Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Semi-analytical modeling of the NIO1 source

NIO1 is a compact and versatile negative ion source, with a total current of 130 mA accelerated to 60 keV. Negative ions are created inside the plasma, which is inductively coupled to an external rf cylindrical coil operating in the range of 2 ± 0.2 MHz. The plasma is confined in the source chamber (a 50 mm radius cylinder) by a multipole magnetic field and the ions are extracted through a 3x3 matrix of apertures. The use of cesium, to enhance the negative ion production by H{sub 0} bombardment of the surfaces, is foreseen in a second stage of the operation, so that at present time the source is operating in pure volume configuration. This paper presents a model aimed to describe the main physical phenomena occurring in the source, focusing on the rf coupling with the plasma and the evolution of plasma parameters in the source. With respect to more sophisticated models of negative ion sources here we aimed to develop a fast tool capable of qualitatively describing the response of the system to variations in the basic operating parameters. The findings of this models is finally compared with the first experimental results of NIO1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the negative ion beams relevant to ITER and JT-60SA at Japan Atomic Energy Agency

In order to realize negative ion sources and accelerators to be applicable to International Thermonuclear Experimental Reactor and JT-60 Super Advanced, a large cesium (Cs)-seeded negative ion source and a multi-aperture and multi-stage electric acceleration have been developed at Japan Atomic Energy Agency (JAEA). Long pulse production and acceleration of the negative ion beams have been independently carried out. The long pulse production of the high current beams has achieved 100 s at the beam current of 15 A by modifying the JT-60 negative ion source. The pulse duration time is increased three times longer than that before the modification. As for the acceleration, a pulse duration time has been also extended two orders of magnitudes from 0.4 s to 60 s. The developments of the negative ion source and acceleration at JAEA are well in progress towards the realization of the negative ion sources and accelerators for fusion applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Age on the Relative Biological Effectiveness of Carbon Ion Radiation for Induction of Rat Mammary Carcinoma

Purpose: The risk of developing secondary cancer after radiotherapy, especially after treatment of childhood cancers, remains a matter of concern. The high biological effects of carbon-ion radiation have enabled powerful radiotherapy, yet the approach is commonly restricted to the treatment of adults. Susceptibility of the fetus to particle radiation–induced cancer is also unclear. The present study is aimed to investigate the effect of carbon-ion irradiation in childhood on breast carcinogenesis. Methods and Materials: We irradiated female Sprague-Dawley rats of various ages (embryonic days 3, 13, and 17 and 1, 3, 7, and 15 weeks after birth) with {sup 137}Cs γ rays or a 290-MeV/u monoenergetic carbonion beam (linear energy transfer, 13 keV/μm). All animals were screened weekly for mammary carcinoma by palpation until they were 90 weeks old. Results: Irradiation of fetal and mature (15-week-old) rats with either radiation source at a dose of 0.2 or 1 Gy did not substantially increase the hazard ratio compared with the nonirradiated group. Dose responses (0.2-2.0 Gy) to γ rays were similar among the groups of rats irradiated 1, 3, and 7 weeks after birth. The effect of carbon ions increased along with the age at the time of irradiation, indicating relative biological effectiveness values of 0.2 (−0.3, 0.7), 1.3 (1.0, 1.6), and 2.8 (1.8, 3.9) (mean and 95% confidence interval) for animals that were 1, 3, and 7 weeks of age, respectively. Conclusions: Our findings imply that carbonion therapy may be associated with a risk of secondary breast cancer in humans, the extent of which may depend on the age of the patient at the time of irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The specific light output of cesium iodide crystals

Large area ion chambers for a high energy cosmic ray experiment, scintillating plastic fibers as light pipes for a cosmic ray hodoscope, and an evaluation of clad scintillating light pipes were considered.

Gregory, J. C.↗

Selective incarceration of caesium ions by Venus flytrap action of a flexible framework sulfide.

The selective capture of Cs{sup +} from solution is relevant to the remediation of nuclear waste and remains a significant challenge. Here we describe a new framework composed of [(CH{sub 3}){sub 2}NH{sub 2}]{sup +} and [Ga{sub 2}Sb{sub 2}S{sub 7}]{sup 2-} layers, which are perforated with holes. Shape selectivity couples with framework flexibility, allowing the compound to respond to the ion-exchange process. The size, shape and flexibility of the holes allow Cs{sup +} ions in an aqueous solution to selectively pass through and enter the material via an ion-exchange process. Following capture, the structure dynamically closes its holes in a manner reminiscent of a Venus flytrap, which prevents the Cs{sup +} ions from leaching out. This process has useful implications in the separation science of Cs as it relates to the clean-up of nuclear waste. The dynamic response we describe here provides important insights for designing new materials for the selective removal of difficult-to-capture ions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization and CST Batch Contact Equilibrium Testing of Aged TCCR Tank 10H Batch 1A and 2 Process Supernate Samples

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs-137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium saltcake solids) within the tank followed by at-tank ion exchange column treatment. Previous equilibrium batch contact tests conducted in the SRNL Shielded Cells laboratory and associated analyses indicated that CST cesium removal performance was lower than predicted by ZAM modeling for TCCR Tank 10H Production Supernate Batch 1A. An average cesium distribution coefficient of 1,948 mL/g which corresponds to 94.1% Cs + removal was observed for Batch 1A supernate at 38 °C in January of 2019 using laboratory pretreated IONSIV™ R9120-B a CST from Lot #209900034 (predominant TCCR CST batch) at a phase ratio of 122 mL/g. This cesium loading was approximately 32% lower than model predictions, presumably due to ion exchange competition or fouling associated with alkaline earth or transition metals present in the solutions at low levels. The current testing was designed to: 1) evaluate whether supernate compositional changes during storage would result in improved cesium removal performance with CST, and 2) assist in media selection and handling protocols for future TCCR columns by evaluating several CST manufacturer batches as well as samples of one CST batch which had been pretreated using two different methods (field and laboratory methods).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Inorganic Microsphere Composite for the Selective Removal of 137 Cesium from Acidic Nuclear Waste Solutions 2: Bench-Scale Column Experiments, Modeling, and Preliminary Process Design

A new inorganic ion exchange composite for removing radioactive cesium from acidic waste streams has been developed. The new material consists of ammonium molybdophosphate, (NH4)3P(Mo3O10)4?3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C), which are produced as a by-product from coal combustion. The selective cesium exchange capacity of this inorganic composite was evaluated in bench-scale column tests using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Total cesium loading on the columns at saturation agreed very well with equilibrium values predicted from isotherm experiments performed previously. A numerical algorithm for solving the governing partial differential equations (PDE) for cesium uptake was developed using the intraparticle mass transfer coefficient obtained from previous batch kinetic experiments. Solutions to the governing equations were generated to obtain the cesium concentration at the column effluent as a function of throughput volume using the same conditions as those used for the actual column experiments. The numerical solutions of the PDE fit the column break through data quite well for all the experimental conditions in the study. The model should therefore provide a reliable prediction of column performance at larger scales.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

Modeling Crystalline Silicotitanate Performance to Support TCCR Batch 1 and Batch 1A Operations (U)

The objective of this work is to calculate the expected ion-exchange (IX) column performances of the Tank Closure Cesium Removal (TCCR) system for Tank 10H closure. Savannah River National Laboratory (SRNL) utilized: (1) the ZAM computer program (Version 4) developed by Texas A&M University for prediction of cesium loading on the crystalline silicotitanate (CST) media, (2) the OLI Studio™ software (Version 9.6) from OLI Systems to estimate waste solution properties, and (3) the VERSE-LC code (Version 7.8) developed by Purdue University to calculate column performances. The study specifically evaluates the TCCR system performance to process Tank 10H Batch 1A supernate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diagnostics of the ITER neutral beam test facility

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H{sup -}/D{sup -} production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CdZnTe Detector Using for Characterization MR Water Cleanup System before Dismantling - 17005

The Kurchatov Institute's MR research reactor water cleanup system comprises 20 containers with ion-exchange resin. Each container is 25 cm in diameter and 130 cm high. These containers are placed under the floor with 50 cm concrete protection. Access to container is provided via technological hole with protective covers. A CdZnTe detector was chosen for spectrometric investigation due to high exposure dose level from containers. A collimated spectrometric system on the basis of a semiconductor detector CdZnTe (volume of a crystal of 20 mm{sup 3} or 60 mm{sup 3}) and a multichannel analyzer InSpector 2000 was developed. It was determined that 8 of the 20 containers were filled with the ion- exchange resin in aqueous solution. The main dose forming radionuclide was {sup 137}Cs. Specific activity was from 10{sup 7} Bq/kg to 10{sup 9} Bq/kg in different containers. Measurements were carried out in high radiation fields and the background radiation reached the detector even through the lead shield, which created difficulties in the interpretation of collected data. For verification of the results some samples of ion-exchange resin was taken from containers. The concentration of γ-ray radionuclides was estimated by the Canberra Company spectrometric complex that included a semi-conductor detector made of HP Germanium. Obtained data had good correlation with the data of the CdZnTe collimated spectrometer. Our investigation has shown that remote mechanisms must be used to remove the containers with ion-exchange resin. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal at Savannah River Site - 19604

Savannah River Remediation (SRR) has developed a supplemental at-tank ion exchange capability for the removal of cesium from liquid salt waste. Building on the development of previous ion exchange initiatives and the experience of commercial nuclear plant decontamination services, and following the disaster response associated with Fukushima, the technology has matured to deploy a modular at-tank treatment system for the selective removal of cesium from bulk salt waste. If feasible, this Tank Closure Cesium Removal (TCCR) initiative would provide a supplemental treatment capability to existing and future salt processing and improve confidence in supporting the desired acceleration of waste retrieval and tank closure efforts. In addition to accelerating waste retrieval and tank closure activities, demonstration of this capability has several other benefits. Deployment of commercially available technologies with minor modification can expand Department of Energy (DOE) utilization of commercially supplied treatment processes. This 'at-tank' treatment system could be modified to evaluate and demonstrate removal of other radioactive constituents (strontium, technetium, iodine, etc.) of bulk waste. The modular aspect of this capability can allow for additional units to be delivered and deployed at SRS, as well as, provide supplemental treatment capabilities for waste treatment at other DOE sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreatment of Crystalline Silicotitanate (CST) and development of a digestion standard to support Tank Closure Cesium Removal (TCCR)

In support of Savannah River Remediation’s (SRR) deployment of an ion exchange process to remove radioactive cesium from waste supernate, referred to as the Tank Closure Cesium Removal (TCCR) process, SRNL was tasked with validating the field protocol for pretreating the crystalline silicotitanate (CST) material to be used in the columns, preparing CST for use in in-tank batch contact testing, as well as developing a digestion standard to verify complete dissolution of the CST prior to characterization after each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field. Analysis of material pretreated following the procedure confirmed similar conversion to the Na+ form of the resin as had been obtained previously. Portions of the batch of material pretreated according to the developed protocol were also used for development of a digestion standard. Results from digestion and analysis of this standard were used to establish a set of control limits for the measured Ti, Zr, and Nb concentrations in digested CST material. An aliquot of this standard CST material will be digested and analyzed alongside each in-tank batch contact sample, and the measured concentrations of Ti, Zr, and Nb will be compared against the established control limits to confirm complete digestion has occurred.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Analysis for Ion-Exchange Column System

Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗