Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charm++”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Lunar Regolith Albedos Using Monte Carlos

The analysis of planetary regoliths for their backscatter albedos produced by cosmic rays (CRs) is important for space exploration and its potential contributions to science investigations in fundamental physics and astrophysics. Albedos affect all such experiments and the personnel that operate them. Groups have analyzed the production rates of various particles and elemental species by planetary surfaces when bombarded with Galactic CR fluxes, both theoretically and by means of various transport codes, some of which have emphasized neutrons. Here we report on the preliminary results of our current Monte Carlo investigation into the production of charged particles, neutrons, and neutrinos by the lunar surface using FLUKA. In contrast to previous work, the effects of charm are now included.

Wilson, T. L.↗

Cryogenic Temperature-dependent Refractive Index Measurements of N-BK7, BaLKN3, and SF15 for NOTES PDI

In order to enable high quality lens designs using N-BK7, BaLKN3, and SF15 at cryogenic temperatures, we have measured the absolute refractive index of prisms of these three materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For N-BK7, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 50 to 300 K at wavelengths from 0.45 to 2.7 micrometers; for BaLKN3 we cover temperatures ranging from 40 to 300 K and wavelengths from 0.4 to 2.6 micrometers; for SF15 we cover temperatures ranging from 50 to 300 K and wavelengths from 0.45 to 2.6 micrometers. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. While we generally find good agreement (plus or minus 2 x 10(exp -4) for N-BK7, less than 1 x 10(exp -4) for the other materials) at room temperature between our measured values and those provided by the vendor, there is some variation between the datasheets provided with the prisms we measured and the catalog values published by the vendor. This underlines the importance of measuring the absolute refractive index of the material when precise knowledge of the refractive index is required.

Frey, Bradley J.↗

Temperature-dependent Absolute Refractive Index Measurements of Synthetic Fused Silica

Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from temperatures ranging from 30 to 310 K at wavelengths from 0.4 to 2.6 microns with an absolute uncertainty of plus or minus 1 x 10 (exp -5). Statistical variations in derived values of the thermo-optic coefficient (dn/dT) are at the plus or minus 2 x 10 (exp -8)/K level. Graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient are presented for selected wavelengths and temperatures along with estimates of uncertainty in index. Coefficients for temperature-dependent Sellmeier fits of measured refractive index are also presented to allow accurate interpolation of index to other wavelengths and temperatures. We compare our results to those from an independent investigation (which used an interferometric technique for measuring index changes as a function of temperature) whose samples were prepared from the same slugs of material from which our prisms were prepared in support of the Kepler mission. We also compare our results with sparse cryogenic index data from measurements of this material from the literature.

Leviton, Douglas B.↗

Temperature-dependent Refractive Index of Silicon and Germanium

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important in the field of infrared lens design. Optical instruments designed for the wavelength range where these two materials are transmissive achieve best performance when cooled to cryogenic temperatures to enhance signal from the scene over instrument background radiation. In order to enable high quality lens designs using silicon and germanium at cryogenic temperatures, we have measured the absolute refractive index of multiple prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For silicon, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 20 to 300 K at wavelengths from 1.1 to 5.6 pin, while for germanium, we cover temperatures ranging from 20 to 300 K and wavelengths from 1.9 to 5.5 microns. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. Citing the wide variety of values for the refractive indices of these two materials found in the literature, we reiterate the importance of measuring the refractive index of a sample from the same batch of raw material from which final optical components are cut when absolute accuracy greater than k5 x 10" is desired.

Frey, Bradley J.↗

Cryogenic Temperature-Dependent Refractive Index Measurements of CaF2 and Infrasil 301

In order to enable high quality lens design using calcium fluoride (CaF2) and Heraeus Infrasil 30 (Infrasil) at cryogenic temperatures, we have measured the absolute refractive index of prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For CaF2, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 25 to 300 K at wavelengths from 0.4 to 5.6 micrometers; for Infrasil we cover temperatures ranging from 35 to 300K and wavelengths from 0.4 to 3.6 micrometers. We investigate the interspecimen variability between measurements of two unrelated samples of CaF2, and we also compare our results for Infrasil to previous measurements fo Corning 7980 fused silica. Finally, we provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures and compare those results to other data found in the literature.

Frey, Bradley J.↗

Temperature-dependent Refractive Index of CaF2 and Infrasil 301

In order to enable high quality lens designs using calcium fluoride (CaF2) and Heraeus Infrasil 301 (Infrasil) for cryogenic operating temperatures, we have measured the absolute refractive index of these two materials as a function of both wavelength and temperature using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center. For CaF2, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 25 to 300 K at wavelengths from 0.4 to 5.6 pm, while for Infrasil, we cover temperatures ranging from 35 to 300 K and wavelengths from 0.4 to 3.6 pm. For CaF2, we compare our index measurements to measurements of other investigators. For Infrasil, we compare our measurements to the mate~al manufacturer's data at room temperature and to cryogenic measurements for fused silica from previous investigations including one of our own. Finally, we provide temperature-dependent Sellmeier coefficients based on our measured data to allow accurate interpolation of index to other wavelengths and temperatures.

Leviton, Douglas B.↗

Cryogenic Refractive Indices of S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14 Glasses

The Transiting Exoplanet Survey Satellite (TESS) is an explorer-class planet finder, whose principal goal is to detect small planets with bright host starts in the solar neighborhood. The TESS payload consists of four identical cameras and a Data Handling Unit (DHU) fitted with CCD detectors and associated electronics. Each camera consist of a lens assembly with seven optical elements that include various types of Ohara glass substrates. The successful implementation of a panchromatic and a thermal lens assembly design for these cameras requires a fairly accurate (up to 0.000001 (1e-6)) knowledge of the temperature- and wavelength-dependent of the refractive index in the wavelength and temperature range of operation. Hence, this paper is devoted to report on measurements of the refractive index over the wavelength range of 0.42-1.15 micrometers and temperature range of 110-300 K for the following Ohara glasses: S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14. The measurements were performed utilizing the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at NASA's Goddard Space Flight Center. A dense coverage of the absolute refractive index for all these substrates in the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dndT) and dispersion relation (dnd) as a function of wavelength and temperature. A comparison of the measured indices with literature values, specifically the temperature-dependent refractive indices of S-PHM52 and S-TIH14 reported by Yamamuro et al. [Yamamuro et al., Opt. Eng. 45(8), 083401 (2006)], will be presented.

cryogenic temperatures↗

Cryogenic Refractive Indices of S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14 Glasses

The Transiting Exoplanet Survey Satellite (TESS) is an explorer-class planet finder, whose principal goal is to detect small planets with bright host starts in the solar neighborhood. The TESS payload consists of four identical cameras with seven optical elements each that include various types of Ohara glass substrates. The successful implementation both panchromatic and thermal lens assembly designs for these cameras requires a fairly accurate (up to 1E-6) knowledge of the temperature and wavelength dependence of the refractive index in the wavelength and temperature range of operation. Hence, this paper is devoted to report on measurements of the refractive index over the wavelength range of 0.42-1.15 um and temperature range of 110-310 K for the following Ohara glasses: S-LAH55, S-LAH55V, SLAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14. The measurements were performed utilizing the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at NASA's Goddard Space Flight Center. A dense coverage of the absolute refractive index for the title substrates in the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/d lambda) as a function of wavelength and temperature. A comparison of the measured indices with literature values, specifically the temperature-dependent refractive indices of S-PHM52 and S-TIH14, will be presented.

geometrical optics↗

Cryogenic Refractive Index and Coefficient of Thermal Expansion for the S-TIH1 Glass

Using the CHARMS facility at NASA GSFC, we have measured the cryogenic refractive index of the Ohara S-TIH1 glass from 0.40 to 2.53 micrometers and from 120 to 300 K. We have also examined the spectral dispersion and thermo-optic coefficients (dn/dT). We also derived temperature-dependent Sellmeier models from which refractive index may be calculated for any wavelength and temperature within the stated ranges of each model. The S-TIH1 glass we tested exhibited unusual behavior in the thermo-optic coefficient. We found that for delta < 0.5 micrometers, the index of refraction decrease with a decrease in temperature (positive dn/dT). However, the situation was reversed for delta larger than 0.63 micrometers, where the index will increase with a decrease in temperature (negative dn/dT). We also measured the coefficient of thermal expansion (CTE) for the similar batch of S-TIH1 glass in order to understand its thermal properties. The CTE showed a monotonic change with a decrease in temperature.

Quijada, Manuel A.↗

An Optimal Estimation Aerosol Retrieval Algorithm for Lidar-only and Combined Lidar Polarimeter Remote Sensors

Global measurements of aerosol vertical profile, composition, concentration, and size distribution are very important due to aerosol impacts on air quality, climate, clouds, and ocean ecosystems. We have developed a lidar-only and combined lidar and polarimeter algorithm to retrieve vertically-resolved profiles of aerosol microphysical properties. The new retrieval system is modular in design. It consists of three modules, a vertically-resolved aerosol profile retrieval module for lidar data, an aerosol and cloud/ocean retrieval module for polarimeter data, and a combined retrieval module for both lidar and polarimeter measurements. In addition to performing optimal estimation retrievals on various data sources, we have designed the system so that it can be used to carry out aerosol retrieval performance trade studies for various lidar and polarimeter configurations. For example, the retrieval system can take inputs from attenuated backscatter lidar at two wavelengths (e.g. CALIPSO like instrument), aerosol backscattering measured at two wavelengths and and aerosol extinction measured at one wavelength (HSRL-1), or aerosol backscattering measured at three wavelengths and aerosol extinction measured at two wavelengths (HSRL-1) (HSRL-2). We have applied the lidar-only algorithm to both simulated data and various field campaign data (DISCOVER-AQ, CHARMS, TCAP, and ORACLES). For polarimeter-only modules, we have done the same for SABOR, TCAP, NAAMES, and ORACLES data. We have applied the combined retrieval algorithm to ORACLES data. The simulated retrieval studies show that the combined lidar+polarimeter retrieval provides much higher information content relative to their individual counterparts for retrieving effective radius, particle concentrations, and absorption properties.

Xu Liu↗

Aeroservoelastic Flight Dynamic Modeling of UAM Conceptual Vehicles

This paper presents an aeroservoelastic flight dynamic modeling approach for NASA Lift+Cruise eVTOL aircraft in forward flight. A conceptual aerodynamic analysis for forward flight is performed in CHARM, a rotorcraft aeromechanics unsteady vortex-lattice flow solver. A trim analysis is performed to obtain the steady state aerodynamic information at a trim point to be used for the aeroelastic analysis. A NASTRAN finite element model for the Lift+Cruise vehicle is available. The structural dynamic mode shapes are extracted from the NASTRAN for the aeroelastic analysis. An aeroservoelastic model is developed using the Theodorsen’s theory. A stability and control derivative analysis is performed to formulate a flight dynamic model of the Lift+Cruise vehicle. An aeroservoelastic flight dynamic model is formulated by coupling these two models together. Flight dynamic and flutter analyses are performed to determine vehicle stability and flutter-free operation.

Aeroservoelasticity↗

Cryogenic High Accuracy Refraction Measurements Capabilities and New FUV Coating Mirror Technology Developments

This talk will emphasize the basic principles of refractive materials used in an optical telescope. In particular, the presentation will describe refractive index measurements that were performed for one of the instruments on the James Webb Space Telescope (JWST). A refractive system design was implemented in the Near-Infrared Camera (NIRCam) which is one of the main instruments on the JWST observatory. This camera was designed to make observations in the infrared part of the optical spectrum, and it is required to operate in a space environment at temperatures as low as 25K. Therefore, it was imperative to know the refractive index at those low cryogenic temperatures for the various glass substrates (ZnSe, LiF and BaF2) used in the system design of NIRCam. These cryogenic index of refraction measurements were carried out by using the world-class refractometer called the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility that was designed and built at the Goddard Space Flight Center (GSFC) in Greenbelt, MD. In the second part, there will be a discussion of the recent advances on the research and development activities of advanced and new mirror coating technologies that provide high reflectance performance in the far-ultraviolet (FUV) part of the optical spectrum. These new mirror coatings are envisioned for use on the reflecting mirrors of the next mission (beyond JWST) that will focus on astronomical observations in the FUV spectral range to deliver new and exciting discoveries about the origin of the cosmos.

Astronomy↗

Best Practices for Predicting Acoustics of a Single Rotor Using the NASA RVLT Conceptual Design Toolchain

To facilitate the development of the Urban Air Mobility (UAM) market, the NASA Revolutionary Vertical Lift Technology Project has created the Conceptual Design Toolchain, a suite of tools developed and/or selected to assist rotorcraft designers in all stages of rotorcraft design. Of particular interest to the UAM noise community are the following two steps in this toolchain: comprehensive analysis and acoustic prediction. Since the UAM application is relatively new, there is a need for a systematic study on how best to utilize these codes. To this end, the current study documents best practices for using the comprehensive analysis codes, CAMRAD II and CHARM, along with the acoustic code AARON. Two single rotors are considered: i) a simple rotor and ii) a rotor that is more exemplary of what UAM designers might use. Best practices are presented for the prediction of both tonal and broadband self-noise, along with the corresponding results. The goal is to provide conceptual designers the tools to conduct accurate noise prediction using the RVLT Conceptual Design Toolchain.

Acoustics↗

A Forward Multiparticle Spectrometer for the LHC: Hadron spectra and Long-lived particle search

I describe a possible Forward Multiparticle Spectrometer (FMS) that could be installed downstream of the superconducting recombination dipole D1 in Run 4, from z = 96 m - 126 m to measure multi-TeV hadron spectra in low luminosity p + p collisions at Rt(s) = 14 TeV, as well as p + O and O + O collisions as relevant for cosmic ray showers. Light antinuclei and charmed hadrons at high Feynman xF can be measured, both of importance for astrophysics. At the full high luminosity HL-LHC a search for new long-lived neutral particles (LLPs) decaying in a 20 m long, 70 cm diameter vacuum pipe to visible decay modes (including gamma+gamma, e+e-, mu+mu-, tau+tau-, ccbar and jets) can be made. The FMS is especially well suited for LLPs with 1 GeV < M(X)< 10 GeV and lifetimes c.tau from about 10 m to several km. I discuss this as a possible addition to CMS but it has no formal approval yet, therefore the talk is not given on behalf of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NNLO constraints on proton PDFs from the SeaQuest and STAR experiments and other developments in the CTEQ-TEA global analysis

We review progress in the global QCD analysis by the CTEQ-TEA group since the publication of CT18 parton distribution functions (PDFs) in the proton. Specifically, we discuss comparisons of CT18 NNLO predictions with the LHC 13 TeV measurements as well as with the FNAL SeaQuest and BNL STAR data on lepton pair production. The specialized CT18X PDFs approximating saturation effects are compared with the CT18sx PDFs obtained using NLL/NLO small-$x$ resummation. Short summaries are presented for the special CT18 parton distributions with fitted charm and with lattice QCD inputs. A recent comparative analysis of the impact of deuteron nuclear effects on the parton distributions by the CTEQ-JLab and CTEQ-TEA groups is summarized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

B- and D-meson semileptonic decays with highly improved staggered quarks

We present results for $B_{(s)}$- and $D_{(s)}$-meson semileptonic decays from ongoing calculations by the Fermilab Lattice and MILC Collaborations. Our calculation employs the highly improved staggered quark (HISQ) action for both sea and valence quarks and includes several ensembles with physical-mass up, down, strange, and charm quarks and lattice spacings ranging from $a\approx0.15$ fm down to 0.06 fm. At most lattice spacings, an ensemble with physical-mass light quarks is included. The use of the highly improved action, combined with the MILC Collaboration's gauge ensembles with lattice spacings down to $a\approx0.042$ fm, allows heavy valence quarks to be treated with the same discretization as the light and strange quarks. This unified treatment of the valence quarks allows (in some cases) for absolutely normalized currents, bypassing the need for perturbative matching, which has been a leading source of uncertainty in previous calculations of $B$-meson decay form factors by our collaboration. All preliminary form-factor results are blinded.

Jay, William I.↗

The static energy in 2+1+1-flavor QCD

We report on the status of the analysis of the static energy in $2+1+1$-flavor QCD. The static energy is obtained by measuring Wilson line correlators in Coulomb gauge using the HISQ action, yielding the scales $r_{0}/a$, $r_{1}/a$, $r_{2}/a$, their ratios, and the string tension $\sigma r_{i}^{2}$. We put emphasis on the possible effects due to the dynamical charm-quark by comparing the lattice results to continuum results of the static energy with and without a massive flavor at two-loop accuracy. We employ gauge-field ensembles from the HotQCD and MILC Collaborations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global analyses of nuclear PDFs with heavy-quark and neutrino data

We discuss the two most recent global analyses of nuclear parton distribution functions within the nCTEQ approach. LHC data on $W/Z$-boson, single-inclusive hadron and heavy quark/quarkonium production are shown to not only significantly reduce the gluon uncertainty down to $x\geq10^{-5}$, but to also influence the strange quark density. The latter is further constrained by neutrino deep-inelastic scattering and charm dimuon production data, whose consistency with neutral-current experiments is also re-evaluated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗