Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Debris Disk Explorer: A Balloon-Borne Coronagraph for Observing Debris Disks

The Debris Disk Explorer (DDX) is a proposed balloon-borne investigation of debris disks around nearby stars. Debris disks are analogs of the Asteroid Belt (mainly rocky) and Kuiper Belt (mainly icy) in our Solar System. DDX will measure the size, shape, brightness, and color of tens of disks. These measurements will enable us to place the Solar System in context. By imaging debris disks around nearby stars, DDX will reveal the presence of perturbing planets via their influence on disk structure, and explore the physics and history of debris disks by characterizing the size and composition of disk dust. The DDX instrument is a 0.75-m diameter off-axis telescope and a coronagraph carried by a stratospheric balloon. DDX will take high-resolution, multi-wavelength images of the debris disks around tens of nearby stars. Two flights are planned; an overnight test flight within the United States followed by a month-long science flight launched from New Zealand. The long flight will fully explore the set of known debris disks accessible only to DDX. It will achieve a raw contrast of 10(exp -7), with a processed contrast of 10(exp -8). A technology benefit of DDX is that operation in the near-space environment will raise the Technology Readiness Level of internal coronagraphs, deformable mirrors, and wavefront sensing and control, all potentially needed for a future space-based telescope for high-contrast exoplanet imaging.

High Altitude Balloon↗

Current Status of a NASA High-Altitude Balloon-Based Observatory for Planetary Science

Recent studies have shown that progress can be made on over 20% of the key questions called out in the current Planetary Science Decadal Survey by a high-altitude balloon-borne observatory. Therefore, NASA has been assessing concepts for a gondola-based observatory that would achieve the greatest possible science return in a low-risk and cost-effective manner. This paper addresses results from the 2014 Balloon Observation Platform for Planetary Science (BOPPS) mission, namely successes in the design and performance of the Fine Pointing System. The paper also addresses technical challenges facing the new Gondola for High Altitude Planetary Science (GHAPS) reusable platform, including thermal control for the Optical Telescope Assembly, power generation and management, and weight-saving considerations that the team will be assessing in 2015 and beyond.

predictive filter↗

Guidelines and Suggestions for Balloon Gondola Design

This paper discusses the current gondola design requirements for the Columbia Scientific Balloon Facility (CSBF). The CSBF is responsible for launching and supporting balloon borne scientific instruments and has some current updated guidelines that will be discussed in this presentation. As the sophistication of Payload systems have increased in size and complexity new guidelines have been implemented in order to make these instruments stay within the acceptable launch risks. Additionally, there is a requirement to submit a proper stress analysis report that states the flight design requirements have been met. Suggestions are discussed in this presentation that establish the proper guidelines to submit these.

Guidelines for Balloon Gondola Design↗

Galactic Cosmic Radiation (GCR) Measurements Made by M-42 Active Dosimeters on NASA Balloon Flights (New Mexico & Antarctica) Resemble Levels Expected at Mars

Mimicking galactic cosmic radiation (GCR) is difficult with ground-based simulations and experimental results are limited by facility constraints. In the past year, we flew two consecutive missions on large NASA scientific balloons (to ~ 38 km altitude) launched from New Mexico (6.5-hr flight) and Antarctica (32-d flight) and will report GCR doses comparable to levels expected at the equatorial Mars surface. Measurements were made in collaboration with the DLR and utilizing the M-42 active radiation dosimeter developed for use on Artemis 1. The M-42 instrument stores data in flash memory, records charged particles over a substantial part of the trapped proton and the GCR LET spectrum, and can be easily integrated into payloads due to its compact size (182 x 44 x 22 mm; 237 g) and internal battery (up to 6 weeks of operation). Our presentation will provide an overview of the two recent balloon missions (payload description; flight profiles), and summarize the radiation data collected in the middle stratosphere, highlighting how robust, real GCR exposures can be achieved without needing to fly orbital or deep space experiments.

radiation↗

Solar Montgolfiere Balloons for Mars

A novel hot air balloon system, known as a solar Montgolfiere, appears quite viable for controlled balloon landings at selected martian surface locations.

Mars↗

Conflict Resolution Strategies for Balloon-Airship Encounters in Upper Class E Air Traffic Management (ETM)

This paper examines strategic conflict resolution strategies for pair-wise high-altitude balloon, airship encounters. By strategic is meant that the conflict is identified (detected) at the time of flight plan submission or flight plan alteration through a service, such as an ETM Service Supplier (ESS). We investigate optimal control solutions for two classes of problems: non-cooperative, where the balloon must alter its ascent trajectory in order to avoid the airship and cooperative, where both vehicles make maneuvers through a negotiation protocol.

airship balloon negotiation optimal control↗

Conflict Resolution Strategies for Balloon-Airship Encounters in Upper Class E Air Traffic Management (ETM)

This paper examines strategic conflict resolution strategies for pair-wise high-altitude balloon, airship encounters. By strategic is meant that the conflict is identified (detected) at the time of flight plan submission or flight plan alteration through a service, such as an ETM Service Supplier (ESS). We investigate optimal control solutions for two classes of problems: non-cooperative, where the balloon must alter its ascent trajectory in order to avoid the airship and cooperative, where both vehicles make maneuvers through a negotiation protocol.

airship balloon negotiation optimal control↗

NASA Balloon Program Office

Presentation documenting the basic operations of the balloon program in 2023. - The NASA Balloon Program provides low-cost, quick response, near-space access to NASA’s science Community for conducting Cutting Edge Science Investigations - Observatory-class Payloads With Advanced Technologies and Large Aperture/Mass - Serve as a technology development platform for future space missions - Instrument & Subsystem development for NASA Flight Projects - Provide hands-on training for Educators, Students and Young Scientists

Balloons↗

Launching a Tethered Balloon in the Artic

Sandia atmospheric scientist Dari Dexheimer regularly flies tethered balloons out of Sandia’s dedicated Arctic airspace on Oliktok Point, the northernmost point of Alaska’s Prudhoe Bay. These 13-foot-tall balloons carry distributed temperature sensors to collect Arctic atmospheric temperature profiles, or the temperature of the air at different heights above the ground, among other atmospheric sensors. The data Sandia collects is critical for understanding Arctic clouds to inform global climate models.

47 OTHER INSTRUMENTATION↗

The Role of 'Cutting' Balloon Angioplasty for the Treatment of Short Femoral Bifurcation Steno-Obstructive Disease

This study was designed to report our experience with 'cutting' balloon angioplasty (CBA) for the treatment of short femoral bifurcation arterial stenosis. Between March 2005 and September 2007, 18 consecutive patients who were high-risk for surgery with critical limb ischemia or severe lifestyle-limiting claudication underwent 'cutting' balloon angioplasty (4-6 mm diameter/15-20-mm length) for the treatment of 27 focal (<3 cm) severe fibro-calcified stenosis of the common femoral artery (n = 14) and/or the proximal part of the superficial femoral artery (n = 6) or profunda femoris (n = 7). Baseline patient demographic data, pre- and post-procedural patient clinical data, and procedural results were recorded. Follow-up consisted of clinical check-up and color duplex ultrasonography (CDU) examination 1, 3, 6, 12, and 18 months after the procedure. All endovascular treatments were successfully performed with clinical success obtained for all patients. No complications occurred during all treatments and no patient required surgical conversion or placement of a stent because of recoil, dissection, or arterial tears. No acute vessel closure was registered. During a mean follow-up of 9.4 (range, 6-18) months, endovascular treatment (CBA) was performed for restenosis/occlusion of seven lesions (25.9%) in four patients, whereas surgical treatment (endarterectomy with patch) for restenosis/occlusion of three lesions (11.1%) was performed in two patients with a consequent reintervention rate of 37%. Primary and secondary patency rates were 84.6 and 88.4% at 6 months and 57.9 and 79.6% at 12 months, respectively. No major limb amputation was performed, with a 12-month limb salvage rate of 88.9%. CBA seems to be a valuable tool for the endovascular treatment of focal femoral bifurcation stenotic lesions for patients who are poor candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting-Balloon Angioplasty in Transplant Renal Artery Stenosis as First-Line Treatment in the Early Postoperative Period

Percutaneous transluminal angioplasty has been successfully used for the treatment of transplant renal artery stenosis (RAS). Cutting-balloon angioplasty (CBA) is being used as a second option in pressure-resistant stenosis. It is thought that CBA is less traumatic and therefore restenosis occurs less frequently than in conventional angioplasty. This case report describes the unusual use of a cutting balloon in transplant RAS as a first option in the early postoperative period. Long-term follow-up data are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Balloon-Occluded Retrograde Transvenous Obliteration for Gastric Varix Mainly Draining into the Pericardiophrenic Vein

Two cases of gastric varices were treated by balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein at our hospital, and both were successful. One case developed left hydrothorax. Gastric varices did not bled and esophageal varices were not aggravated in both cases for 24-30 months thereafter. These outcomes indicate the feasibility of balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Paclitaxel-Coated Balloons for the Treatment of Dysfunctional Dialysis Access. Results from a Single-Center, Retrospective Analysis

PurposeTo investigate the safety and effectiveness of lutonix paclitaxel-coated balloon (PCB) for the treatment of dysfunctional dialysis access.Materials and MethodsThis was a single-center, single-arm, retrospective analysis of 39 patients (23 male, 59 %) undergoing 61 interventions using 69 PCBs in a 20-month period. There was a balance between arteriovenous fistulae (AVF) and grafts (AVG) (20 AVFs, 19AVGs), and the majority of lesions were restenotic (25/39, 64.1 %). Mean balloon diameter used was 6.6 mm and length 73.4 mm. Primary outcome measure was target lesion primary patency (TLPP) at 6 months, while secondary outcome measures included factors affecting TLPP and major complications. As there were lesions treated more than once with PCB, authors also compared patency results after first and second PCB angioplasty.ResultsTLPP was 72.2 % at 6 months with a median patency of 260 days according to the Kaplan–Meier survival analysis. No major complications occurred. TLPP between AVFs and AVGs (311 vs. 237 days, respectively; p = 0.29) and de novo and restenotic lesions was similar (270.5 vs. 267.5 days, respectively; p = 0.50). In 14 cases, in which lesions were treated with two PCB angioplasties, a statistically significant difference in TLPP after the second treatment was noted (first intervention 179.5 days vs. second intervention 273.5 days; p = 0.032).ConclusionIn this retrospective analysis, Lutonix PCB proved to be safe and effective in treating restenosis in dysfunctional dialysis access with results comparable to the literature available. Larger studies are needed to prove abovementioned results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Balloon Plasty for Thoracic Duct Occlusion in a Patient with Chylothorax and Chylous Ascites

A patient developed abdominal distension, dyspnea, and nausea due to chylothorax and chylous ascites 1 month after bruising her back. Lymphangiography was unable to identify the site of lymph leakage, and lymphatic duct embolization was impractical. However, lymphangiography showed occlusion of the thoracic duct. Thus, balloon plasty was performed to restore the patency of the thoracic duct, and the chylothorax and chylous ascites improved. Although embolization of the thoracic or lymphatic ducts has been reported as a treatment for lymphorrhea, it is impractical if the lymphatic duct responsible for leakage cannot be identified. In such a case, balloon plasty of the occluded thoracic duct to lower the pressure in the peripheral lymphatic ducts was successfully performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Patient and Lesion Characteristics on Drug-Coated Balloon Angioplasty in the Femoropopliteal Artery: A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Objectives: The principal objective of this pooled analysis was to investigate various patient and lesion characteristics on late lumen loss (LLL) after drug-coated balloon (DCB) angioplasty. Background: Four randomized controlled trials (THUNDER, FEMPAC, PACIFIER, CONSEQUENT) were pooled to investigate the influence of various patient and lesion characteristics on DCB angioplasty and on plain old balloon angioplasty (POBA) in patients with femoropopliteal artery disease. Methods: Angiographic data from 355 patients were pooled to assess the impact of patient (demographics, cardiovascular risk factors, cardiovascular co-morbidities, Rutherford stages) and lesion-/procedure-related (location, occlusion, length, restenosis, calcification, subintimal crossing, post-dilatation, dissection, stenting) characteristics on LLL. Linear regression models were utilized with LLL as the dependent variable to determine the predictive value of cardiovascular and lesion-/procedure-related factors. Results: Observational statistics revealed that LLL was lower in the DCB group as compared to POBA independent of all tested patient variables. LLL after DCB was also independent of most lesion and procedural characteristics except for lesion length and bailout stenting. LLL increased with lesion length in both treatment groups. Bailout stenting did not improve LLL in the DCB group but did so in the POBA group (0.74 ± 1.07 mm vs. 1.22 ± 1.36 mm, p = 0.043). Conclusions: DCB was superior to POBA for all tested patient subgroups and lesion subgroups. Our results suggest that all patients and lesions benefit to a similar degree from the use of DCB. DCB-PTA should therefore be preferred to POBA in all patients with steno-occlusive femoropopliteal lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferior Vena Cava Rupture Caused by Balloon Angioplasty During the Treatment of Budd–Chiari Syndrome

Objective: Percutaneous transluminal balloon angioplasty (PTA) is the main treatment option for Budd–Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. However, IVC rupture caused by PTA has never been reported. Materials and Methods: Between August 2004 and December 2016, a consecutive cohort of 617 BCS patients with obstructed IVC who underwent PTA with or without stent placement were reviewed retrospectively to identify IVC rupture. Pre- and post-procedural imaging data, clinical and procedural technical data were analyzed. Results: Of the 617 BCS patients, five patients had IVC rupture caused by PTA (0.81%). Four of these patients had retroperitoneal, intra-hepatic IVC rupture without extravasation into abdominal cavity which was successfully managed conservatively. One patient had supra-hepatic IVC rupture into the pericardial cavity which was surgically treated. Conclusion: IVC rupture is a rare complication of PTA treatment of BCS and most commonly located at the intra-hepatic IVC caused by oversized balloons which does not require additional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Skin and Chest Wall Dose Delivered With Multicatheter, Contura Multilumen Balloon, and MammoSite Breast Brachytherapy

Purpose: Skin and chest wall doses have been correlated with toxicity in patients treated with breast brachytherapy . This investigation compared the ability to control skin and chest wall doses between patients treated with multicatheter (MC), Contura multilumen balloon (CMLB), and MammoSite (MS) brachytherapy. Methods and Materials: 43 patients treated with the MC technique, 45 patients treated with the CMLB, and 83 patients treated with the MS were reviewed. The maximum doses delivered to the skin and chest wall were calculated for all patients. Results: The mean maximum skin doses for the MC, CMLB, and MS were 2.3 Gy (67% of prescription dose), 2.8 Gy (82% of prescription dose), and 3.2 Gy per fraction (94% of prescription dose), respectively. Although the skin distances were similar (p = 0.23) for the two balloon techniques, the mean skin dose with the CMLB was significantly lower than with the MS (p = 0.05). The mean maximum rib doses for the MC, CMLB, and MS were 2.3 Gy (67% of prescription dose), 2.8 Gy (82% of prescription dose), and 3.6 Gy per fraction (105% of prescription dose), respectively. Again, the mean rib dose with the CMLB was significantly lower than with the MS (p = 0.002). Conclusion: The MC and CMLB techniques are associated with significantly lower mean skin and rib doses than is the MS. Treatment with the MS was associated with significantly more patients receiving doses to the skin or rib in excess of 125% of the prescription. Treatment with the CMLB may prove to yield less normal tissue toxicity than treatment with the MS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗