Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTER ANIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Research study of space plasma boundary processes

Representation of the Earth's bow shock and magnetopause and their geometrically determined macrostructure was investigated. Computer graphic depictions of the global distributions of bow shock structures and elementary animation of the dynamics of those distributions in the changing solar wind were developed. The shock-foreshock boundary and subcritical bow shocks as observed by ISEE 1 and 2 are discussed.

Greenstadt, E. W.↗

The Vertebrate Breed Ontology: Toward Effective Breed Data Standardization

Abstract Background Limited universally-adopted data standards in veterinary medicine hinder data interoperability and therefore integration and comparison; this ultimately impedes the application of existing information-based tools to support advancement in diagnostics, treatments, and precision medicine. Hypothesis/Objectives A single, coherent, logic-based standard for documenting breed names in health, production, and research-related records will improve data use capabilities in veterinary and comparative medicine. Animals No live animals were used. Methods The Vertebrate Breed Ontology (VBO) was created from breed names and related information compiled from the Food and Agriculture Organization of the United Nations, breed registries, communities, and experts, using manual and computational approaches. Each breed is represented by a VBO term that includes breed information and provenance as metadata. VBO terms are classified using description logic to allow computational applications and Artificial Intelligence–readiness. Results VBO is an open, community-driven ontology representing over 19 500 livestock and companion animal breed concepts covering 49 species. Breeds are classified based on community and expert conventions (e.g., cattle breed) and supported by relations to the breed's genus and species indicated by National Center for Biotechnology Information (NCBI) Taxonomy terms. Relationships between VBO terms (e.g., relating breeds to their foundation stock) provide additional context to support advanced data analytics. VBO term metadata includes synonyms, breed identifiers/codes, and attributed cross-references to other databases. Conclusion and Clinical Importance The adoption of VBO as a standard for breed names in databases and veterinary electronic health records enhances veterinary data interoperability and computability, supporting precision medicine.

Veterinary Sciences↗

Studies of Vestibular Neurons in Normal, Hyper- and Hypogravity

During the past year, pre-, in- and postflight studies were conducted in association with the Axon project for Bion 10 (Cosmos 2229). Recordings were made during pre- and postflight studies, from 118 horizontal semicircular canal afferents and 27 vestibular nucleus neurons in 7 rhesus monkeys; 137 pulse rotation protocols alone were executed (548 acceleration and deceleration responses were curve fit). Usable data was obtained from 127 horizontal afferents concerning their spontaneous discharge. Curve fits and analysis was made of sinusoidal and sum of sinusoidal responses from 42 and 35 horizontal afferents, respectively. Also recordings were made from neurons inflight from the two flight animals. The mean spontaneous rate varied from 128 spikes/sec. during preflight to 92 spikes/sec during postflight (day 5) - a change of 28%. In direct contrast to the results of Cosmos 2044, the best fitted neural adaptation operator (k) and the gain of the pulse response were decreased during post flight when compared to preflight. Surprisingly, the best fitted gain and k values for the sum of sines were slightly elevated during post flight tests. The gain and phase of single sine responses were compared for pre- and post flight tests and compared to a larger population of afferents. In contrast to Cosmos 2044 results where on the first day of post flight testing the gains of the best fitted sine response were skewed toward the higher values of the Miles and Braitman distribution, the gain of the best fitted sine responses during the first day of post flight testing (day 2) during Cosmos 2229 were exactly on the mode of the Miles and Braitman distribution. Thus, at least for the periodic stimuli, (pulses and sine waves) we found no change in gain and neural adaptation during post flight testing following Cosmos 2229. This conclusion is different from the one derived following the Cosmos 2044 flight. Cosmos flight 2229 differed from Cosmos flight 2044 in several significant ways: For example, during preflight, (1) The animals preflight training was different (less well trained on the gaze task) and (2) the animals were exposed to more experimental manipulations (surgical and rotational). Inflight, (1) the animals were required to make a pointing gesture (motor response) in association with eye movements to obtain reward, (2) the inflight diet was different (more balanced), (3) the feeder for one of the animals clogged following 9 days of flight resulting in evident dehydration and probably less head motion exposure in that monkey and (4) there was limited video taping of the monkeys in space. During postflight, (1) we were unable to test the flight animals until 26 hours postflight as compared to 14.5 hours during Cosmos 2044, (2) the animals received significantly more exposure to motion stimuli during postflight testing than during Cosmos 2044. These differences in the vestibular environment will require analysis of several parameters other than just neural and eye movement responses. For example, computer programs will have to be written and used to recover and quantify the number of head movements made by each animal during flight. This activity is critical to the production of neural adaptation and increased gain.

Correia, Manning J.↗

Using synchrotron X-ray phase-contrast micro-computed tomography to study tissue damage by laser irradiation: STUDY TISSUE DAMAGE BY LASER IRRADIATION

Background and Objective: The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. Study Design/Materials and Methods: A surgical CO2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phasecontrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. Results: We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumeswere performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. Conclusion: We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues.

Ablation↗

WE-G-303-00: Nanotechnology for Imaging and Therapy

Over the last decade, there has been a growing interest in applying nanotechnology to cancer detection, treatment, and treatment monitoring. Advances in nanotechnology have enabled the fabrication of nanoparticles from various materials with different shapes and sizes. Nanoparticles can be accumulated preferentially within tumors by either “passive targeting” through a phenomenon typically known as “enhanced permeability and retention” or “active targeting” in which nanoparticles are conjugated with antibodies or peptides directed against tumor and/or stromal markers. The tumor specificity of nanoparticles in conjunction with their unique physicochemical properties offers many novel strategies for cancer treatment and detection. For example, notable approaches in the radiation oncology setting include the use of gold nanoparticles for radiation response modulation of tumor or normal tissue and thermal ablation or hyperthermia treatment of tumors. Some of these approaches are currently being tested either on humans or on animals and, very likely, will become the clinical reality in the near future. Various computational and experimental techniques have also been applied to address unique research issues associated with nanoparticles and may become the standard tools for future investigations and clinical translations. Therefore, both clinicians and researchers may need to be properly educated about the basic principles as well as the promise of nanoparticle-based applications with regard to the future of cancer diagnostics and therapeutics. This symposium will familiarize the audience with the potential applications of nanoparticles in oncologic imaging and therapy using specific illustrative examples. The audience will be properly oriented by these illustrative examples to the multiple avenues for collaborative research amongst interdisciplinary teams of physicists, clinicians, engineers, chemists, and biologists in industry and academia. Learning Objectives: Understand the physical bases of gold nanoparticle applications for radiosensitization and x-ray fluorescence imaging Understand the parameters that define gold nanoparticle-mediated radiosensitization in biological systems Understand the potential of magnetic nanoparticle characterization of the microenvironment Understand the various strategies for radiolabeling of nanoparticles and their applications S.C. and S.K. acknowledge support from MD Anderson Cancer Center, NIH (R01CA155446 and P30CA16672) and DoD (W81XWH-12-1-0198); J.W. acknowledges support from NIH (U54CA151662-01); W.C. acknowledges support from the University of Wisconsin-Madison, NIH (R01CA169365, P30CA014520, and T32CA009206), DoD (W81XWH-11-1-0644 and W81XWH-11-1-0648), and ACS (125246-RSG-13-099-01-CCE)

60 APPLIED LIFE SCIENCES↗

WE-G-303-04: Intrinsically Radiolabeled Nanoparticles: An Emerging Paradigm

Over the last decade, there has been a growing interest in applying nanotechnology to cancer detection, treatment, and treatment monitoring. Advances in nanotechnology have enabled the fabrication of nanoparticles from various materials with different shapes and sizes. Nanoparticles can be accumulated preferentially within tumors by either “passive targeting” through a phenomenon typically known as “enhanced permeability and retention” or “active targeting” in which nanoparticles are conjugated with antibodies or peptides directed against tumor and/or stromal markers. The tumor specificity of nanoparticles in conjunction with their unique physicochemical properties offers many novel strategies for cancer treatment and detection. For example, notable approaches in the radiation oncology setting include the use of gold nanoparticles for radiation response modulation of tumor or normal tissue and thermal ablation or hyperthermia treatment of tumors. Some of these approaches are currently being tested either on humans or on animals and, very likely, will become the clinical reality in the near future. Various computational and experimental techniques have also been applied to address unique research issues associated with nanoparticles and may become the standard tools for future investigations and clinical translations. Therefore, both clinicians and researchers may need to be properly educated about the basic principles as well as the promise of nanoparticle-based applications with regard to the future of cancer diagnostics and therapeutics. This symposium will familiarize the audience with the potential applications of nanoparticles in oncologic imaging and therapy using specific illustrative examples. The audience will be properly oriented by these illustrative examples to the multiple avenues for collaborative research amongst interdisciplinary teams of physicists, clinicians, engineers, chemists, and biologists in industry and academia. Learning Objectives: Understand the physical bases of gold nanoparticle applications for radiosensitization and x-ray fluorescence imaging Understand the parameters that define gold nanoparticle-mediated radiosensitization in biological systems Understand the potential of magnetic nanoparticle characterization of the microenvironment Understand the various strategies for radiolabeling of nanoparticles and their applications S.C. and S.K. acknowledge support from MD Anderson Cancer Center, NIH (R01CA155446 and P30CA16672) and DoD (W81XWH-12-1-0198); J.W. acknowledges support from NIH (U54CA151662-01); W.C. acknowledges support from the University of Wisconsin-Madison, NIH (R01CA169365, P30CA014520, and T32CA009206), DoD (W81XWH-11-1-0644 and W81XWH-11-1-0648), and ACS (125246-RSG-13-099-01-CCE)

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-04: Biological Geometries for the Monte Carlo Simulation Toolkit TOPASNBio

Purpose: New advances in radiation therapy are most likely to come from the complex interface of physics, chemistry and biology. Computational simulations offer a powerful tool for quantitatively investigating radiation interactions with biological tissue and can thus help bridge the gap between physics and biology. The aim of TOPAS-nBio is to provide a comprehensive tool to generate advanced radiobiology simulations. Methods: TOPAS wraps and extends the Geant4 Monte Carlo (MC) simulation toolkit. TOPAS-nBio is an extension to TOPAS which utilizes the physics processes in Geant4-DNA to model biological damage from very low energy secondary electrons. Specialized cell, organelle and molecular geometries were designed for the toolkit. Results: TOPAS-nBio gives the user the capability of simulating biological geometries, ranging from the micron-scale (e.g. cells and organelles) to complex nano-scale geometries (e.g. DNA and proteins). The user interacts with TOPAS-nBio through easy-to-use input parameter files. For example, in a simple cell simulation the user can specify the cell type and size as well as the type, number and size of included organelles. For more detailed nuclear simulations, the user can specify chromosome territories containing chromatin fiber loops, the later comprised of nucleosomes on a double helix. The chromatin fibers can be arranged in simple rigid geometries or within factual globules, mimicking realistic chromosome territories. TOPAS-nBio also provides users with the capability of reading protein data bank 3D structural files to simulate radiation damage to proteins or nucleic acids e.g. histones or RNA. TOPAS-nBio has been validated by comparing results to other track structure simulation software and published experimental measurements. Conclusion: TOPAS-nBio provides users with a comprehensive MC simulation tool for radiobiological simulations, giving users without advanced programming skills the ability to design and run complex simulations.

60 APPLIED LIFE SCIENCES↗

Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brominated Luciferins Are Versatile Bioluminescent Probes

Here, we report a set of brominated luciferins for bioluminescence imaging. These regioisomeric scaffolds were accessed by using a common synthetic route. All analogues produced light with firefly luciferase, although varying levels of emission were observed. Differences in photon output were analyzed by computation and photophysical measurements. The brightest brominated luciferin was further evaluated in cell and animal models. At low doses, the analogue outperformed the native substrate in cells. The remaining luciferins, although weak emitters with firefly luciferase, were inherently capable of light production and thus potential substrates for orthogonal mutant enzymes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural characterization and computational analysis of PDZ domains in Monosiga brevicollis

Abstract Identification of the molecular networks that facilitated the evolution of multicellular animals from their unicellular ancestors is a fundamental problem in evolutionary cellular biology. Choanoflagellates are recognized as the closest extant nonmetazoan ancestors to animals. These unicellular eukaryotes can adopt a multicellular‐like “rosette” state. Therefore, they are compelling models for the study of early multicellularity. Comparative studies revealed that a number of putative human orthologs are present in choanoflagellate genomes, suggesting that a subset of these genes were necessary for the emergence of multicellularity. However, previous work is largely based on sequence alignments alone, which does not confirm structural nor functional similarity. Here, we focus on the PDZ domain, a peptide‐binding domain which plays critical roles in myriad cellular signaling networks and which underwent a gene family expansion in metazoan lineages. Using a customized sequence similarity search algorithm, we identified 178 PDZ domains in the Monosiga brevicollis proteome. This includes 11 previously unidentified sequences, which we analyzed using Rosetta and homology modeling. To assess conservation of protein structure, we solved high‐resolution crystal structures of representative M. brevicollis PDZ domains that are homologous to human Dlg1 PDZ2, Dlg1 PDZ3, GIPC, and SHANK1 PDZ domains. To assess functional conservation, we calculated binding affinities for mbGIPC, mbSHANK1, mbSNX27, and mbDLG‐3 PDZ domains from M. brevicollis . Overall, we find that peptide selectivity is generally conserved between these two disparate organisms, with one possible exception, mbDLG‐3. Overall, our results provide novel insight into signaling pathways in a choanoflagellate model of primitive multicellularity.

Gao, Melody↗

Effect of geometric and motion tracking error for awake small animal SPECT

A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

60 APPLIED LIFE SCIENCES↗

Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors

Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. Methods: The GATE Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy-3′-({sup 18}F)fluorothymidine (FLT), and were denoted FLT{sub 1} and FLT{sub 2}. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations. Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT{sub 1}) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT{sub 2}) for K{sub 1}, k{sub 2}, k{sub 3}, k{sub 4}, V{sub a}, and K{sub i}, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of K{sub i} and k{sub 3}, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although there was a slight favor for 3DRP which produced less biased k{sub 3} and K{sub i} estimates while OSEM resulted in a less biased V{sub a}. The uncertainty in OSEM parameters was about 26% (FLT{sub 1}) and 12% (FLT{sub 2}) larger than for 3DRP although identical postfilters were applied. Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.

60 APPLIED LIFE SCIENCES↗

SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be.

60 APPLIED LIFE SCIENCES↗

WE-G-303-01: Physical Bases for Gold Nanoparticle Applications in Radiation Oncology and X-Ray Imaging

Over the last decade, there has been a growing interest in applying nanotechnology to cancer detection, treatment, and treatment monitoring. Advances in nanotechnology have enabled the fabrication of nanoparticles from various materials with different shapes and sizes. Nanoparticles can be accumulated preferentially within tumors by either “passive targeting” through a phenomenon typically known as “enhanced permeability and retention” or “active targeting” in which nanoparticles are conjugated with antibodies or peptides directed against tumor and/or stromal markers. The tumor specificity of nanoparticles in conjunction with their unique physicochemical properties offers many novel strategies for cancer treatment and detection. For example, notable approaches in the radiation oncology setting include the use of gold nanoparticles for radiation response modulation of tumor or normal tissue and thermal ablation or hyperthermia treatment of tumors. Some of these approaches are currently being tested either on humans or on animals and, very likely, will become the clinical reality in the near future. Various computational and experimental techniques have also been applied to address unique research issues associated with nanoparticles and may become the standard tools for future investigations and clinical translations. Therefore, both clinicians and researchers may need to be properly educated about the basic principles as well as the promise of nanoparticle-based applications with regard to the future of cancer diagnostics and therapeutics. This symposium will familiarize the audience with the potential applications of nanoparticles in oncologic imaging and therapy using specific illustrative examples. The audience will be properly oriented by these illustrative examples to the multiple avenues for collaborative research amongst interdisciplinary teams of physicists, clinicians, engineers, chemists, and biologists in industry and academia. Learning Objectives: Understand the physical bases of gold nanoparticle applications for radiosensitization and x-ray fluorescence imaging Understand the parameters that define gold nanoparticle-mediated radiosensitization in biological systems Understand the potential of magnetic nanoparticle characterization of the microenvironment Understand the various strategies for radiolabeling of nanoparticles and their applications S.C. and S.K. acknowledge support from MD Anderson Cancer Center, NIH (R01CA155446 and P30CA16672) and DoD (W81XWH-12-1-0198); J.W. acknowledges support from NIH (U54CA151662-01); W.C. acknowledges support from the University of Wisconsin-Madison, NIH (R01CA169365, P30CA014520, and T32CA009206), DoD (W81XWH-11-1-0644 and W81XWH-11-1-0648), and ACS (125246-RSG-13-099-01-CCE)

60 APPLIED LIFE SCIENCES↗

WE-G-303-02: Gold Nanoparticles as Radiosensitizers - What Does It Take To Go From the Bench to the Bedside?

Over the last decade, there has been a growing interest in applying nanotechnology to cancer detection, treatment, and treatment monitoring. Advances in nanotechnology have enabled the fabrication of nanoparticles from various materials with different shapes and sizes. Nanoparticles can be accumulated preferentially within tumors by either “passive targeting” through a phenomenon typically known as “enhanced permeability and retention” or “active targeting” in which nanoparticles are conjugated with antibodies or peptides directed against tumor and/or stromal markers. The tumor specificity of nanoparticles in conjunction with their unique physicochemical properties offers many novel strategies for cancer treatment and detection. For example, notable approaches in the radiation oncology setting include the use of gold nanoparticles for radiation response modulation of tumor or normal tissue and thermal ablation or hyperthermia treatment of tumors. Some of these approaches are currently being tested either on humans or on animals and, very likely, will become the clinical reality in the near future. Various computational and experimental techniques have also been applied to address unique research issues associated with nanoparticles and may become the standard tools for future investigations and clinical translations. Therefore, both clinicians and researchers may need to be properly educated about the basic principles as well as the promise of nanoparticle-based applications with regard to the future of cancer diagnostics and therapeutics. This symposium will familiarize the audience with the potential applications of nanoparticles in oncologic imaging and therapy using specific illustrative examples. The audience will be properly oriented by these illustrative examples to the multiple avenues for collaborative research amongst interdisciplinary teams of physicists, clinicians, engineers, chemists, and biologists in industry and academia. Learning Objectives: Understand the physical bases of gold nanoparticle applications for radiosensitization and x-ray fluorescence imaging Understand the parameters that define gold nanoparticle-mediated radiosensitization in biological systems Understand the potential of magnetic nanoparticle characterization of the microenvironment Understand the various strategies for radiolabeling of nanoparticles and their applications S.C. and S.K. acknowledge support from MD Anderson Cancer Center, NIH (R01CA155446 and P30CA16672) and DoD (W81XWH-12-1-0198); J.W. acknowledges support from NIH (U54CA151662-01); W.C. acknowledges support from the University of Wisconsin-Madison, NIH (R01CA169365, P30CA014520, and T32CA009206), DoD (W81XWH-11-1-0644 and W81XWH-11-1-0648), and ACS (125246-RSG-13-099-01-CCE)

60 APPLIED LIFE SCIENCES↗

WE-G-303-03: Advances in in Vivo Magnetic NanoparticleSensing

Over the last decade, there has been a growing interest in applying nanotechnology to cancer detection, treatment, and treatment monitoring. Advances in nanotechnology have enabled the fabrication of nanoparticles from various materials with different shapes and sizes. Nanoparticles can be accumulated preferentially within tumors by either “passive targeting” through a phenomenon typically known as “enhanced permeability and retention” or “active targeting” in which nanoparticles are conjugated with antibodies or peptides directed against tumor and/or stromal markers. The tumor specificity of nanoparticles in conjunction with their unique physicochemical properties offers many novel strategies for cancer treatment and detection. For example, notable approaches in the radiation oncology setting include the use of gold nanoparticles for radiation response modulation of tumor or normal tissue and thermal ablation or hyperthermia treatment of tumors. Some of these approaches are currently being tested either on humans or on animals and, very likely, will become the clinical reality in the near future. Various computational and experimental techniques have also been applied to address unique research issues associated with nanoparticles and may become the standard tools for future investigations and clinical translations. Therefore, both clinicians and researchers may need to be properly educated about the basic principles as well as the promise of nanoparticle-based applications with regard to the future of cancer diagnostics and therapeutics. This symposium will familiarize the audience with the potential applications of nanoparticles in oncologic imaging and therapy using specific illustrative examples. The audience will be properly oriented by these illustrative examples to the multiple avenues for collaborative research amongst interdisciplinary teams of physicists, clinicians, engineers, chemists, and biologists in industry and academia. Learning Objectives: Understand the physical bases of gold nanoparticle applications for radiosensitization and x-ray fluorescence imaging Understand the parameters that define gold nanoparticle-mediated radiosensitization in biological systems Understand the potential of magnetic nanoparticle characterization of the microenvironment Understand the various strategies for radiolabeling of nanoparticles and their applications S.C. and S.K. acknowledge support from MD Anderson Cancer Center, NIH (R01CA155446 and P30CA16672) and DoD (W81XWH-12-1-0198); J.W. acknowledges support from NIH (U54CA151662-01); W.C. acknowledges support from the University of Wisconsin-Madison, NIH (R01CA169365, P30CA014520, and T32CA009206), DoD (W81XWH-11-1-0644 and W81XWH-11-1-0648), and ACS (125246-RSG-13-099-01-CCE)

60 APPLIED LIFE SCIENCES↗

Finch: Toxicity Dose Response Curve Prediction of Chemical Compounds and Mixtures

A paradigm shift in chemical risk assessment is emphasizing mixture testing over single compound analysis, eliminating animal testing, and adopting advanced modeling approaches to understand mixture activity profiles. However, existing computational models largely focus on single chemicals, with few effective solutions for modeling complex mixtures that account for synergistic or antagonistic effects and multiple Modes of Action (MoA). Conventional methods like concentration addition (CA) and independent action (IA) are insufficient for this task as they are designed for simplistic interactions and struggle to account for the dynamic and multifaceted nature of chemical mixtures, such as overlapping MoA and non-linear interactions. Finch offers a novel approach utilizing deep learning (DL) embeddings and multi-task quantitative structure-activity relationship (QSAR) models to improve chemical exposure prediction. By leveraging molecular descriptors, physiochemical properties, and large language model (LLM) embeddings from SMILES inputs, Finch preserves critical information in a latent space thereby enhancing predictive accuracy. The multi-task learning aspect of Finch is highly advantageous, as it simultaneously optimizes multiple loss functions, leveraging all available data across tasks to develop generalized representations that effectively capture complex ingredient interactions within mixtures.

59 BASIC BIOLOGICAL SCIENCES↗

Computer aided analysis and optimization of mechanical system dynamics

The purpose is to outline a computational approach to spatial dynamics of mechanical systems that substantially enlarges the scope of consideration to include flexible bodies, feedback control, hydraulics, and related interdisciplinary effects. Design sensitivity analysis and optimization is the ultimate goal. The approach to computer generation and solution of the system dynamic equations and graphical methods for creating animations as output is outlined.

Haug, E. J.↗