Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The fast neutron fluence and the activation detector activity calculations using the effective source method and the adjoint function

This paper describes the application of effective source in forward calculations and the adjoint method to the solution of fast neutron fluence and activation detector activities in the reactor pressure vessel (RPV) and RPV cavity of a VVER-440 reactor. Its objective is the demonstration of both methods on a practical task. The effective source method applies the Boltzmann transport operator to time integrated source data in order to obtain neutron fluence and detector activities. By weighting the source data by time dependent decay of the detector activity, the result of the calculation is the detector activity. Alternatively, if the weighting is uniform with respect to time, the result is the fluence. The approach works because of the inherent linearity of radiation transport in non-multiplying time-invariant media. Integrated in this way, the source data are referred to as the effective source. The effective source in the forward calculations method thereby enables the analyst to replace numerous intensive transport calculations with a single transport calculation in which the time dependence and magnitude of the source are correctly represented. In this work, the effective source method has been expanded slightly in the following way: neutron source data were performed with few group method calculation using the active core calculation code MOBY-DICK. The follow-up neutron transport calculation was performed using the neutron transport code TORT to perform multigroup calculations. For comparison, an alternative method of calculation has been used based upon adjoint functions of the Boltzmann transport equation. Calculation of the three-dimensional (3-D) adjoint function for each required computational outcome has been obtained using the deterministic code TORT and the cross section library BGL440. Adjoint functions appropriate to the required fast neutron flux density and neutron reaction rates have been calculated for several significant points within the RPV and RPV cavity of the VVER-440 reacto rand located axially at the position of maximum power and at the position of the weld. Both of these methods (the effective source and the adjoint function) are briefly described in the present paper. The paper also describes their application to the solution of fast neutron fluence and detectors activities for the VVER-440 reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of Variance Reduction Techniques in RMC Burnup and Thermal-Hydraulic Coupled Calculation

In reactor analog simulation, the Monte Carlo method has relatively high fidelity since it can reduce calculation errors resulting from using approximation methods by describing complex geometry and neutron energy spectra. The Monte Carlo method is, in essence, a stochastic simulation of the neutron transport process, and statistical uncertainty of all the computed results must be provided. In large-scale reactor computation, this method can accurately estimate integral quantities such as the effective multiplication factor (K{sub eff}), and it can limit the uncertainty within an acceptable range via reasonably selecting simulation particles. Nevertheless, it faces great challenges in estimating local quantities like neutron flux and fission power, with uncertainty of estimators beyond acceptance. To decrease the uncertainty of local quantities by increasing simulation particles may cost much time and reduce efficiency. The main reasons are as follows. Firstly, the scale of reactors is so large that common pressurized water reactors have tens of thousands of lattice cells; secondly, uneven distribution of neutron flux and fission power causes uneven distribution of uncertainty. Smith K. puts forward the 95/95 principle to estimate whether uncertainty calculated with Monte Carlo Code satisfies the requirement. According to the principle, with a confidence level of 95%, statistical errors of power density in more than 95% of the regions should be less than 1%. To meet the requirement of the principle, the uniform fission site (UFS) method is raised currently. UFS aims at redistributing fission sources to uniformize the fission source sampling, which can make statistical variance distribution more uniform. This method, which is easy to use, will not obviously increase computation time. Many studies show that UFS has a good variance reduction effect in Monte Carlo criticality calculation, but less attention is paid to its performance in burnup calculation and thermal-hydraulic coupled calculation. Uncertainty arising from the Monte Carlo method has a large impact on burnup calculation and thermal-hydraulic coupled calculation. Variance propagates between burnup steps and between iterative steps of coupled calculation, which causes asymmetry of results of the physical symmetrical regions and instability of coupled iterative convergence errors. To further verify the effect of UFS, this study uses it in the RMC (the Reactor Monte Carlo code) burnup calculation module and the neutronics/thermohydraulics coupled calculation module, and conducts two-dimensional pressurized water reactor burnup calculation and BEAVRS benchmark thermalhydraulic coupled calculation. In this way, it verifies the improvement effect of UFS on variance propagation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data extending to average depths of 2.5 mm, 3.4 mm, and 10 mm for the 1-mm, 2-mm, and 5-mm dimension calculation matrices, respectively. These results emphasize the importance of selecting as small a treatment planning software calculation matrix dimension as is practically possible and of taking a conservative approach for skin treatment planning objectives. One suggested conservative approach is accomplished by defining the skin organ as the outermost 2-3 mm of the body such that the high dose tail of the skin organ dose-volume histogram curve represents dose on the deep side of the skin where the algorithm is more accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy

Purpose: The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer.Methods: PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal{sup Registered-Sign} (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle{sup 3} (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point.Results: The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average {+-}1{sigma} dose difference (calculated - measured) of -0.65%{+-} 1.62% without the bolus and -0.20%{+-} 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19%{+-} 3.27% without the bolus and -0.05%{+-} 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50%{+-} 3.06% without bolus and -0.18%{+-} 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%{+-} 6.21% without bolus and 1.75%{+-} 5.94% with the bolus. From a clinical perspective an agreement of 5% or better between planned (calculated) and delivered (measured) dose is desired. Statistically, this was true for 99% ({+-}2{sigma}) of the dose points for three of the four cases for the PBRA dose calculations, the exception being the nose without bolus for which this was true for 89% ({+-}1.6{sigma}) of the dose points. For the retromolar trigone, with and without bolus, the PBA showed agreement of 5% or better for approximately 86% ({+-}1.5{sigma}) of the dose points. For the nose, with and without bolus, the PBA showed agreement of 5% or better for only approximately 58% ({+-}0.8{sigma}) of the dose points.Conclusions: The measured data, whose high precision makes them useful for evaluation of the accuracy of electron dose algorithms, will be made publicly available. Based on the spread in dose differences, the PBRA has at least twice the accuracy of the PBA. From a clinical perspective the PBRA accuracy is acceptable in the retromolar trigone and nose for electron therapy with and without bolus.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine

Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, −0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for distance-to-agreement.Conclusions: The authors found HPlusQA to be reasonably effective (79%± 10%) in determining when the comparison between measured dose planes and the dose planes calculated by the Eclipse treatment planning system had exceeded the acceptable tolerance levels. When used as described in this study, HPlusQA can reduce the need for patient specific quality assurance measurements by 64%. The authors believe that the use of HPlusQA as a dose calculation second check can increase the efficiency and effectiveness of the QA process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local voxel-based deviation of −2.41% ± 0.75% for all voxels with dose values >20% were found for 11 modulated plans in the cheese phantom. Averaged over nine patient plans, the deviations amounted to −0.14% ± 1.97% (voxels >80%) and −0.95% ± 2.27% (>20%, local deviations). For a lung case, mean voxel-based deviations of more than 4% were found, while for all other patient plans, all mean voxel-based deviations were within ±2.4%. Conclusions: The presented method is suitable for independent dose calculation for helical tomotherapy within the known limitations of the pencil beam algorithm. It can serve as verification of the primary dose calculation and thereby reduce the need for time-consuming measurements. By using the patient anatomy and generating full 3D dose data, and combined with measurements of additional machine parameters, it can substantially contribute to overall patient safety.

60 APPLIED LIFE SCIENCES↗

Osmotic potential calculations of inorganic and organic aqueous solutions over wide solute concentration levels and temperatures

Purpose: To demonstrate that the authors’ new “aqueous solution vs pure water” equation to calculate osmotic potential may be used to calculate the osmotic potentials of inorganic and organic aqueous solutions over wide ranges of solute concentrations and temperatures. Currently, the osmotic potentials of solutions used for medical purposes are calculated from equations based on the thermodynamics of the gas laws which are only accurate at low temperature and solute concentration levels. Some solutions used in medicine may need their osmotic potentials calculated more accurately to take into account solute concentrations and temperatures. Methods: The authors experimented with their new equation for calculating the osmotic potentials of inorganic and organic aqueous solutions up to and beyond body temperatures by adjusting three of its factors; (a) the volume property of pure water, (b) the number of “free” water molecules per unit volume of solution, “N{sub f},” and (c) the “t” factor expressing the cooperative structural relaxation time of pure water at given temperatures. Adequate information on the volume property of pure water at different temperatures is available in the literature. However, as little information on the relative densities of inorganic and organic solutions, respectively, at varying temperatures needed to calculate N{sub f} was available, provisional equations were formulated to approximate values. Those values together with tentative t values for different temperatures chosen from values calculated by different workers were substituted into the authors’ equation to demonstrate how osmotic potentials could be estimated over temperatures up to and beyond bodily temperatures. Results: The provisional equations formulated to calculate N{sub f}, the number of free water molecules per unit volume of inorganic and organic solute solutions, respectively, over wide concentration ranges compared well with the calculations of N{sub f} using recorded relative density data at 20 °C. They were subsequently used to estimate N{sub f} values at temperatures up to and excess of body temperatures. Those values, together with t values at temperatures up to and in excess of body temperatures recorded in the literature, were substituted in the authors’ equation for the provisional calculation of osmotic potentials. The calculations indicated that solution temperatures and solute concentrations have a marked effect on osmotic potentials. Conclusions: Following work to measure the relative densities of aqueous solutions for the calculation of N{sub f} values and the determination of definitive t values up to and beyond bodily temperatures, the authors’ equation would enable the accurate estimations of the osmotic potentials of wide concentrations of aqueous solutions of inorganic and organic solutes over the temperature range. The study illustrates that not only solute concentrations but also temperatures have a marked effect on osmotic potentials, an observation of medical and biological significance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aeroelastic Calculations of Quiet High- Speed Fan Performed

An advanced high-speed fan was recently designed under a cooperative effort between the NASA Glenn Research Center and Honeywell Engines & Systems. The principal design goals were to improve performance and to reduce fan noise at takeoff. Scale models of the Quiet High-Speed Fan were tested for operability, performance, and acoustics. During testing, the fan showed significantly improved noise characteristics, but a self-excited aeroelastic vibration known as flutter was encountered in the operating range. Flutter calculations were carried out for the Quiet High-Speed Fan using a three-dimensional, unsteady aerodynamic, Reynolds-averaged Navier-Stokes turbomachinery code named "TURBO." The TURBO code can accurately model the viscous flow effects that can play an important role in various aeroelastic problems such as flutter with flow separation, flutter at high loading conditions near the stall line (stall flutter), and flutter in the presence of shock and boundary-layer interaction. Initially, calculations were performed with no blade vibrations. These calculations were at a constant rotational speed and a varying mass flow rate. The mass flow rate was varied by changing the backpressure at the exit boundary of the computational domain. These initial steady calculations were followed by aeroelastic calculations in which the blades were prescribed to vibrate harmonically in a natural mode, at a natural frequency, and with a fixed interblade phase angle between adjacent blades. The AE-prep preprocessor was used to interpolate the in-vacuum mode shapes from the structural dynamics mesh onto the computational fluid dynamics mesh and to smoothly propagate the grid deformations from the blade surface to the interior points of the grid. The aeroelastic calculations provided the unsteady aerodynamic forces on the blade surface due to blade vibrations. These forces were vector multiplied with the structural dynamic mode shape to calculate the work done on the blade during one vibration period, then this result was converted to an aerodynamic damping. Flutter occurs when the aerodynamic damping becomes negative, if structural damping is ignored. The results of these aeroelastic calculations are summarized in this plot of aerodynamic damping versus mass flow rate at a constant rotational speed. As the backpressure is increased, the mass flow rate through the fan decreases and the fan operating point moves towards the stall line. The aeroelastic calculations showed that the aerodynamic damping decreases as the stall line is approached, as observed during testing. In addition, the aeroelastic calculations with the TURBO code correctly predicted the aeroelastic parameters: the most unstable vibration mode and interblade phase angle, as observed during testing. The Quiet High-Speed Fan demonstrated significant noise reductions during testing, but flutter imposed limits on its operating range. The accurate calculation of the aeroelastic characteristics using the TURBO code is a significant step toward eliminating flutter from the operating range and toward realizing the benefits of reduced fan noise. The aeroelastic calculations described here were performed under a grant by University of Toledo researchers in collaboration with Glenn's researchers.

Bakhle, Milind A.↗

Coupled Neutron and Gamma Heating Calculation Based on VARIANT Nodal Transport Method

Accurate determination of temperature distributions in fuel pins and duct walls is essential for fuel-pin performance and assembly bowing analyses. Currently, the multi-assembly, sub-channel analysis code SE2-ANL is used in thermalhydraulic analysis of sodium cooled fast reactors (SFR). SE2- ANL is interfaced with the DIF3D/GAMSOR/DIF3D procedure for coupled neutron and gamma heating calculations, developed at Argonne National Laboratory (ANL). In this procedure, the neutron flux distribution is first calculated using the finite-difference diffusion theory option of the DIF3D code. Using the neutron flux solution, the GAMSOR code computes the gamma source distribution for the subsequent gamma flux calculation with DIF3D. However, in the current heating calculation scheme, the neutron and gamma flux calculations are limited to six triangular meshes per hexagonal assembly. In addition, the pin power distributions are estimated by assuming that the power distribution within an assembly is separable in the radial and axial directions. In each assembly, the axial power profile is obtained by averaging the power densities of six triangular meshes at each axial mesh interval. The radial power profile is evaluated at a single axial mesh (e.g., at the core mid-plane) by approximating the neutron and gamma flux distributions by a linear or quadratic polynomial of two variables x and y, depending on the polynomial order specified by the user. The coefficients of the linear and quadratic polynomials are determined by the least squares fit of six and 24 triangular mesh fluxes, respectively. Furthermore, the total heat generation rate in an assembly duct wall is simply determined by a user-specified fraction of the total gamma heating within that assembly. With the advancement of computer technology, the nodal transport theory code VARIANT is routinely used in core design analyses of SFR instead of DIF3D. It is therefore necessary to develop a new heating calculation procedure based on VARIANT neutron and gamma transport calculations. In this study, a new, coupled neutron and gamma heating calculation scheme has been developed to determine the pin power distributions more accurately by eliminating the aforementioned limitations of the current procedure. For this, the GAMSOR code has been extended to generate the intra-nodal gamma source distribution to be consistent with the trial functions of VARIANT. In the new heating calculation procedure, the neutron flux distribution is determined first by solving an eigenvalue transport problem using VARIANT. The obtained neutron flux is then used in GAMSOR to calculate the gamma source distribution. Using this gamma source distribution, the gamma flux distribution is determined by solving a fixed-source transport problem using VARIANT again. Using the computed neutron and gamma flux distributions, the power distribution in each fuel pin and duct wall is determined using a new utility code CURVE, which has been developed to evaluate the VARIANT flux solution at each fuel pin position and along the duct mid-wall. For each pin segment contained in a VARIANT node, the axial power shape is represented as a quadratic profile. The performance of the new heating calculation scheme based on VARIANT transport solutions has been tested against the existing method of SE2-ANL, using the ABR-1000 metal core design. The gamma source distribution and the assembly, fuel pin and duct wall power distributions were calculated and compared. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Environment-based pin-power reconstruction method for homogeneous core calculations

Core calculation schemes are usually based on a classical two-step approach associated with assembly and core calculations. During the first step, infinite lattice assemblies calculations relying on a fundamental mode approach are used to generate cross-sections libraries for PWRs core calculations. This fundamental mode hypothesis may be questioned when dealing with loading patterns involving several types of assemblies (UOX, MOX), burnable poisons, control rods and burn-up gradients. This paper proposes a calculation method able to take into account the heterogeneous environment of the assemblies when using homogeneous core calculations and an appropriate pin-power reconstruction. This methodology is applied to MOX assemblies, computed within an environment of UOX assemblies. The new environment-based pin-power reconstruction is then used on various clusters of 3x3 assemblies showing burn-up gradients and UOX/MOX interfaces, and compared to reference calculations performed with APOLLO-2. The results show that UOX/MOX interfaces are much better calculated with the environment-based calculation scheme when compared to the usual pin-power reconstruction method. The power peak is always better located and calculated with the environment-based pin-power reconstruction method on every cluster configuration studied. This study shows that taking into account the environment in transport calculations can significantly improve the pin-power reconstruction so far as it is consistent with the core loading pattern. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross-sections relative to water. In specific situations, differences between the current water-based BT dose calculation formalism (TG-43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy-dependent differences between dose calculated to water in a homogeneous water geometry (TG-43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel-by-voxel interaction cross sections. Neither conventional single-energy CT nor ICRU/ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient-source-applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG-186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG-43-based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG-43 calculated doses. Assignments of voxel-by-voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG-43. MBDCA commissioning will share commonalities with current TG-43-based systems, but in addition there will be algorithm-specific tasks. Two levels of commissioning are recommended: reproducing TG-43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG-186 guidance should retain practice uniformity in transitioning from the TG-43 to the MBDCA approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-19: Accuracy of Dual-Energy CT-Derived Relative Electron Density for Proton Therapy Dose Calculation

Purpose: To determine the suitability of dual-energy CT (DECT) to calculate relative electron density (RED) of tissues for accurate proton therapy dose calculation. Methods: DECT images of RED tissue surrogates were acquired at 80 and 140 kVp. Samples (RED=0.19−2.41) were imaged in a water-equivalent phantom in a variety of configurations. REDs were calculated using the DECT numbers and inputs of the high and low energy spectral weightings. DECT-derived RED was compared between geometric configurations and for variations in the spectral inputs to assess the sensitivity of RED accuracy versus expected values. Results: RED accuracy was dependent on accurate spectral input influenced by phantom thickness and radius from the phantom center. Material samples located at the center of the phantom generally showed the best agreement to reference RED values, but only when attenuation of the surrounding phantom thickness was accounted for in the calculation spectra. Calculated RED changed by up to 10% for some materials when the sample was located at an 11 cm radius from the phantom center. Calculated REDs under the best conditions still differed from reference values by up to 5% in bone and 14% in lung. Conclusion: DECT has previously been used to differentiate tissue types based on RED and Z for binary tissue-type segmentation. To improve upon the current standard of empirical conversion of CT number to RED for treatment planning dose calculation, DECT methods must be able to calculate RED to better than 3% accuracy throughout the image. The DECT method is sensitive to the accuracy of spectral inputs used for calculation, as well as to spatial position in the anatomy. Effort to address adjustments to the spectral calculation inputs based on position and phantom attenuation will be required before DECT-determined RED can achieve a consistent level of accuracy for application in dose calculation.

60 APPLIED LIFE SCIENCES↗

SU-E-J-200: A Dosimetric Analysis of 3D Versus 4D Image-Based Dose Calculation for Stereotactic Body Radiation Therapy in Lung Tumors

Purpose: To evaluate the dosimetric difference between 3D and 4Dweighted dose calculation using patient specific respiratory trace and deformable image registration for stereotactic body radiation therapy in lung tumors. Methods: Two dose calculation techniques, 3D and 4D-weighed dose calculation, were used for dosimetric comparison for 9 lung cancer patients. The magnitude of the tumor motion varied from 3 mm to 23 mm. Breath-hold exhale CT was used for 3D dose calculation with ITV generated from the motion observed from 4D-CT. For 4D-weighted calculation, dose of each binned CT image from the ten breathing amplitudes was first recomputed using the same planning parameters as those used in the 3D calculation. The dose distribution of each binned CT was mapped to the breath-hold CT using deformable image registration. The 4D-weighted dose was computed by summing the deformed doses with the temporal probabilities calculated from their corresponding respiratory traces. Dosimetric evaluation criteria includes lung V20, mean lung dose, and mean tumor dose. Results: Comparing with 3D calculation, lung V20, mean lung dose, and mean tumor dose using 4D-weighted dose calculation were changed by −0.67% ± 2.13%, −4.11% ± 6.94% (−0.36 Gy ± 0.87 Gy), −1.16% ± 1.36%(−0.73 Gy ± 0.85 Gy) accordingly. Conclusion: This work demonstrates that conventional 3D dose calculation method may overestimate the lung V20, MLD, and MTD. The absolute difference between 3D and 4D-weighted dose calculation in lung tumor may not be clinically significant. This research is supported by Siemens Medical Solutions USA, Inc and Iowa Center for Research By Undergraduates.

60 APPLIED LIFE SCIENCES↗

One-bond 13 C– 13 C spin-coupling constants in saccharides: a comparison of experimental and calculated values by density functional theory using solid-state 13 C NMR and X-ray crystallography

Methyl aldohexopyranosides were 13 C-labeled at contiguous carbons, crystallized, and studied by single-crystal X-ray crystallography and solid-state 13 C nuclear magnetic resonance (NMR) spectroscopy to examine the degree to which density functional theory (DFT) can calculate one-bond 13C–13C spin-coupling constants ( 1 J CC ) in saccharides with sufficient accuracy to permit their use in MA'AT analysis, a newly-reported hybrid DFT/NMR method that provides probability distributions of molecular torsion angles in solution (Zhang et al., J. Phys. Chem. B, 2017, 121, 3042–3058; Meredith et al., J. Chem. Inf. Model., 2022, 62, 3135–3141). Experimental 1 J CC values in crystalline samples of the doubly 13 C-labeled compounds were measured by solid-state 13 C NMR and compared to those calculated from five different DFT models: (1) 1 J CC values calculated from single structures identical to those observed in crystalline samples by X-ray crystallography (all atom refinement); (2) 1 J CC values calculated from the single structures in (1) but after Hirshfeld atom refinement (HAR); (3) 1 J CC values calculated from the single structures in (1) after DFT-optimization of hydrogen atoms only; and (4 and 5) 1 J CC values calculated in rotamers of torsion angle θ 2 (C1–C2–O2–O2H) or ω(C4–C5–C6–O6) from which either specific or generalized parameterized equations were obtained and used to calculate 1 J CC values in the specific θ 2 or ω rotamers observed in crystalline samples. Good qualitative agreement was observed between calculated 1 J CC values and those measured by solid-state 13 C NMR regardless of the DFT model, but in no cases were calculated 1 J CC values quantitative, differing (over-estimated) on average by 4–5% from experimental values. These findings, and those reported recently from solution NMR studies (Tetrault et al., J. Phys. Chem. B 2022, 126, 9506–9515), indicate that improvements in DFT calculations are needed before calculated 1 J CC values can be used directly as reliable constraints in MA'AT analyses of saccharides in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-71: Commissioning and Acceptance Testing of a Commercial Monte Carlo Electron Dose Calculation Model (eMC) for TrueBeam

Purpose: To provide commissioning and acceptance test data of the Varian Eclipse electron Monte Carlo model (eMC v.11) for TrueBeam linac. We also investigated the uncertainties in beam model parameters and dose calculation results for different geometric configurations. Methods: For beam commissioning, PTW CC13 thimble chamber and IBA Blue Phantom2 were used to collect PDD and dose profiles in air. Cone factors were measured with a parallel plate chamber (PTW N23342) in solid water. GafChromic EBT3 films were used for dose calculation verifications to compare with parallel plate chamber results in the following test geometries: oblique incident, extended distance, small cutouts, elongated cutouts, irregular surface, and heterogeneous layers. Results: Four electron energies (6e, 9e, 12e, and 15e) and five cones (6×6, 10×10, 15×15, 20×20, and 25×25) with standard cutouts were calculated for different grid sizes (1, 1.5,2, and 2.5 mm) and compared with chamber measurements. The results showed calculations performed with a coarse grid size underestimated the absolute dose. The underestimation decreased as energy increased. For 6e, the underestimation (max 3.3 %) was greater than the statistical uncertainty level (3%) and was systematically observed for all cone sizes. By using a 1mm grid size, all the calculation results agreed with measurements within 5% for all test configurations. The calculations took 21s and 46s for 6e and 15e (2.5mm grid size) respectively distributed on 4 calculation servants. Conclusion: In general, commissioning the eMC dose calculation model on TrueBeam is straightforward and thedose calculation is in good agreement with measurements for all test cases. Monte Carlo dose calculation provides more accurate results which improves treatment planning quality. However, the normal acceptable grid size (2.5mm) would cause systematic underestimation in absolute dose calculation for lower energies, such as 6e. Users need to be cautious in this situation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-78: Comparison of Dose-Averaged Linear Energy Transfer Calculation Methods Used in Monte Carlo Simulations of Clinical Proton Beams

Purpose: To evaluate the differences in dose-averaged linear energy transfer (LETd) maps calculated in water by means of different strategies found in the literature in proton therapy Monte Carlo simulations and to compare their values with dose-mean lineal energy microdosimetry calculations. Methods: The Geant4 toolkit (version 9.6.2) was used. Dose and LETd maps in water were scored for primary protons with cylindrical voxels defined around the beam axis. Three LETd calculation methods were implemented. First, the LETd values were computed by calculating the unrestricted linear energy transfer (LET) associated to each single step weighted by the energy deposition (including delta-rays) along the step. Second, the LETd was obtained for each voxel by computing the LET along all the steps simulated for each proton track within the voxel, weighted by the energy deposition of those steps. Third, the LETd was scored as the quotient between the second momentum of the LET distribution, calculated per proton track, over the first momentum. These calculations were made with various voxel thicknesses (0.2 – 2.0 mm) for a 160 MeV proton beamlet and spread-out Bragg Peaks (SOBP). The dose-mean lineal energy was calculated in a uniformly-irradiated water sphere, 0.005 mm radius. Results: The value of the LETd changed systematically with the voxel thickness due to delta-ray emission and the enlargement of the LET distribution spread, especially at shallow depths. Differences of up to a factor 1.8 were found at the depth of maximum dose, leading to similar differences at the central and distal depths of the SOBPs. The third LETd calculation method gave better agreement with microdosimetry calculations around the Bragg Peak. Conclusion: Significant differences were found between LETd map Monte Carlo calculations due to both the calculation strategy and the voxel thickness used. This could have a significant impact in radiobiologically-optimized proton therapy treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data points tested. The model was capable of predicting the depth of the maximum dose within 1 mm. Anthropomorphic phantom benchmark testing of modulated and patterned MLCs treatment plans showed agreement to measurement within 3% in target regions using thermoluminescent dosimeters (TLD). Using radiochromic film normalized to TLD, a gamma criteria of 3% of maximum dose and 2 mm DTA was applied with a pass rate of least 85% in the high dose, high gradient, and low dose regions. Finally, recalculations of patient plans using DPM showed good agreement relative to a commercial TPS when comparing dose volume histograms and 2D dose distributions. Conclusions: A unique analytical source model coupled to the dose planning method Monte Carlo dose calculation code has been modified and validated using basic beam data and anthropomorphic phantom measurement. While this tool can be applied in general use for a particular linac model, specifically it was developed to provide a singular methodology to independently assess treatment plan dose distributions from those clinical institutions participating in National Cancer Institute trials.

60 APPLIED LIFE SCIENCES↗