Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Technical Letter Report Assessment of Ultrasonic Phased Array Inspection Method for Welds in Cast Austenitic Stainless Steel Pressurizer Surge Line Piping JCN N6398, Task 1B

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the inspection of light water reactor components. The scope of this research encompasses primary system pressure boundary materials including cast austenitic stainless steels (CASS); dissimilar metal welds; piping with corrosion-resistant cladding; weld overlays, inlays and onlays; and far-side examinations of austenitic piping welds. A primary objective of this work is to evaluate various NDE methods to assess their ability to detect, localize, and size cracks in coarse-grained steel components. In this effort, PNNL supports cooperation with Commissariat à l’Energie Atomique (CEA) to assess reliable inspection of CASS materials. The NRC Project Manager has established a cooperative effort with the Institut de Radioprotection et de Surete Nucleaire (IRSN). CEA, under funding from IRSN, are supporting collaborative efforts with the NRC and PNNL. Regarding its work on the NDE of materials, CEA is providing its modeling software (CIVA) in exchange for PNNL offering expertise and data related to phased-array detection and sizing, acoustic attenuation, and back scattering on CASS materials. This collaboration benefits the NRC because CEA performs research and development on CASS for Électricité de France (EdF). This technical letter report provides a summary of a technical evaluation aimed at assessing the capabilities of phased-array (PA) ultrasonic testing (UT) methods as applied to the inspection of welds in CASS pressurizer (PZR) surge line nuclear reactor piping. A set of thermal fatigue cracks (TFCs) was implanted into three CASS PZR surge-line specimens (pipe-to-elbow welds) that were fabricated using vintage CASS materials formed in the 1970s, and flaw responses from these cracks were used to evaluate detection and sizing performance of the PA-UT methods applied. This effort was comprised of multiple elements that included use of microstructural knowledge (dimensional analysis, grain orientation, and grain type) as well as sound field modeling to more effectively modify inspection parameters and enhance the inspection outcomes. Advanced probe design and sound field simulations were employed to enhance detection and characterization of circumferentially oriented flaws, and an assessment of lateral (circumferential) flaw localization capability and performance was also conducted. An evaluation of flaw detection, length sizing, depth sizing, and signal-to-noise ratio was performed for all flaws in the subject specimens, as a function of various inspection parameters, and finally, measurements were made to quantify and assess the baseline CASS material noise and its potential impact on flaw detection.

36 MATERIALS SCIENCE↗

Nondestructive techniques for characterizing mechanical properties of structural materials: An overview

An overview of nondestructive evaluation (NDE) is presented to indicate the availability and application potentials of techniques for quantitative characterization of the mechanical properties of structural materials. The purpose is to review NDE techniques that go beyond the usual emphasis on flaw detection and characterization. Discussed are current and emerging NDE techniques that can verify and monitor entrinsic properties (e.g., tensile, shear, and yield strengths; fracture toughness, hardness, ductility; elastic moduli) and underlying microstructural and morphological factors. Most of the techniques described are, at present, neither widely applied nor widely accepted in commerce and industry because they are still emerging from the laboratory. The limitations of the techniques may be overcome by advances in applications research and instrumentation technology and perhaps by accommodations for their use in the design of structural parts.

Vary, A.↗

Nondestructive techniques for characterizing mechanical properties of structural materials - An overview

An overview of nondestructive evaluation (NDE) is presented to indicate the availability and application potentials of techniques for quantitative characterization of the mechanical properties of structural materials. The purpose is to review NDE techniques that go beyond the usual emphasis on flow detection and characterization. Discussed are current and emerging NDE techniques that can verify and monitor entrinsic properties (e.g., tensile, shear, and yield strengths; fracture toughness, hardness, ductility; elastic moduli) and underlying microstructural and morphological factors. Most of the techniques described are, at present, neither widely applied nor widely accepted in commerce and industry because they are still emerging from the laboratory. The limitations of the techniques may be overcome by advances in applications research and instrumentation technology and perhaps by accommodations for their use in the design of structural parts.

Vary, A.↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Gas cluster ion beam for the characterization of organic materials in submarine basalts as Mars analogs

The solar system contains large quantities of organic compounds that can form complex molecular structures. The processing of organic compounds by biological systems leads to molecules with distinctive structural characteristics; thus, the detection and characterization of organic materials could lead to a high degree of confidence in the existence of extra-terrestrial life. Given the nature of the surface of most planetary bodies in the solar system, evidence of life is more likely to be found in the subsurface where conditions are more hospitable. Basalt is a common rock throughout the solar system and the primary rock type on Mars and Earth. Basalt is therefore a rock type that subsurface life might exploit and as such a suitable material for the study of methods required to detect and analyze organic material in rock. Telluric basalts from Earth represent an analog for extra-terrestrial rocks where the indigenous organic matter could be analyzed for molecular biosignatures. This study focuses on organic matter in the basalt with the use of surface analysis techniques utilizing Ar gas cluster ion beams (GCIB); time of flight secondary ion mass spectrometry (ToF-SIMS), and x-ray photoelectron spectroscopy (XPS), to characterize organic molecules. Tetramethylammonium hydroxide (TMAH) thermochemolysis was also used to support the data obtained using the surface analysis techniques. The authors demonstrate that organic molecules were found to be heterogeneously distributed within rock textures. A positive correlation was observed to exist between the presence of microtubule textures in the basalt and the organic compounds detected. From the results herein, the authors propose that ToF-SIMS with an Ar GCIB is effective at detecting organic materials in such geological samples, and ToF-SIMS combined with XPS and TMAH thermochemolysis may be a useful approach in the study of extra-terrestrial organic material and life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pointing Control System Design and Performance Evaluation for TPF Coronagraph

The Terrestrial Planet Finder (TPF) program aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the four mission concepts being studied. In order to reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of- sight control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time.

Liu, Kuo-Chia↗

The Wide Field X-ray Telescope Mission--A Digital Sky Survey in X-rays

Sensitive surveys of the X-ray universe have been limited to small areas of the sky due to the intrinsically small field of view of Wolter-I X-ray optics. High angular resolution is needed to achieve a low background per source, minimize source confusion, and distinguish point from extended objects. WFXT consists of three co-aligned wide field X-ray telescopes with a 1 deg. field of view and a < or approx. 10''(goal of 5'') angular resolution (HEW) over the full field. Total effective area at 1 keV will be >5000 cm{sup -2}. WFXT will perform three extragalactic surveys that will cover most of the sky to 100-1000 times the sensitivity of the ROSAT All Sky Survey, > ir approx. 2000 deg{sup 2} to deep Chandra or XMM-Newton sensitivity, and > or approx. 100 deg{sup 2} to the deepest Chandra sensitivity. WFXT will generate a legacy X-ray dataset of a half million clusters and groups of galaxies to z{approx_equal}2, also characterizing the physics of the intracluster gas for a significant fraction of them, thus providing an unprecedented data set for cosmological applications; it will detect >10{sup 7} AGN to z>6, again obtaining spectra for a substantial fraction, to study the growth of supermassive black holes; it will detect >10{sup 5} normal/starburst galaxies; and it will detect and characterize star formation regions across the Galaxy. WFXT is the only X-ray survey mission that will match, in area and sensitivity, the next generation of wide-area optical, IR and radio surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

HabEx Space Telescope Optical System Overview: General Astrophysics Instruments

The HabEx (Habitable Exoplanet) concept study is defining a future space telescope with the primary mission of detecting and characterizing planetary systems around nearby stars. The telescope baseline design includes a high-contrast coronagraph and a starshade to enable the direct optical detection of exoplanets as close as 70 mas to their star. In addition to the study of exoplanets, HabEx carries two dedicated instruments for general astrophysics. The first instrument is a camera enabling imaging on a 3 arc minute field of view in two bands stretching from the UV at 150 nm to the near infrared at 1800 nm. The same instrument can also be operated as a multi-object spectrograph, with resolution of 2000. The second instrument is a high-resolution UV spectrograph operating from 300 nm down to 115 nm with up to 60,0000 resolution. HabEx would provide the highest resolution UV/optical images ever obtained. Diffraction limited at 0.4 µm, it would outperform all current and approved facilities, including the 30 m class ground-based extremely large telescopes (ELTs), which will achieve ~0.01 arcsecond resolution at near-infrared (IR) wavelengths with adaptive optics, but will be seeing-limited at optical wavelengths. HabEx would observe wavelengths inaccessible from the ground, including the UV and in optical/near-IR atmospheric absorption bands. Operating at L2, far above the Earth’s atmosphere and free from the large thermal swings inherent to HST’s low-Earth orbit, HabEx would provide an ultra-stable platform that will enable science ranging from precision astrometry to the most sensitive weak lensing maps ever obtained. Here we discuss the design concepts of the general astrophysics optical instruments for the proposed observatory.

Nissen, Joel↗

Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

Wiberg, D. V.↗

Single visit completeness optimization

The Terrestrial Planet Finder Coronagraph (TPF-C) is a NASA pre-phase. A orbiting telescope with the goal of detecting and characterizing visible and near-IR light refelected from terrestrial planets. We use observational completeness, defined as the fraction of potentially observable planets that are detected, to determine how well the proposed telescope meets the mission goals. Single visit completeness is optimized by slecting the length of observation per target that maximizes the completeness for the ensemble of stars. In this memo we describe the integration time calculations and two approaches to single visit optimization.

optimization↗

Characterization of volcanic tuff pores pre- and post-underground nuclear detonation using ultra-small and small angle neutron scattering

The ability to accurately model the subsurface transport of radionuclides is fundamental to the remote detection and characterization of underground nuclear explosion (UNE) events. Developing more sophisticated transport models presents a significant opportunity to enhance monitoring capabilities, particularly in the reliable prediction of signature migration. Experimentally determined characterization of geologic materials associated with transport properties is the pertinent base information for such robust model development and calibration. Here, we report results from an unprecedented study demonstrating changes to the pore and fracture network structures in geological materials in response to UNEs over nanometer to micrometer length scales. Volcanic tuffs of five different lithological formations from pre- and post-UNE environments were collected from the Nevada National Security Site. Combined ultra-small and small-angle neutron scattering techniques were used to characterize the tuff pore structure. The results demonstrate measurable differences in the specific surface area and porosity of samples pre- and post-shot from texturally similar lithological formations, indicating that pore properties can serve as a direct physical signature of a UNE. The results also provide experimentally determined transport parameters in support of advanced model development through the integration of gas migration, hydrodynamic simulations, and geologic framework models.

54 ENVIRONMENTAL SCIENCES↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based gating and logic for multichannel single photon counting

We present results characterizing multichannel InGaAs single photon detectors utilizing gated passive quenching circuits (GPQC), self-differencing techniques, and field programmable gate array (FPGA)-based logic for both diode gating and coincidence counting. Utilizing FPGAs for the diode gating frontend and the logic counting backend has the advantage of low cost compared to custom built logic circuits and current off-the-shelf detector technology. Further, FPGA logic counters have been shown to work well in quantum key distribution (QKD) test beds. Our setup combines multiple independent detector channels in a reconfigurable manner via an FPGA backend and post processing in order to perform coincidence measurements between any two or more detector channels simultaneously. Using this method, states from a multi-photon polarization entangled source are detected and characterized via coincidence counting on the FPGA. Photons detection events are also processed by the quantum information toolkit for application testing (QITKAT)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗

Isomer-specific spectroscopy of aromatics and their resonance-stabilized radical intermediates

There are many circumstances in which complex gas-phase reaction mixtures must be interrogated and understood, including combustion, plasmas, atmospheres, and molecular clouds. Spectroscopic tools are essential to selective detection and characterization of the widening array of precursors and the reactive intermediates they generate. This research program has focused on the development and implementation of sensitive spectroscopic detection schemes that are isomer-specific and even conformation-specific. In particular, we used an array of laser-based and broadband microwave methods to carry out isomer-specific and conformation-specific spectroscopy on large flexible molecules and reactive intermediates formed by photolysis, pyrolysis, combustion, or electron-driven chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

Direct Imaging and Spectroscopy of Exoplanetary Systems with the JWST Early Release Science Program

The direct characterization of exoplanetary systems with high contrast imaging is among the highest priorities for the broader exoplanet community. As large space missions will be necessary for detecting and characterizing exo-Earth twins, developing the techniques and technology for direct imaging of exoplanets is a driving focus for the community. For the first time, JWST will directly observe extrasolar planets at mid-infrared wavelengths beyond 5 μm, deliver detailed spectroscopy revealing much more precise chemical abundances and atmospheric conditions, and provide sensitivity to analogs of our solar system ice-giant planets at wide orbital separations, an entirely new class of exoplanet. However, in order to maximise the scientific output over the lifetime of the mission, an exquisite understanding of the instrumental performance of JWST is needed as early in the mission as possible. In this paper, we describe our 55-hour Early Release Science Program that will utilize all four JWST instruments to extend the characterisation of planetary mass companions to ∼15-20 μm as well as image a circumstellar disk in the mid-infrared with unprecedented sensitivity. Our program will also assess the performance of the observatory in the key modes expected to be commonly used for exoplanet direct imaging and spectroscopy, optimize data calibration and processing, and generate representative datasets that will enable a broad user base to effectively plan for general observing programs in future cycles.

Michael W McElwain↗

Threshold detection in pulsed laser ranging

Suzaki and Tachibana (1972, 1973) have developed a method for detecting the arrival time of the return pulse in pulsed laser ranging based on the identification of the time at which the preset threshold level is exceeded by the output of the optical detector. The received optical pulse is considered to be made up of cells of width equal to the resolution time of the receiver and an equation is derived for P sub j, the probability that the threshold is first exceeded in the j-th cell. Using the density P sub j, expressions are obtained for the mean position of the cell at which threshold occurs and for the standard deviation (rms error) in the detection cell. The present paper maintains that, since the number j is purely an artifice for identifying the cells, its mean and standard deviation are inadequate for characterizing the detection cell and detection errors. It is proposed that if the detection cell is defined as the cell at which P sub j attains a maximum, then the above-cited ambiguity would be eliminated.

Iyer, R. S.↗