Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAINER SAMPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Short-Range Order in α-FeAl Soft Magnetic Alloy

The atomic structure of iron–aluminum alloy samples containing about 7 at % of aluminum (α region of the phase diagram) was investigated by X-ray diffraction. The samples were annealed in the paramagnetic (T > {sup T}{sub C}) and ferromagnetic (T < T{sub C}) states. In the first case, the structural state was fixed by quenching from the annealing temperature in water, and, in the second case, by slow cooling. Diffraction patterns of single-crystal samples were taken on an X-ray four-circle diffractometer. It is shown that local ordering, regardless of the prehistory of a sample, is a combination of B2-phase clusters (the CsCl type structure), which were previously found in iron–silicon alloys with Si content up to 10%, and small regions with D0{sub 3} short-range order. The former consist of two B2-cells having a common face, while the latter consist predominantly of one unit cell of the D0{sub 3}-phase. Within the accuracy of the experiment, no significant difference in the structural states in the paramagnetic and ferromagnetic phases was observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report on Status of Shipment of High Fluence Austenitic Steel Samples for Characterization and Stress Corrosion Crack Testing

The goal of the Mechanisms of Irradiation Assisted Stress Corrosion Cracking (IASCC) task in the LWRS Program is to conduct experimental research into understanding how multiple variables influence the crack initiation and crack growth in materials subjected to stress under corrosive conditions. This includes understanding the influences of alloy composition, radiation condition, water chemistry and metallurgical starting condition (i.e., previous cold work or heat treatments and the resulting microstructure) has on the behavior of materials. Testing involves crack initiation and growth testing on irradiated specimens of single-variable alloys in simulated Light Water Reactor (LWR) environments, tensile testing, hardness testing, microstructural and microchemical analysis, and detailed efforts to characterize localized deformation. Combined, these single-variable experiments will provide mechanistic understanding that can be used to identify key operational variables to mitigate or control IASCC, optimize inspection and maintenance schedules to the most susceptible materials/locations, and, in the long-term, design IASCC-resistant materials. In support of this research, efforts are currently underway to arrange shipment of “free” high fluence austenitic alloys available through Électricité de France (EDF) for post irradiation testing at the Oak Ridge National Laboratory (ORNL) and IASCC testing at the University of Michigan. These high fluence materials range in damage values from 45 to 125 displacements per atom (dpa). The samples identified for transport to the United States, which include nine, no-cost, 304, 308 and 316 tensile bars, were relocated from the Research Institute of Atomic Reactors (RIAR) in Dimitrovgrad, Ulyanovsk Oblast, Russia, and received at the Halden Reactor in Halden, Norway, on August 23, 2016. ORNL has been notified that a significant amount of work is required to prepare the samples for further shipment to Oak Ridge, Tennessee. The preliminary work for sample shipment between Halden and Oak Ridge includes fabrication of an inner cask sample container, decontamination and preparation of a Type A container, preparation of new activity calculations, all necessary paperwork, and handling. ORNL will continue to work to track progress of sample preparation and shipment status, and to work toward an agreement that covers material shipping costs between the Halden Reactor and the Oak Ridge National Laboratory.

36 MATERIALS SCIENCE↗

Analysis of Tank 38H (HTF-38-19-77, -78) and Tank 43H (HTF-43-19-79, -80) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Overall, the results indicate the concentrations of most species in the Tank 38H surface and sub-surface samples increased significantly from the previous sample results. The Tank 38H sub-surface sample is more concentrated than the surface sample indicating stratification within the tank. Both the Tank 43H surface and sub-surface samples are similar in composition to the previous samples for most species analyzed. The Tank 43H subsurface sample remains slightly more concentrated than the surface sample indicating a small amount of stratification remains in the tank. The total uranium concentrations for the two Tank 38H samples differ significantly due to the presence of sludge solids in the sub-surface sample that markedly increased the uranium concentration. Both the Tank 38H surface and sub-surface samples have higher uranium concentrations than the previous samples from the tank. The weight percent water insoluble solids on the Tank 38H sub-surface sample show the sample contained 0.30 wt% insoluble solids, well below the 1 wt% limit. The total uranium concentrations of the two Tank 43H samples differ by <10% and are similar to the previous sample results. The sum of the major cations versus the sum of the major anions shows a difference of ~1% for the both the Tank 38H and Tank 43H surface samples providing an indication of good data quality for the nonradioactive analytes in the surface samples. The silicon concentrations measured in the Tank 38H surface and sub-surface samples are higher than the previous sample results. Due to the presence of sludge solids, the Tank 38H sub-surface sample show a silicon concentration an order of magnitude higher than the previous result. The Tank 43H surface and sub-surface samples have similar silicon concentrations and are similar to the previous Tank 43H samples. The silicon concentration was below detectable levels in the process blank. The five samples analyzed show silicon concentrations ranging from 88 to 710 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical emission from cooling flows in distant x ray clusters of galaxies

Although the Einstein satellite detected cooling flows in the x ray emission from clusters of galaxies 10 years ago, the understanding of these flows remains incomplete. The x ray emitting gas in the centers of these clusters is so dense that its cooling time is shorter than a Hubble time. Thus gas may cool and flow into the center of the cluster. This cooling gas is thermally unstable and should quickly become inhomogeneous. Optical filamentation (1-100 kpc scales) often appears near the centers of nearby clusters containing cooling flows, usually within the central galaxies accreting the gas. Indeed, only clusters with well-developed cooling flows seem to possess highly luminous, emission-line nebulae. Researchers present here some results of preliminary observational and theoretical studies of this class of emission-line objects. Researchers observed a complete, x ray selected sample of 25 distant clusters of galaxies extracted from the Einstein Extended Medium Sensitivity Survey. They discovered luminous extended H alpha emission in 10 of these clusters. Thus at least 40 percent of the clusters in the sample contain cool gas. If we crudely compare the sample to that of Arnaud (1988), in which approx. 40 percent of his 104 x ray clusters have cooling flows, the result implies that cooling flows may actually be a more common phenomenon in the past than in the present. The connection between the cooling flow and the H alpha emission is a mystery. The straightforward calculation of 1 (photoionization) to 3 (shocks) recombinations per H atom in the cooling flow gives mass infall rates 3 to 100 times greater than M derived from x ray observations. Researchers have made some preliminary theoretical calculations in an attempt to resolve this problem.

Donahue, Megan↗

Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

Dolgin, B.↗

Li NMR study of heavy-fermion LiV2O4 containing magnetic defects

We present a systematic study of the variations of the {sup 7}Li NMR properties versus magnetic defect concentration up to 0.83 mol% within the spinel structure of polycrystalline powder samples and a collection of small single crystals of LiV2O4 in the temperature range from 0.5 to 4.2 K. We also report static magnetization measurements and ac magnetic susceptibility measurements at 14 MHz on the samples at low temperatures. Both the NMR spectrum and nuclear spin-lattice relaxation rate are inhomogeneous in the presence of the magnetic defects. The NMR data for the powders are well explained by assuming that (i) there is a random distribution of magnetic point defects, (ii) the same heavy Fermi liquid is present in the samples containing the magnetic defects as in magnetically pure LiV2O4, and (iii) the influences of the magnetic defects and of the Fermi liquid on the magnetization and NMR properties are separable. In the single crystals, somewhat different behaviors are observed. Remarkably, the magnetic defects in the powder samples show evidence of spin freezing below T {approx} 1.0 K, whereas in the single crystals with similar magnetic defect concentration no spin freezing was found down to 0.5 K. Thus different types of magnetic defects and/or interactions between them appear to arise in the powders versus the crystals, possibly due to the substantially different synthesis conditions of the powders and crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

The Use of Immersion Rigs for High Temperature Hydrogen Exposure Testing Within the Nuclear Thermal Rocket Element Environmental Simulator (NTREES): NTREES-5 Hydrogen Heat Exchanger (N5HHX-01)

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility at NASA’s Marshall Space Flight Center (MSFC) subjects materials and components typically found on nuclear thermal propulsion (NTP) systems to non-nuclear simulations of prototypic NTP reactor thermohydraulic environments. With 1.2 MW of inductive power available, the currently employed methods to simulate nuclear heating in NTREES consist of 1) inductively heating a test specimen, which typically cannot be performed on ceramic materials, or 2) heating gas that envelops the test specimen. The latter of these has provided a basis for developing so-called “immersion rigs” to be used in NTREES. Furthermore, immersion rigs are especially useful in the case of smaller, technically challenging test specimens. One such device, the “NTREES-5 Hydrogen Heat Exchanger” (N5HHX-01), designed and deployed to test small material coupons to ~0.5 g/s of 2800 K, 500 psi Hydrogen, is discussed herein. To achieve this desired delivery temperature level, the most suitable material for the N5HHX’s construction was pure tungsten, which imposed budgetary and manufacturing challenges. Also discussed in this paper is the design of the N5HHX rig’s sample container, which became the first iteration of improving NTREES small material coupon test operations by permitting rapid changeout of different material samples.

Reactor Testing↗

Mechanical properties and permeability of hydrogen isotopes through CrNi35WTiAl alloy, containing radiogenic helium

The long-term contact of structural materials (SM) with tritium-containing media makes their properties in terms of kinetic permeability of hydrogen isotopes change. This change is the consequence of the defect formation in SM due to the result of {sup 3}He build-up generated by the radioactive decay of tritium dissolved in SM. This paper presents the experimental results concerning the permeability of hydrogen isotopes through CrNi35WTiAl alloy containing {sup 3}He and the impact of the presence of {sup 3}He and H on its mechanical properties. Tensile tests of cylindrical samples containing various concentrations of {sup 3}He (90, 230 and 560 appm) have been performed in inert and hydrogen atmospheres. The build-up of {sup 3}He has been made using the 'helium trick' technique. The maximal decrease in the plastic characteristics of the CrNi35WTiAl alloy occurs in samples with the highest {sup 3}He (560 appm) content at 873 K. The permeability of deuterium through the CrNi35WTiAl alloy in the initial state and that with 560 appm of {sup 3}He content was explored. The presence of this {sup 3}He concentration has shown an increase in deuterium permeability, evidently due to structural changes in the material under the impact of radiogenic helium.

36 MATERIALS SCIENCE↗

Tuning Electrical Properties through Control of TiSe 2 Thickness in (BiSe) 1+δ (TiSe 2 ) n Compounds

A series of (BiSe) 1+δ (TiSe 2 )n compounds where n was varied from two to four were synthesized and electrically characterized to explore the extent of charge transfer from the BiSe layer to the TiSe 2 layers. These kinetically stable heterostructures were prepared using the modulated elemental reactants (MER) method, in which thin amorphous elemental layers are deposited in an order that mimics the nanostructure of the desired product. X-ray diffraction (XRD), X-ray area diffraction, and scanning transmission electron microscopy (STEM) data show that the precursors formed the desired products. Specular diffraction scans contain only 00l reflections, indicating that the compounds are crystallographically aligned with the c-axis perpendicular to the substrate. The c-axis lattice parameter increases by 0.604(3) nm with each additional TiSe 2 layer. In-plane diffraction scans contain reflections that can be indexed as the (hk0) of the BiSe and TiSe 2 constituents. Area diffraction scans are also consistent with the samples containing only BiSe and TiSe 2 constituents. Rietveld refinement of the 00l XRD data was used to determine the positions of atomic planes along the c-axis. STEM data supports the structures suggested by the diffraction data and associated refinements but also shows that antiphase boundaries occur approximately 1/3 of the time in the BiSe layers. All samples showed metallic behavior for the temperature-dependent electrical resistivity between 20 K and room temperature. Electrical measurements indicated that charge is transferred from the BiSe layer to the TiSe 2 layer. The measured Hall coefficients were all negative indicating that electrons are the majority carrier and are systematically decreased as n was increased. Assuming a single parabolic band model, carrier concentration decreased when the number of TiSe 2 layers is increased, suggesting that the amount of charge donated by the BiSe layer to the TiSe 2 layers is constant. Seebeck coefficients were negative for all of the (BiSe) 1+δ (TiSe 2 ) n compounds studied, indicating that electrons are the majority carrier, and decreased as n increased. Lastly, the effective mass of the carriers was calculated to be 5–6 m e for the series of compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon nanocrystals in SiN{sub x}/SiO{sub 2} hetero-superlattices: The loss of size control after thermal annealing

Superlattices containing 3 nm thick silicon rich silicon nitride sublayers and 3 nm and 10 nm thick SiO{sub 2} barriers were prepared by plasma enhanced chemical vapor deposition. Despite the as-prepared samples represented a well-kept multilayer structure with smooth interfaces, the high temperature annealing resulted in the total destruction of multilayer structure in the samples containing 3 nm SiO{sub 2} barriers. Energy-filtered transmission electron microscopy images of these samples indicated a silicon nanoclusters formation with sizes of 2.5–12.5 nm, which were randomly distributed within the structure. Although in the sample with 10 nm SiO{sub 2} barriers some fragments of the multilayer structure could be still observed after thermal annealing, nevertheless, the formation of large nanocrystals with diameters up to 10 nm was confirmed by dark field transmission electron microscopy. Thus, in contrast to the previously published results, the expected size control of silicon nanocrystals was lost. According to the FTIR results, the thermal annealing of SiN{sub x}/SiO{sub 2} superlattices led to the formation of silicon nanocrystals in mostly oxynitride matrix. Annealed samples demonstrated a photoluminescence peak at 885 nm related to the luminescence of silicon nanocrystals, as confirmed by time-resolved photoluminescence measurements. The loss of nanocrystals size control is discussed in terms of the migration of oxygen atoms from the SiO{sub 2} barriers into the silicon rich silicon nitride sublayers. A thermodynamic mechanism responsible for this process is proposed. According to this mechanism, the driving force for the oxygen migration is the gain in the configuration entropy related to the relative arrangements of oxygen and nitrogen atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Insight into the mechanism of Sb promoted Cu(In,Ga)Se{sub 2} formation

Sb-doping has been demonstrated to be a new approach to promote Cu(In,Ga)Se{sub 2} (CIGS) thin film formation. To study the mechanism of Sb-promoted CIGS formation, we investigated the influence of Sb on the evolution of the critical intermediate Cu–Se phases, and found that Cu{sub 3}SbSe{sub 3} species was formed. Phase change of the as-prepared Cu–Se compounds at elevated temperature was determined using the differential scanning calorimetry analysis. For samples containing Sb, the melting decomposition occurred at 507.1 °C, along with aggregation of nanocrystals into a bulk, while the morphology of the sample without Sb barely changed after heating. This result suggests that the mobile Cu{sub 3}SbSe{sub 3} is likely the key intermediate responsible for Sb-promoted CIGS formation. Furthermore, we extended the scope of Sb-doping approach to solvothermal synthesis and CIGS nanocrystals were synthesized with significantly promoted kinetics in the presence of Sb. Based on these results, we propose the mechanism of Sb promoted CIGS formation. - Graphical abstract: Cu{sub 3}SbSe{sub 3} mobile phase is likely the key species to promote the formation of Cu(In,Ga)Se{sub 2}, and significantly promoting effect by Sb is also found in the synthesis of Cu(In,Ga)Se{sub 2} nanocrystals. Highlights: • In the presence of Sb, Cu{sub 3}SbSe{sub 3} is formed while synthesizing the essential intermediate Cu–Se compounds for Cu(In,Ga)Se{sub 2} materials. • Cu{sub 3}SbSe{sub 3} shows high mobility at elevated temperature. • Cu{sub 3}SbSe{sub 3} mobile phase is likely the key species to improve Cu(In,Ga)Se{sub 2} thin film formation. • A synthesis methodology is developed to produce Cu(In,Ga)Se{sub 2} nanocrystals with significantly promoted reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photometric classification and redshift estimation of LSST Supernovae

Supernova (SN) classification and redshift estimation using photometric data only have become very important for the Large Synoptic Survey Telescope (LSST), given the large number of SNe that LSST will observe and the impossibility of spectroscopically following up all the SNe. We investigate the performance of an SN classifier that uses SN colours to classify LSST SNe with the Random Forest classification algorithm. Our classifier results in an area-under-the-curve of 0.98 which represents excellent classification. We are able to obtain a photometric SN sample containing 99 percent SNe Ia by choosing a probability threshold. We estimate the photometric redshifts (photo-z) of SNe in our sample by fitting the SN light curves using the SALT2 model with nested sampling. We obtain a mean bias ($\langle$z phot - z spec $\rangle$) of 0.012 with σ($\frac{zphot-zspec}{1+zspec}$)=0.0294 σ(zphot-zspec1+zspec)=0.0294 without using a host-galaxy photo-z prior, and a mean bias ($\langle$z phot - z spec $\rangle$) of 0.0017 with σ($\frac{zphot-zspec}{1+zspec}$)=0.0116 using a host-galaxy photo-z prior. Assuming a flat ΛCDM model with Ω m = 0.3, we obtain Ω m of 0.305 ± 0.008 (statistical errors only), using the simulated LSST sample of photometric SNe Ia (with intrinsic scatter σ int = 0.11) derived using our methodology without using host-galaxy photo-z prior. Our method will help boost the power of SNe from the LSST as cosmological probes.

79 ASTRONOMY AND ASTROPHYSICS↗

Luminescence properties of lanthanide and ytterbium lanthanide titanate thin films grown by atomic layer deposition

Lanthanide based luminescent materials are highly suitable as down conversion materials in combination with a UV-absorbing host material. The authors have used TiO{sub 2} as the UV-absorbing host material and investigated the energy transfer between TiO{sub 2} and 11 different lanthanide ions, Ln{sup 3+} (Ln = La, Pr, Nd, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb) in thin films grown by atomic layer deposition. They have also investigated the possibility to improve the overall energy transfer from TiO{sub 2} to Yb{sup 3+} with a second Ln{sup 3+}, in order to enhance down conversion. The films were grown at a substrate temperature of 300 °C, using the Ln(thd){sub 3}/O{sub 3} (thd = 2,2,6,6-tetramethyl-3,5-heptanedione) and TiCl{sub 4}/H{sub 2}O precursor pairs. The focus of the work is to explore the energy transfer from TiO{sub 2} to Ln{sup 3+} ions, and the energy transfer between Ln{sup 3+} and Yb{sup 3+} ions, which could lead to efficient down conversion. The samples have been characterized by x-ray diffraction, x-ray fluorescence, spectroscopic ellipsometry, and photoluminescence. All films were amorphous as deposited, and the samples have been annealed at 600, 800, and 1000 °C in order to investigate the correlation between the crystallinity and luminescence. The lanthanum titanium oxide samples showed a weak and broad emission centered at 540 nm, which was absent in all the other samples, indicating energy transfer from TiO{sub 2} to Ln{sup 3+} in all other lanthanide samples. In the amorphous phase, all samples, apart from La, Tb, and Tm, showed a typical f-f emission when excited by a 325 nm HeCd laser. None of the samples showed any luminescence after annealing at 1000 °C due to the formation of Ln{sub 2}Ti{sub 2}O{sub 7}. Samples containing Nd, Sm, and Eu show a change in emission spectrum when annealed at 800 °C compared to the as-deposited samples, indicating that the smaller lanthanides crystallize in a different manner than the larger lanthanides. Energy transfer from Ln{sup 3+} to Yb{sup 3+} was observed neither in the amorphous or annealed samples. On the other hand, Yb{sup 3+} was found to be an efficient sensitizer for Ho{sup 3+}'s 1200 nm emission.

36 MATERIALS SCIENCE↗

Characterization Of Sample HTF-13-13-128

Savannah River Remediation (SRR) has requested that Savannah River National Laboratory (SRNL) characterize a sample of Tank 13 in preparation for Sludge Batch 9 (SB9). A 200 mL sample of Tank 13 was received by SRNL on July 22, 2013 (Tank Farm sample ID HTF-13-13-128). Characterization of the sample to meet the requirements of the request is complete. Results include: visual observations; slurry and supernatant density; weight percent total and insoluble solids; supernatant characterization; total alpha, total beta, and several radionuclide analyses; and elemental analyses of the dried solids. The sample was very fluid. After settling overnight, there was a small layer of solids on the bottom of the sample container (a 250 mL HDPE bottle) with the remainder being clear supernatant. To better show the sludge solids relative to the overall sample, 25 mL of slurry was placed in a graduated cylinder and allowed to settle over a weekend (approximately 90 hours). The sludge layer was at the approximately 4 mL. The small visually observed quantity of insoluble solids was confirmed with a low weight percent insoluble solids of 0.94%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smart Particle Collector with Real Time Spectroscopic Analysis

Facilities manufacturing materials for nuclear weapons programs release particulate matter to the environment. Particle collections from suspected facilities can help assess proliferation programs. SRNL designs and manufactures unique particle collectors for a variety of applications. The goal of this project is to develop new technologies to develop and manufacture smart particle collectors. Significant engineering advances to the collector were made using the Racetrack, an experimental breadboard setup based on the ACE 1.0 collector. Preliminary experimental results suggest significant improvement in the particle collection efficiency. The new prototype collector, “ESP-EV1”, relies on a two-stage collection region, with higher wire corona currents and voltages. Preliminary results also suggest that it is possible to extract nanoparticulates from a sample containing material from 100 nm to 10 micron-sized particulates. This project also developed new tools for spectroscopic validation of a sample and unique smart features for the collection system.

42 ENGINEERING↗

Disk–Jet Connection in Active Supermassive Black Holes in the Standard Accretion Disk Regime

We study the disk–jet connection in supermassive black holes by investigating the properties of their optical and radio emissions utilizing the SDSS DR7 and the NVSS catalogs. Our sample contains 7017 radio-loud quasars with detection both at 1.4 GHz and SDSS optical spectra. Using this radio-loud quasar sample, we investigate the correlation among the jet power (${P}_{\mathrm{jet}}$), the bolometric disk luminosity (${L}_{\mathrm{disk}}$), and the black hole mass (${M}_{\mathrm{BH}}$) in the standard accretion disk regime. We find that the jet powers correlate with the bolometric disk luminosities as $\mathrm{log}{P}_{\mathrm{jet}}=(0.96\pm 0.012)\mathrm{log}{L}_{\mathrm{disk}}+(0.79\pm 0.55)$. This suggests the jet production efficiency of ${\eta }_{\mathrm{jet}}\simeq {1.1}_{-0.76}^{+2.6}\,\times {10}^{-2}$ assuming the disk radiative efficiency of 0.1, implying low black hole spin parameters and/or low magnetic flux for radio-loud quasars. But it can be also due to the dependence of this efficiency on the geometrical thickness of the accretion flow, which is expected to be small for quasars accreting at the disk Eddington ratios $0.01\lesssim \lambda \lesssim 0.3$. This low jet production efficiency does not significantly increase even if we set the disk radiative efficiency to be 0.3. We also investigate the fundamental plane in our samples among ${P}_{\mathrm{jet}}$, ${L}_{\mathrm{disk}}$, and ${M}_{\mathrm{BH}}$. In conclusion, we could not find a statistically significant fundamental plane for radio-loud quasars in the standard accretion regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

Kelbaugh, B. N.↗