Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Connector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

CryoCart Restoration and Vacuum Pipe Construction

Propulsion systems that utilize hypergolic propellants have been used to power space vehicles since the beginning of the space program. Liquid methane and oxygen propulsion systems have emerged as an alternative and have proven to be more environmentally friendly. The incorporation of liquid methane/liquid oxygen (LOX) into the propulsion system has demonstrated an increase in engine performance, as well as a reduction in the volume, size and complexity of the system. Consequently, reducing the total mass of the vehicle which is a crucial aspect that is considered when planning space missions to both the Moon and Mars [1]. Project Morpheus has made significant advancements in liquid oxygen/liquid methane propulsion system technologies by incorporating a LOX/methane propulsion system to a vertical test bed. The vehicle consisted of a 5,000 lb main engine and four 20 lb remote control system (RCS) engines that utilize liquid methane/LOX as its propellant [1]. The vehicle completed successful flight testing at Kennedy Space Center in 2014 which marked the completion of the Morpheus project. Subsequent projects utilizing Morpheus' vertical test bed have been developed to make further advancements. One of the subsequent projects consisted of the addition of a smaller 2,000 lb main engine and a cold helium heat exchanger which would make it possible for a pressurant tank systems to be send to Mars or the Moon by significantly decreasing the overall mass and volume of the pressurant tank. The hot fire tests of the integrated system with the smaller main engine and cold helium heat exchanger were successful at sea level, but further studies are being conducted to better understand how the vertical test bed will behave under thermal-vacuum conditions. For this reason, the integrated vehicle will be taken to Plum Brook to be tested in a chamber capable of simulating these conditions. To ensure that the vehicle will function properly under vacuum conditions, testing will be first completed at the component level. During this process, the igniter of the main engine and the RCS thrusters will be tested under a vacuum. To complete the testing of the components, the test setup first needed to be finalized. The CryoCart is being used to feed the propellants to the test article. The CryoCart is a movable test set-up that was developed in 2009 to provide a mobile platform for testing oxygen/methane systems with hot-fire capability up to 100 lbf. The CryoCart consists of three different systems: Oxygen, Methane, and liquid Nitrogen. The Oxygen and Methane systems are placed into two different carts while the liquid nitrogen system is mainly located in the methane cart. Over the years, the CryoCart has been utilized for different projects and has undergone deterioration. For this reason, a new phase has been developed to rebuild it to working conditions once again. During my internship, I was aiding in the construction and restoration of the CryoCart. In the initial stages of the process, I updated the fluid and electrical schematics for the oxygen, methane, and test article systems. The original CryoCart consisted of an electrical panel that utilized electromechanical relays and a terminal to drive the igniter power and signal, as well as the main fuel and oxygen valves. This electrical panel connected to the CryoCart through various wire harnesses that could be found exiting from the CryoCart. First, it was determined how these harnesses connected to the electromechanical relays so that they worked correctly. Once the electrical system was understood, an alternative for the electromechanical relays and the Molex connectors used throughout the system was sought since these components can often prove to be unreliable. Solid State relays and MIL connectors were purchased to serve as replacements. Upon arrival of the parts, crimping and wiring was completed to install the new solid state relays and MIL connectors. During the replacement of the relays and connectors, system checks of the electrical system were ran to ensure that the system was working correctly. While completing system checks, the pressure transducers that were not functioning properly were also replaced and any issue with the wiring or signal was addressed. Once the electrical components were replaced, the restoration of the fluid system began. Parts of the tubing in the CryoCart had to be rebuild and often consisted of sizing, cutting, bending, filing, and sanding the tubing to prepare it to be flared. Many components had to be proof-tested to bring their certifications up to date, and several components had to be replaced. Various flex hoses, valves, and fittings were send to the Clean Lab because they were new, dirty, or had gone through proof-testing. Once they arrived from the cleaning lab they had to be put back to the system and leak checks and functional tests were conducted. In the Nitrogen system, the copper tubing located in the Oxygen cart was rebuild and Aerogel insulation was added to this section. A new gaseous nitrogen system was added to the CryoCart to purge the vacuum tube which will serve as the test chamber. Once the CryoCart was completed, construction of parts of the vacuum tube began. A flange was manufactured with welded fittings to hold the line of the vacuum pump as well as some extra fittings which will serve as extra inlets used to introduce fluid lines to the vacuum tube. Stress analysis was ran in this flange to ensure that it would not fail under vacuum conditions. The fluid lines leading from the air side of the vacuum to the test article were also constructed and added to the mount that had already been manufactured. Three different sets of tubing were constructed to accommodate the seven different RCS thruster and the main engine igniter that are going to be tested. Full electrical system checks were completed to ensure that all the wire harnesses and valves were functioning. Upon the completion of the CryoCart and the vacuum tube, hot fire testing for the RCS thrusters and the main engine igniter are going to begin. During this time any issues encountered with the engines or igniter will be addressed to ensure that the components function under vacuum conditions. After successful completion of testing, the vertical test bed, Morpheus, will be rebuilt and prepared to be sent to Plum Brook. In Plum Brook, the vehicle will be tested in the thermal-vacuum chamber to demonstrate that integrated lox-methane propulsion system operation in space-like conditions. This internship has allowed me the opportunity to gain valuable hands on experience and to develop skills that will aid in my education as well as in the workforce, while at the same time helping me determine that I would like to further pursue a career in propulsion engineering.

Chaidez, Mariana↗

Gas sensor system

A gas sensing tube includes an outer surface, and an inner surface defining a passage. A sensor node is arranged along the sensing tube. The sensor node includes an inlet fluidically connected to the passage, an outlet fluidically connected to the passage, and an interior chamber arranged between the inlet and the outlet. A sensor cable extends along the sensing tube. The sensor cable includes a first conduit having a first connector coupled to the sensor node at the inlet and a second conduit having a second connector connected to the sensor node at the outlet. The sensor cable has a first conductor extending through the first conduit and being coupled to the first connector and a second conductor extending through the second conduit and being coupled to the second connector.

Challener, William Albert↗

System and method of making an enhanced cast iron crankshaft

A method and system for manufacturing a cast iron crankshaft for a vehicle are provided. The system comprises a molding unit arranged to form a negative sand cast mold of the cast iron crankshaft. The mold comprising at least one molded cavity having a pattern with dimensions of the cast iron crankshaft. The system further comprises a feeding mechanism comprising a riser having a connector through which molten metallic material flows to the cast mold. The feeding mechanism feeds the molten metallic material at a riser connection angle in the at least one mold cavity. The riser connection angle corresponds to a connector modulus. The connector modulus is 20% greater than a cast modulus. The riser geometry corresponds to a riser modulus. The riser modulus is 20% greater than the connector modulus. The system further comprises a furnace, a cooling area, a separation unit, a controller and a power source.

Wang, Liang↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dust Tolerant Commodity Transfer Interface Mechanisms for Planetary Surfaces

Regolith is present on most planetary surfaces such as Earth's moon, Mars, and Asteroids. If human crews and robotic machinery are to operate on these regolith covered surfaces, they must face the consequences of interacting with regolith fines which consist of particles below 100 microns in diameter down to as small as submicron scale particles. Such fine dust will intrude into mechanisms and interfaces causing a variety of problems such as contamination of clean fluid lines, jamming of mechanisms and damaging connector seals and couplings. Since multiple elements must be assembled in space for system level functionality, it will be inevitable that interfaces will be necessary for structural connections, and to pass commodities such as cryogenic liquid propellants, purge and buffer gases, water, breathing air, pressurizing gases, heat exchange fluids, power and data. When fine regolith dust is present in the environment it can be lofted into interfaces where it can compromise the utility of the interface by preventing the connections from being successfully mated, or by inducing fluid leaks or degradation of power and data transmission. A dust tolerant, hand held "quick-disconnect" cryogenic fluids connector housing has been developed at NASA KSC which can be used by astronaut crews to connect flex lines that will transfer propellants and other useful fluids to the end user. In addition, a dust tolerant, automated, cryogenic fluid, multiple connector, power and data interface mechanism prototype has been developed, fabricated and demonstrated by NASA at Kennedy Space Center (KSC). The design and operation of these prototypes are explained and discussed.

Dust Tolerant↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Nanometer-Scale Fullerene-Type Conjugated Covalent Cages Based on Triazine: Design, Doping with Li + , and H 2 /CO 2 Adsorption

Spherical and hollow molecular cages based on planar triazine (C 3 N 3 ) hubs and aromatic phenylene connectors have been developed. The cages exhibit topologies akin to C 20 , C 60 , and C 70 fullerenes with diameters that range from 2.3 to 4.9 nm. Apertures into the cage interiors are tuned by varying the aromatic connectors situated between the C 3 N 3 -units. The stabilities of the C 3 N 3 cages increase with size owing to reduced bending strain of planar nodes and connectors that make up the spherical aromatic networks. Doping of the cages with Li + reveals the capacity of the cages for significant adsorption of gaseous H 2 and CO 2 . The design of graphene-like spherical cages is also discussed.

DFT calculations↗

Spherical Congeners of Polyaromatic Compounds Approaching C 20 - and C 60 -Fullerene-Type Structures

A series of three symmetric, hollow spherical, and shape-persistent molecular organic cages analogous to C 20 and C 60 were examined by computational modeling, analyzing structural elements, strain indicators, and physical properties relevant for potential applications. The compounds are covalent aromatic cages based on 1,3,5-substituted benzene nodes linked by paraphenylene or para-pyrenylene-connectors, with diameters varying from 2.3 to 4.2 nm. The apertures in the cage interior are varied by virtue of the cage type (C 20 - or C 60 -type cage) and the linear connectors placed between the C 6 H 3 -units. NBO and MESP analyses indicate the presence of electrophilic and nucleophilic sites in the molecular skeleton. In the cages with the phenylene-connectors, the HOMO−LUMO gaps are close to 4.0 eV. In the cage coated with an enlarged polyaromatic spacer (pyrene-unit), the gap is reduced by approximately 0.4 eV.

Aromatic compounds↗

TTW (Transition to Wire Device) [SWR-25-02]

The Transition to Wire (TTW) hardware project is a method for connecting solar research samples with fragile interconnects to robust, weatherproof and consistent commercial connectors. The Transition to Wire device is a printed circuit board designed to facilitate the transition from tab ribbon or other unsecured electrical contacts on research samples to either wires or a connector. The four pin connector provides a kelvin (4 wire) connection at the solder pad where the sample connects.

McDanold, Byron↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Floating device aligns blind connections

Panel-mounted connectors overcome the misalignment of blind connectors in electronic rack mounted equipment. The connector is free to move in the vertical direction by the action of a parallelogram mount. This freedom of motion maintains the guide pin hole centerline parallel to the guide pin centerline at all times.

Resel, J. E.↗

Contact-resistance test probes: A concept

Devices are used in inspection of contact resistance in plated connectors after assembly into cables. System permits rapid inspection of connectors when mating connectors or special apparatus are not available, and enables source of excessive resistance to be precisely determined.

Brooks, C. H.↗

A simple, efficient resistance soldering apparatus

Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.

Vermillion, C. M.↗

Leak detection with expandable coatings

Developed and evaluated is a system for leak detection that can be easily applied over separable connectors and that expands into a bubble or balloon if a leak is present. This objective is accomplished by using thin films of Parafilm tape wrapped over connectors, which are then overcoated with a special formulation. The low yield strength and the high elongation of the envelope permit bubble formation if leakage occurs. This system is appropriate for welds and other hardware besides separable connectors. The practical limit of this system appears to be for leaks exceeding 0.000001 cc/sec. If this envelope is used to trap gases for mass spectrometer inspection, leaks in the range of ten to the minus 8th power cc/sec. may be detectable.

Source record↗