Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The effects of transmitter/receiver clock time-base instability on coherent communication system performance

The purpose of this paper is to present a model and associated analysis of the deleterious effects which both transmitter and receiver data clock time-base instability have on bit-error probability. The types of time-base instability modeled and analyzed include what is commonly referred to as bit jitter (epoch jitter), bit-jitter rate (time interval jitter), and data asymmetry. The bit-error probability is determined as a function of the statistical characteristics of the time-base instability, the data-transition density, the signal-to-noise ratio in the bit-rate bandwidth and the mechanizations of both the data-bit detector and bit synchronizer. The latter is manifested through the bit synchronizer's natural frequency and loop-damping parameters. Numerical results which indicate the sensitivity of the system bit-error rate to various parameters of the model are provided.

Chie, C. M.↗

A generalization of the near-optimum binary coherent state receiver concept

The structure of a maximum a posteriori decoder is derived for binary optical fields processed according to Kennedy's near-optimum scheme, but operating in the presence of random optical phase-error and interfering background fields. An exact expression is found for the error probability, and examples to illustrate decoder performance under various operating conditions of interest are provided.

Vilnrotter, V. A.↗

Advances in the electron diffraction characterization of atomic clusters and nanoparticles

Nanoparticles and metallic clusters continue to make a remarkable impact on novel and emerging technologies. In recent years, there have been impressive advances in the controlled synthesis of clusters and their advanced characterization. One of the most common ways to determine the structures of nanoparticles and clusters is by means of X-ray diffraction methods. However, this requires the clusters to crystallize in a similar way to those used in protein studies, which is not possible in many cases. Novel methods based on electron diffraction have been used to efficiently study individual nanoparticles and clusters and these can overcome the obstacles commonly encountered during X-ray diffraction methods without the need for large crystals. These novel methodologies have improved with advances in electron microscopy instrumentation and electron detection. Here, we review advanced methodologies for characterizing metallic nanoparticles and clusters using a variety of electron diffraction procedures. These include selected area electron diffraction, nanobeam diffraction, coherent electron diffraction, precession electron diffraction, scanning transmission electron microcopy diffraction, and high throughput data analytics, which leverage deep learning to reduce the propensity for data errors and translate nanometer and atomic scale measurements into material data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Faster Randomized Dynamical Decoupling

We present a randomized dynamical decoupling (DD) protocol that can substantially improve the performance of any given deterministic DD scheme for suppressing coherent noise by using no more than two additional pulses. Our construction is implemented by probabilistically applying sequences of pulses, which, when combined, effectively eliminate the error terms that scale linearly with the system-environment coupling strength. As a result, we show that a randomized protocol using a few pulses can outperform deterministic DD protocols that require considerably more pulses. Furthermore, we prove that the randomized protocol provides an improvement compared to deterministic DD sequences that aim to reduce the error in the system’s Hilbert space, such as Uhrig DD, which had been previously regarded to be optimal. To rigorously evaluate the performance, we introduce new analytical methods suitable for analyzing higher-order DD protocols that might be of independent interest. Here, we also present numerical simulations confirming the significant advantage of using randomized protocols compared to widely used deterministic protocols.

Quantum algorithms & computation↗

Reexamining classical and quantum models for the D-Wave One processor: The role of excited states and ground state degeneracy

We revisit the evidence for quantum annealing in the D-Wave One device (DW1) based on the study of random Ising instances. Using the probability distributions of finding the ground states of such instances, previous work found agreement with both simulated quantum annealing (SQA) and a classical rotor model. Thus the DW1 ground state success probabilities are consistent with both models, and a different measure is needed to distinguish the data and the models. Here in this paper we consider measures that account for ground state degeneracy and the distributions of excited states, and present evidence that for these new measures neither SQA nor the classical rotor model correlate perfectly with the DW1 experiments. We thus provide evidence that SQA and the classical rotor model, both of which are classically efficient algorithms, do not satisfactorily explain all the DW1 data. A complete model for the DW1 remains an open problem. Using the same criteria we find that, on the other hand, SQA and the classical rotor model correlate closely with each other. To explain this we show that the rotor model can be derived as the semiclassical limit of the spin-coherent states path integral. We also find differences in which set of ground states is found by each method, though this feature is sensitive to calibration errors of the DW1 device and to simulation parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fidelity of Satellite Soundings

Two pattern recognition procedures to provide improvements to first guess fields for satellite temperature retrievals were developed. The first technique where a radiometer measurement is used to select one or more historical radiosonde temperature profiles as analog estimates of ambient thermal structure. Radiosondes are the vertical scales of the analogs. The vertical resolving power of the satellite radiometer is relevant only to a decision process. The analog selection process is much more effective if implemented in an orthogonalized space of measurement information. The second procedure partitions a priori dependent data into shape coherent pattern libraries using structure information inherent in the data itself. It is shown that the pattern recognition techniques are able to reduce first guess profile errors by nearly 50%. The impact of pattern recognition on temperature retrieval error is assessed by regression and physical iterative retrieval algorithms. The influence of improved first guess fields is markedly different on these two types of algorithm. Pattern recognition was a strong positive impact on the physical iterative method.

Thompson, O.↗

Free-space coherent optical communication receivers implemented with photorefractive optical beam combiners

Performance measurements are reported concerning a coherent optical communication receiver that contained an iron doped indium phosphide photorefractive beam combiner, rather than a conventional optical beam splitter. The system obtained a bit error probability of 10(exp -6) at received signal powers corresponding to less than 100 detected photons per bit. The system used phase modulated Nd:YAG laser light at a wavelength of 1.06 microns.

Davidson, Frederic M.↗

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

Quantum computer-enabled receivers for optical communication

Abstract Optical communication is the standard for high-bandwidth information transfer in today’s digital age. The increasing demand for bandwidth has led to the maturation of coherent transceivers that use phase- and amplitude-modulated optical signals to encode more bits of information per transmitted pulse. Such encoding schemes achieve higher information density, but also require more complicated receivers to discriminate the signaling states. In fact, achieving the ultimate limit of optical communication capacity, especially in the low light regime, requires coherent joint detection of multiple pulses. Despite their superiority, such joint detection receivers are not in widespread use because of the difficulty of constructing them in the optical domain. In this work we describe how optomechanical transduction of phase information from coherent optical pulses to superconducting qubit states followed by the execution of trained short-depth variational quantum circuits can perform joint detection of communication codewords with error probabilities that surpass all classical, individual pulse detection receivers. Importantly, we utilize a model of optomechanical transduction that captures non-idealities such as thermal noise and loss in order to understand the transduction performance necessary to achieve a quantum advantage with such a scheme. We also execute the trained variational circuits on an IBM-Q device with the modeled transduced states as input to demonstrate that a quantum advantage is possible even with current levels of quantum computing hardware noise.

97 MATHEMATICS AND COMPUTING↗

Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

Christopher J. Pagnanelli↗

(abstract) Application of Non-coherent Data Types for Deep Space Navigation

Several options are being examined to reduce the costs of spacecraft and deep space missions. One such option is to fly spacecraft in a non-coherent mode, that is, the spacecraft does not carry a transponder and cannot coherently return a Doppler signal. Historically, such one-way data has not been used as the sole data type due to the instability of the onboard oscillator, the use of S-band frequencies, and the corresponding larger error sources which could not be modeled. However, with the advent of high-speed work stations and more sophisticated modeling ability, the possibility of using one-way data is being re-examined. This paper addresses the navigation performance of various one-way data types for use in interplanetary missions.

deep space navigation non-coherent data spacecraft↗

Dual-wavelength vertical scanning low-coherence interferometric microscope

White-light interferometry has turned into a standard tool in the field of high-accuracy topography measurements. Nevertheless, surfaces with relatively large local surface tilts or height steps often give rise to systematic measuring errors. The reasons are diffraction and dispersion effects, which cause deviations between height values obtained from the envelope maximum of the white-light interference signal and those obtained from the signal's phase. In certain cases this may result in ghost steps appearing in the measured topography. To identify and eliminate these ghost steps we use a second LED emitting light at a different mean wavelength. This now allows the measurement of curved or structured specular surfaces with high resolution, which up to now was restricted by the mentioned effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Quantum displacement receiver for M-ary phase-shift-keyed coherent states

We propose quantum receivers for 3- and 4-ary phase-shift-keyed (PSK) coherent state signals to overcome the standard quantum limit (SQL). Our receiver, consisting of a displacement operation and on-off detectors with or without feedforward, provides an error probability performance beyond the SQL. We show feedforward operations can tolerate the requirement for the detector specifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of intensity fluctuations in quantum cryptography with coherent states

A new type of attack in quantum cryptography with coherent states is considered. This attack calls for only a possibility of changing (within some limits) the intensity of the states reaching a receiver. The critical quantum bit error rate (QBER) of the B92 protocol with a strong reference state is calculated for different limitations on intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of SU(1,1) coherent states for the damped harmonic oscillator

Gerry, Ma, and Vrscay [Phys. Rev. A 39, 668 (1989)] studied the time evolution of SU(1,1) coherent states for the damped harmonic oscillator by introducing the Kanai-Caldirola Hamiltonian. The purposes of this Brief Report are to demonstrate that there are somewhat serious errors on their results and to correct them. Most of the figures given in their work are reproduced with correction in order to facilitate our explanation of results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-pump Coherent anti-Stokes Raman scattering measurements in H 2 /CH 4 Counterflow Flames

Temperature and major species concentration measurements are reported in a Williams Seshadri counterflow burner using dual-pump coherent anti-Stokes Raman scattering (DPCARS). Hencken burner H2/Air flames with equivalence ratio of 0.8-1.4 were used to characterize the accuracy of the system. The mean errors for temperature, XH2/XN2 mole fraction ratio, and XO2/XN2 mole fraction ratio are 1.0%, 14.7%, and 5.5%, respectively. The counterflow burner uses a CH4, H2, and N2 mixture as fuel and synthetic air as oxidizer. Measurements were performed along the counterflow burner central axis for two different fuel compositions: 4% H2/86% CH4/10% N2 and 87%H2/3% CH4/10% N2. The measured temperature and species mole fractions agree well with the 1-D opposed-flow diffusion flame simulation. One observation is that the fuel inlet temperature is higher than 300 K, which suggests the possibility of the stagnation plane residing closer to the fuel side. Lastly, these measurements provide valuable data for testing and validation of advanced 2-D flame models.

Murdock, Benjamin K.↗