Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Auto-adaptive Harris corner detection algorithm based on entropy-improved block processing

Extracting well distributed control points (CPs) is a very challenging task for remote sensing image registration, particularly for large high-resolution images over heterogeneous landscape. Based on image analysis such as edge detection, corner detection, and information theory, a new CP detection approach is proposed to select high- quality, evenly distributed CPs. The Entropy-Block-Based variant of the Harris Corner Detector (EBB-HCD) is achieved by dividing the image into blocks and by allocating the number of CP's based upon the entropy of each block. While the block-based strategy improves the CP balance problem, a factor calculated from entropy avoids overdetection. We conducted a comparison study utilizing the well-known Harris Corner Detector (HCD) and an implementation of the Block-Based Harris Corner Detector (BB-HCD). Experimental results indicate that using EBB-HCD to find the CPs improves the overall alignment accuracy during registration compared with HCD or BB-HCD.

Sun, Yihang↗

PCMS: Parallel Coupler For Multimodel Simulations

This paper presents the Parallel Coupler for Multimodel Simulations (PCMS), a new GPU accelerated generalized coupling framework for coupling simulation codes on leadership class supercomputers. PCMS includes distributed control and field mapping methods for up to five dimensions. For field mapping PCMS can utilize discretization and field information to accommodate physics constraints. PCMS is demonstrated with a coupling of the gyrokinetic microturbulence code XGC with a Monte Carlo neutral transport code DEGAS2 and with a 5D distribution function coupling of an energetic particle transport code (GNET) to a gyrokinetic microturbulence code (GTC). Weak scaling is also demonstrated on up to 2,080 GPUs of Frontier with a weak scaling efficiency of 85%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs: Preprint

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Toward a Cyber Resilient and Secure Microgrid Using Software-Defined Networking

To build a resilient and secure microgrid in the face of growing cyber-attacks and cyber-mistakes, we present a software-defined networking (SDN)-based communication network architecture for microgrid operations. We leverage the global visibility, direct networking controllability, and programmability offered by SDN to investigate multiple security applications, including self-healing communication network management, real-time and uncertainty-aware communication network verification, and specification-based intrusion detection. We also expand a novel cyber-physical testing and evaluation platform that combines a power distribution system simulator (for microgrid energy services) and an SDN emulator with a distributed control environment (for microgrid communications). Experimental results demonstrate that the SDN-based communication architecture and applications can significantly enhance the resilience and security of microgrid operations against the realization of various cyber threats.

critical infrastructure protection↗

Modular thermal energy storage system

A thermal energy storage (TES) system includes a plurality of closely packed TES modules, each TES module having a shell enclosing a plurality of sealed tubes that each contain a TES media. A computer-controlled flow control system includes a flow distributor, for example a flow distributor having a plenum configured to receive a heat transfer fluid (HTF), and a plurality of control valves controlled by the computer to controllably distribute the HTF from the plenum to the plurality of TES modules. Sensor data from the TES modules, for example temperature, pressure, and/or flow data, is provided to the computer. In some embodiments the plenum includes two or more compartments with separate HTF flow ports, which may be provided to the controller at different temperatures.

Wirz, Richard E.↗

Networked Microgrid Operations: Supporting a Resilient Electric Power Infrastructure

Modern electric power systems operate using large generating units managed with a centralized control structure. The current systems are the result of over a hundred years of technological development and consolidation to leverage economies of scale. While the existing systems have proven cost effective and reliable, modern systems are experiencing a wide range of operational challenges that are causing a reexamination of the centralized control structure. Despite the nearly universal adoption of centralized control, electric power systems are fractal in their operational requirements. Specifically, the fundamental operational requirements are the same, regardless of the system size. While past technologies have not allowed for exploitation of this fractal behavior, emerging technologies are making it possible; these technologies include grid-forming inverters, modern telecommunications systems, and distributed control architectures. Here we show emerging technologies that allow the fractal operational requirements of electric power systems to be exploited as networked microgrids to increase the resiliency of the world’s critical electrical infrastructure.

Schneider, Kevin P.↗

Distributed model predictive control for coordinated, grid-interactive buildings

Continued focus on reducing carbon emissions and improving energy efficiency requires buildings to become grid-interactive and not just behave as static consumers. A distributed model predictive control (DMPC) algorithm known as Limited-Communication (LC) DMPC is modified to enable grid-interactive buildings. A grid-aggregator subsystem is added that allows for a bulk grid power reference signal to be followed while the individual building subsystems also achieve their local comfort objectives. The LC-DMPC algorithm is applied for the first time to systems with multiple buildings. Adequate power tracking is shown for different simulation scenarios involving heterogeneous buildings, and next steps are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building a Better Grid, in Partnership with the OMNETRIC Group and Siemens

In collaboration with Siemens and the National Renewable Energy Laboratory (NREL), OMNETRIC Group developed a distributed control hierarchy—based on an open field message bus (OpenFMB) framework—that allows control decisions to be made at the edge of the grid. The technology was validated and demonstrated at NREL’s Energy Systems Integration Facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digial Technology Qualification Task 2 - Suitability of Digital Alternatives to Analog Sensors and Actuators

The next generation reactors in the U.S. are an opportunity for vendors to build new reactor technology with advanced Instrumentation and Control Systems (control rooms, DCS, etc.). The advances made in the development of many current generation operating reactors in other parts of the world are being used in the design and construction of new plants. These new plants are expected to have fully integrated digital control rooms, computerized procedures, integrated surveillance testing with on-line monitoring and a major effort toward improving the O&M and fault survivability of the overall systems. In addition the designs are also incorporating major improvements in the man-machine interface based on lessons learned in nuclear and other industries. The above relates primarily to the scope of supply in instrumentation and control systems addressed by Chapter 7 of the Standard Review Plan (SRP) NUREG-0800 (Reference 9.5), and the associated Balance of Plant (BOP) I&C systems. This does not relate directly to the actuator and motor, breaker, initiation circuitry, valve position, etc. which is the subject of this report and normally outside of the traditional Distributed Control System (DCS), for both safety and non-safety systems. The recommendations presented in this report will be used as input to I&C research programming for the implementation of lessons learned during the early phases of new build both for large light water reactors (LWR) and also small modular reactors (SMR). This report is intended to support current research plans and provide user (vendor, owner-operator) input to the optimization of these research plans.

99 GENERAL AND MISCELLANEOUS↗

Detection and Analysis of Threats to the Energy Sector: DATES

This report summarizes Detection and Analysis of Threats to the Energy Sector (DATES), a project sponsored by the United States Department of Energy and performed by a team led by SRI International, with collaboration from Sandia National Laboratories, ArcSight, Inc., and Invensys Process Systems. DATES sought to advance the state of the practice in intrusion detection and situational awareness with respect to cyber attacks in energy systems. This was achieved through adaptation of detection algorithms for process systems as well as development of novel anomaly detection techniques suited for such systems into a detection suite. These detection components, together with third-party commercial security systems, were interfaced with the commercial Security Information Event Management (SIEM) solution from ArcSight. The efficacy of the integrated solution was demonstrated on two testbeds, one based on a Distributed Control System (DCS) from Invensys, and the other based on the Virtual Control System Environment (VCSE) from Sandia. These achievements advance the DOE Cybersecurity Roadmap [DOE2006] goals in the area of security monitoring. The project ran from October 2007 until March 2010, with the final six months focused on experimentation. In the validation phase, team members from SRI and Sandia coupled the two test environments and carried out a number of distributed and cross-site attacks against various points in one or both testbeds. Alert messages from the distributed, heterogeneous detection components were correlated using the ArcSight SIEM platform, providing within-site and cross-site views of the attacks. In particular, the team demonstrated detection and visualization of network zone traversal and denial-of-service attacks. These capabilities were presented to the DistribuTech Conference and Exhibition in March 2010. The project was hampered by interruption of funding due to continuing resolution issues and agreement on cost share for four months in 2008. This resulted in delays in finalizing agreements with commercial partners, and in particular the Invensys testbed was not installed until December 2008 (as opposed to the March 2008 plan). The project resulted in a number of conference presentations and publications, and was well received when presented at industry forums. In spite of some interest on the part of the utility sector, we were unfortunately not able to engage a utility for a full-scale pilot deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

RBAC Driven Least Privilege Architecture For Control Systems

The concept of role based access control (RBAC) within the IT environment has been studied by researchers and was supported by NIST (circa 1992). This earlier work highlighted the benefits of RBAC which include reduced administrative workload and policies which are easier to analyze and apply. The goals of this research were to expand the application of RBAC in the following ways. Apply RBAC to the control systems environment: The typical RBAC model within the IT environment is used to control a user’s access to files. Within the control system environment files are replaced with measurement (e.g., temperature) and control (e.g. valve) points organized as a hierarchy of control assets (e.g. a boiler, compressor, refinery unit). Control points have parameters (e.g., high alarm limit, set point, etc.) associated with them. The RBAC model is extended to support access to points and their parameters based upon roles while at the same time allowing permissions for the points to be defined at the asset level or point level directly. In addition, centralized policy administration with distributed access enforcement mechanisms was developed to support the distributed architecture of distributed control systems and SCADA; Extend the RBAC model to include access control for software and devices: The established RBAC approach is to assign users to roles. This work extends that notion by first breaking the control system down into three layers 1) users, 2) software and 3) devices. An RBAC model is then created for each of these three layers. The result is that RBAC can be used to define machine-to-machine policy enforced via the IP security (IPsec) protocol. This highlights the potential to use RBAC for machine-to-machine connectivity within the internet of things; and Enable dynamic policy based upon the operating mode of the system: The IT environment is generally static with respect to policy. However, large cyber physical systems such as industrial controls have various operating modes (start-up, normal operation, emergency, shut-down and maintenance are typical). The policy enforcement architecture must be able to support changes in access permissions as the mode of the control system changes. For example an operator’s role may not allow the operator to shut down a pump during “normal operation” but that same operator role may be given permission to shut down the pump if the refinery transitions to “emergency” mode. The effectiveness of the approach was validated by applying it to the Experion Process Knowledge System. This is a large commercial industrial control system often used to control oil refineries and other assets within the oil and gas sector. As a by-product, other industries using Experion (Pharmaceuticals, Specialty Chemicals, etc.) also benefit from increased security. Policies representative of those that would be used within an oil refinery were created and validated against the RBAC model as implemented in the underlying SQL database. The administration of policy is simplified which in turn makes it practical for security administrators to specify policies which enforce least privilege. The result is a qualitative reduction in risk. The benefits of the enhanced RBAC model are clear and as a result. Honeywell is incorporating portions of the RBAC research into the 2014 release of Experion.

97 MATHEMATICS AND COMPUTING↗

CIRCLES: Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing

The energy efficiency of today’s vehicular mobility relies on the un-integrated combination of i) control via static assets (traffic lights, metering, variable speed limits, etc.); and ii) onboard vehicle automation (adaptive cruise control (ACC), ecodriving, etc.). These two families of control were not co-designed and are not engineered to work in coordination. Recent studies have shown i) limitations of controls, and even ii) negative impacts of ACC. This project focused on the technology development, implementation and prototyping, and validation of Mobile Traffic Control (MTC). MTC can be viewed as an extension of classical traffic control (in which static infrastructure actuates traffic flow). In the MTC paradigm, automated vehicles actuate the entire flow via their behavior, offering enhanced possibilities to optimize the energy footprint of traffic, if designed correctly. We set out to demonstrate for the first time that considerably reduced fuel consumption of all vehicles in traffic can be achieved via distributed control of a small proportion of CAVs. Compared to baseline vehicular technologies, our work offers a significant design departure: control algorithms for the CAVs consider the impact one vehicle can have on overall traffic, improving resulting overall fuel consumption. We focus on using a few vehicles (as traffic controllers via CAV technology) to improve the energy efficiency of traffic flow to further optimize energy efficiency. A live-traffic demonstration in November 2022 featured the deployment of 100 specially-equipped CAVs, constituting an approximate local penetration rate upwards of 2%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous and Adaptive Voltage Control using Multiple Distributed Energy Resources

Voltage regulation using distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control has drawn increasing interests. This paper addresses the challenges of controlling multiple DEs to regulate voltages in distribution systems using an autonomous and adaptive control approach. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters with multiple DEs. Hence, the proposed control method is theoretically solid. Simulation results confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation or inefficiency. This method is autonomous based on local information and the other DEs input without the instructions from any control center, is widely adaptive to variable power system operational situations, and has a high tolerance to data shortage of systems parameter. Hence, it is suitable for broad utility application

Li, Huijuan↗

Mitigating the Effect of Wind Gusts on Local Run-of-River Hydropower Plants Using Cooperative Control

This paper focuses on the challenges and solutions associated with the integration of wind farms in a hydro- dominated power system. Due to sudden increases in wind power, the system frequency can increase, causing excessive reduction in the run-of-river (ROR) system’s power. Considering their small pondage, this can result in damage to the physical structure due to water level violations which are also penalized by stakeholders. To prevent excessive ROR power deviations, ROR governor wear and tear, and to prevent tie-line deviations, a centralized, distributed, and hybrid scheme for coordinating the response from a cluster of ROR plants is examined. Both centralized and distributed control as well as their hybrids can reduce frequency peaks. However, the inclusion of decentralized cooperative controls leads to reduced governor actions from fast- acting plants while enhancing net response from the hydro unit cluster.

13 HYDRO ENERGY↗

Packetized Energy Management: Coordinating Transmission and Distribution (Final Report)

The project Packetized Energy Management (PEM): Coordinating Transmission and Distribution was part of the ARPA-E NODES program from 2015 to 2023. The high-level goal of the project was to develop and demonstrate novel, scalable, and impactful technologies related to the coordination of networked distributed energy resources (DERs). By demonstrating responsive means by which fleets of DERs could be coordinated to enhance grid operation and reliability, the U.S. could accelerate renewable integration and electrification efforts and meet decarbonization goals.

25 ENERGY STORAGE↗

Supplemental Information for New York State Standardized Interconnection Requirements

This document is intended to aid in the understanding and application of the New York State Standardized Interconnection Requirements (SIR) and Application Process for New Distributed Generators 5 MW or Less Connected in Parallel with Utility Distribution Systems, and it aims to provide supplemental information and discussion on selected topics relevant to the SIR. This guide focuses on technical issues that have to date resulted in the majority of utility findings within the context of interconnecting photovoltaic (PV) inverters. This guide provides background on the overall issue and related mitigation measures for selected topics, including substation backfeeding, anti-islanding and considerations for monitoring and controlling distributed energy resources (DER).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decoupling Coupled Constraints Through Utility Design

Several multiagent systems exemplify the need for establishing distributed control laws that ensure the resulting agents' collective behavior satisfies a given coupled constraint. This technical note focuses on the design of such control laws through a game-theoretic framework. In particular, this technical note provides two systematic methodologies for the design of local agent objective functions that guarantee all resulting Nash equilibria optimize the system level objective while also satisfying a given coupled constraint. Furthermore, the designed local agent objective functions fit into the framework of state based potential games. Consequently, one can appeal to existing results in game-theoretic learning to derive a distributed process that guarantees the agents will reach such an equilibrium.

Li, N↗