Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the spatial resolution for imaging with fast neutrons

In this paper, we report on the realization of an improved concept for the detection of fast neutrons using a specific setup of scintillators with the aim to overcome limitations in spatial resolution. While fast neutron imaging (FNI) is a technique to investigate very thick material layers in transmission mode, currently there is a limit in the spatial resolution at ~1 mm, which hinders the performance for the detection of features like cracks, material damage or pores in large objects ($\gg$1 cm 3 ). The improved concept presented here is based on the separation of the converter material from the scintillation layer in a suitable way, which was successfully tested and referenced to the standard devices at the NECTAR facility (FRM-2, MLZ, Garching) under realistic beamline conditions. The results imply a break-through in enabling detection of structures on the order of 0.2 to 0.5 mm (a more precise estimation is not possible due to other resolution determing factors in a realistic setup). Potential additional improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions

The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.

47 OTHER INSTRUMENTATION↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Adaptive Optics Survey for Substellar Objects around Young, Nearby, Low-mass Stars with Robo-AO

We present results from the Large Adaptive optics Survey for Substellar Objects, where the goal is to directly image new substellar companions (<70 M {sub Jup}) at wide orbital separations (≳50 au) around young (≲300 Myr), nearby (<100 pc), low-mass (≈0.1–0.8 M{sub ⊙}) stars. We report on 427 young stars imaged in the visible (i') and near-infrared (J or H ) simultaneously with Robo-AO on the Kitt Peak 2.1 m telescope and later the Maunakea University of Hawaii 2.2 m telescope. To undertake the observations, we commissioned a new infrared camera for Robo-AO that uses a low-noise high-speed SAPHIRA avalanche photodiode detector. We detected 121 companion candidates around 111 stars, of which 62 companions are physically associated based on Gaia DR2 parallaxes and proper motions, another 45 require follow-up observations to confirm physical association, and 14 are background objects. The companion separations range from 2 to 1101 au and reach contrast ratios of 7.7 mag in the near-infrared compared to the primary. The majority of confirmed and pending candidates are stellar companions, with ~5 being potentially substellar and requiring follow-up observations for confirmation. We also detected a 43 ± 9 M {sub Jup} and an 81 ± 5 M {sub Jup} companion that were previously reported. We found 34 of our targets have acceleration measurements detected using Hipparcos–Gaia proper motions. Of those, 58{sub -14}{sup +12}% of the 12 stars with imaged companion candidates have significant accelerations (χ{sup 2}>11.8), while only 23{sub -6}{sup +11}% of the remaining 22 stars with no detected companion have significant accelerations. The significance of the acceleration decreases with increasing companion separation. These young accelerating low-mass stars with companions will eventually yield dynamical masses with future orbit monitoring.

47 OTHER INSTRUMENTATION↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Abridged spectral matrix inversion: parametric fitting of X-ray fluorescence spectra following integrative data reduction

Recent improvements in both X-ray detectors and readout speeds have led to a substantial increase in the volume of X-ray fluorescence data being produced at synchrotron facilities. This in turn results in increased challenges associated with processing and fitting such data, both temporally and computationally. Herein an abridging approach is described that both reduces and partially integrates X-ray fluorescence (XRF) data sets to obtain a fivefold total improvement in processing time with negligible decrease in quality of fitting. The approach is demonstrated using linear least-squares matrix inversion on XRF data with strongly overlapping fluorescent peaks. This approach is applicable to any type of linear algebra based fitting algorithm to fit spectra containing overlapping signals wherein the spectra also contain unimportant (non-characteristic) regions which add little (or no) weight to fitted values, e.g. energy regions in XRF spectra that contain little or no peak information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗