Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excited states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the muon flux produced by 10.6 GeV electrons in a beam dump

This paper proposes the results of an experiment to assess the muon flux produced by the interaction of a 10.6 GeV electron beam with the Hall-A beam dump at Jefferson Lab (JLab). The goal was to benchmark Monte Carlo simulations that are an essential tool for estimating beam-related backgrounds in beam-dump experiments aimed at searching for rare events, such as the Beam Dump eXperiment (BDX) planned at JLab. Beam-produced muons were measured with a CsI(Tl) crystal sandwiched between a set of segmented plastic scintillators placed at two different distances from the dump: 25.7 m and 28.8 m. At each location the muon flux was sampled at different vertical positions with respect to the beam height. Data have been compared with detailed Monte Carlo simulations using FLUKA for the muon production in the dump and propagation to the detector, and GEANT4 to simulate the detector response. The good agreement between data and simulations, within the uncertainties of the soil composition and density, exhibit the validity of our simulation tools to predict the beam-related muon background in electron beam-dump experiments at ~10 GeV.

47 OTHER INSTRUMENTATION↗

Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search

The Cryogenic Dark Matter Search, or CDMS, collaboration is preparing a new experiment called SuperCDMS. CDMS uses Germanium detectors to attempt the direct detection of dark matter. To do this, they measure the ionization and heat produced during an event where a WIMP scatters off of germanium crystal lattice. To prepare for the experiment the detectors are calibrated with various radioactive sources. The response of the detectors is also modeled by a Monte Carlo simulation. These simulations include modeling everything from the radiation production to the raw data collected by the detector. The experimental data will be used to validate the results of the detector simulation. This research will look only at the phonons produced during events that occur very close to the detector surface. From the raw data and simulation output three parameters will be determined: the rise time, the decay time, and time to position independence. It was found that the simulation's risetime and time to position independence was generally smaller than that of the data, while the decay time was found to be larger in the simulation than in the data. These differences show that the simulation is not complete. The difference in risetime implies that the phonons are not spread out enough when they reach the detector walls, which would be improved by a look at the Luke phonon and charge transport. The long decay time in the simulation implies that the rate phonons are being absorbed is underestimated. Finally, the small time to position independence in the simulation could be due to a low phonon scattering rate. A simple solution may be to alter the parameters that control the simulation, while still remaining physically sensible, to help match simulation and data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Developing a simulation tool for evaluating in-motion detector systems [Slides]

In order to combat the illicit trafficking of nuclear materials, Radiation Detection Systems (RDS) are used to scan pedestrians, vehicles, cargo, luggage, and other conveyances. Many of these systems are used in an “in-motion” configuration where the detector or target are moving past the other. Current modeling and simulation tools lack the ability to produce time-series detector response profiles for in-motion applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Simulation Study of a Pixelated CZT Detector Combined Energy-Independent Collimator Using Finite Element and Monte Carlo Methods for SPECT Applications

Compared to other semiconductor materials, Cadmium Zinc Telluride (CZT) is currently considered a leading material for use in clinical SPECT applications [1]. Over the last few decades, simulation and experimental studies related to the charge sharing effect of pixelated CZT detectors have been performed in order to estimate the charge sharing effect between two neighboring pixels and to determine the optimum pixel size of CZT detectors. The goal of this work is to investigate the charge-transport effect in our pixelated CZT detector design using various radionuclides covering a broad range of gamma emission energies from Tl-201 to I-131 that are used for clinical SPECT applications and to estimate physical effects in the detectors combined with our energy-optimized high-sensitivity pixel-matching parallel-hole collimator [2].

36 MATERIALS SCIENCE↗

RadSim: Detector Response

This package simulates the expected output gamma spectra from a gamma detector for given configuration.

Hangal, DhanushA [Lawrence Livermore National Labo↗

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Charge Collection in Diamond Detectors Irradiated with Deuteron-Triton Neutron Sources

Diamond-based neutron spectrometers exhibit outstanding properties such as radiation hardness, low sensitivity to gamma rays, fast response and high-energy resolution. They represent a very promising application of diamonds for plasma diagnostics in fusion devices. The measured pulse height spectrum is obtained from the collection of helium and beryllium ions produced by the reactions on {sup 12}C. An original code is developed to simulate the production and the transport of charged particles inside the diamond detector. The ion transport methodology is based on the well-known TRIM code. The reactions of interest are triggered using the ENDF/B-VII.0 nuclear data for the neutron interactions on carbon. The model is implemented in the TALLYX subroutine of the MCNP5 and MCNPX codes. Measurements with diamond detectors in a {approx}14 MeV neutron field have been performed at the FNG (Rome, Italy) and IRMM (Geel, Belgium) facilities. The comparison of the experimental data with the simulations validates the proposed model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Electromagnetic Particle Transportation on the GPU

We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

Canal, P.↗

TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92 cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation Validation for the DUNE Near Detector

DUNE will study neutrino oscillations as they are beamed from Fermilab in Batavia, Illinois, 1300 km away to Sanford Underground Research Facility in South Dakota. However, when preparing for an experiment of this scale, it is crucial that we run simulations to validate the geometry and overall design of the project. This poster is comprised of my work during a 2026 SULI internship at Fermilab, involving reading the simulated data and assessing its validity.

Vershaw, Andre [Unlisted, US, IL] (ORCID:000900084↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗

SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.200900420) and the Radiation Technology Research and Development program (Grant No.2013043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of cross section uncertainties on NOvA oscillation analyses

The NOvA experiment is an off-axis long-baseline neutrino oscillation experiment measuring $\nu_{\mu}$ disappearance and $\nu_{e}$ appearance in a $\nu_{\mu}$ beam originating at Fermilab. Oscillations are observed in the far detector relative to measurements made in the near detector, with a full simulation of the beam line and detectors being used to perform extrapolation between them. The neutrino simulation uses the GENIE event generator, which contains implementations of numerous theoretical neutrino interaction models applied to a variety of nuclear targets. However, recent data, recent reanalysis of extant data, and continued development of theoretical models have brought to light deficiencies in the default GENIE cross section model, which informs the predicted spectra used to infer oscillation parameters. We explore how uncertainties in this model, together with modifications to GENIE version 2.12.2 based on external information and NOvA Near Detector (ND) data, affect NOvA's oscillation parameter inferences. We also discuss how these uncertainties can be mitigated by judicious analysis design, including usage of the ND data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine learning neutrino-nucleus cross sections

Neutrino-nucleus scattering cross sections are critical theoretical inputs for long-baseline neutrino oscillation experiments. However, robust modeling of these cross sections remains challenging. For a simple but physically motivated toy model of the DUNE experiment, we demonstrate that an accurate neural-network model of the cross section—leveraging only Standard-Model symmetries—can be learned from near-detector data. We perform a neutrino oscillation analysis with simulated far-detector events, finding that oscillation analysis results enabled by our data-driven cross-section model approach the theoretical limit achievable with perfect prior knowledge of the cross section. We further quantify the effects of flux shape and detector resolution uncertainties as well as systematics from cross-section mismodeling. This proof-of-principle study highlights the potential of future neutrino near-detector datasets and data-driven cross-section models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗