λ q to experimental measurements within a factor of 2. Yet the magnitudes of divertor heat fluxes can be varied, depending on the physics models, sources and sinks, sheath boundary conditions, or flux limiting coefficient; d) Simple estimate by the "2-point model" for λ q is consistent with simulation. Moreover, blobby turbulent spreading is confirmed for these relatively high B p shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduction in Nuclear Size and Quadrupole Deformation of High-Spin Isomers of 127,129 In

We employed laser spectroscopy of atomic transitions to measure the nuclear charge radii and electromagnetic properties of the high-spin isomeric states in neutron-rich indium isotopes (𝑍 =49) near the closed proton and neutron shells at 𝑍 = 50 and 𝑁 = 82. Our data reveal a reduction in the nuclear charge radius and intrinsic quadrupole moment when protons and neutrons are fully aligned in 129 In ⁢(𝑁 = 80), to form the high spin isomer. Such a reduction is not observed in 127 In ⁢(𝑁 = 78), where more complex configurations can be formed by the existence of four neutron holes. These observations are not consistently described by nuclear theory.

high spin states↗

Entanglement measurement of the quadrature components without homodyne detection in the bright, spatially multimode far field

We present a procedure for the measurement of quadrature components of an electromagnetic field in the far field as an alternative to the traditional approach based on the homodyne detection (HD) technique. For that we suggest to use coherent sources such as phase-locked lasers or optical parametric oscillators operating above threshold. Then we show how to arrange the detection procedure in the far field that is exactly or partly equivalent to the HD. Our scheme can be applied for both the classical and nonclassical fields. The potential of the procedure is illustrated by an example which utilizes the pixellized sources of the nonclassical light. As an integral part of our investigation we develop a theory of the pixellized source of the spatiotemporally squeezed light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗