SCALE Continuous-Energy Monte Carlo Depletion with Parallel KENO in TRITON

The TRITON sequence of the SCALE code system is a powerful and robust tool for performing multigroup (MG) reactor physics analysis using either the 2-D deterministic solver NEWT or the 3-D Monte Carlo transport code KENO. However, as with all MG codes, the accuracy of the results depends on the accuracy of the MG cross sections that are generated and/or used. While SCALE resonance self-shielding modules provide rigorous resonance self-shielding, they are based on 1-D models and therefore 2-D or 3-D effects such as heterogeneity of the lattice structures may render final MG cross sections inaccurate. Another potential drawback to MG Monte Carlo depletion is the need to perform resonance self-shielding calculations at each depletion step for each fuel segment that is being depleted. The CPU time and memory required for self-shielding calculations can often eclipse the resources needed for the Monte Carlo transport. This summary presents the results of the new continuous-energy (CE) calculation mode in TRITON. With the new capability, accurate reactor physics analyses can be performed for all types of systems using the SCALE Monte Carlo code KENO as the CE transport solver. In addition, transport calculations can be performed in parallel mode on multiple processors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo Benchmark

The "Monte Carlo Benchmark" (MCB) is intended to model the computatiional performance of Monte Carlo algorithms on parallel architectures. It models the solution of a simple heuristic transport equation using a Monte Carlo technique. The MCB employs typical features of Monte Carlo algorithms such as particle creation, particle tracking, tallying particle information, and particle destruction. Particles are also traded among processors using MPI calls.

Source record↗

Adaptive, Active Learning, and Multifidelity Monte Carlo Methods in the MOOSE Stochastic Tools Module

MOOSE is an open-source computational platform for constructing multi-physics models and executing them in a massively parallel fashion. It has a stochastic tools module (STM) for forward/inverse uncertainty quantification (UQ) and surrogate modeling. This presentation details some recent developments to the STM with respect to the implementation of adaptive, active learning, and multifidelity Monte Carlo methods for forward UQ of computational models. Specifically, the adaptive Monte Carlo methods include Markov Chain Monte Carlo (MCMC)-driven algorithms like adaptive importance sampling and parallelized subset simulation for statistical QoI estimation, rare events analysis, and stochastic gradient-free optimization. The active learning methods include Gaussian Process (GP) surrogates and their training via Adam optimization, design of acquisition functions, and integration with samplers like Monte Carlo, adaptive importance, and parallelized subset simulation. These active learning methods are also designed to work in a batch mode, wherein, the required calls to the full computational model are executed in parallel whenever a user-specified batch size is met. The multifidelity methods in STM are broadly divided into two categories: hierarchical, where a defined hierarchy exists among the low-fidelity models, and peer, where all the low-fidelity models are treated equally. A GP surrogate is used to learn the differences between the low- and high-fidelity models in both multifidelity categories, and acquisition functions from the active learning classes are used to decide whether to rely on a low-fidelity model or call the expensive high-fidelity model. Alongside the software description and usage, applications are also presented to nuclear engineering computational models including a TRISO nuclear fuel particle, a reactor pressure vessel, and a heat-pipe microreactor.

97 MATHEMATICS AND COMPUTING↗

Deterministic-Monte Carlo Hybrid Methods for Eigenvalue Sensitivity Coefficient Calculations

The TSUNAMI suite within the SCALE code package includes several methods for generating sensitivity data, including multigroup (MG) and continuous-energy (CE) capabilities. For generating sensitivities with CE data, three methods are available in SCALE 6.3.0: (1) the iterated fission probability (IFP) method with the KENO Monte Carlo transport solver, (2) IFP with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance Characterization (CLUTCH) with the KENO Monte Carlo transport solver. Currently, it is difficult to generate accurate sensitivities with large reflectors when using the CLUTCH method, specifically with fissionable and hydrogenous materials. To address this issue, the work presented herein examines a methodology to calculate the adjoint flux externally with the 3D deterministic SN transport code DENOVO in SCALE; the result is then read directly into the CLUTCH-TSUNAMI sequence. This hybridization method replaces the Monte Carlo F*(r) calculation in CLUTCH while still utilizing the forward calculation. The critical benchmark HEU-MET-FAST-028-001 is used to generate sensitivities based on the inability of CLUTCH to generate accurate sensitivities. Results from the hybrid method appear to generate sensitivity values that are in excellent agreement with direct perturbations. Although further testing is needed, the method provides promising results for the development and utility of a hybrid method for use in TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Monte Carlo volumetric-ray-casting estimator for global fluence tallies on GPUs

A Monte Carlo fluence estimator has been designed to take advantage of the computational power of graphical processing units (GPUs). This new estimator, termed the volumetric-ray-casting estimator, is an extension of the expectation estimator. It can be used as a replacement of the track-length estimator for the estimation of global fluence. Calculations for this estimator are performed on the GPU while the Monte Carlo random walk is performed on the central processing unit (CPU). This method lowers the implementation cost for GPU acceleration of existing Monte Carlo particle transport codes as there is little modification of the particle history logic flow. Three test problems have been evaluated to assess the performance of the volumetric-ray-casting estimator for neutron transport on GPU hardware in comparison to the standard track-length estimator on CPU hardware. Evaluation of neutron transport through air in a criticality accident scenario showed that the volumetric-ray-casting estimator achieved 23 times the performance of the track-length estimator using a single core CPU paired with a GPU and 15 times the performance of the track-length estimator using an eight core CPU paired with a GPU. Finally, simulation of a pressurized water reactor fuel assembly showed that the performance improvement was 6 times within the fuel and 7 times within the control rods using an eight core CPU paired with a single GPU.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum Monte Carlo determination of the principal Hugoniot of deuterium

Here, we present coupled electron-ion Monte Carlo results for the principal Hugoniot of deuterium together with an accurate study of the initial reference state of shock-wave experiments. We discuss the influence of nuclear quantum effects, thermal electronic excitations, and the convergence of the potential energy surface by wave-function optimization within variational Monte Carlo and projection quantum Monte Carlo methods. Compared to a previous study, our calculations also include low pressure-temperature (P,T) conditions resulting in close agreement with experimental data, while our revised results at higher (P,T) conditions still predict a more compressible Hugoniot than experimentally observed.

36 MATERIALS SCIENCE↗

Lefschetz thimble quantum Monte Carlo for spin systems

Monte Carlo simulations are useful tools for modeling quantum systems, but in some cases they suffer from a sign problem, leading to an exponential slow down in their convergence to a value. While solving the sign problem is generically NP hard, many techniques exist for mitigating the sign problem in specific cases; in particular, the technique of deforming the Monte Carlo simulation's plane of integration onto Lefschetz thimbles (complex hypersurfaces of stationary phase) has seen significant success in the context of quantum field theories. We extend this methodology to spin systems by utilizing spin coherent state path integrals to reexpress the spin system's partition function in terms of continuous variables. Using some toy systems, we demonstrate its effectiveness at lessening the sign problem in this setting, despite the fact that the initial mapping to spin coherent states introduces its own sign problem. The standard formulation of the spin coherent path integral is known to make use of uncontrolled approximations; despite this, for large spins they are typically considered to yield accurate results, so it is somewhat surprising that our results show significant systematic errors. Furthermore, possibly of independent interest, our use of Lefschetz thimbles to overcome the intrinsic sign problem in spin coherent state path integral Monte Carlo enables a novel numerical demonstration of a breakdown in the spin coherent path integral.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variational Monte Carlo calculations of n + H 3 scattering

A paramount goal in nuclear physics is to unify ab initio treatments of bound and unbound states. The position-space quantum Monte Carlo (QMC) methods have a long history of successful bound-state calculations in light systems but have seen minimal implementation in unbound systems. Here, we introduce a numerical method to improve the efficiency and accuracy of unbound-state calculations in QMC. As an initial application, we compute scattering observables for the smallest system available to probe three-body forces, the neutron-triton system, using variational Monte Carlo (VMC) wave functions. The method involves inferring long-range amplitudes in the wave function from integrals over the short-range region where all the particles interact. This approach using integral relations is well established in the literature; here, we develop it for the QMC framework. We validate our approach with a consistency check between short-range spectroscopic overlap functions computed from direct evaluation and from the integral relations; scattering amplitudes are long-range asymptotics of those overlaps. Comparison against published benchmark calculations using the same potential demonstrates that when applied to the current VMC wave functions, the integral method produces more accurate scattering observables than direct evaluation from the same variational wave function. However, it still differs noticeably from the exact results. Using additional interactions, we then present phase shifts and mixing parameters for the n + 3 H system. In particular, we present one of the first applications of the Norfolk family of local coordinate-space chiral potentials in unbound systems of A > 2. The Norfolk results accurately describe s-wave scattering but predict p-wave cross sections too large. Compared with previous QMC scattering calculations, the integral method avoids difficulties associated with the precise computation of energy differences and with convergence outside the interaction region, which is particularly severe in the variational calculation. Application of the integral method here paves the way for its use in Green's function Monte Carlo (GFMC) calculations. In GFMC, the wave functions are more accurate, but the high-precision convergence of their tails is slow, and there are additional difficulties in reading out amplitudes. Here, the integral methods will address both of those remaining problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Floating Block Method for Quantum Monte Carlo Simulations

Quantum Monte Carlo simulations are powerful and versatile tools for the quantum many-body problem. In addition to the usual calculations of energies and eigenstate observables, quantum Monte Carlo simulations can in principle be used to build fast and accurate many-body emulators using eigenvector continuation or design time-dependent Hamiltonians for adiabatic quantum computing. Furthermore, these new applications require something that is missing from the published literature, an efficient quantum Monte Carlo scheme for computing the inner product of ground state eigenvectors corresponding to different Hamiltonians. In this work, we introduce an algorithm called the floating block method, which solves the problem by performing Euclidean time evolution with two different Hamiltonians and interleaving the corresponding time blocks. We use the floating block method and nuclear lattice simulations to build eigenvector continuation emulators for energies of 4 He, 8 Be, 12 C, and 16 O nuclei over a range of local and nonlocal interaction couplings. From the emulator data, we identify the quantum phase transition line from a Bose gas of alpha particles to a nuclear liquid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation

Purpose: To measure depth dose curves for a 67.5 ± 0.1 MeV proton beam for benchmarking and validation of Monte Carlo simulation. Methods: Depth dose curves were measured in 2 beam lines. Protons in the raw beam line traversed a Ta scattering foil, 0.1016 or 0.381 mm thick, a secondary emission monitor comprised of thin Al foils, and a thin Kapton exit window. The beam energy and peak width and the composition and density of material traversed by the beam were known with sufficient accuracy to permit benchmark quality measurements. Diodes for charged particle dosimetry from two different manufacturers were used to scan the depth dose curves with 0.003 mm depth reproducibility in a water tank placed 300 mm from the exit window. Depth in water was determined with an uncertainty of 0.15 mm, including the uncertainty in the water equivalent depth of the sensitive volume of the detector. Parallel-plate chambers were used to verify the accuracy of the shape of the Bragg peak and the peak-to-plateau ratio measured with the diodes. The uncertainty in the measured peak-to-plateau ratio was 4%. Depth dose curves were also measured with a diode for a Bragg curve and treatment beam spread out Bragg peak (SOBP) on the beam line used for eye treatment. The measurements were compared to Monte Carlo simulation done with GEANT4 using TOPAS. Results: The 80% dose at the distal side of the Bragg peak for the thinner foil was at 37.47 ± 0.11 mm (average of measurement with diodes from two different manufacturers), compared to the simulated value of 37.20 mm. The 80% dose for the thicker foil was at 35.08 ± 0.15 mm, compared to the simulated value of 34.90 mm. The measured peak-to-plateau ratio was within one standard deviation experimental uncertainty of the simulated result for the thinnest foil and two standard deviations for the thickest foil. It was necessary to include the collimation in the simulation, which had a more pronounced effect on the peak-to-plateau ratio for the thicker foil. The treatment beam, being unfocussed, had a broader Bragg peak than the raw beam. A 1.3 ± 0.1 MeV FWHM peak width in the energy distribution was used in the simulation to match the Bragg peak width. An additional 1.3–2.24 mm of water in the water column was required over the nominal values to match the measured depth penetration. Conclusions: The proton Bragg curve measured for the 0.1016 mm thick Ta foil provided the most accurate benchmark, having a low contribution of proton scatter from upstream of the water tank. The accuracy was 0.15% in measured beam energy and 0.3% in measured depth penetration at the Bragg peak. The depth of the distal edge of the Bragg peak in the simulation fell short of measurement, suggesting that the mean ionization potential of water is 2–5 eV higher than the 78 eV used in the stopping power calculation for the simulation. The eye treatment beam line depth dose curves provide validation of Monte Carlo simulation of a Bragg curve and SOBP with 4%/2 mm accuracy.

60 APPLIED LIFE SCIENCES↗

Crossing the mesoscale no-man s land via parallel kinetic Monte Carlo.

The kinetic Monte Carlo method and its variants are powerful tools for modeling materials at the mesoscale, meaning at length and time scales in between the atomic and continuum. We have completed a 3 year LDRD project with the goal of developing a parallel kinetic Monte Carlo capability and applying it to materials modeling problems of interest to Sandia. In this report we give an overview of the methods and algorithms developed, and describe our new open-source code called SPPARKS, for Stochastic Parallel PARticle Kinetic Simulator. We also highlight the development of several Monte Carlo models in SPPARKS for specific materials modeling applications, including grain growth, bubble formation, diffusion in nanoporous materials, defect formation in erbium hydrides, and surface growth and evolution.

97 MATHEMATICS AND COMPUTING↗

Performance and accuracy of criticality calculations performed using WARP – A framework for continuous energy Monte Carlo neutron transport in general 3D geometries on GPUs

In this companion paper to "Algorithmic Choices in WARP - A Framework for Continuous Energy Monte Carlo Neutron Transport in General 3D Geometries on GPUs" (doi:10.1016/j.anucene.2014.10.039), the WARP Monte Carlo neutron transport framework for graphics processing units (GPUs) is benchmarked against production-level central processing unit (CPU) Monte Carlo neutron transport codes for both performance and accuracy. We compare neutron flux spectra, multiplication factors, runtimes, speedup factors, and costs of various GPU and CPU platforms running either WARP, Serpent 2.1.24, or MCNP 6.1. WARP compares well with the results of the production-level codes, and it is shown that on the newest hardware considered, GPU platforms running WARP are between 0.8 to 7.6 times as fast as CPU platforms running production codes. Also, the GPU platforms running WARP were between 15% and 50% as expensive to purchase and between 80% to 90% as expensive to operate as equivalent CPU platforms performing at an equal simulation rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclide Depletion Capabilities in the Shift Monte Carlo Code

A new depletion capability has been developed in the Exnihilo radiation transport code suite. This capability enables massively parallel domain-decomposed coupling between the Shift continuous-energy Monte Carlo solver and the nuclide depletion solvers in ORIGEN to perform high-performance Monte Carlo depletion calculations. This paper describes this new depletion capability and discusses its various features, including a multi-level parallel decomposition, high-order transport-depletion coupling, and energy-integrated power renormalization. Several test problems are presented to validate the new capability against other Monte Carlo depletion codes, and the parallel performance of the new capability is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A quasi-static Monte Carlo algorithm for the simulation of sub-prompt critical transients

A pseudo-time-dependent Monte Carlo algorithm suitable for simulating thermal reactor transients with timescales on the order of seconds is presented. An initial experimental implementation has been written into the Monte Carlo Application ToolKit (MCATK) developed at Los Alamos National Laboratory. The algorithm is essentially a combination of the fully time-dependent Monte Carlo algorithm, including the explicit simulation of delayed neutron precursors, and a quasi-static algorithm that does not use the point-kinetics equations. The fully time-dependent calculation is performed for some number of inactive and active micro time steps. The dynamic reactor time constant and delayed neutron precursor production rates are calculated directly from the active cycles, rather than from point-kinetics parameters. These quantities are then used to advance the neutron population and delayed neutron precursors forward in time across a macro time step. As a result, the method is applied to the C5G7-TD benchmark operating in steady state and in transient mode.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The F-t-Pj-RG method: An adjacent-rolling-windows based steady-state detection technique for application to kinetic Monte Carlo simulations

A window-based steady-state detection algorithm has been developed for application to kinetic Monte Carlo simulation data. The algorithm, termed F-t-Pj-RG sequentially applies an F-test, a t-test, and a projection test on adjacent windows of the data while rolling (or shifting) and growing the windows when any of the tests fail. In aggregate, the algorithm is able to (a) automatically reject the warm-up period as not being at steady-state, as well as (b) determine an appropriate window size for converged statistics when sampling the data, which is necessary for detection of steady-state, and (c) detect steady-state within a particular tolerance. The last step, the projection test, is actually an oscillating-slope projection test, and is performed on j sequential data windows (i.e., more than two adjacent windows). It requires more than simply being within the user defined tolerance: the oscillating-slope projection test includes a condition that the slope must oscillate around zero when 2, which is an additional indication of steady-state. When all three tests are passed, the F-t-Pj test is passed, indicating that the prerequisites of steady-state detection have been met and also that conditions consistent with the definition of steady-state have been realized. This algorithm is applied to a variety of data sets that correspond to the diverse type of data trends that can be produced by kinetic Monte Carlo simulations. The algorithm is shown to be robust in its ability to handle differing functional forms, and is able to detect steady-state with low computational cost. Finally, the low computational cost of this method and its robustness towards varied data trends make it suitable for on-the-fly use in kinetic Monte Carlo simulations.

97 MATHEMATICS AND COMPUTING↗

Local Correlation Between Monte-Carlo Dose and Radiation-Induced Fibrosis in Lung Cancer Patients

Purpose: To present a new method of evaluating the correlation between radiotherapy (RT)-induced fibrosis and the local dose delivered to non-small-cell lung cancer patients. Methods and Materials: Treatment plans were generated using the CadPlan treatment planning system (pencil beam, no heterogeneity corrections), and RT delivery was based on these plans. Retrospective Monte-Carlo dose calculations were performed, and the Monte-Carlo distributions of dose to real tissue were calculated using the planning computed tomography (CT) images and the number of monitor units actually delivered. After registration of the follow-up CT images with the planning CT images, different grades of radiologic fibrosis were automatically segmented on the follow-up CT images. Subsequently, patient-specific fibrosis probabilities were studied as a function of the local dose and a function of time after RT completion. Results: A strong patient-specific variation in the fibrosis volumes was found during the follow-up period. For both lungs, the threshold dose for which the probability of fibrosis became significant coincided with the threshold dose at which significant volumes of the lung were exposed. At later stages, only fibrosis localized in the high-dose regions persisted for both lungs. Overall, the Monte-Carlo dose distributions correlated much better with the probability of RT-induced fibrosis than did the CadPlan dose distributions. Conclusion: The presented method allows for an accurate, systematic, patient-specific and post-RT time-dependent numeric study of the relationship between RT-induced fibrosis and the local dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Monte Carlo Dose Calculations for High-Dose-Rate Endorectal Brachytherapy With Shielded Intracavitary Applicator

Purpose: An integrated software platform was developed to perform a patient-specific dosimetric study on high-dose-rate {sup 192}Ir endorectal brachytherapy. Monte Carlo techniques were used to examine the perturbation effects of an eight-channel intracavitary applicator with shielding and a liquid-inflatable balloon. Such effects are ignored in conventional treatment planning systems that assume water-equivalent geometries. Methods and Materials: A total of 40 Task Group 43-based rectal patient plans were calculated using the PTRAN{sub C}T Monte Carlo photon transport code. The silicone applicator, tungsten or lead shielding, contrast solution-filled balloon, and patient anatomy were included in the simulations. The dose to water and dose to medium were scored separately. The effects of heterogeneities and uncertainties in source positioning were examined. A superposition calculation method using pregenerated Monte Carlo dose distributions about the shielded applicator in water was developed and validated for efficient treatment planning purposes. Results: On average, metal shielding decreases the mean dose to the contralateral normal tissues by 24% and reduces the target volume covered by the prescribed dose from 97% to 94%. Tissue heterogeneities contribute to dose differences of <1% relative to the prescribed dose. The differences in the dose volume indices between dose to water and dose to medium-based calculations were <1% for soft tissues, <2% for bone marrow, and >20% for cortical bone. A longitudinal shift of {+-}2.5 mm and a rotational shift of {+-}15{sup o} in applicator insertion reduced the target volume receiving the prescribed dose by {<=}4%. Conclusion: The shielded applicator improved dose conformity and normal tissue sparing; however, Task Group 43-based treatment planning might compromise target coverage by not accounting for shielding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗