Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

LARP LHC 4.8 GHZ Schottky System Initial Commissioning with Beam

The LHC Schottky system consists for four independent 4.8 GHz triple down conversion receivers with associated data acquisition systems. Each system is capable of measuring tune, chromaticity, momentum spread in either horizontal or vertical planes; two systems per beam. The hardware commissioning has taken place from spring through fall of 2010. With nominal bunch beam currents of 10{sup 11} protons, the first incoherent Schottky signals were detected and analyzed. This paper will report on these initial commissioning results. A companion paper will report on the data analysis curve fitting and remote control user interface of the system. The Schottky system for the LHC was proposed in 2004 under the auspices of the LARP collaboration. Similar systems were commissioned in 2003 in the Fermilab Tevatron and Recycler accelerators as a means of measuring tunes noninvasively. The Schottky detector is based on the stochastic cooling pickups that were developed for the Fermilab Antiproton Source Debuncher cooling upgrade completed in 2002. These slotted line waveguide pickups have the advantage of large aperture coupled with high beam coupling characteristics. For stochastic cooling, wide bandwidths are integral to cooling performance. The bandwidth of slotted waveguide pickups can be tailored by choosing the length of the pickup and slot spacing. The Debuncher project covered the 4-8 GHz band with eight bands of pickups, each with approximately 500 MHz of bandwidth. For use as a Schottky detector, bandwidths of 100-200 MHz are required for gating, resulting in higher transfer impedance than those used for stochastic cooling. Details of hardware functionality are reported previously.

43 PARTICLE ACCELERATORS↗

Flight test report of the NASA icing research airplane: Performance, stability, and control after flight through natural icing conditions

Flight test results are presented documenting the effect of airframe icing on performance and stability and control of a NASA DHC-6 icing research aircraft. Kohlman System Research, Inc., provided the data acquisition system and data analysis under contract to NASA. Performance modeling methods and MMLE techniques were used to determine the effects of natural ice on the aircraft. Results showed that ice had a significant effect on the drag coefficient of the aircraft and a modest effect on the MMLE derived longitudinal stability coefficients (code version MMLE). Data is also presented on asymmetric power sign slip maneuvers showing rudder floating characteristics with and without ice on the vertical stabilizer.

Jordan, J. L.↗

The Instrument Test Dewar (ITD): Testing satellite instruments at 1.5 K

The Instrument Test Dewar (ITD) is a cryogenic facility designed and built to test Cosmic Background Explorer (COBE) satellite instruments at 1.5 K. The facility provides a high vacuum and thermal environment with payload thermal, electrical and optical interfaces. There are two concentric vacuum spaces which are not hermitically sealed. The instrument vacuum space is 81.28 cm by 243.84 cm and is cooled by an LHe shroud. The guard vacuum space surrounds an LN2 shroud. There are two separate cryosorption pumping systems and a mechanical LHe pumping system. The data acquisition systems provide payload and housekeeping data. There have been various problems with the facility, and changes and improvements have been made to assure optimum test conditions. COBE instrument testing has been completed on structural, thermal model hardware and the protoflight units.

Milam, Laura J.↗

A new approach for data acquisition at the JPL space simulators

In 1990, a personal computer based data acquisition system was put into service for the Space Simulators and Environmental Test Laboratory at the Jet Propulsion Laboratory (JPL) in Pasadena, California. The new system replaced an outdated minicomputer system which had been in use since 1980. This new data acquisition system was designed and built by JPL for the specific task of acquiring thermal test data in support of space simulation and thermal vacuum testing at JPL. The data acquisition system was designed using powerful personal computers and local-area-network (LAN) technology. Reliability, expandability, and maintainability were some of the most important criteria in the design of the data system and in the selection of hardware and software components. The data acquisition system is used to record both test chamber operational data and thermal data from the unit under test. Tests are conducted in numerous small thermal vacuum chambers and in the large solar simulator and range in size from individual components using only 2 or 3 thermocouples to entire planetary spacecraft requiring in excess of 1200 channels of test data. The system supports several of these tests running concurrently. The previous data system is described along with reasons for its replacement, the types of data acquired, the new data system, and the benefits obtained from the new system including information on tests performed to date.

Fisher, Terry C.↗

Performance Enhancement of the RatCAP Awake Rate Brain PET System

The first full prototype of the RatCAP PET system, designed to image the brain of a rat while conscious, has been completed. Initial results demonstrated excellent spatial resolution, 1.8 mm FWHM with filtered backprojection and <1.5 mm FWHM with a Monte Carlo based MLEM method. However, noise equivalent countrate studies indicated the need for better timing to mitigate the effect of randoms. Thus, the front-end ASIC has been redesigned to minimize time walk, an accurate coincidence time alignment method has been implemented, and a variance reduction technique for the randoms is being developed. To maximize the quantitative capabilities required for neuroscience, corrections are being implemented and validated for positron range and photon noncollinearity, scatter (including outside the field of view), attenuation, randoms, and detector efficiency (deadtime is negligible). In addition, a more robust and compact PCI-based optical data acquisition system has been built to replace the original VME-based system while retaining the linux-based data processing and image reconstruction codes. Finally, a number of new animal imaging experiments have been carried out to demonstrate the performance of the RatCAP in real imaging situations, including an F-18 fluoride bone scan, a C-11 raclopride scan, and a dynamic C-11 methamphetamine scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DACS II - A distributed thermal/mechanical loads data acquisition and control system

A distributed data acquisition and control system has been developed for the NASA Flight Loads Research Facility. The DACS II system is composed of seven computer systems and four array processors configured as a main computer system, three satellite computer systems, and 13 analog input/output systems interconnected through three independent data networks. Up to three independent heating and loading tests can be run concurrently on different test articles or the entire system can be used on a single large test such as a full scale hypersonic aircraft. Thermal tests can include up to 512 independent adaptive closed loop control channels. The control system can apply up to 20 MW of heating to a test specimen while simultaneously applying independent mechanical loads. Each thermal control loop is capable of heating a structure at rates of up to 150 F per second over a temperature range of -300 to +2500 F. Up to 64 independent mechanical load profiles can be commanded along with thermal control. Up to 1280 analog inputs monitor temperature, load, displacement and strain on the test specimens with real time data displayed on up to 15 terminals as color plots and tabular data displays. System setup and operation is accomplished with interactive menu-driver displays with extensive facilities to assist the users in all phases of system operation.

Zamanzadeh, Behzad↗

Idaho National Laboratory Data Acquisition And Processing System

The INLDAS data acquisition and processing system is designed to develop prototype measurements and real-time processing techniques. The INLDAS hardware and firmware currently consists of National Instruments • NI-DAQmx 14.1 • cDAQ-9184 • 9205 • 9211 INLDAS can perform of standard data acquisition functions as well as novel functions and real-time processing algorithms. There are 3 acquisition modes to choose from: • Continuous mode runs when the user hits start, processing data and logging it to file • SWTrigger mode waits for one or more predefined triggers before acquiring data. It will buffer data as well, so it can record data that happened shortly before the trigger • Wakeup mode waits on predefined timers. When a time goes off, it acquires a preset amount of data There are also 3 Data Processing Modes • Normal mode does no processing besides the rolling average • FFT Mode Performs an FFT on incoming data every time the time window has elapsed • STFFT mode

Smith, JamesA↗

Passive Noise Analysis for Advanced Tamper Indication. End of Year Report 2015

Idaho National Laboratory (INL) is part of a multi-lab project assessing front-end electronics for unattended measurement (FEUM) being developed for the International Atomic Energy Agency (IAEA) unattended systems. The FEUM development activity provides an opportunity to address tampering detection between FEUM and the detector, signal integrity from FEUM to the data acquisition systems, and data validity – long-standing challenges for the IAEA. This report summarizes the INL activities in Fiscal Year (FY) 2015 to characterize and test passive noise analysis as a potential tamper-indicating approach for implementation into FEUM or as a stand-alone method. The project’s primary objectives in FY-15 were to (1) determine detectable tamper scenarios using four pre-amplifier/detector systems, (2) perform tests of tampering scenarios with three common cable types used by the IAEA, (3) separate radio-frequency-induced events from inherent effect by means of an anechoic chamber, and (4) perform tests at an industrial facility. General conclusions were reached in several areas.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detection Of Special Nuclear Materials Tagged Neutrons

In order to detect Special Nuclear Materials (SNM) in unattended luggage or cargo containers in the field of homeland security, fissions are induced by 14 MeV neutrons produced by an associated particle DT neutron generator, and prompt fission particles correlated with tagged neutron are detected by plastic scintillators. SMN produce high multiplicity events due to induced fissions, whereas nonnuclear materials produce low multiplicity events due to cross-talk, (n,2n) or (n,n'γ) reactions. The data acquisition electronics is made of compact FPGA boards. The coincidence window is triggered by the alpha particle detection, allowing to tag the emission date and direction of the 14 MeV interrogating neutron. The first part of the paper presents experiment vs. calculation comparisons to validate MCNP-PoliMi simulations and the post-processing tools developed with the data analysis framework ROOT. Measurements have been performed using different targets (iron, lead, graphite), first with small plastic scintillators (10 x 10 x 10 cm{sup 3}) and then with large detectors (10 x 10 x 100 cm{sup 3}) to demonstrate that nuclear materials can be differentiated from nonnuclear dense materials (iron, lead) in iron and wood matrixes. A special attention is paid on SNM detection in abandoned luggage. In the second part of the paper, the performances of a cargo container inspection system are studied by numerical simulation, following previous work reported in. Detectors dimensions and shielding against the neutron generator background are optimized for container inspection. Events not correlated to an alpha particle (uncorrelated background), counting statistics, time and energy resolutions of the data acquisition system are all taken into account in a realistic numerical model. The impact of the container matrix (iron, ceramic, wood) has been investigated by studying the system capability to detect a few kilograms of SNM in different positions in the cargo container, within 10 min acquisitions. (authors)

36 MATERIALS SCIENCE↗

A multiprocessor airborne lidar data system

A new multiprocessor data acquisition system was developed for the existing Airborne Oceanographic Lidar (AOL). This implementation simultaneously utilizes five single board 68010 microcomputers, the UNIX system V operating system, and the real time executive VRTX. The original data acquisition system was implemented on a Hewlett Packard HP 21-MX 16 bit minicomputer using a multi-tasking real time operating system and a mixture of assembly and FORTRAN languages. The present collection of data sources produce data at widely varied rates and require varied amounts of burdensome real time processing and formatting. It was decided to replace the aging HP 21-MX minicomputer with a multiprocessor system. A new and flexible recording format was devised and implemented to accommodate the constantly changing sensor configuration. A central feature of this data system is the minimization of non-remote sensing bus traffic. Therefore, it is highly desirable that each micro be capable of functioning as much as possible on-card or via private peripherals. The bus is used primarily for the transfer of remote sensing data to or from the buffer queue.

Wright, C. W.↗

Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) Field Campaign Report

The scientific focus here is interagency collaboration to support a National Aeronautics and Space Administration (NASA)-sponsored 2023 field campaign: Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS). IMPACTS objectives are to provide observations critical to understanding the mechanisms of snowband formation, organization, and evolution; study how the microphysical characteristics and likely growth mechanisms of snow particles vary across snowbands; and improve snowfall remote-sensing interpretation and modeling to significantly advance predictive capabilities. The relevance to The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility's mission was to support the Interagency Council for Advancing Meteorological Services (ICAMS)’ objectives to enhance communication and coordination, and promote sharing, within and across agencies. NASA therefore requested to borrow ARM’s two-dimensional stereo probe (2DS) for possible use during the 2023 IMPACTS project. Additionally, this use of the 2DS could improve understanding of ARM 2DS measurements collected on previous field campaigns. The plan was to have the 2DS available for possible backup deployment on the NASA Lockheed Orion P-3 aircraft during the 2023 IMPACTS field project. NASA has a 2DS probe and the ARM 2DS is a hot swappable probe in case the project's 2DS fails. The 2DS is a critical probe and we had issues during a 2022 field project that prevented us from obtaining 2DS data on several flights. Hence, we wanted a hot swappable 2DS on stand-by. We have a data acquisition system, along with a backup data acquisition system for the 2DS, so we only needed the 2DS probe. David Delene was responsible for the use of the 2DS on the NASA P-3 aircraft. He has experience deploying the 2DS on several aircraft, including previously on the NASA P-3 in 2022. The team ensured that the aircraft wiring and deployment of the 2DS were completed correctly for the ARM 2DS.

54 ENVIRONMENTAL SCIENCES↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

InstrumentationPod (IPOD) User Guide

This document describes the Instrumentation Pod (IPOD) and its operation and use. The IPOD is a low-power detector system comprising a 3He tube with preamp for neutron detection, a microcontroller-based data acquisition system, a GPS receiver for locationdetermination and time-synchronization, and power filtering and protection. The IPOD is intended to be bolted to the top of Dual-Use Casks stored at Baikal-1 in Kazakhstan in order to maintain continuity of knowledge of the materials stored within the cask. The data acquisition system receives pulses from the neutron-detection preamp, combines this information with other sensor data, and stores the result on two SD cards that are part of the data acquisition system. Firmware in the data acquisition system controls collection and storing of the data and enables configuration of the acquisition parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

DDS-Suite - A Dynamic Data Acquisition, Processing, and Analysis System for Wind Tunnel Testing

Wind Tunnels have optimized their steady-state data systems for acquisition and analysis and even implemented large dynamic-data acquisition systems, however development of near real-time processing and analysis tools for dynamic-data have lagged. DDS-Suite is a set of tools used to acquire, process, and analyze large amounts of dynamic data. Each phase of the testing process: acquisition, processing, and analysis are handled by separate components so that bottlenecks in one phase of the process do not affect the other, leading to a robust system. DDS-Suite is capable of acquiring 672 channels of dynamic data at rate of 275 MB / s. More than 300 channels of the system use 24-bit analog-to-digital cards and are capable of producing data with less than 0.01 of phase difference at 1 kHz. System architecture, design philosophy, and examples of use during NASA Constellation and Fundamental Aerodynamic tests are discussed.

Burnside, Jathan J.↗

Advanced Biotelemetry Systems for Space Life Sciences

The Sensors 2000! Program at NASA-Ames Research Center is developing an Advanced Biotelemetry System (ABTS) for Space Life Sciences applications. This modular suite of instrumentation is planned to be used in operational spaceflight missions, ground-based research and development experiments, and collaborative, technology transfer and commercialization activities. The measured signals will be transmitted via radio-frequency (RF), electromagnetic or optical carriers and direct-connected leads to a remote ABTS receiver and data acquisition system for data display, storage, and transmission to Earth. Intermediate monitoring and display systems may be hand held or portable, and will allow for personalized acquisition and control of medical and physiological data.

Hines, John W.↗