Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Effects of Gamma Ray Integrated Dose on a Commercial 65-nm SRAM Device

Here this work shows that the static random access memory (SRAM) error rate for a commercial 65-nm device in a dose rate environment can be highly dependent upon the integrated dose (dose rate × pulse duration). While the typical metric for such testing is dose rate upset (DRU) level in rad(Si)/s, a series of dose rate experiments at Little Mountain Test Facility (LMTF) shows dependence on the integrated dose. The error rate is also found to be dependent on the core voltage, and the preradiation value of the bits. We believe that these effects are explained by a well charge depletion caused by gamma ray photocurrent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

-Omics potential of in vitro skin models for radiation exposure

There is a growing need to uncover biomarkers of ionizing radiation exposure that leads to a better understanding of how exposures take place, including dose type, rate, and time since exposure. As one of the first organs to be exposed to external sources of ionizing radiation, skin is uniquely positioned in terms of model systems for radiation exposure study. The simultaneous evolution of both MS-based -omics studies, as well as in vitro 3D skin models, has created the ability to develop a far more holistic understanding of how ionizing radiation affects the many interconnected biomolecular processes that occur in human skin. However, there are a limited number of studies describing the biomolecular consequences of low-dose ionizing radiation to the skin. As a result, this review will seek to explore the current state-of-the-art technology in terms of in vitro 3D skin models, as well as track the trajectory of MS-based -omics techniques and their application to ionizing radiation research, specifically, the search for biomarkers within the low-dose range.

3D tissue model↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Evaluation of Radiolysis Data for Hydrogen Gas Generation During Gamma Irradiation of Pre-Corroded and Pristine Aluminum Samples - An Aluminum SNF Dry Storage Study Interim Report

Information and data from radiolysis testing to measure hydrogen (H₂) generated from hydrated oxides on aluminum exposed to ⁶⁰Co radiation were reviewed to evaluate hydrogen generation with radiation dose. Hydrogen generation rate is a primary input to the coupled thermal-chemical system model of the performance of aluminum-clad spent nuclear fuel in a dry storage canister (ASNF-in-canister) over its storage life. Hydrogen generation data and hydrogen generation rate (hydrogen generated per absorbed radiation dose, $\Delta$(H₂)/$\Delta$(dose)) were reported in two reports for radiolysis testing [1, 2]. The testing involved first-time data¹ for radiolytic yield of hydrogen from hydrated-oxides-on-aluminum substrates, and from pristine (non-corroded) aluminum substrates. The laboratory-grown hydrated-oxides-on-aluminum substrates contained a ~ 5 μm film consisting of the trihydroxide bayerite (Al(OH)₃) with amounts of the oxyhydroxide boehmite (AlOOH). These specimens were assumed to also contain physisorbed water (unquantified). The pristine substrates were flat coupons of aluminum that were ground to a 600-grit finish but were not immersed in water to grow a hydrated oxide. The pristine substrates were tested as companion specimens to provide information on hydrogen generation from material without chemisorbed water and were assumed to contain physisorbed water (unquantified).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reactor cell neutron dose for the molten salt breeder reactor conceptual design

The private sector’s interest in the active development of molten salt reactors has led to the need to develop and test advanced modeling and simulation tools to analyze various advanced reactor types under numerous conditions. This paper discusses the effort undertaken to model the Oak Ridge National Laboratory (ORNL) Molten Salt Breeder Reactor (MSBR) design using ORNL’s Shift Monte Carlo code. The MSBR model integrates a Monte Carlo N-Particle (MCNP) MSBR core model with an MCNP model that was generated from a CAD model of the external components and the reactor building, which was subsequently run in Shift. This paper focuses on development of the fully integrated model and its use in performing neutron transport calculations in the reactor cell area. This model is intended to aid in understanding radiological dose conditions during operation, as well as the iron dpa rates in the reactor vessel. The neutron biological dose rates and flux calculated in the reactor cell are much higher in the MSBR than in typical light-water reactors. The implications of these results and future work are also discussed in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hanford Site Composite Analysis: Dose Sensitivity Analyses

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of five analyses that evaluate parameter changes to the revised Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau). Specifically, this ECF describes the impact on total dose and analyte-specific doses for five sensitivity cases where changes to the following exposure-related parameters were implemented – (1) inventory, (2) recharge rate, (3) external dose conversion factors (DCFs) based on Federal Guidance Report (FGR) No. 15 in (EPA-402-R-19-002, Federal Guidance Report No. 15, External Exposure to Radionuclides in Air, Water, and Soil) instead of FGR No. 12 (EPA 402-R-93-081, Federal Guidance Report No. 12, External Exposure to Radionuclides in Air, Water, and Soil) for groundwater pathway scenario; (4) use of mean instead of 95th percentile intake assumptions for groundwater pathway scenario; and (5) consideration of limited sources based on U.S. Department of Energy (DOE) owned waste sites regulated under DOE O 435.1, Radioactive Waste Management. It should be noted that dose assessments for both base and sensitivity cases are based on the all-pathways representative person groundwater exposure scenario presented in DOE/RL-2022-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau.

54 ENVIRONMENTAL SCIENCES↗

Moon, Mars and Minds: Evaluating Parkinson’s disease mortality among U.S. radiation workers and veterans in the million person study of low-dose effects

Background: Radiation is one of the most important stressors related to missions in space beyond Earth’s orbit. Epidemiologic studies of exposed workers have reported elevated rates of Parkinson’s disease. The importance of cognitive dysfunction related to low-dose rate radiation in humans is not defined. A meta-analysis was conducted of six cohorts in the Million Person Study (MPS) of low-dose health effects to learn whether there is consistent evidence that Parkinson’s disease is associated with radiation dose to brain. Materials and methods: The MPS evaluates all causes of death among U.S. radiation workers and veterans, including Parkinson’s disease. Systematic and consistent methods are applied to study all categories of workers including medical radiation workers, industrial radiographers, nuclear power plant workers, atomic veterans, and Manhattan Projects workers at the Los Alamos National Laboratory and at Rocky Flats. Consistent methods for all cohorts are used to estimate organ-specific doses and to obtain vital status and cause of death. Results: The meta-analysis include 6 cohorts within the MPS, consisting of 517,608 workers and 17,219,001 person-years of observation. The mean dose to brain ranged from 6.9 to 47.6 mGy and the maximum dose from 0.76 to 2.7 Gy. Five of the 6 cohorts revealed positive associations with Parkinson’s disease. The overall summary estimate from the meta-analysis was statistically significant based on 1573 deaths due to Parkinson’s disease. The summary excess relative risk at 100 mGy was 0.17 (95% CI: 0.05; 0.29). Conclusions: Parkinson’s disease was positively associated with radiation in the MPS cohorts indicating the need for careful evaluation as to causality in other studies, delineation of possible mechanisms, and assessing possible implications for space travel as well as radiation protection guidance for terrestrial workers.

60 APPLIED LIFE SCIENCES↗

Exposure to an environmental mixture of polycyclic aromatic hydrocarbons induces hepatic cytochrome P450 enzymes in mice

Cytochrome P450 enzymes (CYPs) play an important role in bioactivating or detoxifying polycyclic aromatic hydrocarbons (PAHs), common environmental contaminants. While it is widely accepted that exposure to PAHs induces CYPs, effectively increasing rates of xenobiotic metabolism, dose- and time-response patterns of CYP induction are not well known. In order to better understand dose- and time-response relationships of individual CYPs following induction, we exposed B6129SF1/J mice to single or repeated doses (2-180 µmol/kg/d) of benzo[a]pyrene (BaP) or Supermix-10, a mixture of the top 10 most abundant PAHs found at the Portland Harbor Superfund Site. In hepatic microsomes from exposed mice, we measured amounts of active CYPs using activity-based protein profiling and total CYP expression using global proteomics. We observed rapid Cyp1a1 induction after 6 hr at the lowest PAH exposures and broad induction of many CYPs after 3 daily PAH doses at 72 hr following the first dose. Using samples displaying Cyp1a1 induction, we observed significantly higher metabolic affinity for BaP metabolism (Km reduced 3-fold), 3-fold higher intrinsic clearance, but no changes to the Vmax. Mice dosed with the highest PAH exposures exhibited 1.7 to 5-fold higher intrinsic clearance rates for BaP compared to controls and higher Vmax values indicating greater amounts of enzymes capable of metabolizing BaP. This study demonstrates exposure to PAHs found at Superfund Sites induces enzymes in dose- and time-dependent patterns in mice. Accounting for specific changes in enzyme profiles, and relative rates of PAH bioactivation and detoxification, and resulting risk will help translate internal dosimetry of animal models to humans and improve risk assessments of PAHs at Superfund sites.

Stoddard, Ethan G.↗

The impact of sampling scale: A comparison of methods for estimating external contaminant exposure in free-ranging wildlife

The impacts of contaminants on wildlife are dose dependent, and thus being able to track or predict exposure following contamination events is important for monitoring ecosystem health. However, the ability to track exposure in free-ranging wildlife is often severely limited. Consequently, researchers have predominantly relied on simple methods for estimating contaminant exposures in wildlife with little regard for spatial contaminant heterogeneity or an animal’s use of diverse habitats. We evaluated the influence sampling scale (i.e., how finely contaminant distribution and organism’s spatial use of the landscape is mapped) has on (1) realism and (2) conservativeness of exposure estimates. To do this, we monitored the actual exposure of wild boar (Sus scrofa) in Fukushima, Japan to radioactive contamination using GPS27 coupled contaminant monitors placed on individual animals. We compared empirical exposures to estimates generated by combining varying amounts of information about an individual boar’s location and/or movement, with the distribution of contamination on the landscape. Here we found that the most realistic exposure estimates were produced when finer-scale contaminant distribution surveys (e.g., airborne surveys) were combined with more accurate estimates of an individual’s space use (e.g., home ranges or core areas). Importantly, estimates of exposure based on single point surveys at a trap site (a simple method commonly used in the literature), did not correlate with actual exposure rates, suggesting dose-effects studies using this method may result in spurious conclusions. These results suggest that researchers seeking realistic estimates of exposure, such as in dose-effect studies, should ensure they have adequately accounted for fine-scale contaminant distribution patterns and areas of higher use by study organisms. However, conservative estimates of exposure i.e., intentionally over-predicting exposure as is done in initial tiers of ecological risk analyses) were not as scale sensitive and could be achieved with a single known location and coarse contaminant distribution maps.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Ligand Desorption and Fragmentation in Oleate-Capped CdSe Nanocrystals under High-Intensity Photoexcitation

Semiconductor nanocrystals (NCs) offer prospective use as active optical elements in photovoltaics, light-emitting diodes, lasers, and photocatalysts due to their tunable optical absorption and emission properties, high stability, and scalable solution processing, as well as compatibility with additive manufacturing routes. Over the course of experiments, during device fabrication, or while in use commercially, these materials are often subjected to intense or prolonged electronic excitation and high carrier densities. The influence of such conditions on ligand integrity and binding remains underexplored. Here, in this study, we expose CdSe NCs to laser excitation and monitor changes in oleate that is covalently attached to the NC surface using nuclear magnetic resonance as a function of time and laser intensity. Higher photon doses cause increased rates of ligand loss from the particles, with upward of 50% total ligand desorption measured for the longest, most intense excitation. Surprisingly, for a range of excitation intensities, fragmentation of the oleate is detected and occurs concomitantly with formation of aldehydes, terminal alkenes, H 2 , and water. After illumination, NC size, shape, and bandgap remain constant although low-energy absorption features (Urbach tails) develop in some samples, indicating formation of substantial trap states. The observed reaction chemistry, which here occurs with low photon to chemical conversion efficiency, suggests that ligand reactivity may require examination for improved NC dispersion stability but can also be manipulated to yield desired photocatalytically accessed chemical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a FELIX based readout system for ITk strip hybrid module demonstrator for ATLAS Phase-II Upgrade

The Large Hadron Collider (LHC) will undergo a major upgrade around 2024 with a roughly tenfold increase in luminosity. It results in corresponding increases in particle rates and radiation doses that the current ATLAS Inner Tracking Detector cannot cope with. Therefore the ATLAS experiment will build a new all-silicon tracking system called the ITk (Inner Tracker) that includes an inside pixel detector close to the beam line and a strip detector in outside layer. Meanwhile the ATLAS experiment will adopt the Front-End Link eXchange (FELIX) system as the interface between the data acquisition and front-end electronics for all sub-detectors in the Phase II Upgrade. In this contribution, we present a prototype of FELIX based readout system for the strip hybrid module. Its hardware, firmware and software GUI application will be discussed, as well as integration test results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oxidation Behavior of Irradiated and Unirradiated NBG-25 Graphite

This presentation discusses The xxidation behavior of irradiated and unirradiated NBG-25 Graphite results of thermogravimetric analysis of same-source specimens from the AGC-1 experiement. Minimal annealing effects, Substantial increase in OR with Irradiation using Conventional Rate Analysis, Apparent Dose Dependency, Examination of Onset (Alternate Analysis) Shows Competing Irradiation Effects, and Similar Test Matrix (without annealing) now under way with NBG-18 Graphite is reviewed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation damage and dose limits in serial synchrotron crystallography at cryo- and room temperatures

Radiation damage limits the accuracy of macromolecular structures in X-ray crystallography. Cryogenic (cryo-) cooling reduces the global radiation damage rate and, therefore, became the method of choice over the past decades. The recent advent of serial crystallography, which spreads the absorbed energy over many crystals, thereby reducing damage, has rendered room temperature (RT) data collection more practical and also extendable to microcrystals, both enabling and requiring the study of specific and global radiation damage at RT. Here, we performed sequential serial raster-scanning crystallography using a microfocused synchrotron beam that allowed for the collection of two series of 40 and 90 full datasets at 2- and 1.9-Å resolution at a dose rate of 40.3 MGy/s on hen egg white lysozyme (HEWL) crystals at RT and cryotemperature, respectively. The diffraction intensity halved its initial value at average doses ( D 1/2 ) of 0.57 and 15.3 MGy at RT and 100 K, respectively. Specific radiation damage at RT was observed at disulfide bonds but not at acidic residues, increasing and then apparently reversing, a peculiar behavior that can be modeled by accounting for differential diffraction intensity decay due to the nonuniform illumination by the X-ray beam. Specific damage to disulfide bonds is evident early on at RT and proceeds at a fivefold higher rate than global damage. The decay modeling suggests it is advisable not to exceed a dose of 0.38 MGy per dataset in static and time-resolved synchrotron crystallography experiments at RT. This rough yardstick might change for proteins other than HEWL and at resolutions other than 2 Å.

36 MATERIALS SCIENCE↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗