SEARCH · Engineering Papers
Results for “Biomedical”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Transformation of a ceramic precursor to a biomedical (metallic) alloy: Part I – sinterability of Ta 2 O 5 and TiO 2 mixed oxides
Mixed Ta 2 O 5 – TiO 2 binary system was studied by a combination of differential thermal analysis (DTA), scanning electron microscopy-energy dispersive spectrometry (SEM-EDS), X-ray diffraction (XRD) and in situ high temperature X-ray diffraction (HT-XRD) techniques. Different compositions of the mixed oxide powders were fabricated by ball–milling the powdered compositions, pelletizing the homogenized composite powders, and heating the green pellets in air at different temperatures for fixed time intervals. The sintered pellets were evaluated and characterized with respect to porosity, morphology, and phase distribution. DTA runs of the un-sintered powders indicated the onset temperatures for both exothermic and endothermic changes in the binary system. Significant amount of sintering was observed to take place at temperatures higher than 900 °C. Both room and high temperature X-ray diffraction patterns exhibited consistency in phase formation. A ternary compound (TaTiO 4 ) and a ternary solid solution (Ti 0.33 Ta 0.67 O 2 ) were observed to form in both room and high temperatures in addition to the respective binary phases (Ta 2 O 5 and TiO 2 ). A sintering temperature in the range 900–1000 °C was observed to be adequate to achieve the requisite mechanical strength and optimum internal porosity (40–48%) for subsequent electrochemical polarization experiments.
Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL
We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.
Tribocorrosion behavior of additive manufactured Ti-6Al-4V biomedical alloy
Not Available
Subdivision meshes for organizing spatial biomedical data.
Abstract As bio-medical images and volumes are being collected at an increasing speed, there is a growing demand for efficient means to organize spatial information for comparative analysis. In many scenarios, such as determining gene expression patterns by in situ hybridization, the images are collected from multiple subjects over a common anatomical region, such as the brain. A fundamental challenge in comparing spatial data from different images is how to account for the shape variations among subjects, which makes direct image-to-image comparison meaningless. In this paper, we describe subdivision meshes as a geometric means to efficiently organize 2D images and 3D volumes collected from different subjects for comparison. The key advantages of a subdivision mesh for this purpose are its light-weight geometric structure and its explicit modeling of anatomical boundaries, which enable efficient and accurate registration. The multi-resolution structure of a subdivision mesh also allows development of fast comparison algorithms among registered images and volumes.
Rapid Production of Graphite Without Contamination for Biomedical AMS
The application of AMS to the detection of 14 C makes possible a new class of sensitive experiments in molecular biology. Such experiments inherently produce large numbers of samples for the determination of biological variability in molecular interactions. The samples vary in 14 C concentration over many orders of magnitude. We added TiH 2 to aid the reduction of CO 2 by zinc in a sealed tube to reproducibly make graphite without sample cross-contamination. The CO 2 is transferred from a combustion tube to the reaction tube through a disposable plastic manifold. The sealed tubes are heated to a single-reaction temperature in a muffle furnace. The process is complete within 5 h. Bulk isotopic fractionation in the finished graphite is less than 0.5%.
Near-Infrared Fluorescent NanoGUMBOS for Biomedical Imaging
Herein, we report on near-infrared (NIR) fluorescent nanoparticles generated from an emergent class of materials we refer to as a Group of Uniform Materials Based on Organic Salts (GUMBOS). GUMBOS are largely frozen ionic liquids, although the concept is more general and is also easily applied to solid ionic materials with melting points in excess of 100 C. Nanoparticles based on GUMBOS (nanoGUMBOS) derived from a NIR fluorophore are prepared using a reprecipitation method and evaluated for in vivo fluorescence imaging. Due to their uniformity, single-step preparation, and composite nature, nanoGUMBOS help to resolve issues with dye leakage problems innate to alternate cellular stains and unlock a myriad of applications for these materials, highlighting exciting possibilities for multifunctional nanoGUMBOS.
Chiral DOTA chelators as an improved platform for biomedical imaging and therapy applications
Despite established clinical utilisation, there is an increasing need for safer, more inert gadolinium-based contrast agents, and for chelators that react rapidly with radiometals. Here we report the syntheses of a series of chiral DOTA chelators and their corresponding metal complexes and reveal properties that transcend the parent DOTA compound. We incorporated symmetrical chiral substituents around the tetraaza ring, imparting enhanced rigidity to the DOTA cavity, enabling control over the range of stereoisomers of the lanthanide complexes. The Gd chiral DOTA complexes are shown to be orders of magnitude more inert to Gd release than [GdDOTA]¯. These compounds also exhibit very-fast water exchange rates in an optimal range for high field imaging. Radiolabeling studies with (Cu-64/Lu-177) also demonstrate faster labelling properties. These chiral DOTA chelators are alternative general platforms for the development of stable, high relaxivity contrast agents, and for radiometal complexes used for imaging and/or therapy.
Three-dimensional piezoelectric polymer microsystems for vibrational energy harvesting, robotic interfaces and biomedical implants
Piezoelectric microsystems are of use in areas such as mechanical sensing, energy conversion and robotics. The systems typically have a planar structure, but transforming them into complex three-dimensional (3D) frameworks could enhance and extend their various modes of operation. Here, we report a controlled, nonlinear buckling process to convert lithographically defined two-dimensional patterns of electrodes and thin films of piezoelectric polymers into sophisticated 3D piezoelectric microsystems. To illustrate the engineering versatility of the approach, we create more than twenty different 3D geometries. With these structures, we then demonstrate applications in energy harvesting with tailored mechanical properties and root-mean-square voltages ranging from 2 mV to 790 mV, in multifunctional sensors for robotic prosthetic interfaces with improved responsivity (for example, anisotropic responses and sensitivity of 60 mV N -1 for normal force), and in bio-integrated devices with in vivo operational capabilities. We note the 3D geometries, especially those with ultralow stiffnesses or asymmetric layouts, yield unique mechanical attributes and levels of functionality that would be difficult or impossible to achieve with conventional two-dimensional designs.
High-energy proton imaging for biomedical applications
The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. As a result, tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.
Noncontact tip-enhanced Raman spectroscopy for nanomaterials and biomedical applications
Demonstration of a proof of the concept and feasibility of a non-contact TERS approach promising for imaging of materials with high aspect ratio surface patterns and biomaterials.
Photon avalanche in lanthanide doped nanoparticles for biomedical applications: super-resolution imaging
Photon avalanche in lanthanide doped nanoparticles shows exceptional properties, potentially suitable for single photoexcitation beam sub-diffraction imaging.
Towards the stable chelation of radium for biomedical applications with an 18-membered macrocyclic ligand
Targeted alpha therapy is an emerging strategy for the treatment of disseminated cancer. [ 223 Ra]RaCl 2 is the only clinically approved alpha particle-emitting drug, and it is used to treat castrate-resistant prostate cancer bone metastases, to which [ 223 Ra]Ra 2+ localizes. To specifically direct [ 223 Ra]Ra 2+ to non-osseous disease sites, chelation and conjugation to a cancer-targeting moiety is necessary. Although previous efforts to stably chelate [223Ra]Ra2+ for this purpose have had limited success, here we report a biologically stable radiocomplex with the 18-membered macrocyclic chelator macropa. Quantitative labeling of macropa with [ 223 Ra]Ra 2+ was accomplished within 5 min at room temperature with a radiolabeling efficiency of >95%, representing a significant advancement over conventional chelators such as DOTA and EDTA, which were unable to completely complex [ 223 Ra]Ra 2+ under these conditions. [ 223 Ra][Ra(macropa)] was highly stable in human serum and exhibited dramatically reduced bone and spleen uptake in mice in comparison to bone-targeted [ 223 Ra]RaCl 2 , signifying that [ 223 Ra][Ra(macropa)] remains intact in vivo. Upon conjugation of macropa to a single amino acid b-alanine as well as to the prostate-specific membrane antigen-targeting peptide DUPA, both constructs retained high affinity for 223 Ra, complexing >95% of Ra 2+ in solution. Furthermore, [ 223 Ra][Ra(macropa-b-alanine)] was rapidly cleared from mice and showed low 223 Ra bone absorption, indicating that this conjugate is stable under biological conditions. Unexpectedly, this stability was lost upon conjugation of macropa to DUPA, which suggests a role of targeting vectors in complex stability in vivo for this system. Nonetheless, our successful demonstration of efficient radiolabeling of the b-alanine conjugate with 223 Ra and its subsequent stability in vivo establishes for the first time the possibility of delivering [ 223 Ra]Ra 2+ to metastases outside of the bone using functionalized chelators, marking a significant expansion of the therapeutic utility of this radiometal in the clinic.
Radiolabeling and in vivo evaluation of lanmodulin with biomedically relevant lanthanide isotopes
This work describes successful radiochemical labeling and subsequent in vivo evaluation of radiolanthanide-tagged versions of lanmodulin (LanM), a lathanide-binding protein.
Biomedical Imaging: SPECT and PET
Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are non-invasive nuclear imaging techniques relying on the use of tomographic reconstruction methods to provide 3D representations of the distribution of radiolabeled molecules in vivo. Differences in the underlying physical principles determine the achievable spatial resolution, sensitivity, specificity and observation time span of these two imaging modalities. Their specific characteristics are described and the current technology developments and design tradeoffs are reviewed.