Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Advanced indium antimonide monolithic charge coupled infrared imaging arrays

The continued process development of SiO2 insulators for use in advanced InSb monolithic charge coupled infrared imaging arrays is described. Specific investigations into the use of plasma enhanced chemical vapor deposited (PECVD) SiO2 as a gate insulator for InSb charge coupled devices is discussed, as are investigations of other chemical vapor deposited SiO2 materials.

Koch, T. L.↗

High speed techniques for synthetic aperture radar image formation

One possible approach to high speed synthetic aperture radar signal reconstruction involves the utilization of two dimensional real time spatial light modulators as recyclable replacements for photographic film in the input transducer plane of a modified synthetic aperture radar (SAR) coherent optical processor. Leading candidate spatial light modulators include modified Pockels readout optical modulators (PROM), charge coupled devices (CCD) addressed liquid crystal light valves, and CCD addressed membrane light modulators. The fundamental physical limitations affecting SAR processor performance characteristics of such real time devices are under investigation. Current research on PROM is focused on the effects of device operatonal mode, device constitutive parameters, electro-optic crystal orientation, writing wavelength, frame rate/data overwrite/presuming, erasure completeness, and image retention on the overall quality of SAR image formation. Both modulated laser scanning and intensified CRT temporal to spatial input approaches are being examined.

Psaltis, D.↗

Optical implementation of systolic array processing

Algorithms for matrix vector multiplication are implemented using acousto-optic cells for multiplication and input data transfer and using charge coupled devices detector arrays for accumulation and output of the results. No two dimensional matrix mask is required; matrix changes are implemented electronically. A system for multiplying a 50 component nonnegative real vector by a 50 by 50 nonnegative real matrix is described. Modifications for bipolar real and complex valued processing are possible, as are extensions to matrix-matrix multiplication and multiplication of a vector by multiple matrices.

Caulfield, H. J.↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

Detection of the underlying galaxy in the QSO 3C48

Observation of the quasar 3C48 reveals that the faint nebulosity to the north and south of it is dominated by starlight and that the stars have a redshift close to that determined from the broad emission lines in the quasar spectrum. This provides the first direct evidence that a quasar is associated with a galaxy and lies at a distance corresponding to its redshift. The observations were made with a combination of a spectrograph and a charge-coupled device as a detector and took two hours of telescope time. A continuum with absorption features was seen as indicative of a young, hot stellar population. While the redshift of the underlying galaxy is the same as that of the permitted lines in the quasar, it differs from the redshift of the forbidden lines by 500 km/s.

Boroson, T. A.↗

The great galactic centre mystery

Gamma-ray observations of the center of the Galaxy show a varying positron-electron annihilation radiation emission, while at radio wavelengths a non-thermal compact source surrounded by ionized gas moving at high velocities can be seen. Line emission maps for atomic and ionized hydrogen and molecular gas suggest gas expulsion and a massive collapsed object. IR observations show that ionized gas in the central few parsecs of the Galactic center is concentrated in at least 14 small clouds. Charge-coupled device images show a pair of faint, very red sources within a few arc seconds of IRS 16 and the compact non-thermal radio source. The positron-electron annihilation line emission implies an annihilation rate of 10 to the 43rd per sec, compared with an observed luminosity at IR wavelengths of 10 to the 40 erg per sec. Some models are briefly discussed.

Riegler, G. R.↗

Spatially resolved methane band photometry of Saturn. I - Absolute reflectivity and center-to-limb variations in the 6190-, 7250-, and 8900-A bands

Spatially resolved measurements of Saturn's absolute reflectivity in methane bands at 6190, 7250, and 8900 A and in nearby continuum regions are presented. Images were obtained through narrow-band interference filters with a 500 x 500-pixel charge-coupled device. Band/continuum ratios were measured to high accuracy by referencing to the ring brightness in each image. Several data processing techniques enhanced the quality of the observations. These are the use of the ring symmetry to find center position and orientation, accurate subtraction of ring light, and constrained image deconvolution. Uncertainty in the continuum absolute reflectivity is within 10%. Uncertainties in band/continuum ratios are from one to several percent. The Equatorial Zone was much brighter than any other latitude in the strong 8900 band image. Northern midlatitudes were brighter than southern midlatitudes. The latter observation indicates fewer high-altitude aerosols in the south, a possible result of atmospheric dynamics or seasonal sublimation of NH3 crystals. The data are tabulated and presented in a form suitable for quantitative scattering model analyses.

West, R. A.↗

Eliminating "Hotspots" in Digital Image Processing

Signals from defective picture elements rejected. Image processing program for use with charge-coupled device (CCD) or other mosaic imager augmented with algorithm that compensates for common type of electronic defect. Algorithm prevents false interpretation of "hotspots". Used for robotics, image enhancement, image analysis and digital television.

Salomon, P. M.↗

High density Schottky barrier IRCCD sensors for SWIR applications at intermediate temperature

Monolithic 32 x 64 and 64 x 1:128 palladium silicide (Pd2Si) interline transfer infrared charge coupled devices (IRCCDs) sensitive in the 1 to 3.5 micron spectral band were developed. This silicon imager exhibits a low response nonuniformity of typically 0.2 to 1.6% rms, and was operated in the temperature range between 40 to 140 K. Spectral response measurements of test Pd2Si p-type Si devices yield quantum efficiencies of 7.9% at 1.25 microns, 5.6% at 1.65 microns 2.2% at 2.22 microns. Improvement in quantum efficiency is expected by optimizing the different structural parameters of the Pd2Si detectors. The spectral response of the Pd2Si detectors fit a modified Fowler emission model. The measured photo-electric barrier height for the Pd2Si detectors is 0.34 eV and the measured quantum efficiency coefficient, C1, is 19%/eV. The dark current level of Pd2Si Schottky barrier focal plane arrays (FPAs) is sufficiently low to enable operation at intermediate temperatures at TV frame rates. Typical dark current level measured at 120 K on the FPA is 2 nA/sq cm. The operating temperature of the Pd2Si FPA is compatible with passive cooler performance. In addition, high density Pd2Si Schottky barrier FPAs are manufactured with high yield and therefore represent an economical approach to short wavelength IR imaging. A Pd2Si Schottky barrier image sensor for push-broom multispectral imaging in the 1.25, 1.65, and 2.22 micron bands is being studied. The sensor will have two line arrays (dual band capability) of 512 detectors each, with 30 micron center-to-center detector spacing. The device will be suitable for chip-to-chip abutment, thus providing the capability to produce large, multiple chip focal planes with contiguous, in-line sensors.

Elabd, H.↗

Electron-bombarded CCD detectors for ultraviolet atmospheric remote sensing

Electronic image sensors based on charge coupled devices operated in electron-bombarded mode, yielding real-time, remote-readout, photon-limited UV imaging capability are being developed. The sensors also incorporate fast-focal-ratio Schmidt optics and opaque photocathodes, giving nearly the ultimate possible diffuse-source sensitivity. They can be used for direct imagery of atmospheric emission phenomena, and for imaging spectrography with moderate spatial and spectral resolution. The current state of instrument development, laboratory results, planned future developments and proposed applications of the sensors in space flight instrumentation is described.

Carruthers, G. R.↗

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

NASA-Texas Planetary Program

Astronomical observations performed at the McDonald Observatory were summarized. Various spectra obtained from Jupiter, Uranus, Saturn, Neptune, Pluto, Titan, Iapetus, and sundry asteroids were described briefly. Spectra taken of various comets using an IDS (Intensified Dissector Scanner) spectrograph on a 2.7 m telescope were reviewed. The Octicon, a linear array of eight 1872-element Reticon arrays that was installed in the 2.7 m coude spectrograph at the observatory, was described. The 2.7 m coude scanner, 2.7 m coude CCD (charge coupled device), and 2.7 m radial velocity spectrometer were mentioned.

Smith, H. J.↗

Multispectral linear array focal plane

A description is provided of a sensor chip array for a unified multispectral focal plane for the Multispectral Linear Array (MLA) instrument. The involved concept of sensing multispectral earth resources imagery through the use of spectral filters deposited directly on a single row of silicon charge-coupled device (CCD) chips has been considered for a number of years. A simplified focal plane was designed after a number of experiments. Technology considerations regarding the design of the multispectral focal plane are discussed. Experimental data are presented which show that the arising problems have been or can be solved.

Hall, J. A.↗

Evaluation of spacecraft materials and processes for optical degradation potential

A Wide Field Planetary Camera instrument with wide wavelength sensitive Charged Coupled Device detectors has been designed and built for employment in space. The contamination potential of the spacecraft hardware is determined by the outgassing characteristics of the selected materials and the effect of the performed processing procedures. An investigation was conducted to provide for more selective material screening with respect to contamination potential and to develop an optical effects data base. In the investigation, a series of thermogravimetric, residual gas, Micro-Volatile Condensible Material (VCM), and Vacuum Optical Degradation tests were performed. The results of the Micro-VCM testing of four epoxy adhesive systems are presented in tables.

Odonnell, T.↗

Restored methane band images of Uranus and Neptune

Charge-coupled device images of Uranus and Neptune taken in the 8900-A absorption band of methane are presented. The images have been digitally processed by means of nonlinear deconvolution techniques to partially remove the effects of atmospheric seeing. The restored Uranus images show strong limb brightening consistent with previous observations and theoretical models of the planet's atmosphere. The computer-processed images of Neptune show discrete cloud features similar to those reported previously by Smith, Reitsema, and Larson (1979). A time series of the restored Neptune images shows a continuous variation which may be due to the planet's rotation.

Heasley, J. N.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Comet Bowell (1980b) - Measurement of the optical thickness of the coma and particle albedo from a stellar occultation

Comet Bowell (1980b) was observed to pass within 0.25 + or 0.09 arc sec of a star (about 540 km at the comet), where the absorption of starlight by the dust coma was found to be 3 percent (+ or - 1 percent). The implied optical thickness of 0.03 differs greatly from other determinations and gives a mass of 3 x 10 to the 13th g for the coma within 10,000 km of the nucleus. Coupled with absolute continuum filter photometry, these results indicate a very low particle albedo consistent with fluffy carbonaceous material. This experiment indicates the need to observe nearly central occultations by several observers to measure the optical thickness profile of a comet. The advantages of using a charge-coupled device area photometer for such observations are discussed.

Larson, S. M.↗

Fiber optics for astronomical spectroscopy - The Medusa Spectrograph

An instrument has been built to obtain simultaneous spectra of 32 objects in the field of view of the Steward Observatory 2.3 m telescope. Short lengths of optical fiber are used to bring light from galaxy images at the focus of the telescope into a line at the spectrograph slit. This multi-fiber aperture plate instrument has been dubbed the Medusa Spectrograph. The Medusa is now producing spectra of about 100 galaxies per clear night. An optimized version of the instrument called the MX Spectrometer is being constructed to record spectra at a higher rate. This new instrument will have remotely positioned fibers under computer control. A Charge Coupled Device will be used as the spectrograph detector to allow sky subtraction, give increased dynamic range and provide more accurate wavelength calibration. Transmission characteristics of some commercial fibers are discussed, and the microlens optics used to match the telescope and the spectrograph to the fibers to avoid focal ratio degradation are described.

Hill, J. M.↗