At least 397 records · Page 22

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.

Bandler, S. R.↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Background Gamma Spectrometry for the International Monitoring System

PNNL has developed two very low-background gamma detectors housed in a new shallow underground laboratory. This new capability significantly improves our ability to detect trace amounts of airborne particulate that may be present in samples from the IMS field stations. The detectors were custom ordered to be fabricated using very low background materials. The combination of cosmic veto panels, dry nitrogen gas to reduce radon, low background shielding, and the shallow underground laboratory results in a reduction of the background count rate by a factor of 100 compared to an off –the-shelf commercial gamma detector operating above ground at our laboratory. Detection limits are thus reduced an order of magnitude.

gamma specgtroscopy, lo↗

In-situ observations of a bi-modal ion distribution in the outer coma of comet P/Halley

Observations obtained by the Johnstone Plasma Analyzer on the Giotto fly-by of comet Halley showed a fairly sudden decrease in the count rate of energetic (about 30 KeV) water-group ions inside about 500,000 km from the nucleus. This decrease was accompanied by the appearance of a new water-group ion population at slightly lower energies (less than 10 KeV). Close inspection reveals that this lower-energy peak was also present somewhat earlier in the postshock flow but only became prominent near the sudden transition just described. It is shown that the observed bimodal ion distribution is well explained in terms of the velocity history of the accreting solar wind flow in the outer coma. The decline in count rate of the energetic pick-up distribution is due to a relatively sudden slowing of the bulk flow there and not to a loss of particles. Hence, charge-exchange cooling of the flow is probably not important at these distances from the nucleus. The observations suggest that pitch-angle scattering is fairly efficient at least after the bow shock, but that energy diffusion is probably not very efficient.

Thomsen, M. F.↗

On the Nature of the mHz X-ray Quasi-Periodic Oscillations from Ultraluminous X-ray source M82 X−1: Search for Timing-Spectral Correlations

Using all the archival XMM-Newton X-ray (3-10 keV) observations of the ultraluminous X-ray source (ULX) M82 X−1, we searched for a correlation between its variable mHz quasi-periodic oscillation (QPO) frequency and its hardness ratio (5-10 keV/3-5 keV), an indicator of the energy spectral power-law index. When stellar-mass black holes (StMBHs) exhibit type-C low-frequency QPOs (∼0.2-15 Hz), the centroid frequency of the QPO is known to correlate with the energy spectral index. The detection of such a correlation would strengthen the identification of M82 X−1's mHz QPOs as type-C and enable a more reliable mass estimate by scaling its QPO frequencies to those of type-C QPOs in StMBHs of known mass.We resolved the count rates and the hardness ratios of M82 X−1 and a nearby bright ULX (source 5/X42.3+59) through surface brightness modeling.We detected QPOs in the frequency range of 36-210 mHz during which M82 X−1's hardness ratio varied from 0.42 to 0.47. Our primary results are (1) that we do not detect any correlation between the mHz QPO frequency and the hardness ratio (a substitute for the energy spectral power-law index) and (2) similar to some accreting X-ray binaries, we find that M82 X−1's mHz QPO frequency increases with its X-ray count rate (Pearson's correlation coefficient = +0.97). The apparent lack of a correlation between the QPO centroid frequency and the hardness ratio poses a challenge to the earlier claims that the mHz QPOs of M82 X−1 are the analogs of the type-C low-frequency QPOs of StMBHs. On the other hand, it is possible that the observed relation between the hardness ratio and the QPO frequency represents the saturated portion of the correlation seen in type-C QPOs of StMBHs-in which case M82 X−1's mHz QPOs can still be analogous to type-C QPOs.

Nature↗

Radiation Source Localization Using Surrogate Models Constructed from 3-D Monte Carlo Transport Physics Simulations

Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A NanoSIMS 50 L Investigation into Improving the Precision and Accuracy of the 235U/238U Ratio Determination by Using the Molecular 235U16O and 238U16O Secondary Ions

A NanoSIMS 50 L was used to study the relationship between the 235U/238U atomic and 235U16O/238U16O molecular uranium isotope ratios determined from a variety of uranium compounds (UO2, UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4) and silicates (NIST-610 glass and the Plesovice zircon reference materials, both containing µg/g uranium). Because there is typically a greater abundance of 235U16O+ and 238U16O+ molecular secondary ions than 235U+ and 238U+ atomic ions when uranium-bearing materials are sputtered with an oxygen primary ion beam, the goal was to understand whether use of 235U16O/238U16O has the potential for improved accuracy and precision when compared to the 235U/238U ratio. The UO2 and silicate reference materials showed the greatest potential for improved accuracy and precision through use of the 235U16O/238U16O ratio as compared to the 235U/238U ratio. For the UO2, which was investigated at a variety of primary beam currents, and the silicate reference materials, which were only investigated using a single primary beam current, this improvement was especially pronounced at low 235U+ count rates. In contrast, comparison of the 235U16O/238U16O ratio versus the 235U/238U ratio from the other uranium compounds clearly indicates that the 235U16O/238U16O ratio results in worse precision and accuracy. This behavior is based on the observation that the atomic (235U+ and 238U+) to molecular (235U16O+ and 238U16O+) secondary ion production rates remain internally consistent within the UO2 and silicate reference materials, whereas it is highly variable in the other uranium compounds. Efforts to understand the origin of this behavior suggest that irregular sample surface topography, and/or molecular interferences arising from the manner in which the UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4 were prepared, may be a major contributing factor to the inconsistent relationship between the observed atomic and molecular secondary ion yields. Overall, the results suggest that for certain bulk compositions, use of the 235U16O/238U16O may be a viable approach to improving the precision and accuracy in situations where a relatively low 235U+ count rate is expected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE LIGHT CURVE OF HERCULES X-1 AS OBSERVED BY THE ROSSI X-RAY TIMING EXPLORER

Analysis of the light curve of Hercules X-1 using the full set of archival observations of Hercules X-1 by the Rossi X-Ray Timing Explorer/Proportional Counter Array (RXTE/PCA) is reported. The observations cover time periods that Her X-1 is in main high, short high, and low states, and an anomalous low state (ALS). They include over 1.4 Ms of net exposure time. We present 35 day and orbital phase folded light curves of the count rates and softness ratios, showing the range of behaviors of Her X-1 with the high sensitivity of the RXTE/PCA. New phenomena are uncovered and previous phenomena are seen in greater detail. For both main high and short high states, the fraction of time in dips is found to be a function of orbital phase and of 35 day phase. It increases steadily with orbital phase past orbital phase 0.3 and is higher at the start and end of both main high and short high states. It is higher for short high state (62%) than for main high state (28%). The normal low state data and ALS data are compared: the low state count rate is {approx}twice as high as for ALS data. The 2-4 keV to 9-20 keV softness ratio changes smoothly with orbital phase for low states and ALSs, and is indistinguishable between the two, yet very different than for the high states. This supports models for which the cause of the ALS is changed disk geometry that prevents a direct line of sight from neutron star to observer at all 35 day phases.

79 ASTRONOMY AND ASTROPHYSICS↗

A component of nongyrotropic (phase-bunched) electrons upstream from the earth's bow shock

The count rates of 1.5- and 6-keV electrons measured on ISEE 1 and ISEE 2 are at times strongly spin modulated despite the fact that the axes of the detectors lie along the spin axis of the spacecraft. Spatial gradients in the guiding center density are ruled out as a cause of the spin modulation. The characteristics of the spin modulation can be explained if the electron velocity distribution is nongyrotropic. The procedure is to show that the direction of the plasma flow velocity during times of spin modulation does not lie along the direction of the local magnetic field when both are projected onto the ecliptic plane. While a gyrotropic distribution will cause spin modulation, the count rate maximum will correspond to the direction of the local magnetic field. Gyrophase-bunched electrons are seen within a few tens of kilometers of the shock and as far upstream as 30,000 km from the shock, suggesting that a wave is associated with their propagation. The magnetosheath electrons in the same energy range are also nongyrotropic at times.

Anderson, K. A.↗

Fundamental Equations of the LIF Hydroxyl Measurements, Appendix a

The equation relating OH concentration to the observed detector count rate for a given laser flux is defined. That equation, which will be referred to henceforth as the central equation for absolute sensitivity, will be cast in terms of standard spectroscopic quantities such as oscillator strengths, Hoenl-London factors, rotational and vibrational quantum numbers, etc., such that it may be tested directly under laboratory conditions. The working expressions used by each of the OH laser induced fluorescence (LIF) groups will be related to this central equation, thereby establishing a common language for the comparison of experimental results and the definition of LIF system performance. The relevant structural details of the OH radical via a spectroscopic description of the energy levels and transitions employed in the LIF method are detailed. The central equation relating observed count rate to absolute concentration will be derived, and that equation will be related to the observed quantities cited by each of the experimental groups engaged in the measurement of OH in the Earth's atmosphere.

Source record↗

Performance Assessment of Different Pulse Reconstruction Algorithms for the ATHENA X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.

microcalorimeters↗

Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Measurement and Analysis of Gamma-Rays Emitted From Spent Nuclear Fuel Above 3 MeV

The gamma-ray spectrum of spent nuclear fuel in the 3- to 6-MeV energy range is important for active interrogation since emitted gamma rays emitted from nuclear decay are not expected to interfere with measurements in this energy region. There is, unfortunately, a dearth of empirical measurements from spent nuclear fuel in this region. This work is an initial attempt to partially ll this gap by presenting an analysis of gamma-ray spectra collected from a set of spent nuclear fuel sources using a high-purity germanium detector array. This multi-crystal array possesses a large collection volume, providing high energy resolution up to 16 MeV. The results of these measurements establish the continuum count-rate in the energy region between 3- and 6-MeV. Also assessed is the potential for peaks from passive emissions to interfere with peak measurements resulting from active interrogation delayed emissions. As one of the first documented empirical measurements of passive emissions from spent fuel for energies above 3 MeV, this work provides a foundation for active interrogation model validation and detector development.

delayed gamma rays↗

Evaluating the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks

In this work the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks is evaluated. The first one code based on traditional iterative procedures and called Neutron spectrometry and dosimetry from the Universidad Autonoma de Zacatecas (NSDUAZ) use the SPUNIT iterative algorithm and was designed to unfold neutron spectrum and calculate 15 dosimetric quantities and 7 IAEA survey meters. The main feature of this code is the automated selection of the initial guess spectrum trough a compendium of neutron spectrum compiled by the IAEA. The second one code known as Neutron spectrometry and dosimetry with artificial neural networks (NDSann) is a code designed using neural nets technology. The artificial intelligence approach of neural net does not solve mathematical equations. By using the knowledge stored at synaptic weights on a neural net properly trained, the code is capable to unfold neutron spectrum and to simultaneously calculate 15 dosimetric quantities, needing as entrance data, only the rate counts measured with a Bonner spheres system. Similarities of both NSDUAZ and NSDann codes are: they follow the same easy and intuitive user's philosophy and were designed in a graphical interface under the LabVIEW programming environment. Both codes unfold the neutron spectrum expressed in 60 energy bins, calculate 15 dosimetric quantities and generate a full report in HTML format. Differences of these codes are: NSDUAZ code was designed using classical iterative approaches and needs an initial guess spectrum in order to initiate the iterative procedure. In NSDUAZ, a programming routine was designed to calculate 7 IAEA instrument survey meters using the fluence-dose conversion coefficients. NSDann code use artificial neural networks for solving the ill-conditioned equation system of neutron spectrometry problem through synaptic weights of a properly trained neural network. Contrary to iterative procedures, in neural net approach it is possible to reduce the rate counts used to unfold the neutron spectrum. To evaluate these codes a computer tool called Neutron Spectrometry and dosimetry computer tool was designed. The results obtained with this package are showed. The codes here mentioned are freely available upon request to the authors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of Circumstellar Matter Surrounding the Hercules X-1 System

We analyze data from two eclipse ingresses of Her X-1 observed with Ginga on 1989 April 30 and May 19. These observations occur, respectively, during the MAIN HIGH and SHORT HIGH states in the 35 day modulation of Her X-1 intensity. We find significant residual X-ray flux during eclipse, with a gradual decrease in flux following the occultation of the neutron star by the atmosphere of HZ Her. During the central part of the eclipse the count rate becomes nearly constant, at 0.5 mcrab in the energy range 1.7-36.8 keV. From a spec- tral analysis of the residual emission during the total eclipse of the central source in the MAIN MGH state, we determine the energy spectral index, alpha = 0.8, similar to that before eclipse. A remarkable feature of the eclipse spectrum is that it does not show a significant iron line feature in contrast to massive wind-fed pulsars, such as Vela X-1 and Cen X-3. From a timing analysis of the same eclipse data, we show that there are no pulses. These results imply that the emission comes from the scattering of continuum X-rays by material in a region considerably larger than the companion star. An extended accretion disk corona may be responsible for this scattering. However, partial eclipse of an extended accretion disk corona is insufficient to account for the count rates in mid-eclipse, when known parameters of the binary system are used. Based on the present results, we suggest that scattering occurs not only in the accretion disk corona but also in the circumstellar matter surrounding the system of Her X-1/HZ Her.

Choi, C. S.↗