Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

In situ metrology to characterize water vapor delivery during atomic layer deposition

Water is often employed as the oxygen source in metal oxide atomic layer deposition (ALD) processes. It has been reported that variations in the amount of water delivered during metal oxide ALD can impact the oxide film properties. Hence, one contribution to optimizing metal oxide ALD processes would be to identify methods to better control water dose. The development of rapid, quantitative techniques for in situ water vapor measurements during ALD processes would be beneficial to achieve this goal. In this report, the performance of an in situ tunable diode laser absorption spectroscopy (TDLAS) scheme for performing rapid, quantitative water partial pressure measurements in a representative quarter-inch ALD delivery line is described. This implementation of TDLAS, which utilizes a near-infrared distributed-feedback diode laser and wavelength modulation spectroscopy, provides measurements of water partial pressure on a timescale comparable to or shorter than the timescale of the gas dynamics in typical ALD systems. Depending on the degree of signal averaging, this TDLAS system was capable of measuring the water partial pressure with a detection limit in the range of ∼0.80 to ∼0.08 Pa. The utility of this TDLAS scheme was demonstrated by using it to identify characteristics of a representative water delivery system that otherwise would have been difficult to predict. Those characteristics include (1) the magnitude and time dependence of the pressure transient that can occur during water injection, and (2) the dependence of the steady-state water partial pressure on the carrier gas flow rate and the setting of the water ampoule flow restriction.

42 ENGINEERING↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

SU-E-J-81: Interplay Effect in Non-Gated Dynamic Treatment Delivery of a Lung Phantom with Simulated Respiratory Motion

Purpose: To quantify the interplay effect in non-gated VMAT external beam delivery using realistic, clinically relevant 3D motion in an anthropomorphic lung phantom, and to determine if adding margins is sufficient to account for motion or if gating is required in all cases. Methods: A 4D motion stage was used to move a Virtual Water (VW) lung target containing a piece of radiochromic EBT3 film in an anthropomorphic chest phantom. A five-arc stereotactic body radiation therapy (SBRT) treatment was planned using a CT scan of the phantom in its stationary position, using planning parameters chosen to push the optimizer to achieve a highly-modulated plan. Two scenarios were delivered using a Varian TrueBeam: the first was delivered with the phantom and target both stationary and the second was delivered with the phantom stationary but the target moving in a realistic, irregular 3D elliptical pattern. A single piece of 4×4 cm{sup 2} film was used per fraction, located in the central coronal plane of the target. Film was calibrated on a 6 MV beam with dose values from 0.20 to 20 Gy. Results: Preliminary test films were analyzed in ImageJ and MatLab software. Dose maps were calculated on a central region of interest (ROI) delineated on both the motion-induced and stationary films. Both static and dynamic film dose maps agreed with planning values within acceptable uncertainty. Conclusion: Including a large number of arcs in a clinically realistic SBRT treatment could reduce the effect of motion interplay due to averaging. Because all clinics do not employ multiple arcs for SBRT lung treatments, it is still important to consider the effects of motion on treatment delivery. Further analysis on the treatment films, as well as a broader investigation other planning parameters, will be conducted.

60 APPLIED LIFE SCIENCES↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-236: Feasibility of Using Infrared Imaging to Verify the Accuracy of the Radiotherapy Delivery

Purpose: To assess whether infrared imaging can be used to verify the accuracy of the radiation treatment delivery. Methods: Radiation treatment induced skin reactions include acute changes (erythema and pigmentation) and chronic changes (telangiectasia and ulceration). Thermal imaging can detect these reactions before they become visible. A thermal camera with infrared spectral band 7.5 μm to 14 μm, and temperature measurement range from −20 °C to +150 °C and accuracy of ±2 °C was used. Beams-eye-view images were taken by the end of each treatment for a head and neck patient. The temperature changes of three points were monitored throughout the treatment course, including two points in the field (canthus and vessel) and one point outside of the field. The thermal images were warped and registered to the corresponding planning CT skin rendering. Dose map was exported from the treatment planning system and warped and registered to the planning CT skin rendering as well. The correlation between these two warped and registered images was calculated. The time spent to take the images was recorded. Results: The temperatures of the two points inside the field were always higher than the temperature of the point outside of the field. The temperature inside the field tended to increase as more fractions delivered to the patient. A correlation of 0.90 was found between the registered thermal image and the 3D dose map. On average, half minute was needed to take the images after each treatment. Conclusion: Thermal imaging can monitor the temperature variations of the skin, and the temperatures were proportional to the dose map. It can therefore potentially be an inexpensive and non-ionization tool to verify the accuracy of the radiation treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing functions which by-pass human error avenues.

60 APPLIED LIFE SCIENCES↗

SU-E-T-335: Transit Dosimetry for Verification of Dose Delivery Using Electronic Portal Imaging Device (EPID)

Purpose: To evaluate the effectiveness of transit dose, measured with an electronic portal imaging device (EPID), in verifying actual dose delivery to patients. Methods: Plans of 5 patients with lung cancer, who received IMRT treatment, were examined using homogeneous solid water phantom and inhomogeneous anthropomorphic phantom. To simulate error in patient positioning, the anthropomorphic phantom was displaced from 5 mm to 10 mm in the inferior to superior (IS), superior to inferior (SI), left to right (LR), and right to left (RL) directions. The transit dose distribution was measured with EPID and was compared to the planed dose using gamma index. Results: Although the average passing rate based on gamma index (GI) with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 94.34 % for the transit dose with homogeneous phantom, it was reduced to 84.63 % for the transit dose with inhomogeneous anthropomorphic phantom. The Result also shows that the setup error of 5mm (10mm) in IS, SI, LR and SI direction can Result in the decrease in values of GI passing rates by 1.3% (3.0%), 2.2% (4.3%), 5.9% (10.9%), and 8.9% (16.3%), respectively. Conclusion: Our feasibility study suggests that the transit dose-based quality assurance may provide information regarding accuracy of dose delivery as well as patient positioning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-374: Sensitivity of ArcCHECK to Tomotherapy Delivery Errors: Dependence On Analysis Technique

Purpose: ArcCHECK (Sun Nuclear) is a cylindrical diode array detector allowing three-dimensional sampling of dose, particularly useful in treatment delivery QA of helical tomotherapy. Gamma passing rate is a common method of analyzing results from diode arrays, but is less intuitive in 3D with complex measured dose distributions. This study explores the sensitivity of gamma passing rate to choice of analysis technique in the context of its ability to detect errors introduced into the treatment delivery. Methods: Nine treatment plans were altered to introduce errors in: couch speed, gantry/sonogram synchronization, and leaf open time. Each plan was then delivered to ArcCHECK in each of the following arrangements: “offset,” when the high dose area of the plan is delivered to the side of the phantom so that some diode measurements will be on the order of the prescription dose, and “centered,” when the high dose is in the center of the phantom where an ion chamber measurement may be acquired, but the diode measurements are in the mid to low-dose region at the periphery of the plan. Gamma analysis was performed at 3%/3mm tolerance and both global and local gamma criteria. The threshold of detectability for each error type was calculated as the magnitude at which the gamma passing rate drops below 90%. Results: Global gamma criteria reduced the sensitivity in the offset arrangement (from 2.3% to 4.5%, 8° to 21°, and 3ms to 8ms for couch-speed decrease, gantry-error, and leaf-opening increase, respectively). The centered arrangement detected changes at 3.3%, 5°, and 4ms with smaller variation. Conclusion: Each arrangement has advantages; offsetting allows more sampling of the higher dose region, while centering allows an ion chamber measurement and potentially better use of tools such as 3DVH, at the cost of positioning more of the diodes in the sometimes noisy mid-dose region.

60 APPLIED LIFE SCIENCES↗

MO-C-BRD-01: SBRT I: Overview of Simulation, Planning, and Delivery

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. Treatment planning of SBRT is characterized by precise target volume delineation, highly conformal dose distribution, sharp dose gradient outside the target volume, and meticulous tumor motion management. Stringent dose volume constraints of SBRT require the treatment planning to be highly personalized. Not only the complete patient's medical information (anatomy, tumor size/shape/location/motion, breathing pattern, health status) should be taken into consideration during planning, but also a wide range of factors including imaging techniques (imaging modality, breathing control, immobilization, patient position, etc.), treatment planning techniques (3D-conformal, dynamic conformal arcs, IMRT, VMAT, etc.), image guidance techniques (CBCT, orthogonal X-Ray, fiducial marker tracking, fluoroscopy, etc.), and delivery techniques (FFF, gating, tracking, etc.). In addition, potential pitfalls may exist in SBRT techniques and processes, such as target volume error in 4DCT and image registration error in image guidance. How to manage these affecting factors to achieve optimal, personalized SBRT treatment plans remains a great challenge. In this proposal, we will review technologies, share experiences, and discuss strategies concerning SBRT simulation, planning, and delivery. Learning Objectives: Understand requirements and challenges of SBRT treatment planning Discuss information-driven strategies of developing optimal SBRT plans Discuss practical considerations and potential pitfalls of SBRT treatment planning.

60 APPLIED LIFE SCIENCES↗

WE-D-17A-03: Improvement of Accuracy of Spot-Scanning Proton Beam Delivery for Liver Tumor by Real-Time Tumor-Monitoring and Gating System: A Simulation Study

Purpose: To improve the accuracy of spot-scanning proton beam delivery for target in motion, a real-time tumor-monitoring and gating system using fluoroscopy images was developed. This study investigates the efficacy of this method for treatment of liver tumors using simulation. Methods: Three-dimensional position of a fiducial marker inserted close to the tumor is calculated in real time and proton beam is gated according to the marker's distance from the planned position (Shirato, 2012). The efficient beam delivery is realized even for the irregular and sporadic motion signals, by employing the multiple-gated irradiations per operation cycle (Umezawa, 2012). For each of two breath-hold CTs (CTV=14.6cc, 63.1cc), dose distributions were calculated with internal margins corresponding to freebreathing (FB) and real-time gating (RG) with a 2-mm gating window. We applied 8 trajectories of liver tumor recorded during the treatment of RTRT in X-ray therapy and 6 initial timings. Dmax/Dmin in CTV, mean liver dose (MLD), and irradiation time to administer 3 Gy (RBE) dose were estimated assuming rigid motion of targets by using in-house simulation tools and VQA treatment planning system (Hitachi, Ltd., Tokyo). Results: Dmax/Dmin was degraded by less than 5% compared to the prescribed dose with all motion parameters for smaller CTV and less than 7% for larger CTV with one exception. Irradiation time showed only a modest increase if RG was used instead of FB; the average value over motion parameters was 113 (FB) and 138 s (RG) for smaller CTV and 120 (FB) and 207 s (RG) for larger CTV. In RG, it was within 5 min for all but one trajectory. MLD was markedly decreased by 14% and 5–6% for smaller and larger CTVs respectively, if RG was applied. Conclusions: Spot-scanning proton beam was shown to be delivered successfully to liver tumor without much lengthening of treatment time. This research was supported by the Cabinet Office, Government of Japan and the Japan Society for the Promotion of Science (JSPS) through the Funding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program), initiated by the Council for Science and Technology Policy (CSTP)

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 06: An EPID-based 3D patient dose verification method for SBRT-VMAT delivery

Purpose: Stereotactic body radiation therapy (SBRT) delivered via volumetric modulated arc therapy (VMAT) can strongly benefit from an in vivo patient dose verification due to the large doses per fraction. Electronic portal imaging devices (EPIDs) can be utilized as a patient dose dosimeter. In this work we present a physics-based model which utilizes on-treatment EPID images to reconstruct the dose delivered to an anthropomorphic phantom during SBRT-VMAT delivery. Methods: An SBRT linac beam was modeled using Monte Carlo methods and verified with measured data. Our dose reconstruction model back-projects EPID measured focal fluence upstream of the patient and adds a predicted extra-focal fluence component. This fluence is forward projected onto the patient's density matrix and convolved with dose kernels to calculate dose. The model was validated for two prostate, three lung, and two spine SBRT-VMAT treatments. Results were compared to the treatment planning system's calculation. Results: 2%/2 mm chi comparison calculations gave pass rates for the whole volume, infield, and high dose region respectively, and no lower than: 98%, 95%, 99% for the prostate plans, 99%, 92%, 85% for the lung plans, and 91%, 85%, 81% for the spine plans. A 3%/3mm calculation gave pass rates no lower than 99%, 94%, and 90% for all dose regions for the prostate, lung, and spine respectively. Conclusions: We have developed a physics-based model which calculates delivered dose to phantom (or patient) for SBRT-VMAT delivery using on treatment EPID images. The accuracy of the results has allowed us to test this model clinically.

60 APPLIED LIFE SCIENCES↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-P-14: Dosimetric Effects of Magnetic Field in MRI-Guided Radiation Therapy Delivery for Breast Cancer

Purpose: MRI-guided radiation therapy (RT) delivery would be beneficial for breast irradiation. The electron return effect due to the presence of a transverse magnetic field (TMF) may cause dosimetric issues on dose on skin and at the lung-tissue interface. The purpose of this study is to investigate these issues. Methods: IMRT plans with tangential beams and VMAT plans with 200 degree arcs to cover ipsilateral breast were generated for 10 randomly selected breast cancer cases using a research planning system (Monaco, Elekta) utilizing Monte Carlo dose calculation with or without a TMF of 1.5 T. Plans were optimized to deliver uniform dose to the whole breast with an exclusion of 5 mm tissue under the skin (PTV-EVAL). All four plans for each patient were re-scaled to have the same PTV-EVAL volume to receive the same prescription dose. The skin is defined as the first 5 mm of ipsilateral-breast tissue, plus extensions in the surrounding region. Results: The presence of 1.5 T TMF resulted in (1)increased skin dose, with the mean and maximum skin dose increase of 5% and 9%, respectively; (2) similar dose homogeneity within the PTV-EVAL; (3) the slightly improved (3%) dose homogeneity in the whole breast; (4) Averages of 9 and 16% increases in V5 and V20, respectively, for ipsilateral lung; and (5) increased the mean heart dose by 34%. VMAT plans don’t improve whole breast dose uniformity as compared that to the tangential plans. Conclusion: The presence of transverse magnetic field in MRI-guided RT delivery for whole breast irradiation can Result in slightly improved dose homogeneity in the whole breast, increased dose to the ipsilateral lung, heart, and skin. Plan optimization with additional specific dose volume constraints may eliminate/reduce these dose increases. This work is partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-110: An Investigation On Monitor Unit Threshold and Effects On IMPT Delivery in Proton Pencil Beam Planning System

Purpose: An approved proton pencil beam scanning (PBS) treatment plan might not be able to deliver because of existed extremely low monitor unit per beam spot. A dual hybrid plan with higher efficiency of higher spot monitor unit and the efficacy of less number of energy layers were searched and optimized. The range of monitor unit threshold setting was investigated and the plan quality was evaluated by target dose conformity. Methods: Certain limitations and requirements need to be checks and tested before a nominal proton PBS treatment plan can be delivered. The plan needs to be met the machine characterization, specification in record and verification to deliver the beams. Minimal threshold of monitor unit, e.g. 0.02, per spot was set to filter the low counts and plan was re-computed. Further MU threshold increment was tested in sequence without sacrificing the plan quality. The number of energy layer was also alternated due to elimination of low count layer(s). Results: Minimal MU/spot threshold, spot spacing in each energy layer and total number of energy layer and the MU weighting of beam spots of each beam were evaluated. Plan optimization between increases of the spot MU (efficiency) and less energy layers of delivery (efficacy) was adjusted. 5% weighting limit of total monitor unit per beam was feasible. Scarce spreading of beam spots was not discouraging as long as target dose conformity within 3% criteria. Conclusion: Each spot size is equivalent to the relative dose in the beam delivery system. The energy layer is associated with the depth of the targeting tumor. Our work is crucial to maintain the best possible quality plan. To keep integrity of all intrinsic elements such as spot size, spot number, layer number and the carried weighting of spots in each layer is important in this study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-115: Analysis of Patient Specific QA for VMAT by Disease Site and Planning-Delivery System Using the ScandiDos Delta4 Phantom

Purpose: To evaluate patient specific quality assurance (PSQA) for the delivery of volumetric modulated arc therapy (VMAT) by disease site. To compare planning-delivery system (PDS) PSQA pass rates in a dual vendor institution. Methods: PSQA is performed for VMAT plans using a ScandiDos Delta4 phantom. Verification plans are calculated using Varian Eclipse and Elekta Monaco treatment planning systems (TPS) for patients treated using Varian Truebeam and Elekta linear accelerators respectively. Individual arcs are delivered to the Delta4 phantoms and assessed using the gamma index pass criterion(3% Dose Deviation(DD%), 3mm Distance to Agreement(DTA),10% dose threshold and 90% gamma index). Results: A total of 287 VMAT plans and 680 arcs were analyzed. The passing rates for VMAT QA plans were 95% and 98% for head/neck and pelvis/prostate plans respectively, and 100% for chest/abdomen, spine, lung Stereotactic Body Radiotherapy (SBRT) and Stereotactic Radiosurgery(SRS) plans. Average gamma indices were: (99 ± 2) % for pelvis/prostate, chest/abdomen and lung SBRT plans, (97 ± 4) % for head and neck plans and (98 ± 3) % for spine plans. The average DD% and DTA pass rates ranged from 82% to 90% and 98% to 99% respectively for plans in different disease sites. Paired t-test analysis (two tails) indicated no significant differences in the gamma indices between plans delivered using different PDS; the P values were: 0.08, 0.45, and 0.94 for lung SBRT, head/neck and pelvis/prostate plans respectively. The statistical power for comparing PDS in different disease sites with an alpha of 0.05 is 1. Conclusion: The Gamma indices based on 3% DD%, 3 mm DTA and 10% dose threshold for the VMAT QA plans in all disease sites were well above 90%, suggesting the possibility of using a more stringent PSQA criterion. No significant differences were observed in the QA of VMAT plans delivered using different PDS.

60 APPLIED LIFE SCIENCES↗

SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

60 APPLIED LIFE SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗