Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Energy Efficiency and Air Quality Repairs at Lyonsdale Biomass

This project enabled Lyonsdale Biomass, LLC to effect analyses, repairs and upgrades for its biomass cogeneration facility located in Lewis County, New York and close by the Adirondack Park to reduce air emissions by improving combustion technique and through the overall reduction of biomass throughput by increasing the system's thermodynamic efficiency for its steam-electrical generating cycle. Project outcomes result in significant local, New York State, Northeast U.S. and national benefits including improved renewable energy operational surety, enhanced renewable energy efficiency and more freedom from foreign fossil fuel source dependence. Specifically, the reliability of the Lyonsdale Biomass 20MWe woody biomass combined-heat and power (CHP) was and is now directly enhanced. The New York State and Lewis County benefits are equally substantial since the facility sustains 26 full-time equivalency (FTE) jobs at the facility and as many as 125 FTE jobs in the biomass logistics supply chain. Additionally, the project sustains essential local and state payment in lieu of taxes revenues. This project helps meet several USDOE milestones and contributes directly to the following sustainability goals: Climate: Reduces greenhouse gas emissions associated with bio-power production, conversion and use, in comparison to fossil fuels. Efficiency and Productivity: Enhances efficient use of renewable resources and maximizes conversion efficiency and productivity. Profitability: Lowers production costs. Rural Development: Enhances economic welfare and rural development through job creation and income generation. Standards: Develop standards and corresponding metrics for ensuring sustainable biopower production. Energy Diversification and Security: Reduces dependence on foreign oil and increases energy supply diversity. Net Energy Balance: Ensures positive net energy balance for all alternatives to fossil fuels.

30 DIRECT ENERGY CONVERSION↗

Integration& Operation of a Microgrid at Santa Rita Jail

Santa Rita Jail is a 4,500 inmate facility located in Dublin CA, approximately 40 miles (65 km) east of San Francisco. Over the past decade, a series of Distributed Energy Resources (DER) installations and efficiency measures have been undertaken to transform the 3MW facility into a"Green Jail". These include a 1.2MW rated rooftop PV system installed in 2002, a 1MW molten carbonate fuel cell with CHP, and retrofits to lighting and HVAC systems to reduce peak loads. With the upcoming installation of a large-scale battery and fast static disconnect switch, Santa Rita Jail will become a true microgrid, with full CERTS Microgrid functionality. Consequently, the jail will be able to seamlessly disconnect from the grid and operate as an island in the event of a disturbance, reconnecting again once the disturbance has dissipated. The extent to which that jail is capable of islanding is principally dependant on the energy capacity of the battery-one focus of this investigation. Also presented here are overviews of the DER currently installed at the jail, as well as the value it provides by offsetting the purchase of electricity under the current Pacific Gas& Electric (PG&E) tariff.

14 SOLAR ENERGY↗

Transamerica Pyramid Building

This is a combined heat and power (CHP) project profile on a 1 MW CCHP system at the Transamerica Pyramid Building in San Francisco, California.

Combined Heat and Power↗

SP Newsprint

This is a combined heat and power (CHP) project profile on a 45 MW steam turbine at SP Newsprint in Dublin, Georgia.

AMO↗

Fort Bragg

This is a combined heat and power (CHP) project profile on a 5 MW combustion turbine at Fort Bragg in North Carolina.

AMO↗

UNC Chapel Hill

This is a combined heat and power (CHP) project profile on a 32 MW cogeneration plant at UNC Chapel Hill in North Carolina.

AMO↗

Microgrid optimized resource dispatch for public-purpose resiliency and sustainability. The Olney Town Center Microgrid Project

Communities in Atlantic coastal regions have in recent years sought to improve the resiliency of their critical infrastructure and public services, especially to protect against hurricanes and other events capable of causing widespread damage and disruption. As the backbone of any community’s critical functions, the electricity distribution system requires high resiliency in order to maintain local energy delivery services. Against this backdrop, the Project sought to develop a resilient energy microgrid control system capable of integrating distributed renewable energy resources, natural gas CHP units, energy storage, and demand-side management technologies in near-real-time optimization schemes for the community of Olney, Md. The Montgomery County Planning Board in 2005 established the Olney Town Center area as a “civic center/town commons,” in part because it serves as a key point of interaction in the community – but also because it contains numerous vital community assets. With a total peak electrical load of about 8 MW (including Montgomery General Hospital with a 2.4 MW peak), the Project area is a business and essential services area, directly serving a suburban population of more than 33,000 residents. It contains a hospital, police station, two fire stations, two schools, grocery stores, and gas stations, and the community’s water tower, among other things. Moreover, the location stands at the crossroads of two state highways that represent major regional arteries for commerce and public safety in Montgomery County. These characteristics made the Project area an appropriate setting for considering microgrid deployment. It presented a model of a typical Maryland suburban community, with geographic dispersion of vital assets over a sizeable area, and a combination of overhead distribution lines and underground cables serving those critical loads. Such a representative model helped to ensure the solutions developed and the scenarios tested would be readily applicable to other communities in the state and the region. Further, the Project’s outcomes and lessons provide insights to guide community microgrid design and development in many locations. To achieve Project objectives – including those established by the U.S. Department of Energy (DOE) National Energy Technology Laboratory – the Project team researched, developed, and tested in simulation a set of microgrid controls capable of maintaining electricity supplies for critical community loads in the event of a regional utility outage lasting many days or even weeks. Testing and analysis showed that the microgrid would be capable of maintaining electricity supply to critical loads essentially indefinitely in most outage scenarios, while also substantially improving overall reliability for microgrid customers. With targeted improvements in local utility distribution infrastructure, test analysis showed that the microgrid would be capable of reducing annual electricity outages for critical loads by 98%. Further, to help achieve environmental and efficiency policy goals established by both the State of Maryland and the federal government, the team designed the system to reduce the annual carbon footprint of served loads by 20%, and to improve system energy efficiency for those loads by at least 20%. Testing showed that, as designed, the system is capable of meeting these performance requirements, with potential for further improvements through more effective thermal energy utilization. This Final Report, comprised of four volumes and 11 annexes, presents the results of these project efforts, including feasibility assessment (section F) and guidance for decision-makers considering prospective deployment of public-purpose microgrid systems in Maryland communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of provably secure quantum key distribution (QKD)

Optimized Quantum Key Distribution (QKD) protocols revolutionize the cyber security by leveraging the quantum phenomenon for development of unbreakable security. Configurable quantum networks are necessary for accessible quantum applications amongst multiple users. Quantum key distribution is particularly interesting because of the many ways in which the key exchange can be carried out. Keys can be exchanged by encoding the key into a weak photon source using classical methods, or the keys can be exchanged using pairs of photons entangled at the source, or the keys can even be exchanged by encoding with classical hardware at the source with an entangling measurement which occurs at the photons destination. Each type of quantum key exchange has its own requirements that must be met for point-to-point implementations which makes it exceedingly difficult to implement multi-node quantum networks. We propose a programmable network model to time encoded quantum key distribution; this version of QKD sends entangled photons to two users and the hardware is setup such that the relative time shift in the coincident photons encodes which measurement basis was used. The protocols were first simulated by modifying previous software which used the CHP quantum simulator, and then a point-to-point key exchange was setup in hardware to demonstrate the time encoding aspects of the protocol.

Dasari, Venkat↗

Thermodynamics of a Dual Stage Sodium Thermo-Electro-Chemical Converter

The need for reliable and distributable energy is evident, but one prominent obstacle is the lack of an efficient direct heat-to-electricity converter. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. This electrochemical technology uses an ion-selective solid-electrolyte called beta-alumina that is highly conductive to sodium cations. The Na-TECC generates electric power by allowing high pressure sodium cations to expand isothermally through the solid-electrolyte. Theoretically, a device interacting with thermal reservoirs at 1150 K and 550 K should operate above 45% efficiency, but actual devices have not surpassed efficiencies of 20%. The maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode (referred to as the overpotential) and by Joule heating losses due to the solid-electrolyte resistance, electrode resistance, and current collector resistance. To overcome this discrepancy, a dual stage conversion process is being proposed. Rather than using one isothermal expansion step, the dual cycle will employ two separate electrolytes to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart for a given heat input, resulting in an increased overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 800 K). This makes the device amenable to better thermal management and allows for less heat loss. Also, the intermediate stage will mitigate the thermal shock across the very thin (< 1 mm) solid electrolyte, reduce crack propagation, limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. A dual stage concept for the Na-TECC has never been demonstrated in literature, so it is necessary to properly re-define the thermodynamic parameters such as heat loss, maximum power, and optimal current density. Certain drawbacks from a dual stage concept will also be addressed, such as the need for larger electrochemical area and the increased pressure losses. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency. The improved operation of the Na-TECC can have a transformational effect on small combined heat and power (CHP) systems at the 1-5 kW range.

14 SOLAR ENERGY↗

Dual Stage Sodium Thermo-Electro-Chemical Converter (Na-TEC)

The need for reliable and distributable energy is evident, but one prominent obstacle is the lack of an efficient direct heat-to-electricity converter. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. This device uses an ion-selective solid-electrolyte called beta”-alumina that is highly conductive to sodium cations. The Na-TECC generates electric power by allowing high pressure sodium cations to expand isothermally through the solid-electrolyte. Theoretically, a device interacting with thermal reservoirs at 1150 K and 550 K should operate above 45% efficiency, but actual devices have not surpassed efficiencies of 20%. The maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode, by pressure losses through the porous electrodes, and by Joule heating losses caused by the solid-electrolyte, electrode, and current collector resistances. To overcome these low efficiencies, a dual stage conversion process is being proposed. Rather than using one isothermal expansion step, the dual cycle will employ a second electrolyte to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart for a given heat input, resulting in an increased overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 600 K). This makes the device amenable to better thermal management and allows for less heat loss. Also, the intermediate stage will mitigate the thermal shock across the very thin (< 1 mm) solid electrolyte, reduce crack propagation, limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. A dual stage concept for the Na-TECC has never been demonstrated in literature, so it is necessary to properly re-define the thermodynamic parameters such as heat loss, maximum power, and optimal current density. Certain drawbacks from a dual stage concept will also be addressed, such as the need for larger electrochemical area and the increased pressure losses. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency. The improved operation of the Na-TECC can have a transformational effect on small combined heat and power (CHP) systems at the 1-5 kW range.

14 SOLAR ENERGY↗

Final Scientific Technical Report for "Microgrid RD&D and Testing of PIDC and PWD Systems"

Alstom Grid Inc’s (ALSTOM Grid) Research Design and Development (RD&D) project, “Microgrid RD&D and Testing for PIDC and PWD” was conducted in partnership with Philadelphia Industrial Development Corporation (PIDC) in its role as owner’s representative and manager of a vibrant commercial and industrial community, involving critical loads in one of the nation’s largest unregulated, non-military electric distribution systems. PIDC needed to develop solutions to address the planned considerable growth in Distributed Energy Resources (DER) Combined Heat Plan (CHP), Renewables, Distributed Generation (DG), Demand Response (DR) and Storage. In supporting the corporate objective, PIDC needed a new class of control systems for achieving enhanced energy resilience of their critical infrastructure operation during adverse conditions together with carbon emission reduction and optimization of the overall system operation economics through system energy efficiency during normal and emergency operating conditions. Additionally, PIDC anticipated the need to support a new class of commercial agreements with tenants, such as those for Urban Outfitters, for guaranteed one hundred percent (100%) grid resilience and electric power supply in case of utility outage conditions. The project was designed to address the challenges for the commercial & industrial (C&I) communities. But more importantly, the project included development of scalable and replicable solutions intended to target a multitude of the nation’s electric distribution communities. The project researched and developed a fully comprehensive prototype consisting of microgrid operation and control functions including islanding, synchronization and reconnection, protection, voltage, frequency, and power quality management, dispatch, and system resiliency. The project provided the foundation required to significantly enhance the overall national objectives set by the DOE for energy resilience, emission reduction and system energy efficiency improvement, including protection of critical infrastructure and public resources.

14 SOLAR ENERGY↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines - Conference Paper

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Status of Overseas Microgrid Programs:Microgrid Research Activities in the U.S.

Research on microgrids in the U.S. has taken a somewhat different path than parallel efforts in Japan and Europe, and this distinction is often noted in international research forums. In general, reliability and power quality in North America is poor compared to other developed countries. For example, in the U.S., the average annual expected outage duration is a few hours, whereas in Japan, it is only a few minutes. Power quality problems in the U.S. are both large scale, such as the August 2003 blackout, and local, such as damaging voltage sags. Meeting the increasingly demanding requirements of a modern digital economy would then seem to offer a more daunting challenge for the U.S. than elsewhere, and certainly, concern that the existing power delivery system will prove inadequate for future gourmet requirements has been a motivating driver of U.S. research. This objective tends to translate into a desire for microgrids to seamlessly island when grid power is interrupted or its quality is inadequate, and to (also seamlessly) reconnect when normal service has been restored. In a sense, the microgrid is perceived as acting as an uninterruptible power supply (UPS), and sometimes even as a competitor to existing UPS options. Nonetheless, this difference is often over-stated, and the other threads that motivate microgrid research also exist in the U.S., e.g. the desire to expand renewable generation and the need to increase the efficiency of fossil-fired generation by the useful local application of waste heat in combined heat and power (CHP) systems, Further, over time, the differences are blurring as concerns about climate change increasingly dominate objectives worldwide. This article describes the CERTS Microgrid, which is almost certainly the best known U.S. example, and also briefly mentions some other U.S. microgrid research.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

25 ENERGY STORAGE↗

Integrated Building Energy Systems Design Considering Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic, as well as environmental attraction of micro-generation systems (e.g., PV or fuel cells with or without CHP) and contribute to enhanced demand response. The interactions among PV, solar thermal, and storage systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of storage technologies on demand response and CO2 emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that can pursue two strategies as its objective function. These two strategies are minimization of its annual energy costs or of its CO2 emissions. The problem is solved for a given test year at representative customer sites, e.g., nursing homes, to obtain not only the optimal investment portfolio, but also the optimal hourly operating schedules for the selected technologies. This paper focuses on analysis of storage technologies in micro-generation optimization on a building level, with example applications in New York State and California. It shows results from a two-year research projectperformed for the U.S. Department of Energy and ongoing work. Contrary to established expectations, our results indicate that PV and electric storage adoption compete rather than supplement each other considering the tariff structure and costs of electricity supply. The work shows that high electricity tariffs during on-peak hours are a significant driver for the adoption of electric storage technologies. To satisfy the site's objective of minimizing energy costs, the batteries have to be charged by grid power during off-peak hours instead of PV during on-peak hours. In contrast, we also show a CO2 minimization strategy where the common assumption that batteries can be charged by PV can be fulfilled at extraordinarily high energy costs for the site.

25 ENERGY STORAGE↗

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗