Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Low-cost, fast-response drive circuit for electromagnetic torque motors

Fast-response coil drive circuit, for electromagnetic torque motors, reduces the inductive coil time constant with a minimum of circuit sophistication. The low-cost modulator servoamplifier is used with a compatible preamplifier stage which provides the servo-loop function of summing, adjustable gain and compensation.

Zeller, J. R.↗

An improved Orbitron ionization gage measures ultrahigh vacuum

Ionization gage with improved signal-to-noise ratio has a helical coil electrode which separates the solid cathode ion collector from the volume where ionization of gas molecules takes place. Helical coil increases lifetime of electrons and reduces secondary emission from the collector.

Gosselin, C. M.↗

Device measures conductivity and velocity of ionized gas streams

Coaxial arrangement of primary coil and two sensing secondary coils contained inside slender quartz tube inserted into ionized stream permits simultaneous determination of conductivity and linear velocity. System results agree favorably with theory.

Cook, G. R.↗

SSA-A spacecraft magnetic tests

In the initial magnetic tests the spacecraft perm moment as received was 43 milliampere-meter squared (pole-cm), which was reduced by deperm treatment to milliampere-meter squared. Facility fluxgate probe bias results indicated Z axis bias at the SSS-A fluxgate magnetometer position to be about one half nanotesla (gamma) after Z axis deperm. The ASCS magnetometers, 01 and 02, were successfully aligned and proper operation of the ASCS system were verified. The spacecraft fluxgate magnetometer was calibrated in both the high and low sensitivity modes after a defective 01 electronics card was replaced. Problems were encountered in the Z axis search coil during calibration and the test was re-scheduled. Final test results indicated that the total perm moment could not be reduced any lower than 35 milliampere-meter squared by deperm treatment. However, the Z axis moment decreased from 22 milliampere-meter squared to 6 milliampere-meter squared after deperm. Correct operation and calibration was verified for all three axes of the spacecraft fluxgate magnetometer and no significant bias was observed during stray field testing. Null and spot calibration of the ASCS magnetometer was completed and the measured spin and attitude coil moments were: 2535 and 9820 milliampere-meter squared respectively.

Roy, T. N.↗

UK-4 prototype spacecraft magnetic tests

The spacecraft was tested in a magnetic test facility which uses a 42 ft. diameter coil system to produce a controlled magnetic field of high uniformity over a large central volume. The primary objectives of the tests were: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft and to assess its magnetic stability; (2) to evaluate the magnetorquer coil system; and (3) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft. The test facility and procedures are described together with the results obtained. In addition, the problems encountered during the tests and the significance of the test findings are discussed.

Pruett, W. E.↗

Terrestrial adaptation of the thermal heliotrope.

The principle of using bimetal helical coils to cause solar arrays to track the sun in space is presently under consideration for array orientation on several spacecraft. Adaptation of this thermal heliotrope to terrestrial applications introduces additional design considerations. The dominance of solar-radiation energy input to the helical coil over convective energy losses has to be ensured, and wind effects must be minimized. As long as the cost of solar cells remains high, orientation will always result in a significant cost saving for the converter.

Fairbanks, J. W.↗

Bimetallic devices for stirring fluids

Device consists of helical heating coil inside cylinder and affixed at one end. Piston is fastened at other end and is free to move axially through cylinder. Electrical power extends coil when applied to conductors. Bimetallic stirrer may also be made in vane form.

Canning, T. N.↗

Stabilizing a gaseous optical laser

Frequency of gaseous optical laser can be stabilized by sinusoidally modulating the geometry of the cavity. Fabry-Perot dielectric mirrors are mounted in two Invar blocks that are connected by four magnetorestrictive bars. Each bar has three coils to sinusoidally modulate system. Ac establishes frequency, and dc the average value; both are supplied to coil from control system.

Jauan, A.↗

Electromagnetic position sensor for a magnetically supported model in a wind tunnel

An investigation was undertaken to determine the feasibility of using superconducting force-producing coils for positioning a model in a wind tunnel. The cryostat containing the forcing coils surrounded the test section of the tunnel, thus favoring an electromagnetic position sensor. Another reason favoring this choice was the fact that the performance of an electromagnetic sensor is essentially unaffected by the shape of the model.

Towler, W. R.↗

NASA superconducting magnetic mirror facility

The design details and initial test results of a superconducting magnetic mirror facility that has been constructed at NASA Lewis Research Center for use in thermonuclear research are summarized. The magnet system consists of four solenoidal coils which are individually rated at 5.0 T. Each coll is composed of an inner, middle, and outer winding. The inner winding is wound of stabilized Nb3Sn superconducting ribbon, and the middle and outer windings are wound of stabilized Nb-Ti superconducting wire. When arranged in the mirror geometry, the four coils will produce 8.7 T at the mirrors and a 1.8 mirror ratio. The magnet has a 41-cm diameter clear bore which is open to atmosphere. Distance between the mirrors is 111 cm. Presently there are only three magnets in the facility; the fourth magnet is being rebuilt.

Reinmann, J. J.↗

Heat operated cryogenic electrical generator

An electrical generator useful for providing electrical power in deep space, is disclosed. The electrical generator utilizes the unusual hydrodynamic property exhibited by liquid helium as it is converted to and from a superfluid state to cause opposite directions of rotary motion for a rotor cell thereof. The physical motion of the rotor cell was employed to move a magnetic field provided by a charged superconductive coil mounted on the exterior of the cell. An electrical conductor was placed in surrounding proximity to the cell to interact with the moving magnetic field provided by the superconductive coil and thereby generate electrical energy. A heat control arrangement was provided for the purpose of causing the liquid helium to be partially converted to and from a superfluid state by being cooled and heated, respectively.

Wang, T. G.↗

Electronic magnification for astronomical camera tubes

Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.

Vine, J.↗

Magnetic suspension techniques for large scale aerodynamic testing

The potential utility of magnetic suspension techniques is discussed in the context of current efforts towards realistic aerodynamic simulation in wind tunnels. Design parameters are defined and problems of constructing large size facilities identified. A three stage strategy towards realizing a truly large scale magnetic suspension and balance with full research capability is outlined. Stage one, consisting of building and testing a prototype superconductor coil system to establish the feasibility of the concept has been completed successfully and its principal results are briefly described. This proven feasibility of using superconductors for magnetic suspensions, together with the successful demonstration of the cryogenic wind tunnel concept, appear to have opened the way to clean tunnel, high-Re aerodynamic testing. Results of a comparative analysis of scaling of several coil technologies for a specific magnetic suspension configuration, from the prototype size to a size compatible with the projected high Reynolds number cryogenic wind tunnel facility, are discussed in some detail.

Zapata, R. N.↗

The response of smoke detectors to pyrolysis and combustion products from aircraft interior materials

The following projects were completed as part of the effort to develop and test economically feasible fire-resistant materials for interior furnishings of aircraft as well as detectors of incipient fires in passenger and cargo compartments: (1) determination of the sensitivity of various contemporary gas and smoke detectors to pyrolysis and combustion products from materials commonly used in aircraft interiors and from materials that may be used in the future, (2) assessment of the environmental limitations to detector sensitivity and reliability. The tests were conducted on three groups of materials by exposure to the following three sources of exposure: radiant and Meeker burner flame, heated coil, and radiant source only. The first test series used radiant heat and flame exposures on easily obtainable test materials. Next, four materials were selected from the first group and exposed to an incandescent coil to provide the conditions for smoldering combustion. Finally, radiant heat exposures were used on advanced materials that are not readily available.

Mckee, R. G.↗

Bias-field equalizer for bubble memories

Magnetoresistive Perm-alloy sensor monitors bias field required to maintain bubble memory. Sensor provides error signal that, in turn, corrects magnitude of bias field. Error signal from sensor can be used to control magnitude of bias field in either auxiliary set of bias-field coils around permanent magnet field, or current in small coils used to remagnetize permanent magnet by infrequent, short, high-current pulse or short sequence of pulses.

Keefe, G. E.↗

Design study of superconducting magnets for a combustion magnetohydrodynamic (MHD) generator

Design trade off studies for 13 different superconducting magnet systems were carried out. Based on these results, preliminary design characteristics were prepared for several superconducting magnet systems suitable for use with a combustion driven MHD generator. Each magnet generates a field level of 8 T in a volume 1.524 m (60 in.) long with a cross section 0.254 m x 0.254 m (10 in. x 10 in.) at the inlet and 0.406 m x .406 m (16 in. x 16 in.) at the outlet. The first design involves a racetrack coil geometry intended for operation at 4.2 K; the second design uses a racetrack geometry at 2.0 K; and the third design utilizes a rectangular saddle geometry at 4.2 K. Each case was oriented differently in terms of MHD channel axis and main field direction relative to gravity in order to evaluate fabrication ease. All cases were designed such that the system could be disassembled to allow for alteration of field gradient in the MHD channel by changing the angle between coils. Preliminary design characteristics and assembly drawings were generated for each case.

Thome, R. J.↗

Sustained arc ignition system

Circuitry for maintaining an arc or spark across a spark gap for a desired length of time is disclosed. A high voltage, direct current source is connected in series with a secondary winding of a high voltage, stepup transformer or coil and a spark gap such as a spark plug for example. The high voltage source may be on continuously or may be turned on and off by a control circuit such as a solid state switch which is, in turn, responsive to a timing device such as a set of ignition contact points or a magnetic pulse generator operating in synchronism with a spark ignition engine. The timing device also provides signals to a current switching circuit which interrupts, current flow through a primary winding of the high voltage coil at the prescribed time that a spark is desired at the spark gap.

Birchenough, A. G.↗