Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect And Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Inhibitive formation of nanocavities by introduction of Si atoms in Ge nanocrystals produced by ion implantation

Germanium nanocrystals (Ge-nc) were successfully synthesized by co-implantation of Si and Ge ions into a SiO{sub 2} film thermally grown on (100) Si substrate and fused silica (pure SiO{sub 2}), respectively, followed by subsequent annealing at 1150 °C for 1 h. Transmission electron microscopy (TEM) examinations show that nanocavities only exist in the fused silica sample but not in the SiO{sub 2} film on a Si substrate. From the analysis of the high-resolution TEM images and electron energy-loss spectroscopy spectra, it is revealed that the absence of nanocavities in the SiO{sub 2} film/Si substrate is attributed to the presence of Si atoms inside the formed Ge-nc. Because the energy of Si-Ge bonds (301 kJ·mol{sup −1}) are greater than that of Ge-Ge bonds (264 kJ·mol{sup −1}), the introduction of the Si-Ge bonds inside the Ge-nc can inhibit the diffusion of Ge from the Ge-nc during the annealing process. However, for the fused silica sample, no crystalline Si-Ge bonds are detected within the Ge-nc, where strong Ge outdiffusion effects produce a great number of nanocavities. Our results can shed light on the formation mechanism of nanocavities and provide a good way to avoid nanocavities during the process of ion implantation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sorting for secreted molecule production using a biosensor-in-microdroplet approach

Significance The design–build–test cycle of metabolic engineering is swiftly becoming test limited owing to advances in DNA synthesis and library design. At the same time, improving extracellular production requires high-throughput studies to detect extracellular (not intracellular) content. Traditional approaches that utilize chromatography-based analysis or plate-based fluorescence assays are relatively throughput limited and require a high degree of liquid handling. These limitations are avoided here by creating a generalizable approach for small molecule production screening. Namely, this paradigm combines “off-the-shelf” biosensors with large library screening from producing cells in a cell-type agnostic manner.

Bowman, Emily K.↗

Optimization of Pressurized Oxy-Combustion with Flameless Reactor

Pressurized OxyECombustion is one of the most promising technologies for utility-scale power generation plants. Benefits include the ability to burn low rank coal and capture CO 2 . By increasing the flue gas pressure during this process, greater efficiencies are derived from increased quantity and quality of thermal energy recovery. UPA with modeling support from MIT and testing and data verification by Georgia Tech’s Research Center designed and built a 100 kW system capable of demonstrating pressurized oxyEcombustion using a flameless combustor. Wyoming PRB coal was run at 15 and 32 bar. Additional tests were not completed but sampled data demonstrated the viability of the technology over a broader range of operating pressures, Modeling results illustrated a flat efficiency curve over 20 bar, with optimum efficiency achieved at 29 bar. This resulted in a 33% (HHV) efficiency, a 5 points increase in efficiency versus atmospheric oxy-combustion, and a competitive cost of electricity plus greater CO 2 avoidance costs then prior study’s presented. UPA’s operation of the bench-scale system provided evidence that key performance targets were achieved: flue gas sampled at the combustor outlet had non-detectable residual fly ashes, and low levels of SO3 and heavy-metal. These results correspond to prior pressurized oxy-combustion testing completed by IteaEEnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twinning and Predictive Modeling of Traffic for Safe, Efficient, and Reliable Intersections

Over the last decade, the advances in connected and autonomous vehicles (CAVs) have far surpassed the technological realm of transportation infrastructure. There is a growing need to have a technologically commensurate transportation infrastructure to enable safe and reliable movement of goods and people. The recent creation of Advanced Research Projects Agency - Infrastructure (ARPA-I) through the Infrastructure Investment and Jobs Act by the U.S. Department of Transportation (USDOT) has further amplified the need to revolutionize the transportation infrastructure system in the US. This need is perhaps felt most at traffic intersections, as more than 50 percent of the combined total of fatal and injury crashes occur at or near intersections. The proposed concept of Infrastructure Perception and Control (IPC) is aimed at bridging this technological gap by building a real-time digital twin of traffic by fusing detections from sensors installed at the intersection. This digital twin can then empower a wide variety of applications such as smart traffic signals or infrastructure-to-everything (I2X) communications. Smart signaling can help avoid crashes through early-prediction, while I2X can augment the CAV sensors under uncertain driving conditions and provide connected vehicles (CVs) with traffic information they can use to optimize their travel.

connected vehicles↗

Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity of mice

Highlights: • We identified mouse 5 bitter taste receptors (Tas2rs) which respond to tea catechin. • Among these receptors, Tas2r125 showed the strongest response to catechins. • The response profiles of Tas2r125 were consistent with the behavior profiles. • Tas2r125 expression was not observed in the tested tissues except the taste papillae. • Tas2r125 plays as the catechin receptor in the oral cavity. We attempted to identify mouse bitter taste receptors, Tas2rs, that respond to tea catechins. Among representative tea catechins, avoidance behavior of mice to (−)–epicatechin gallate (ECg) was the strongest, followed by (−)–epigallocatechin gallate (EGCg). Therefore, we measured ECg response using Tas2rs-expressing cells. Among the 35 members of Tas2r family, Tas2r108, 110, 113, 125, and 144 responded to ECg. Among these receptors, Tas2r113 and 125 also responded to EGCg. Because the response profiles of Tas2r125 were consistent with the results of the behavior assays, it was considered that Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity. To determine the involvement of Tas2rs in the physiological action of catechins, mRNA expression of 5 Tas2rs was investigated in various tissues. Because mRNA expression of Tas2r108 was observed in some tissues including the gastrointestinal tract, it may be envisaged that Tas2r108 plays a part in exerting the physiological action of ECg. Tas2r125 expression was not observed in any of the tested tissues except the circumvallate papillae. Therefore, Tas2r125 was considered to mainly function in the events of catechin reception in the oral cavity.

60 APPLIED LIFE SCIENCES↗

Noise suppression for MHD characterization with electron cyclotron emission imaging 1D technique

Significant noise suppression for magnetohydrodynamics (MHD) mode characterization in the spatial and spectral domain is achieved by processing two-dimensional (2D) electron cyclotron emission imaging (ECEI) data with a one-dimensional (1D) ECEI technique using a short time window ($1\;{\text{ms}}$). The technique is applied to detect toroidal Alfven eigenmodes (TAEs) in the temporal spectrum and fit their radial envelope using the data from the DIII-D tokamak W-band 2D ECEI system. Using the data length (time window) of only 1 ${\text{ms}}$, the 1D ECEI can clearly detect the TAEs (~100 ${\text{kHz}}$) on the spectrum, while similar spectrum quality requires ~10 ${\text{ms}}$ data length with the cross power spectrum between two midplane ECEI channels. The 1D ECEI technique also effectively avoids biased fitting when resolving the fine structure of the TAE's radial envelope. The radially spatial resolution of 1D ECEI is constrained by the finite ECE radiation volume of the ECEI receiver. Here, with forward radiation modeling, we find the DIII-D ECEI system can sensitively measure the even parity MHD activities, for which the mode width is >15 mm, and tearing modes (odd parity MHD activities), for which the island full width is >30 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An opposite view data replacement approach for reducing artifacts due to metallic dental objects

Purpose: To present a conceptually new method for metal artifact reduction (MAR) that can be used on patients with multiple objects within the scan plane that are also of small sized along the longitudinal (scanning) direction, such as dental fillings. Methods: The proposed algorithm, named opposite view replacement, achieves MAR by first detecting the projection data affected by metal objects and then replacing the affected projections by the corresponding opposite view projections, which are not affected by metal objects. The authors also applied a fading process to avoid producing any discontinuities in the boundary of the affected projection areas in the sinogram. A skull phantom with and without a variety of dental metal inserts was made to extract the performance metric of the algorithm. A head and neck case, typical of IMRT planning, was also tested. Results: The reconstructed CT images based on this new replacement scheme show a significant improvement in image quality for patients with metallic dental objects compared to the MAR algorithms based on the interpolation scheme. For the phantom, the authors showed that the artifact reduction algorithm can efficiently recover the CT numbers in the area next to the metallic objects. Conclusions: The authors presented a new and efficient method for artifact reduction due to multiple small metallic objects. The obtained results from phantoms and clinical cases fully validate the proposed approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MagMicro with Ultra-High Energy Resolution (Progress Report Q4 FY18)

We are performing extensive simulations of the MMC detector response to optimize their energy resolution, detection efficiency and count rate based on the data we took in FY17/18. The optimized layout separates the MMC detector chip from the SQUID preamplifier chips coupled to the MMCs through Al wire bonds to avoid heating the MMC with the power dissipation of the SQUID. The goal is to design MMC gamma detectors with a limiting energy resolution below ~25 eV FWHM up to >100 keV and ~1 ms decay times for maximum count rates of several tens of counts/s per pixel. The simulations, which were done at the Supercomputing Center of the University of New Mexico, are taking significantly longer than expected. The difficulty is that the device performance depends intricately on the design parameters, and each simulation is quite involved because it needs to cover the frequency range well into the GHz range to account for the ac Josephson effect. This is delaying the start of the detector array fabrication, and we have not been able to complete the fabrication and the testing of the 32-pixel MMC arrays by September 30. We have therefore requested a no-cost extension of the project to March 31, 2019.

42 ENGINEERING↗

Safeguards by design - industry engagement for new uranium enrichment facilities in the United States

The United States Department of Energy's (DOE's) Office of Nonproliferation and International Security (NA-24) has initiated a Safeguards by Design (SBD) effort to encourage the incorporation of international (IAEA) safeguards features early in the design phase of a new nuclear facility in order to avoid the need to redesign or retrofit the facility at a later date. The main goals of Safeguards by Design are to (1) make the implementation of international safeguards at new civil nuclear facilities more effective and efficient, (2) avoid costly and time-consuming re-design work or retrofits at such facilities and (3) design such facilities in a way that makes proliferation as technically difficult, as time-consuming, and as detectable as possible. The U.S. Nuclear Regulatory Commission (NRC) has recently hosted efforts to facilitate the use of Safeguards by Design for new uranium enrichment facilities currently being planned for construction in the U.S. While SBD is not a NRC requirement, the NRC is aiding the implementation of SBD by coordinating discussions between DOE's NA-24 and industry's facility design teams. More specifically, during their normal course of licensing discussions the NRC has offered industry the opportunity to engage with NA-24 regarding SBD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How gravitational lensing helps γ-ray photons avoid γ – γ absorption

We investigate potential γ – γ absorption of γ-ray emission from blazars arising from inhomogeneities along the line of sight, beyond the diffuse Extragalactic Background Light (EBL). As plausible sources of excess γ – γ opacity, we consider (1) foreground galaxies, including cases in which this configuration leads to strong gravitational lensing, (2) individual stars within these foreground galaxies, and (3) individual stars within our own galaxy, which may act as lenses for microlensing events. We found that intervening galaxies close to the line of sight are unlikely to lead to significant excess γ – γ absorption. This opens up the prospect of detecting lensed gamma-ray blazars at energies above 10 GeV with their gamma-ray spectra effectively only affected by the EBL. The most luminous stars located either in intervening galaxies or in our galaxy provide an environment in which these gamma-rays could, in principle, be significantly absorbed. However, despite a large microlensing probability due to stars located in intervening galaxies, γ-rays avoid absorption by being deflected by the gravitational potentials of such intervening stars to projected distances ({sup i}mpact parameters{sup )} where the resulting γ – γ opacities are negligible. Thus, neither of the intervening excess photon fields considered here, provide a substantial source of excess γ – γ opacity beyond the EBL, even in the case of very close alignments between the background blazar and a foreground star or galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE CHANDRA VARIABLE GUIDE STAR CATALOG

Variable stars have been identified among the optical-wavelength light curves of guide stars used for pointing control of the Chandra X-ray Observatory. We present a catalog of these variable stars along with their light curves and ancillary data. Variability was detected to a lower limit of 0.02 mag amplitude in the 4000-10000 A range using the photometrically stable Aspect Camera on board the Chandra spacecraft. The Chandra Variable Guide Star Catalog (VGUIDE) contains 827 stars, of which 586 are classified as definitely variable and 241 are identified as possibly variable. Of the 586 definite variable stars, we believe 319 are new variable star identifications. Types of variables in the catalog include eclipsing binaries, pulsating stars, and rotating stars. The variability was detected during the course of normal verification of each Chandra pointing and results from analysis of over 75,000 guide star light curves from the Chandra mission. The VGUIDE catalog represents data from only about 9 years of the Chandra mission. Future releases of VGUIDE will include newly identified variable guide stars as the mission proceeds. An important advantage of the use of space data to identify and analyze variable stars is the relatively long observations that are available. The Chandra orbit allows for observations up to 2 days in length. Also, guide stars were often used multiple times for Chandra observations, so many of the stars in the VGUIDE catalog have multiple light curves available from various times in the mission. The catalog is presented as both online data associated with this paper and as a public Web interface. Light curves with data at the instrumental time resolution of about 2 s, overplotted with the data binned at 1 ks, can be viewed on the public Web interface and downloaded for further analysis. VGUIDE is a unique project using data collected during the mission that would otherwise be ignored. The stars available for use as Chandra guide stars are generally 6-11 mag and are commonly spectral types A and later. Due to the selection of guide stars entirely for positional convenience, this catalog avoids the possible bias of searching for variability in objects where it is to be expected. Statistics of variability compared to spectral type indicate the expected dominance of A-F stars as pulsators. Eclipsing binaries are consistently 20%-30% of the detected variables across all spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Color Ultrafast Photoexcited Scanning Tunneling Microscopy

We report on two-color two-photon photoexcitation of a metal surface driven by ultrafast laser pulses and detected with a scanning tunneling microscope (STM) tip as a proximate anode. Results are presented for two cases: (i) where the tip is retracted from the surface far enough to prohibit tunneling, and (ii) where the tip is within tunneling range of the surface. A delay-modulation technique is implemented to isolate the two-color photoemission from concurrent one-color two-photon photoemission and provide subpicosecond time-resolved detection. When applied with the tip in tunneling range, this approach effectively isolates the two-photon photoexcited current signal from the conventional tunneling current and enables subpicosecond time-resolved detection of the photoexcited surface electrons. The advantage of the two-color approach is highlighted by comparison with the one-color case where optical interference causes thermal modulation of the STM tip length, resulting in tunneling current modulations that are orders of magnitude larger than the current due to photoexcitation of surface electrons. By completely eliminating this interference, and thereby avoiding thermal modulation of the STM tip length, the two-color approach represents an important step toward the ultimate goal of simultaneous subnanometer and subpicosecond measurements of surface electron dynamics by ultrafast-laser-excited STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Is a Short-Interval Postradiation Mammogram Necessary After Conservative Surgery and Radiation in Breast Cancer?

Purpose: To examine, in a retrospective study, whether the initial posttreatment mammogram offers any benefit to patients. Methods and Materials: Patients were selected who had radiation after breast-conservation therapy from 1995 through 2005 and had follow-up mammography at University of California-Los Angeles (UCLA) within 1 year of completing radiotherapy. Results of the initial follow-up mammogram were analyzed to determine the yield of this initial mammogram. Results: Between 1995 and 2005, 408 patients treated with breast-conserving therapy and radiation had follow-up mammograms at UCLA within 1 year of completion of radiation. Median age at radiation completion was 56.9 years. Median interval between radiation and the initial mammogram was 3.1 months. Ten patients were found to have suspicious findings on the initial postradiation mammogram, prompting biopsy, but only 2 were found to have recurrent cancer. None of those lesions were palpable. In both cases the recurrences were ductal carcinoma in situ. Thus, the yield of the initial postoperative mammogram as compared with physical examination findings is estimated at 0.49 recurrences detected per 100 mammograms performed (95% confidence interval 0.059-1.759). Conclusions: The yield of the initial postradiation mammography at UCLA seems to be low, and only noninvasive carcinomas were found. Our data support the rationale to avoid the initial short-interval postradiation mammography and evaluate patients at 12 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replication-competent human adenovirus 11p vectors can propagate in Vero cells

The use of continuous cell lines derived from the African green monkey kidney (AGMK) has led to major advances in virus vaccine development. However, to date, these cells have not been used to facilitate the creation of human adenoviruses because most human adenoviruses undergo abortive infections in them. Here, we report the susceptibility of AGMK-derived cells to adenovirus 11p (Ad11p) infection. First, we showed that CD46 molecules, which act as receptors for Ad11p, are expressed in AGMK cells. We then monitored Ad11p replication by measuring GFP expression as an indicator of viral transcription. We found that AGMK-derived cells were as capable as carcinoma cells at propagating full-length replication-competent Ad11p (RCAd11p) DNA. Of the AGMK cell lines tested, Vero cells had the greatest capacity for adenovirus production. Thus, AGMK cells can be used to evaluate RCAd11p-mediated gene delivery, and Vero cells can be used for the production of RCAd11pGFP vectors at relatively high yields. - Highlights: • Africa green monkey cell lines were monitored for human adenovirus 11p GFP vector infection. • Human CD46 molecules were detectable in these monkey cell lines. • Adenovirus 11p GFP vector can be propagated in Vero cells increases the safety of Ad11p-based vectors for clinical trials. • To use Vero cells for preparation of Ad11p vector avoids the potential inclusion of oncogenes from tumor cells.

60 APPLIED LIFE SCIENCES↗

PLUTINO DETECTION BIASES, INCLUDING THE KOZAI RESONANCE

Because of their relative proximity within the trans-Neptunian region, the plutinos (objects in the 3:2 mean-motion resonance with Neptune) are numerous in flux-limited catalogs, and well-studied theoretically. We perform detailed modeling of the on-sky detection biases for plutinos, with special attention to those that are simultaneously in the Kozai resonance. In addition to the normal 3:2 resonant argument libration, Kozai plutinos also show periodic oscillations in eccentricity and inclination, coupled to the argument of perihelion ({omega}) oscillation. Due to the mean-motion resonance, plutinos avoid coming to pericenter near Neptune's current position in the ecliptic plane. Because Kozai plutinos are restricted to certain values of {omega}, perihelion always occurs out of the ecliptic plane, biasing ecliptic surveys against finding these objects. The observed Kozai plutino fraction f{sub koz}{sup obs} has been measured by several surveys, finding values between 8% and 25%, while the true Kozai plutino fraction f{sub koz}{sup true} has been predicted to be between 10% and 30% by different giant planet migration simulations. We show that f{sub koz}{sup obs} varies widely depending on the ecliptic latitude and longitude of the survey, so debiasing to find the true ratio is complex. Even a survey that covers most or all of the sky will detect an apparent Kozai fraction that is different from f{sub koz}{sup true}. We present a map of the on-sky plutino Kozai fraction that would be detected by all-sky flux-limited surveys. This will be especially important for the Panoramic Survey Telescope and Rapid Response System and Large Synoptic Survey Telescope projects, which may detect large numbers of plutinos as they sweep the sky. f{sub koz}{sup true} and the distribution of the orbital elements of Kozai plutinos may be a diagnostic of giant planet migration; future migration simulations should provide details on their resonant Kozai populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrieval of Aerosol Optical Depth in Vicinity of Broken Clouds from Reflectance Ratios: Sensitivity Study

We conducted a sensitivity study to better understand the potential of a new method for retrieving aerosol optical depth (AOD) under partly cloudy conditions. This method exploits reflectance ratios in the visible spectral range and provides an effective way to avoid three-dimensional (3D) cloud effects. The sensitivity study is performed for different observational conditions and random errors in input data. The results of the sensitivity study suggest that this ratio method has the ability to detect clear pixels even in close proximity to clouds. Such detection does not require a statistical analysis of the two-dimensional (2D) horizontal distribution of reflected solar radiation, and thus it could be customized for operational retrievals. In comparison with previously suggested approaches, the ratio method has the capability to increase the "harvest" of clear pixels. Similar to the traditional Independent Pixel Approximation (IPA), the ratio method has a low computational cost for retrieving AOD. In contrast to the IPA method, the ratio method provides much more accurate estimations of the AOD values under broken cloud conditions: pixel-based and domain-averaged estimations of errors in AOD are about 25% and 10%, respectively. Finally, both the ratio-based cloud screening and the accuracy of domain-averaged ratio-based AOD values do not suffer greatly when 5% random errors are introduced in the reflectances.

54 ENVIRONMENTAL SCIENCES↗