Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

A Broadband Superconducting Detector Suitable for Use in Large Arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of (Delta)E < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.

Day, Peter K.↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

Terahertz Array Receivers with Integrated Antennas

Highly sensitive terahertz heterodyne receivers have been mostly single-pixel. However, now there is a real need of multi-pixel array receivers at these frequencies driven by the science and instrument requirements. In this paper we explore various receiver font-end and antenna architectures for use in multi-pixel integrated arrays at terahertz frequencies. Development of wafer-level integrated terahertz receiver front-end by using advanced semiconductor fabrication technologies has progressed very well over the past few years. Novel stacking of micro-machined silicon wafers which allows for the 3-dimensional integration of various terahertz receiver components in extremely small packages has made it possible to design multi-pixel heterodyne arrays. One of the critical technologies to achieve fully integrated system is the antenna arrays compatible with the receiver array architecture. In this paper we explore different receiver and antenna architectures for multi-pixel heterodyne and direct detector arrays for various applications such as multi-pixel high resolution spectrometer and imaging radar at terahertz frequencies.

direct detector arrays↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

Coupling of TIGRESS and EMMA with Auxiliary Array TIP at TRIUMF

The combination of a germanium detector array and recoil mass spectrometer allows for high-sensitivity experiments in nuclear structure and astrophysics by enabling high-energy-resolution -ray spectroscopy and reaction measurements of weak fusion-evaporation, transfer or radiative-capture reactions in the presence of dominant background reaction channels. The TIGRESS -ray spectrometer with an upgraded data acquisition system has been coupled with the EMMA mass spectrometer alongside a suite of auxiliary detectors housed within TIGRESS such as TIP. This paper reviews the unique combination of radioactive beams at TRIUMF with the capabilities of TIGRESS and EMMA in the context of fusion-evaporation with TIP and radiative-capture reactions without an auxiliary array.

A/Q identification↗

A broadband superconducting detector suitable for use in large arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths.

Crogenic↗

Proceedings of the Third Infrared Detector Technology Workshop

This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.

Mccreight, Craig R.↗

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

Search for double-β decay of 76 Ge to excited states of 76 Se with the Majorana Demonstrator

The M AJORANA DEMONSTRATOR is a neutrinoless double-β decay search consisting of a low-background modular array of high-purity germanium detectors, ~2/3 of which are enriched to 88% in 76 Ge. The experiment is also searching for double-beta decay of 76 Ge to excited states (e.s.) in 76 Se. 76 Ge can decay into three daughter states of 76 Se, with clear event signatures consisting of a ββ-decay followed by the prompt emission of one or two γ rays. This results with high probability in multi-detector coincidences. In this work, the granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9 kg yr of isotopic exposure, the DEMONSTRATOR has set world leading limits for each e.s. decay of 76 Ge, with 90% CL lower half-life limits in the range of (0.75–4.0) × 10 24 yr. In particular, for the 2ν transition to the first 0 + e.s. of 76 Se, a lower half-life limit of 7.5 × 10 23 yr at 90% CL was achieved.

59 ≤ A ≤ 89↗

Near-Infrared Hyperspectral Image Cubes of Mars during the 1999 Opposition

We used the Goddard Space Flight Center, Acousto-Optic Tunable Filter (AOTF) Camera to obtain near-IR spectral image sets of Mars over the 1.6-3.6 micron region during the April 1999 opposition. A complete image set consists of 280 images with a spectral full-width-half maximum of 10 wavenumbers (fixed in frequency), 90 images in H-band (1.55-1.80 micron), 115 images in K-band (1.95-2.50 micron) and 75 images in L-band (2.90-3.70 micron). The short-wavelength limit is set by transmission of AOTF cell and long-wavelength limit is imposed by sensitivity of PICNIC, 256x256, HgCdTe array detector. We will discuss the new array performance and provide preliminary interpretations of some of these results. These measurements were part of a 4-observatory coordinated effort whose overall objective was to assemble a photometrically calibrated, spectrally complete ground-based image cube over the visible and near-IR spectral region. To accomplish this, four observing teams conducted the investigations with instruments spanning 0.4 to 5.0 micron. The instruments and observing facilities were (a) AOTF camera at Apache Point Observatory, 3.5m, f/10, Nasymth focus (this abstract). Primary science targets included the 3 micron water-of hydration feature and CO2, H2O ice (polar regions and clouds); (b) Visible/NIR interference-filter (24 filters) camera at Lowell Observatory, 72" telescope. 430-1050 nm. Science targets were Fe(2+), Fe(3+) mineralogy and coarse grain hematite search; (c) NMSU Tortugas Mountain Observatory, 60 cm telescope, CCD photometry with same filter set as Lowell; (d) KPNO cryogenic grating/slit spectrometer (CRSP/SALLY) at KPNO 2.1 m, f/15 Cassegrain focus (see abstract by D. Glenar, et. al., this meeting). Selected wavelengths in 3-5 micron region (L, M band). Science targets included water-of-hydration feature (3-4 micron long wave extension) and sulfate mineralogy. Observers participating in this campaign included Dave Glenar, John Hillman, Gordon Bjoraker and Fred Espenak from GSFC, Nancy Chanover, Jim Murphy and A. S. MurTell from NMSU, Leslie Young from BU, Diana Blaney from JPL and Dick Joyce from KPNO.

Hillman, John J.↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.

Instruments & Instrumentation↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Shuttle imaging spectrometer optics

This paper discusses the optical design and performance of the Shuttle Imaging Spectrometer (SISEX) optical system, which is being planned for the next generation of Earth remote sensing instruments. This optical system represents a new approach to remote sensing in which wide-field optics, dispersing elements, and area detector arrays are used in place of mechanical scanners, filters, and discrete detector elements or linear arrays. While the SISEX optical system is designed specifically for flight on Shuttle, the same optical approach is being used in the design of other remote sensing instruments, such as the High Resolution Imaging Spectrometer, which is expected to fly on the Earth Observing System.

Page, N. A.↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗