Data-Driven Correlation of Cyber and Physical Anomalies for Holistic System Health Monitoring
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.
This paper presents a systems analysis approach to characterizing the risk of a Smart Grid to a load-drop attack. A characterization of the risk is necessary for the design of detection and remediation strategies to address the consequences of such attacks. Using concepts from systems health management and system engineering, this work (a) first identifies metrics that can be used to generate constraints for security features, and (b) lays out an end-to-end integrated methodology using separate network and power simulations to assess system risk. We demonstrate our approach by performing a systems-style analysis of a load-drop attack implemented over the AMI subsystem and targeted at destabilizing the underlying power grid.
Modernization of energy systems has led to in- creased interactions among multiple critical infrastructures and diverse stakeholders making the challenge of operational decision making more complex and at times beyond cognitive capabilities of human operators. The state-of-the-art machine learning and deep learning approaches show promise of supporting users with complex decision-making challenges, such as those occurring in our rapidly transforming cyber-physical energy systems. However, successful adoption of data-driven decision support technology for critical infrastructure will be dependent on the ability of these technologies to be trustworthy and contextually interpretable. In this paper, we investigate the feasibility of implementing XAI for interpretable detection of cyberattacks in the energy system. Leveraging a proof-of-concept simulation use case of detection of a data falsification attack on a photovoltaic system using XGBoost algorithm, we demonstrate how Local Interpretable Model-Agnostic Explanations (LIME), a flavor XAI approach, can help provide contextual and actionable interpretation of cyberattack detection.
Establish operational critical infrastructure research environment with focus on control systems security Continue enhancement of critical infrastructure cyber-physical interdependency analysis and knowledge management capabilities
Cyber-physical testing is a class of experimental methods in which a system is partitioned into physical and numerical components to study its overall behavior. Transfer systems are typically needed to capture relevant interactions by enforcing appropriate interface conditions between the physical and numerical portions. While cyber-physical testing is often performed using lumped-parameter systems, thermomechanical cyber-physical testing requires the use of thermal actuators as transfer systems to apply a thermal condition over a spatially distributed region or surface. Thus, the interactions between the numerical and physical components are of a distributed nature, i.e., a field rather than point values. In this paper, we develop and experimentally validate a state observer for temperature fields to enable thermomechanical cyber-physical testing. The state observer provides continuous estimates of temperature over a surface of the thermal actuator using only temperature measurements at discrete locations. The estimated temperature field is then leveraged to account for localized mechanical defects in the interface condition. The method consists of building a digital replica of one portion of the control plant. By imposing defects in the digital replica it is used to generate and output the response of a thermal load pattern that represents that of a physical system with mechanical defects.
Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.
Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.
In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.
The main goal of the project is to develop an AI-based process layer cybersecurity suite for detection, isolation and mitigation of cyber-attack effects on operation of building energy management systems (BEMS). The following constituent key technologies were developed under the program towards fulfilling the program objectives: (1) developed a high fidelity BEMS testbed for generation of training data and validation of developed technologies; (2) developed a physics informed ML based attack detection and localization module (ADL) capable of detecting high impact stealthy attacks (HISA - attacks causing 30% energy utilization but no immediate visible impact otherwise) with 98% accuracy; (3) developed a methodology to determine ’representative days’ to limit the data required for training; (4) developed a virtual sensing system that can reconstruct affected sensors with 10% error for the same HISA set; (5) developed a resilient model predictive control system that can continue operation of the BEMS without jeopardizing stability for the HISA set; and (6) integrated and deployed all the constituent modules and demonstrated the efficacy of the technology in real-time in a hardware in loop simulation.
The secure transport of natural gas through North American pipelines is vital for both home and industrial purposes. GE in collaboration with Baker Hughes and Idaho National Laboratory, completed a US Department of Energy grant program to develop a new cyber-physical protection system that monitors the large compressor stations used to boost pressure and maintain proper gas flow. Algorithms were developed to detect the presence of a cyber-attack that impacts the compressor station physical processes, locate the critical functions being manipulated, and potentially neutralize the attack allowing continued operations. The technology was successfully demonstrated at an operating compressor facility located in New York state.
Today’s large-scale Electric Vehicle (EV) infrastructures are heavily dependent on information communication technologies to maintain their operation and to support communication within sub-system components as well as the outside world. These technologies are vulnerable to various cyber and physical threats. Timely identification and mitigation of these threats are critical for improving human safety, avoiding economic losses, and preventing catastrophic system failures. By addressing this, our work presents a ResNet Autoencoder (AE) based Cyber-Physical Anomaly Detection System (Cy-Phy ADS) for detecting anomalies in EV Controller Area Network (CAN) protocol communication. It consists of four main components: Cyber-Physical Feature Extractor, ResNet AE-based Anomaly Detection Framework, Cyber-Physical Health Metric (CPHM), and Visualization Dashboard. The presented framework was trained and tested using CAN data collected from the EV charging system testbed at the Idaho National Laboratory. The presented Cy-Phy ADS compared against six widely used unsupervised anomaly detection algorithms: One Class Support Vector Machine (OCSVM), Variational Autoencoder (VAE), LSTM Autoencoder (LSTM AE), Isolation Forest (IForest), Principle Component Analysis (PCA) and Local Outlier Factor (LOF). Here the presented approach showed the highest accuracy among the compared methods. Further, the proposed approach showed comparable performance in terms of precision, F1, and False positive rate. It also showed the lowest training and inference time compared to the neural network-based baseline algorithms compared against with. Additionally, the Cy-Phy ADS has advantages such as unsupervised training, the ability to provide a holistic metric for system health characterization, and non-linear feature extraction.
Extraterrestrial long-term habitat systems (henceforth referred to as habitat systems) require groundbreaking technological advances to overcome the extreme demands introduced by isolation and challenging environments. A habitat system must operate as intended under continuous disruptive conditions. Designing for the demands that challenging environments will place on habitat systems (e.g., wild temperature fluctuations, galactic cosmic rays, destructive dust, meteoroid impacts, vibrations, and solar particle events) represents one of the greatest challenges in this endeavor. This engineering problem necessitates that we design and manage habitat systems to be resilient. System resilience requires a comprehensive approach that accounts for disruptions through the design process and adapts to them in operation. As the habitat system evolves—growing in physical size, complexity, population, and connectivity—and diversifies in operations, it must continue to be safe and resilient. In this endeavor, we should take advantage of lessons learned in developing civil infrastructure responsive to catastrophic natural hazards, autonomous robotics platforms, smart buildings, cyber-physical testing, complex systems, and diagnostics and prognostics for intelligent health management. This study highlights the importance of system resilience and cyber-physical testing to address the grand challenge of developing habitat systems.
As devices and systems continue to modernize and adopt integrated circuits, the use of cyber technology to deploy an application is the expectation. This deployment through cyber assets brings new cyber risk and cybersecurity is the practice of managing this risk. Cyber-risk is constantly changing due to the speed of technology advancement and the changing quality of the adversary. Cyber-Informed Engineering (CIE) mitigates cyber-risk through engineering controls where as the traditional practice of cybersecurity mitigates cyber-risk through cybersecurity controls. By clearly defining the cyber-physical boundary, engineering controls and cybersecurity controls can clearly demonstrate their complementary nature to provide layered defenses and successfully mitigate cyber-risk through independent controls. In this paper, a layered model of device decomposition of the the cyber-physical boundary is presented to provide clarity where engineering controls are used to reduce cyber-risk within the physics, functional materials, electronic, or integrated circuit layers and where cybersecurity controls are used to reduce cyber-risk within the machine code and application layers. By implementing both traditional cybersecurity controls and engineering controls, a more holistic approach to cybersecurity is achieved in protecting modern devices and systems, as well as a clear awareness in identifying, documenting, and authorizing the system’s cybersecurity protection scheme is achieved.
Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast and accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.
We propose a generalized framework which performs an optimal partitioning of a limited budget into various organizational sectors in order to improve the cybersecurity of a smart device or component in the Cyber Physical Energy System (CPS). The framework identifies the adversarial threats and possible attack sequences which can be performed to exploit cyber vulnerabilities of the component. Thereafter, we formulate an Mixed Integer Linear Programming (MILP) optimization problem which aims to evaluate the optimal budget partitions in order to minimize the number of highly likely attack sequences. Though we provide results for using the framework in CPES, the proposed methodology can be extended for multiple domains with a set of known adversarial and mitigation actions.
Microgrids rely on communication networks for reliable operation, which makes them inherently vulnerable to cyberattacks. Such attacks can destabilise system dynamics and drive states away from their nominal operating trajectories. Although several physics-informed and machine learning-based strategies have been developed to counter these threats, the rapidly evolving cyber landscape enables adversaries to bypass static defences or rules-based mitigation approaches. This paper proposes a dynamic, online-trained and fully decentralised reinforcement learning (RL)-based cyberattack response framework to protect microgrids from evolving cyberattacks. The proposed framework deploys multiple deep Q-networks (DQNs), each associated with a distributed energy resource (DER), to enable localised and adaptive attack mitigation. In this framework, each DQN processes local voltage and frequency measurements—combined with intrusion detection system (IDS) alerts—as observations and rewards to guide decision-making. Extensive simulation studies demonstrate the robustness of the proposed framework under diverse attack scenarios and varying IDS-induced detection delays. Comparative analysis highlights its superiority over existing static or preexisting rules-based mitigation approaches. Finally, we present an analysis that shows the framework's scalability to real-life microgrids with more interacting agents.
Malicious activities on measurements from sensors like Phasor Measurement Units (PMUs) can mislead the control center operator into taking wrong control actions resulting in disruption of operation, financial losses, and equipment damage. In particular, false data attacks initiated during power systems transients caused due to abrupt changes in load and generation can fool the conventional model-based detection methods relying on thresholds comparison to trigger an anomaly. In this paper, we propose a Koopman mode decomposition (KMD) based algorithm to detect and identify false data attacks in real-time. The Koopman modes (KMs) are capable of capturing the nonlinear modes of oscillation in the transient dynamics of the power networks and reveal the spatial embedding of both natural and anomalous modes of oscillations in the sensor measurements. The Koopman-based spatio-temporal nonlinear modal analysis is used to filter out the false data injected by an attacker. The performance of the algorithm is illustrated on the IEEE 68-bus test system using synthetic attack scenarios generated on GridSTAGE, a recently developed multivariate spatio-temporal data generation framework for simulation of adversarial scenarios in cyber-physical power systems.