Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary methods for detecting presence of water in a sample include: heating a light source to a predetermined temperature at which the light source emits thermal radiation; placing a sample between the light source and a detector; transmitting the thermal radiation from the light source through the sample and onto the detector; and determining a presence or an absence of water within the sample based on the thermal radiation transmitted onto the detector. Exemplary systems for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗

Serial Moire scanning phase contrast x-ray imaging

Method include emitting x-rays from an x-ray source, directing a first portion of the x-rays through an object grating situated adjacent to an object while the object is scanned relative to the object grating along a scan direction, directing a second portion of the x-rays through the object and subsequently through a detector grating without transmitting through the object grating, wherein the object grating and detector grating are adjacently arranged in a field of view of the x-rays sequentially with respect to each other in the scan direction, and receiving the first portion transmitted through the object and object grating with a first portion of a detector and receiving the second portion transmitted through the object and the detector grating with a second portion of the detector adjacent to the first portion of the detector. Systems are also disclosed, along with related techniques for beam hardening correction.

Miller, Erin A.↗

Contrasting Time-Frequency Representations for Unknown Waveform Detection

In real-world applications like spectrum management and interference detection, dealing with unseen electromagnetic waveforms is critical. Although some methods attempt to simulate open set data using generator models, they face challenges in generating synthetic samples for open set while simultaneously selecting an optimal discriminator for accurate classification. This results in difficulties capturing distinctive features across classes, especially in dynamic scenarios where new classes emerge. To detect unseen waveforms, we propose combining time and frequency domain features with cosine similarity loss to enhance feature distinctiveness and enabling more accurate predictions. This approach efficiently captures more comprehensive information than single-domain representations or approaches without cosine loss. Additionally, our model avoids generic feature vectors by extracting class-specific features during training, resulting in improved class representation. The experiment results show that this combined feature approach with cosine loss outperforms single-domain models and improves accuracy by 10\% over models without cosine loss.

99 - GENERAL AND MISCELLANEOUS↗

Contrasting Time-Frequency Representations for Unknown Waveform Detection

Identifying unseen electromagnetic waveforms is critical for many applications, like interference management, electronic warfare and spectrum management. Traditionally this is done using statistical methods for anomaly detection, which has evolved to deep learning models for identifying the unseen data, formally termed as open set recognition. Some prior methods use a generative model to emulate open set data, which face challenges in generating synthetic samples for open set while simultaneously selecting an optimal discriminator for accurate classification. To alleviate this issue, we propose a discriminative model that effectively combines time and frequency domain features of communication signals for accurate predictions. We further introduce a cosine similarity loss that makes the domain specific features unique to enhance the prediction rate. Additionally, our model avoids generic feature vectors by extracting class-specific features during training, resulting in improved class representation. The experiment results show that this combined feature approach with cosine loss outperforms single-domain models and improves accuracy by 10% over models without cosine loss.

99 - GENERAL AND MISCELLANEOUS↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Mechanisms for an amplified precipitation seasonal cycle in the U.S. West Coast under global warming

The mean precipitation along the U.S. West Coast exhibits a pronounced seasonality change under warming. Here we explore the mechanisms for the seasonality change based on 37 climate models using moisture budget framework. The multi-model simulations show a robust enhancement of wet season precipitation over Washington-Oregon and a sharpened seasonal cycle with a stronger and narrower wet season over California. Both changes are predominantly caused by changes in the mean moisture convergence. Thermodynamic effect due to the divergence of increased moisture dominates the ‘wet-get-wetter’ seasonal enhancement over Washington-Oregon, where the climatological lower tropospheric convergence is strong. In contrast, mean zonal moisture advection due to seasonally-dependent changes in moisture gradient dominates the sharpened wet season over California. The seasonally-dependent changes in zonal moisture gradient originate from the effects of both the climatological and changes of land-sea thermal contrast on the changes in land-sea moisture contrast in different seasons under warming through the nonlinear Clausius–Clapeyron relation. More specifically, the stronger climatological land-sea thermal contrast in winter with warmer ocean than land dominates the change in land-sea moisture contrast, resulting in more moisture increase over ocean than land under warming and hence wet advection to California. However, in fall and spring, the future change of land-sea thermal contrast with larger warming over land than ocean dominates the changes in land-sea moisture contrast, inducing an opposite moisture gradient and hence dry advection to California. The sharpening seasonality adds to the complexity to water resource management in the future.

Dong, Lu↗

Automated Estimation of the DARHT Radiographic Spot Size from Spatially Modulated Images

We wrote a software routine to find local extrema and calculate the contrast in the image for each feature set. The input is a KTO image in the standard DARHT orientation, pre-processed by flat-fielding, dark frame subtraction and de-warping. Table 1 shows contrast results for five contemporaneous DARHT images of the KTO. For some very dense feature sets, contrast measurements are not possible due to a lack of local extrema, and in this case no contrast value is given in the table. Highlighted in bold are the contrast values for each image that bound the threshold C = 0.01. The contrast is varying rapidly enough with spatial frequency that we can interpolate between these values to find an estimate of the spatial frequency at the threshold value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and modelling of the photonic crystal fano structure for all optical switching applications

In this paper, the optical Fano switch based on the 2D slab photonic crystal is analyzed. Switching characteristics are improved by manipulating the Q factors of cavities. Modified device with enhanced Fano resonance has lower energy consumption than other previous optical switches. Results show that, the switching contrast is enhanced while the quality factor has remained in its highest value. Therefore, the typical important trade off between switching contrast and quality factor has vanished in the modified structure. The switching contrast is improved from 7 to 34 db in constant Δλ{sub peak−peak} of 0.3 nm in the modified structure which leads to decreasing the energy consumption of the device. In the previous devices, the maximum reported contrast is about 20 db for Δλ{sub peak−peak} of 0.6 nm. A coupled mode theory for analyzing the structure is developed. The results of finite difference time domain numerical simulation are in good agreement with the theoretical coupled mode theory. Results show that the switching contrast of the modified Fano switch is enhanced two times, consequently the loss is suppressed and the bandwidth is improved.

36 MATERIALS SCIENCE↗

The application of synchrotron micro-computed tomography to characterize the three-dimensional microstructure in irradiated nuclear fuel

This research demonstrated the first time that synchrotron X-ray micro-computed tomography (μ-CT) was utilized to analyze the three-dimensional (3-D) morphology of the microstructure of irradiated nuclear fuel. Both absorption contrast and propagation-based phase contrast enhanced μ-CT techniques were evaluated. Porosity and phase region volumes were determined in neutron irradiated uranium 10 wt.% zirconium (U-10Zr) using propagation-based phase contrast enhanced μ-CT. Volumes were determined by image processing software and algorithms, with the porosity volume subsequently compared to the ASTM E562 method. The 3-D porosity of a small region (~ 8 x 10 5 µm 3 ) located in the intermediate fuel redistribution zone that was removed via a focused ion beam was determined to be 7.2% via image processing. A detailed 3-D analysis of the porosity with respect to volume and morphology was provided. Five growth stages of pore evolution were observed including: nucleation, growth, coalescence, interconnected porosity, and extended/interconnected porosity. Four distinct phase regions were identified, including the pores, via both absorption contrast and propagation-based phase contrast enhanced μ-CT. A quantitative comparison of fuel swelling between this localized microscopic U-10Zr fuel region, previously irradiated in the Fast Flux Test Facility, and historic U-10Zr fuels irradiated in the Experimental Breeder Reactor-II (EBR-II) was conducted. It was determined that for similar burnups, the localized swelling in this microscopic fuel region was 7.7%, which was approximately one-half of the value of the macroscopic swelling reported in EBR-II irradiated fuel. With the advent of new specimen preparation tools for irradiated materials, as well as advances in characterization techniques, researchers can now obtain previously inaccessible microstructural insight into irradiated fuels. This possibility naturally lends itself to improved fuel performance models for the nuclear community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Variable Continuous Bimaterial Interface in the San Jacinto Fault Zone Revealed by Dense Seismic Array Analysis of Fault Zone Head Waves

Key factors controlling earthquake ruptures include fault geometry, continuity, and seismic velocity structure around the fault. We present a novel tool that better informs deep bimaterial fault geometry embedded in distributed damage and seismicity, associated velocity contrasts across the fault, and their correlations with surface complexities. The method employs fault zone head and direct body waves and is applied to recordings from five spatiotemporally different seismic arrays along the complex San Jacinto fault zone (SJFZ) in southern California. We detect and distinguish these signals based on instantaneous phase coherence and relative energy in a cascading manner from one scale array to another. The analysis reveals a >70-km long continuous bimaterial interface within the SJFZ with several deep northeast dipping fault segments. The northern SJFZ, for instance, locates ~7 km northeast of its surface expression at 18-km depth. P-wave velocity contrasts range from near 0% to >15%, consistent with other bimaterial faults, and differ by a few % depending on fault-array azimuth, implying directional-dependent velocity contrasts. S-wave head waves and velocity contrasts are also imaged for the first time at the southern SJFZ, averaging to 2.9% in agreement with tomography results. The imaged geometry and continuity suggest the SJFZ initiated along remnant tectonic structures and translates to a rupture potential of M > 7.2, i.e., the sizes of its largest paleo-earthquakes. The P and S contrasts, and their ratios, have important implications for earthquake rupture speed, mode, directivity, and frictional heating along the SJFZ and other major faults globally.

58 GEOSCIENCES↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗