Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing General Relativity in the Solar System: Present Status and Possible Future Developments

Series of recent experiments have successfully tested Einstein's general theory of relativity to a remarkable precision. Various experimental techniques were used to test relativistic gravity in the solar system namely spacecraft Doppler tracking, planetary ranging, lunar laser ranging, dedicated gravity experiments in space and many ground-based efforts. Here we review the foundations of general relativity, present recent progress in the tests of relativistic gravity, and discuss the advances in our understanding of fundamental physics that are anticipated in the near future.

79 ASTRONOMY AND ASTROPHYSICS↗

Extended fast-ion D-alpha diagnostic on DIII-D

A fast-ion deuterium-alpha (FIDA) diagnostic, first commissioned on DIII-D in 2005, relies on Doppler-shifted light from charge-exchange between beam neutrals and energetic ions. The second generation (2G) system was installed on DIII-D in 2009. Its most obvious improvement is the spatial coverage with 11 active in-beam and three passive off-beam views; the latter allows for simultaneous monitoring of the background signal. Providing extended coverage in fast-ion velocity space, the new views possess a more tangential component with respect to the toroidal field compared to their first generation counterparts. Each viewing chord consists of a bundle of three 1.5 mm core fibers to maximize light gathering. For greater throughput, fast f/1.8 optical components are used throughout. The signal is transmitted via fiber optics to a patch panel, so the user is able to choose the detector. FIDA was originally installed with a spectrometer and charge-coupled device (CCD) camera to monitor the full D{sub {alpha}} spectrum for two spatial views. 2G adds another spectrometer and CCD that monitor the blue-shifted wing for six spatial views at 1 kHz. In addition, a photomultiplier tube and fast digitizer provide wavelength-integrated signals at 1 MHz for eight spatial views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasioptical design of integrated Doppler backscattering and correlation electron cyclotron emission systems on the DIII-D tokamak

The quasioptical design of a new integrated Doppler backscattering (DBS) and correlation electron cyclotron emission (CECE) system is presented. The design provides for simultaneous measurements of intermediate wavenumber density and long wavelength electron temperature turbulence behavior. The Doppler backscattering technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field, geodesic acoustic modes, zonal flows, and intermediate scale (k{approx}1-6 cm{sup -1}) density turbulence. The correlation ECE system measures a second turbulent field, electron temperature fluctuations, and is sensitive to long poloidal wavelength (k{<=}1.8 cm{sup -1}). The integrated system utilizes a newly installed in-vessel focusing mirror that produces a beam waist diameter of 3.5-5 cm in the plasma depending on the frequency. A single antenna (i.e., monostatic operation) is used for both launch and receive. The DBS wavenumber is selected via an adjustable launch angle and variable probing frequency. Due to the unique system design both positive and negative wavenumbers can be obtained, with a range of low to intermediate wavenumbers possible (approximately -3 to 10 cm{sup -1}). A unique feature of the design is the ability to place the DBS and CECE measurements at the same radial and poloidal locations allowing for cross correlation studies (e.g., measurement of nT cross-phase).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of laser induced fluorescence diagnostic for measuring the parameters of plasma containing rare gas species

Laser induced fluorescence (LIF) technique development activity for measurement of plasma parameters in ITER divertor plasma is described. Helium density is the task of priority, but Doppler measurement of ion (atom) temperatures is also the aim of the program. The concept of ITER scenarios includes injection of ''extrinsic'' impurities (Ne, Ar, and Kr). It is possible to use the species as tracing elements for measurement of T{sub i}, T{sub a}. The program included modeling experiments on PNX-U (a multicusp trap with microwave argon plasma). Helium was added by puffing into discharge. Temperatures T{sub i}(Ar{sup 1+}) and T{sub a}(He{sup 0}) have been measured by scanning laser line across absorption line of species. Summarizing of fluorescence signals provided input data for estimation of Ar{sup 1+} and He{sup 0} densities via interpretative collisional-radiative models. Besides, the collisional-radiative model has been used for estimation of electron density using the ratio of fluorescence signals at 388.9 and 706.5 nm helium lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poloidal beam emission spectroscopy system for the measurement of density fluctuations in Large Helical Device

A system of beam emission spectroscopy (BES) for density fluctuation measurements having the sightlines passing through the plasma in the poloidal direction was developed in the Large Helical Device (LHD). Even though the angle between the beam and the sightline is slightly larger than a right angle, Doppler-shifted beam emission can be distinguished from background emission because of the high energy (120-170 keV) of the neutral beam for heating with negative ion sources. Spatial resolution is about 0.1-0.2 in the normalized radius. Compared with the prototype BES system with toroidal sightlines, the BES system with poloidal sightlines showed improved spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-ion D{alpha} measurements of the fast-ion distribution (invited)

The fast-ion D{alpha} (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-{alpha} light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of D{alpha} light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of {approx}1 ms, {approx}10 keV, and {approx}2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of {approx}50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for ion beam driven high energy density physics experiments

Intense beams of heavy ions are capable of heating volumetric samples of matter to high energy density. Experiments are performed on the resulting warm dense matter (WDM) at the NDCX-I ion beam accelerator. The 0.3 MeV, 30 mA K{sup +} beam from NDCX-I heats foil targets by combined longitudinal and transverse neutralized drift compression of the ion beam. Both the compressed and uncompressed parts of the NDCX-I beam heat targets. The exotic state of matter (WDM) in these experiments requires specialized diagnostic techniques. We have developed a target chamber and fielded target diagnostics including a fast multichannel optical pyrometer, optical streak camera, laser Doppler-shift interferometer (Velocity Interferometer System for Any Reflector), beam transmission diagnostics, and high-speed gated cameras. We also present plans and opportunities for diagnostic development and a new target chamber for NDCX-II.

43 PARTICLE ACCELERATORS↗

Calculation of the Johann error for spherically bent x-ray imaging crystal spectrometers

New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar{sup 16+}, from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a spatially resolving x-ray crystal spectrometer for measurement of ion-temperature (T{sub i}) and rotation-velocity (v) profiles in ITER

Imaging x-ray crystal spectrometer (XCS) arrays are being developed as a US-ITER activity for Doppler measurement of T{sub i} and v profiles of impurities (W, Kr, and Fe) with {approx}7 cm (a/30) and 10-100 ms resolution in ITER. The imaging XCS, modeled after a prototype instrument on Alcator C-Mod, uses a spherically bent crystal and 2D x-ray detectors to achieve high spectral resolving power (E/dE>6000) horizontally and spatial imaging vertically. Two arrays will measure T{sub i} and both poloidal and toroidal rotation velocity profiles. The measurement of many spatial chords permits tomographic inversion for the inference of local parameters. The instrument design, predictions of performance, and results from C-Mod are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler coherence imaging and tomography of flows in tokamak plasmas (invited)

This article describes the results of spatial heterodyne Doppler ''coherence imaging'' of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to obtain the spatial distribution of the carbon ion parallel flow and emissivity. The operating principles of the new instruments are described, and the link between measured properties and line integrals of the flow field are established. An iterative simultaneous arithmetic reconstruction procedure is applied to invert the interferometric phase shift projections, and the reconstructed parallel flow field amplitudes are found to be in reasonable agreement with UEDGE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast ion charge exchange spectroscopy adapted for tangential viewing geometry in LHD

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contained modes in mirrors with sheared rotation

In mirrors with ExB rotation, a fixed azimuthal perturbation in the laboratory frame can appear as a wave in the rotating frame. If the rotation frequency varies with radius, the plasma-frame wave frequency will also vary radially due to the Doppler shift. A wave that propagates in the high rotation plasma region might therefore be evanescent at the plasma edge. This can lead to radially localized Alfven eigenmodes with high azimuthal mode numbers. Contained Alfven modes are found both for peaked and nonpeaked rotation profiles. These modes might be useful for alpha channeling or ion heating, as the high azimuthal wave number allows the plasma wave frequency in the rotating frame to exceed the ion cyclotron frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of precise line shape measurements to determine the vapor pressure of ice in the temperature range from 0 to -70 deg. C

We performed spectroscopic measurement of the vapor pressure of ice. We describe an experimental method that enables such a measurement over a wide temperature range that covers the change of the vapor pressure of ice by a few orders of magnitude. Our preliminary results have relative uncertainties at the sub-percent level and are compared to correlations given by Wexler [A. Wexler, J. Res. NBS 81A, 5 (1977)] and Marti and Mauersberger [J. Marti and K. Mauersberger, Geophys. Res. Lett. 20,363 (1993)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser Experiments for High Energy Density Science

High energy density science probes some of the most basic scientific questions that cut across traditional disciplines. The advent of table top, terawatt, femtosecond lasers promises to revolutionize this area by the use of precise experimental techniques on the one hand and testing of models and computer simulations on the other. In this paper, we present some of our results on hot electron generation, giant magnetic fields and ultrafast plasma dynamics using such experiments and theoretical modeling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Transient And Spatially Non-Homogenous Accident Analysis Of Two-Dimensional Cylindrical Nuclear Reactor

The research about fast transient and spatially non-homogenous nuclear reactor accident analysis of two-dimensional nuclear reactor has been done. This research is about prediction of reactor behavior is during accident. In the present study, space-time diffusion equation is solved by using direct methods which consider spatial factor in detail during nuclear reactor accident simulation. Set of equations that obtained from full implicit finite-difference discretization method is solved by using iterative methods ADI (Alternating Direct Implicit). The indication of accident is decreasing macroscopic absorption cross-section that results large external reactivity. The power reactor has a peak value before reactor has new balance condition. Changing of temperature reactor produce a negative Doppler feedback reactivity. The reactivity will reduce excess positive reactivity. Temperature reactor during accident is still in below fuel melting point which is in secure condition.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron Scale Solar Wind Turbulence: Cluster Observations and Theoretical Modeling

Turbulence at MagnetoHydroDynamics (MHD) scales of the solar wind has been studied for more than three decades, using data analyzes, theoretical and numerical modeling. However smaller scales have not been explored until very recently. Here, we review recent results on the first observation of cascade and dissipation of the solar wind turbulence at the electron scales. Thanks to the high resolution magnetic and electric field data of the Cluster spacecraft, we computed the spectra of turbulence up to {approx}100 Hz (in the spacecraft reference frame) and found two distinct breakpoints in the magnetic spectrum at 0.4 Hz and 35 Hz, which correspond, respectively, to the Doppler-shifted proton and electron gyroscales, f{sub {rho}p} and f{sub {rho}e}. Below f{sub {rho}p} the spectrum follows a Kolmogorov scaling f{sup -1.62}, typical of spectra observed at 1 AU. Above f{sub {rho}p} a second inertial range is formed with a scaling f{sup -2.3} down to f{sub {rho}e}. Above f{sub {rho}e} the spectrum has a steeper power law {approx}f{sup -4.1} down to the noise level of the instrument. Solving numerically the linear Maxwell-Vlasov equations combined with recent theoretical predictions of the Gyro-Kinetic theory, we show that the present results are fully consistent with a scenario of a quasi-two-dimensional cascade into Kinetic Alfven modes (KAW).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The photodissociation dynamics of tetrachloroethylene

We present a direct current slice imaging study of tetrachloroethylene (C{sub 2}Cl{sub 4}) photodissociation, probing the resulting ground state Cl ({sup 2}P{sub 3/2}) and spin-orbit excited state Cl* ({sup 2}P{sub 1/2}) products. We report photofragment images, total translational energy distributions and the product branching ratio of Cl*/Cl following dissociation at 235 and 202 nm, obtained using a two-color reduced-Doppler dissociation/probe. Near 235 nm, the Cl translational energy distribution shows a peak at the limit of the available energy, indicating a direct dissociation through a {sigma}*(C-Cl) (leftarrow){pi} (C=C) transition, which is superimposed on a broader underlying distribution. The ground state Cl image and associated translational energy distribution at 202 nm is broad and peaked at lower energy, suggesting either internal conversion to the ground state or a lower excited state prior to dissociation. The Cl* images are similarly broad at both wavelengths. The branching ratio is presented as a function of recoil energy, but after integration shows a near-statistical average of Cl:Cl* as 70:30 at both wavelengths. All the images are largely isotropic, with anisotropy parameters ({beta}) of 0.05 {+-} 0.03.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗