Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control and Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Marine and Hydrokinetic ToolKit for Data Quality Control and Analysis: Preprint

The ability to handle data is critical at all stages of marine energy (ME) development. The marine hydrokinetic toolkit (MHKiT) is an open-source marine energy software, which includes modules for ingesting, applying quality control, processing, visualizing, and managing data. MHKiT-Python and MHKiT-MATLAB provide robust and verified functions that are needed by the ME community to standardize data processing. Calculations and visualizations adhere to International Electrotechnical Commission (IEC) technical specifications and other guidelines. A resource assessment of NDBC buoy 46050 near PACWAVE is performed using MHKiT and discusses comparisons to the resource assessment provided performed by Dunkel et al.

marine energy↗

The Marine and Hydrokinetic Toolkit (Mhkit) for Data Quality Control and Analysis

The ability to handle data is critical at all stages of marine energy (ME) development. The marine hydrokinetic toolkit (MHKiT) is an open-source marine energy software, which includes modules for ingesting, applying quality control, processing, visualizing, and managing data. MHKiT-Python and MHKiT-MATLAB provide robust and verified functions that are needed by the ME community to standardize data processing. Calculations and visualizations adhere to International Electrotechnical Commission (IEC) technical specifications and other guidelines. A resource assessment of NDBC buoy 46050 near PACWAVE is performed using MHKiT and discusses comparisons to the resource assessment provided performed by Dunkel et al.

marine energy↗

Techniques in performance and efficiency improvements of processors in a cooling system

Embodiments of the present disclosure describe methods, apparatuses, storage media, and systems for Thermal Design Power (TDP) rebalancing among thermally-coupled processors and non-thermally-coupled processors, providing computing efficiency or homogeneity with respect to, including but not limited to, thermal requirements, power consumption, and processor operations. The TDP rebalancing may include implementing management circuitry and configuration control circuitry. Other embodiments may be described and claimed.

Keceli, Fuat↗

Detection of an internal short circuit in a battery

An electrical device comprises a battery cell; a pressure sensor for measuring swelling forces of the battery cell, optionally with voltage, temperature and current sensors, and a battery management system including a controller. The controller executes a program to: (i) determine a reference swelling force corresponding to a reference electrical signal received from the pressure sensor at an earlier reference time, (ii) determine a second swelling force corresponding to a second electrical signal received from the pressure sensor at a later second time, and (iii) determine whether a risk of internal short circuit of the battery cell exists by comparing a reference level of the reference electrical signal and a signal representative of the second electrical signal. When the signal representative of the second electrical signal exceeds the reference level of the reference electrical signal by a threshold amount, a risk of internal short circuit of the cell exists.

Stefanopoulou, Anna G.↗

State of battery health estimation based on swelling characteristics

There is disclosed an electrical device including a battery, and a battery management system. The battery management system includes a controller in electrical communication with a pressure sensor to monitor the state of health of the battery. The controller applies a method for determining the state of health that uses a non-electrical (mechanical) signal of force measurements combined with incremental capacity analysis to estimate the capacity fading and other health indicators of the battery with better precision than existing methods. The pressure sensor may provide the force measurement signal to the controller, which may determine which incremental capacity curve based on force to use for the particular battery. The controller then executes a program utilizing the data from the pressure sensor and the stored incremental capacity curves based on force to estimate the capacity fading and signal a user with the state of health percentage.

Stefanopoulou, Anna G.↗

AmeriFlux FLUXNET-1F US-ARc ARM Southern Great Plains control site- Lamont

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-ARc ARM Southern Great Plains control site- Lamont. This is the FLUXNET version of the carbon flux data for the site US-ARc ARM Southern Great Plains control site- Lamont produced by applying the standard ONEFlux (1F) software. Site Description - The ARM SGP Control site is located in the native tallgrass prairies of the USDA Grazinglands Research Laboratory near El Reno, OK. One of two adjacent 35 ha plots with identical towers, measurements at the US-ARc unburned plot are used as the experimental control. The second plot, US-Arb, was burned on 2005/03/08. Measurement comparisons between the control and burn plot are used to address questions regarding the effects of burning activities on carbon fluxes. The region evaded burning activities for at least 15 years. Current disturbances consist of only light grazing activities.

Torn, Margaret↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

Frequency threshold determination for frequency-responsive load controllers

Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing a Supply Chain Security Program

Amid growing concerns over foreign manufacturing for components and devices deployed in critical energy infrastructure, this research from the national labs will highlight best practices for developing and maintaining a supply chain security program. Tools for asset inventory, tips for developing and maintaining software- and hardware-bills-of-materials (SBOMs and HBOMs), recommended contractual language for vendor agreements, and identification of responsibilities will be shared. We discuss the one-time requirements to enable a successful supply chain security program and the best ways to operationalize this program for maximum impact, including development of robust practices for vulnerability tracking, patch management, and workarounds, with understanding of the reliability and uptime requirements for utilities. The recommendations shared are based on a cyber-informed engineering approach to identification of high-consequence impacts and the engineering controls related to supply chain management that can best mitigate these impacts. This approach allows for prioritization of resources. Additionally, we highlight relative up-front and ongoing costs associated with recommended controls. Viewers will leave with an understanding what a supply chain security program is, and what steps, prioritized for resource-constrained organizations, can build a robust program.

14 SOLAR ENERGY↗

U.S. Department of Energy Office of Legacy Management 2024 Annual Site Inspection and Monitoring Report for Uranium Mill Tailings Radiation Control Act Title I Disposal Sites

This report, in fulfillment of a U.S. Nuclear Regulatory Commission (NRC) license requirement, presents the results of long-term surveillance and maintenance activities conducted by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) in 2024. These activities occurred at the 19 uranium mill tailings disposal sites established under Title I of the Uranium Mill Tailings Radiation Control Act (UMTRCA) and verify that the UMTRCA Title I disposal sites remain in compliance with license requirements and Long-Term Surveillance Plans (LTSPs). Individual chapters for each site are available on the LM public website at https://energy.gov/lm/sites/lm-sites.

54 ENVIRONMENTAL SCIENCES↗

Digital Twin + AI: Control Room of the Future

A digital twin enhances power grid control room operations by providing real-time monitoring, predictive insights, simulation capabilities, remote control, training opportunities, data integration, and decision support. This technology empowers control room operators to effectively manage the grid, optimize performance, and ensure reliable and efficient energy distribution.

control room of the future↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control-Oriented Modeling of Lithium-Ion Batteries

Battery management systems (BMSs), which monitor and optimize performance while ensuring safety, require control-oriented models, i.e., models tailored to the design and implementation of estimation and control algorithms. Physics-based electrochemical models describe detailed battery phenomena, but are too computationally intensive for use in estimation and control applications. Single particle models (SPMs), which retain some of the physics of electrochemical models, are often used for control-oriented battery modeling since they are computationally efficient; however, they are only valid over very low frequency ranges and C-rates. Empirical equivalent circuit models (ECMs) are also used for control-oriented battery modeling since they are computationally efficient and can describe battery behavior over wide frequency ranges; however, they provide no physical understanding of the battery and, therefore, have limited applicability. Further, fractional order terms (e.g., Warburg impedances) are often employed, making the models unwieldy for use in the time domain. This work provides a control-oriented battery model that combines the benefits of SPM and ECM models, while overcoming their limitations. The proposed model incorporates some of the battery physics found in electrochemical models, can easily be used in both the time and frequency domains, and describes battery behavior over its entire frequency range. A linearized single particle model, which incorporates key electrochemical parameters, is used for modeling battery physics at very low frequencies. For low frequencies, integer-order linear systems are used to approximate diffusion physics described by Warburg impedances, and high frequency behavior is modeled by the double layer capacitance effect. The proposed battery model is more computationally efficient than full electrochemical models since it does not require the solution of PDEs, is accurate for a wider frequency range than the SPM considered in this paper, and does not suffer from the unwieldiness and limited applicability of empirical ECMs. Finally, the model is validated in the time and frequency domains via a comparison to pseudo-two-dimensional (P2D) model simulations and experimental data.

25 ENERGY STORAGE↗

Hardware-in-Loop Modules for Testing Automated Ventilator Controllers

Automated ventilator controllers have the potential to simplify oxygen and carbon dioxide management for trauma. In the pre-hospital or military medicine environment, trauma care can be required for prolonged periods by personnel with limited ventilator management training. As such, there is a need for closed-loop control systems that can adapt ventilator management to a complex, ever-changing medical environment. Here, we present a novel hardware-in-loop test platform for the independent troubleshooting and evaluation of oxygen and carbon dioxide automated ventilator management capabilities. The oxygen management system provides an analogue blood oxygen signal that is responsive to the fraction of inspired oxygen and the peak inspiratory pressure ventilator settings. A tested oxygenation controller successfully reached the target oxygen saturation within 5 min. The carbon dioxide removal system integrates with commercial ventilator technology and mimics carbon dioxide generation, lung compliance, and airway resistance while providing an end-tidal carbon dioxide level that is responsive to changes in the tidal volume and respiratory rate settings. A test mechanical ventilator controller was able to regulate EtCO2 regardless of the starting value within 10 min. This highlights the system’s functionality and provides proof-of-concept demonstrations for how the hardware-in-loop test platforms can be used for evaluating closed-loop controller technologies.

Berard, David (ORCID:0000000322863846)↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Network-Aware Distributed Energy Resource Aggregation Framework for Flexible, Cost-Optimal, and Resilient Operation

To efficiently use the ubiquitous behind-the-meter distributed energy resources (DERs) in distribution systems for providing grid services, this paper presents a hierarchical control framework for DER optimal aggregation and control. We first develop a convex optimization model to evaluate the DER flexibility, and then use a convex model-predictive-control based approach to dispatch those DERs. The hierarchical control framework consists of a utility controller, community aggregators and multiple home energy management systems. The flexibility of the DERs is evaluated by each controller in the hierarchy such that the resultant flexibility is feasible given its operational domain. Based on the determined flexibility, the hierarchical controllers then compute optimal setpoints for the DERs to help the distribution system regulate node voltages and provide other distribution grid services. Numerical simulations performed on a model of a real distribution feeder in Colorado, using actual DER data in a residential community demonstrate that the proposed approach can effectively alleviate voltage issues and support resilient operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗