Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean Cities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

VA EDH Data Curation Documentation FY22-Q4

The health and well-being of the Nation’s men and women who have served in uniform is the highest priority for the U.S. Department of Veterans Affairs (VA). VA is committed to providing timely access to high-quality, recovery-oriented, evidence-based mental health care that anticipates and responds to Veterans’ needs and supports the reintegration of returning Service members into their communities. VA is working to eliminate suicide among all Veterans by developing and implementing innovative suicide prevention approaches and resources. Health outcomes, such as suicide are typically modeled as a function of genetics and environment, where environment refers to factors beyond medical, e.g., air quality, access to transportation and food, homelessness status, etc. Mental health outcomes for each individual are considered to be associated with multiple stressors that fall under a variety of categories socioeconomic, economic, physical environment. Understanding the relationships between these stressors, covariates, and health outcomes, requires curated, standardized data that can be input into the VA’s Recovery Engagement and Coordination for Health - Veterans Enhanced Treatment (REACH VET) or other health outcomes model. Environmental Determinants of Health (EDH) as defined by the World Health Organization (WHO) is clean air, stable climate, adequate water, sanitation and hygiene, safe use of chemicals, protection from radiation, healthy and safe workplaces, sound agricultural practices, health-supportive cities and built environments, and a preserved nature are all prerequisites for good health.

99 GENERAL AND MISCELLANEOUS↗

VA EDH Data Curation Documentation FY23-Q2

The health and well-being of the Nation’s men and women who have served in uniform is the highest priority for the U.S. Department of Veterans Affairs (VA). VA is committed to providing timely access to high-quality, recovery-oriented, evidence-based mental health care that anticipates and responds to Veterans’ needs and supports the reintegration of returning Service members into their communities. Since its creation, VA has been working to eliminate suicide among all veterans by developing and implementing innovative suicide prevention approaches and resources. Health outcomes, such as suicide are typically modeled as a function of genetics and environment, where environment refers to factors beyond medical, e.g., air quality, access to transportation and food, homelessness status, etc. Mental health outcomes for each individual are considered to be associated with multiple stressors that fall under a variety of categories including socioeconomic, economic, physical environment. Understanding the relationships between these stressors, covariates and health outcomes requires curated, standardized data that can be input into the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET) or other health outcomes model. Environmental Determinants of Health (EDH) as defined by the World Health Organization (WHO) is clean air, stable climate, adequate water, sanitation and hygiene, safe use of chemicals, protection from radiation, healthy and safe workplaces, sound agricultural practices, health-supportive cities and built environments, and a preserved nature are all prerequisites for good health.

99 GENERAL AND MISCELLANEOUS↗

VA EDH Data Curation Documentation FY23-Q3

The health and well-being of the Nation’s men and women who have served in uniform is the highest priority for the U.S. Department of Veterans Affairs (VA). VA is committed to providing timely access to high-quality, recovery-oriented, evidence-based mental health care that anticipates and responds to Veterans’ needs and supports the reintegration of returning Service members into their communities. Since its creation, VA has been working to eliminate suicide among all veterans by developing and implementing innovative suicide prevention approaches and resources. Health outcomes, such as suicide are typically modeled as a function of genetics and environment, where environment refers to factors beyond medical, e.g., air quality, access to transportation and food, homelessness status, etc. Mental health outcomes for each individual are considered to be associated with multiple stressors that fall under a variety of categories including socioeconomic, economic, physical environment. Understanding the relationships between these stressors, covariates and health outcomes requires curated, standardized data that can be input into the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET) or other health outcomes model. Environmental Determinants of Health (EDH) as defined by the World Health Organization (WHO) refers to clean air, stable climate, adequate water, sanitation and hygiene, safe use of chemicals, protection from radiation, healthy and safe workplaces, sound agricultural practices, health-supportive cities and built environments, and a preserved nature are all prerequisites for good health.

97 MATHEMATICS AND COMPUTING↗

VA EDH Data Curation Documentation FY23-Q4

The health and well-being of the Nation’s men and women who have served in uniform is the highest priority for the U.S. Department of Veterans Affairs (VA). VA is committed to providing timely access to high-quality, recovery-oriented, evidence-based mental health care that anticipates and responds to Veterans’ needs and supports the reintegration of returning service members into their communities. Since its creation, the VA has been working to eliminate suicide among all veterans by developing and implementing innovative suicide prevention approaches and resources. Health outcomes, such as suicide, are typically modeled as a function of genetics and environment, where environment refers to factors beyond medical, e.g., air quality, access to transportation and food, homelessness status, etc. Mental health outcomes for each individual are considered to be associated with multiple stressors that fall under a variety of categories, including socioeconomic, economic, and physical environments. Understanding the relationships between these stressors, covariates, and health outcomes requires curated, standardized data that can be input into the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET) or other health outcomes model. Environmental Determinants of Health (EDH), as defined by the World Health Organization (WHO), refer to clean air, stable climate, adequate water, sanitation and hygiene, safe use of chemicals, protection from radiation, healthy and safe workplaces, sound agricultural practices, health-supportive cities and built environments, and a preserved nature, which are all prerequisites for good health.

60 APPLIED LIFE SCIENCES↗

Preparing the Power Sector to Navigate Climate and Water Risks

As the climate changes, so will water availability and other ambient conditions, threatening the reliability of today's power system and tomorrow's clean energy grid. That's why researchers at the National Renewable Energy Laboratory (NREL) - along with those at Sandia National Laboratories, Oak Ridge National Laboratory, the City University of New York, the Electric Power Research Institute, and the National Energy Technology Laboratory - are studying both regional and national climate and hydrologic changes to provide a comprehensive assessment of climate and water impacts and risks to the U.S. power grid.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Session 077 - Panel: Wednesday US DOE Featured Site: Lexington, KY Office (Portsmouth and Paducah Sites) (R1.14)

This panel featured the DoE's Portsmouth Paducah Project Office (PPPO), which is responsible for the management and cleanup of at the Portsmouth, Ohio and Paducah, Kentucky former Gaseous Diffusion Plant sites. Portsmouth is primed for the first major skyline change at the site the upcoming demolition of the X-326 process building and initial operations of the Onsite Waste Disposal Facility. The Paducah site is working on the C-400 city block initiative allowing DOE to tackle the main source of groundwater contamination at the site, in conjunction with deactivation and demolition of the C-400 Cleaning Building. PPPO's DUF6 conversion plants have 7 lines in continuous operation at both sites providing the opportunity to ramp up cylinder processing. Panelists with presentations: DOE PPO Update (Robert Edwards, Joel Bradburne); Portsmouth/Paducah Project Office (PPPO) (Joel Bradburne, Robert Edwards); PADUCAH (Jennifer Woodard, Myrna Espinosa Redfield); Depleted Uranium Hexafluoride Conversion Project (Reinhard Knerr, Zack Smith); Paducah Deactivation and Remediation Project (Myrna Espinosa Redfield); Mid-America Conversion Services - Seven Lines One Project (Zack Smith)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Airtightness Calculator for the US, Canada and China

The contribution of air leakage to heating and cooling loads has been increasing as the thermal resistance of building envelopes continues to improve. Easy-to-access data are needed to convince building owners and contractors that enhancing the airtightness of buildings is the next logical step to achieve a high-performance building envelope. To this end, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency Consortium partnered to develop an online calculator that estimates the potential energy savings in major US, Canadian, and Chinese cities due to improvements in airtightness. This tool will have user-friendly graphical interface that uses a database of CONTAM-EnergyPlus pre-run simulation results, and will be available to the public at no cost. Baseline leakage rates are either user-specified or the user selects them from the supplied typical leakage rates. Users will enter the expected airtightness after the proper installation of an air barrier system. Energy costs are estimated based on the building location and inputs from users. This paper provides an overview of the methodology that is followed in this calculator, as well as results from an example. The successful deployment of this calculator could influence construction practices so that greenhouse gas emissions from the US, Canada, and China are significantly curtailed.

air leakage↗

Energy Savings Impacts of Airtightness in U.S. Commercial Buildings

Air leakage in commercial buildings in the U.S. accounts for about one quad of energy annually. As the thermal resistance of commercial building envelopes continues to improve, the relative contribution of air leakage to heating and cooling loads is increasing. Several manufacturers have developed advance air barrier technologies and construction practices to reduce the air leakage in buildings. To help in the market penetration of these advance technologies, advances in easy to use tools for determining the impact of air leakage are needed. Oak Ridge National Laboratory (ORNL), the Air Barrier Association of America, the National Institute of Standards and Technology, and the US-China Clean Energy Research Center for Building Energy Efficiency partnered to develop an online calculator that estimates the potential energy and cost savings in major US, Canadian, and Chinese cities from improvements in airtightness. The calculator estimates the energy and cost savings potential based on the pre and post retrofit air leakage rates for prototype commercial buildings. This report explores extending these savings to determine the national level energy savings potential based on the weightage of commercial building type in different ASHRAE climate zone locations. The base infiltration rate of 1.07 CFM/ft2 was assumed for these calculations and the savings were calculated for three different air infiltration target rates of 0.4 CFM/ft2, 0.25 CFM/ft2, and 0.06 CFM/ft2. The national source energy savings of 238, 283, and 313 TBtu respectively were estimated for these target air infiltration rates.

Bhandari, Mahabir↗

pnnl/CPACE

C-PACE Market Assessment Tool This tool was developed for the U.S. Department of Energy’s Commercial Property Assessed Clean Energy (C-PACE) Working Group to support state and local governments creating, joining, and implementing C-PACE programs. This tool allows users to input a jurisdiction (city, county, or state) and automate a report with building characteristics, energy use, and energy efficiency savings opportunities for commercial buildings in that jurisdiction. The report generated by the tool identifies jurisdiction-specific energy end uses, building use types, and building technologies that a local C-PACE program should consider focusing on to more effectively allocate limited resources and maximize energy savings and investment.

Keene, Kevin↗

LNPK 156 Geothermal Coalition: Designing and Deploying Clean Energy in a Justice40 Cold Climate Community

The LNPK 156 Geothermal Coalition formed around the idea of building a new geothermal heating and cooling system in Duluth, MN for the Lincoln Park Justice40 neighborhood. The Coalition has been spearheaded by the City of Duluth and the local non-profit Ecolibrium3, and is named after the census tract of the neighborhood containing large portions of Lincoln Park, as well as a wastewater treatment plant, managed by the Western Lake Superior Sanitary District (WLSSD). The idea of building a geothermal system came to fruition over the period of about a decade, with repeated observations that the warm water discharged from the wastewater treatment plant was an energy-rich resource that has currently been untapped and released into the St. Louis River. The objective of this project was to build a geothermal system that harnesses wastewater heat recovery methods and satisfies the demand in a portion of Lincoln Park – a neighborhood experiencing high energy burdens, low life-expectancy, and where the natural gas and fuel oil used to heat homes and businesses results in decreased air quality and increased carbon emissions. The goal was to utilize this wastewater heat recovery method to benefit the neighborhood hosting the wastewater plant itself.

15 GEOTHERMAL ENERGY↗

Clean Energy to Communities: Technical Assistance for Region Five, MN

The Region Five Development Commission (“R5DC”) serves five counties in Minnesota, USA and received an Energizing Rural Communities Prize through the U.S. Department of Energy. Currently, R5DC is piloting projects in the City of Motley, for which two energy audits have been conducted. R5DC is seeking input regarding which options to pursue based on these two audits, as well a framework for future audits to be as effective and helpful as possible. This report defines a framework for future audits for R5DC, by providing an overview of the requirements for different levels of audits and identifying available resources for conducting energy audits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of the BERT Point Source Inversion Scheme Using the Joint Urban 2003 Tracer Experiment Dataset (Final Report)

A terrorist attack in a U.S. city utilizing biological weapons could have severe consequences. A biological agent could be aerosolized and emitted into the air in the middle of a city, invisibly traveling with the winds, and dosing an unknowing populace. The magnitude of the problem would only be revealed as sick people started arriving several days later at hospitals with symptoms, many already too ill to be saved. A national program has deployed a network of biological agent collectors in U.S. cities to provide early detection of a bio-weapon attack, thereby hastening medical intervention and potentially saving many thousands of lives. In fact, the most effective treatment takes place prior to infection or in its early stages and early warning might reduce the disease progression and, consequently, the possibility of an outbreak. If a biological attack were to occur in a city, one or more collectors may register hits with specific dosages and the city would be alerted that an attack had taken place. This piece of information alone, however, would not be enough to determine how serious the attack was, i.e., how much biological agent was released into the air and where the bio-plume traveled. The first responders and public health communities will want to know what regions were impacted, how many persons might get sick, which people most need medical supplies, and where to clean up. The law enforcement community will want to look for forensic evidence at the release location. The Bio-Agent Event Reconstruction Tool (BERT) has been developed in order to recreate what might have happened during an airborne biological agent attack based on biological agent collector measurements and wind collectors mounted around a city. The tool can be used to estimate possible release areas while eliminating other areas, and can estimate bounds on the amount of material released. The tool can then be used to project forward from the possible source areas to estimate potential hazard zones. Due to a unique source inversion technique - called the upwind collector footprint approach - the tool runs fast and the source regions can be determined in a few minutes. In this report, we provide an overview of the BERT framework, followed by a description of the source inversion technique. The Joint URBAN 2003 field experiment held in Oklahoma City that was used to validate BERT is then described. Subsequent sections describe the metrics used for evaluation, the comparison of the experimental data and BERT output, and under what conditions the BERT tool succeeds and performs poorly. Results are aggregated in different ways (e.g., daytime vs. nighttime releases, 1 vs. 2 vs. 3 hit collectors) to determine if BERT shows any systematic errors. Finally, recommendations are given for how to improve the code and procedures for optimizing performance in operational mode.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

2010 Dry and 2009 - 2010 Wet Season Branchiopod Survey Report, Site 300

Lawrence Livermore National Laboratory (LLNL) requested that Condor Country Consulting, Inc. (CCCI) perform wet season surveys and manage the dry season sampling for listed branchiopods in two ponded locations within the Site 300 Experimental Test Site. Site 300 is located in Alameda and San Joaquin Counties, located between the Cities of Livermore and Tracy. The two pool locations have been identified for possible amphibian enhancement activities in support of the Compensation Plan for impacts tied to the Building 850 soil clean-up project. The Building 850 project design resulted in formal consultation with the U.S. Fish and Wildlife Service (USFWS) as an amendment (File 81420-2009-F-0235) to the site-wide Biological Opinion (BO) (File 1-1-02-F-0062) in the spring of 2009 and requires mitigation for the California tiger salamander (AMCA, Ambystoma californiense) and California red-legged frog (CRLF, Rana draytonii) habitat loss. Both pools contain breeding AMCA, but do not produce metamorphs due to limited hydroperiod. The pool to the southeast (Pool BC-FS-2) is the preferred site for amphibian enhancement activities, and the wetland to northwest (Pool OA-FS-1) is the alternate location for enhancement. However, prior to enhancement, LLNL has been directed by USFWS (BO Conservation Measure 17 iii) to 'conduct USFWS protocol-level branchiopod surveys to determine whether listed brachiopod species are present within the compensation area.' CCCI conducted surveys for listed branchiopods in the 2009-2010 wet season to determine the presence of federally-listed branchiopods at the two pools (previous surveys with negative findings were performed by CCCI in 2001-2002 and 2002-2003 onsite). Surveys were conducted to partially satisfy the survey requirements of the USFWS 'Interim Survey Guidelines to Permittees for Recovery Permits under Section 10(a)(1)(A) of the Endangered Species Act for the Listed Vernal Pool Branchiopods' ('Guidelines, USFWS 1996 and BO Conservation Measure 17 iii). The dry sampling (included as an Appendix D) followed the wet season surveys in the summer of 2010.

54 ENVIRONMENTAL SCIENCES↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remediation of 130 mSv/hr. Soil Contamination Under a Hot Cell - 17301

Department of Energy (DOE) contractor CH2M HILL Plateau Remediation Company (CH2M) is currently engineering a system to safely remove and dispose of highly contaminated soil underneath Building 324 located adjacent to the Columbia River on the Hanford Site in Washington State. Cleaning up the waste site will allow for the eventual demolition of the building, which is a top priority for DOE and CH2M due to the proximity of the Columbia River and City of Richland. Building 324 at Hanford was originally constructed in 1966 and was operated for a number of years serving various missions. One of the missions involved development of treatment processes for liquid high activity waste. As of result of one particular mission, liquid high activity waste was spilled in one of the building's hot cells (known as 'B' Cell) and the liquid leaked from a breach in a sump and through construction joints in the hot cell floor and into the soil. Sampling efforts using borehole technology revealed significant under-building contamination with dose rates measuring has high as 130 mSv/hr (13,000 R/hr.). The Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) between the Washington State, Department of Ecology (Ecology), the U.S. Environmental Protection Agency and the DOE has established a 2021 milestone for demolition and removal of the Building 324. Before building demolition can be undertaken, the highly contaminated soil must be removed from beneath the hot cell while the hot cell structure remains in place to provide shielding and containment during the soil remediation. CH2M will fabricate and install remotely operated equipment that will remove debris and grout in the cell, the floor of the hot cell, and the contaminated soil beneath the hot cell and package that soil for disposal. To ensure that the structure remains intact and does not shift during soil removal, support for the building structure must also be constructed as a prerequisite for the planned work. CH2M will use a full-scale mock-up of the Building 324 B Cell and airlock area to assist in the testing of the remotely operated equipment and the training of the soil removal team in a contamination-free environment to ensure efficient and safe performance of the challenging work of the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗