Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

CCD Video Observation of Microgravity Crystallization of Lysozyme and Correlation with Accelerometer Data

Lysozyme has been crystallized using the ESA Advanced Protein Crystallization Facility onboard the NASA Space Shuttle Orbiter during the IML-2 mission. CCD video monitoring was used to follow the crystallization process and evaluate the growth rate. During the mission some tetragonal crystals were observed moving over distances of up to 200 micrometers. This was correlated with microgravity disturbances caused by firings of vernier jets on the Orbiter. Growth-rate measurement of a stationary crystal (which had nucleated on the growth reactor wall) showed spurts and lulls correlated with an onboard activity; astronaut exercise. The stepped growth rates may be responsible for the residual mosaic block structure seen in crystal mosaicity and topography measurements.

Snell, E. H.↗

A Search for Planetary Transits of the Star HD 187123 by Spot Filter CCD Differential Photometry

A novel method for performing high precision, time series CCD differential photometry of bright stars using a spot filter, is demonstrated. Results for several nights of observing of the 51 Pegasi b-type planet bearing star HD 187123 are presented. Photometric precision of 0.0015 - 0.0023 magnitudes is achieved. No transits are observed at the epochs predicted from the radial velocity observation. If the planet orbiting HD 187123 at 0.0415 AU is an inflated Jupiter similar in radius to HD 209458b it would have been detected at the greater than 6(sigma), level if the orbital inclination is near 90 degrees and at the greater than 3(sigma), level if the orbital inclination is as small as 82.7 degrees.

Castellano, T.↗

Shuttle and Transfer Orbit Thermal Analysis and Testing of the Chandra X-Ray Observatory CCD Imaging Spectrometer Radiator Shades

Contents include the following: (1) Introduction: Chandra X-ray observatory. Advanced CCD imaging spectrometer. (2) LEO and transfer orbit analyses: Geometric modeling in TSS w/specularity. Low earth orbital heating calculations. (3) Thermal testing and LMAC. (4) Problem solving. (5) VDA overcoat analyses. (6) VDA overcoat testing and MSFC. (7) Post-MSFC test evaluation.

Sharp, John R.↗

Chromatic Modulator for High Resolution CCD or APS Devices

A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

Frank T Hartley↗

Stereo Imaging Velocimetry Technique Using Standard Off-the-Shelf CCD Cameras

Stereo imaging velocimetry is a fluid physics technique for measuring three-dimensional (3D) velocities at a plurality of points. This technique provides full-field 3D analysis of any optically clear fluid or gas experiment seeded with tracer particles. Unlike current 3D particle imaging velocimetry systems that rely primarily on laser-based systems, stereo imaging velocimetry uses standard off-the-shelf charge-coupled device (CCD) cameras to provide accurate and reproducible 3D velocity profiles for experiments that require 3D analysis. Using two cameras aligned orthogonally, we present a closed mathematical solution resulting in an accurate 3D approximation of the observation volume. The stereo imaging velocimetry technique is divided into four phases: 3D camera calibration, particle overlap decomposition, particle tracking, and stereo matching. Each phase is explained in detail. In addition to being utilized for space shuttle experiments, stereo imaging velocimetry has been applied to the fields of fluid physics, bioscience, and colloidal microscopy.

McDowell, Mark↗

Event-Driven X-Ray CCD Detectors for High Energy Astrophysics

A viewgraph presentation describing the Event-Driven X- Ray CCD (EDCCD) detector system for high energy astrophysics is presented. The topics include: 1) EDCCD: Description and Advantages; 2) Summary of Grant Activity Carried Out; and 3) EDCCD Test System.

Ricker, George R.↗

(abstract) Reddening Measurements using CCD uvby (Stromgren) Photometry

Reddening measurements for interstellar clouds have usually relied on one of two techniques: Star counts or spectro-photometric measurements. We present preliminary results for a technique to determine the extinction using CCD uvby (Stromgren) photometry, without the need to perform special classification of the stars. The method relies on the fact that the uvby system allows two independent measurements of the reddening through the m(sub 1)and c(sub 1) indices to select the true intrensic colors for each star. Using observations from the Burrell Schmidt on Kitt Peak, we find that the technique allows reliable reddening measurements to be made down to at least V=15&supm;.

measurements↗

Method for implementation of back-illuminated CMOS or CCD imagers

A method for implementation of back-illuminated CMOS or CCD imagers. An oxide layer buried between silicon wafer and device silicon is provided. The oxide layer forms a passivation layer in the imaging structure. A device layer and interlayer dielectric are formed, and the silicon wafer is removed to expose the oxide layer.

Pain, Bedabrata↗

Predicting Chandra CCD Degradation with the Chandra Radiation Model

Not long after launch of the Chandra X-Ray Observatory, it was discovered that the Advanced CCD Imaging Spectrometer (ACIS) detector was rapidly degrading due to radiation. Analysis by Chandra personnel showed that this degradation was due to 10w energy protons (100 - 200 keV) that scattered down the optical path onto the focal plane. In response to this unexpected problem, the Chandra Team developed a radiation-protection program that has been used to manage the radiation damage to the CCDs. This program consists of multiple approaches - scheduled sating of the ACIS detector from the radiation environment during passage through radiation belts, real-time monitoring of space weather conditions, on-board monitoring of radiation environment levels, and the creation of a radiation environment model for use in computing proton flux and fluence at energies that damage the ACIS detector. This radiation mitigation program has been very successful. The initial precipitous increase in the CCDs' charge transfer inefficiency (CTI) resulting from proton damage has been slowed dramatically, with the front-illuminated CCDS having an increase in CTI of only 2.3% per year, allowing the ASIS detector's expected lifetime to exceed requirements. This paper concentrates on one aspect of the Chandra radiation mitigation program, the creation of the Chandra Radiation Model (CRM). Because of Chandra's highly elliptical orbit, the spacecraft spends most of its time outside of the trapped radiation belts that present the severest risks to the ACIS detector. However, there is still a proton flux environment that must be accounted for in all parts of Chandra's orbit. At the time of Chandra's launch there was no engineering model of the radiation environment that could be used in the outer regions of the spacecraft's orbit, so the CRM was developed to provide the flux environment of 100 - 200 keV protons in the outer magnetosphere, magnetosheath, and solar wind regions of geospace. This presentation describes CRM, its role in Chandra operations, and its prediction of the ACIS CTI increase.

Minow, Joseph I.↗

Chromatic Modulator for a High-Resolution CCD or APS

A chromatic modulator has been proposed to enable the separate detection of the red, green, and blue (RGB) color components of the same scene by a single charge-coupled device (CCD), active-pixel sensor (APS), or similar electronic image detector. Traditionally, the RGB color-separation problem in an electronic camera has been solved by use of either (1) fixed color filters over three separate image detectors; (2) a filter wheel that repeatedly imposes a red, then a green, then a blue filter over a single image detector; or (3) different fixed color filters over adjacent pixels. The use of separate image detectors necessitates precise registration of the detectors and the use of complicated optics; filter wheels are expensive and add considerably to the bulk of the camera; and fixed pixelated color filters reduce spatial resolution and introduce color-aliasing effects. The proposed chromatic modulator would not exhibit any of these shortcomings. The proposed chromatic modulator would be an electromechanical device fabricated by micromachining. It would include a filter having a spatially periodic pattern of RGB strips at a pitch equal to that of the pixels of the image detector. The filter would be placed in front of the image detector, supported at its periphery by a spring suspension and electrostatic comb drive. The spring suspension would bias the filter toward a middle position in which each filter strip would be registered with a row of pixels of the image detector. Hard stops would limit the excursion of the spring suspension to precisely one pixel row above and one pixel row below the middle position. In operation, the electrostatic comb drive would be actuated to repeatedly snap the filter to the upper extreme, middle, and lower extreme positions. This action would repeatedly place a succession of the differently colored filter strips in front of each pixel of the image detector. To simplify the processing, it would be desirable to encode information on the color of the filter strip over each row (or at least over some representative rows) of pixels at a given instant of time in synchronism with the pixel output at that instant.

Hartley, Frank↗

Structure for implementation of back-illuminated CMOS or CCD imagers

A structure for implementation of back-illuminated CMOS or CCD imagers. An epitaxial silicon layer is connected with a passivation layer, acting as a junction anode. The epitaxial silicon layer converts light passing through the passivation layer and collected by the imaging structure to photoelectrons. A semiconductor well is also provided, located opposite the passivation layer with respect to the epitaxial silicon layer, acting as a junction cathode. Prior to detection, light does not pass through a dielectric separating interconnection metal layers.

Pain, Bedabrata↗

Data Reduction and Control Software for Meteor Observing Stations Based on CCD Video Systems

The SPanish Meteor Network (SPMN) is performing a continuous monitoring of meteor activity over Spain and neighbouring countries. The huge amount of data obtained by the 25 video observing stations that this network is currently operating made it necessary to develop new software packages to accomplish some tasks, such as data reduction and remote operation of autonomous systems based on high-sensitivity CCD video devices. The main characteristics of this software are described here.

Madiedo, J. M.↗

A New Remote Sensing Filter Radiometer Employing a Fabry-Perot Etalon and a CCD Camera for Column Measurements of Methane in the Earth Atmosphere

A portable remote sensing system for precision column measurements of methane has been developed, built and tested at NASA GSFC. The sensor covers the spectral range from 1.636 micrometers to 1.646 micrometers, employs an air-gapped Fabry-Perot filter and a CCD camera and has a potential to operate from a variety of platforms. The detector is an XS-1.7-320 camera unit from Xenics Infrared solutions which combines an uncooled InGaAs detector array working up to 1.7 micrometers. Custom software was developed in addition to the graphical user basic interface X-Control provided by the company to help save and process the data. The technique and setup can be used to measure other trace gases in the atmosphere with minimal changes of the etalon and the prefilter. In this paper we describe the calibration of the system using several different approaches.

Georgieva, E. M.↗

Performance Characterization of the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) CCD Cameras

The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument currently being developed by NASA's Marshall Space Flight Center (MSFC), the National Astronomical Observatory of Japan (NAOJ), and other partners. The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's chromosphere. The polarized spectrum imaged by the CCD cameras will capture information about the local magnetic field, allowing for measurements of magnetic strength and structure. In order to make accurate measurements of this effect, the performance characteristics of the three on- board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, read noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of 2.0+/- 0.5 e--/DN, a read noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non- linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.

solar↗

Upwelling Radiance at 976 nm Measured from Space Using a CCD Camera

The Optical Payload for Lasercomm Science (OPALS) Flight System on-board the International Space Station uses a charge coupled device (CCD) camera for receiving a beacon laser from Earth. Relative measurements of the background contributed by upwelling radiance under diverse illumination conditions and varying terrain is presented. In some cases clouds in the field-of-view allowed a comparison of terrestrial and cloud-top upwelling radiance. In this paper we will report these measurements and examine the extent of agreement with atmospheric model predictions.

Biswas, Abhijit↗