TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive

For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.

47 OTHER INSTRUMENTATION↗

Preliminary results of calculations for heavy-water nuclear-power-plant reactors employing {sup 235}U, {sup 233}U, and {sup 232}Th as a fuel and meeting requirements of a nonproliferation of nuclear weapons

A physical design is developed for a gas-cooled heavy-water nuclear reactor intended for a project of a nuclear power plant. As a fuel, the reactor would employ thorium with a small admixture of enriched uranium that contains not more than 20% of {sup 235}U. It operates in the open-cycle mode involving {sup 233}U production from thorium and its subsequent burnup. The reactor meets the conditions of a nonproliferation of nuclear weapons: the content of fissionable isotopes in uranium at all stages of the process, including the final one, is below the threshold for constructing an atomic bomb, the amount of product plutonium being extremely small.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Protecting Privacy of Shared Epidemiologic Data without Compromising Analysis Potential

Objective . Ensuring privacy of research subjects when epidemiologic data are shared with outside collaborators involves masking (modifying) the data, but overmasking can compromise utility (analysis potential). Methods of statistical disclosure control for protecting privacy may be impractical for individual researchers involved in small-scale collaborations. Methods . We investigated a simple approach based on measures of disclosure risk and analytical utility that are straightforward for epidemiologic researchers to derive. The method is illustrated using data from the Japanese Atomic-bomb Survivor population. Results . Masking by modest rounding did not adequately enhance security but rounding to remove several digits of relative accuracy effectively reduced the risk of identification without substantially reducing utility. Grouping or adding random noise led to noticeable bias. Conclusions . When sharing epidemiologic data, it is recommended that masking be performed using rounding. Specific treatment should be determined separately in individual situations after consideration of the disclosure risks and analysis needs.

Cologne, John↗

Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

54 ENVIRONMENTAL SCIENCES↗

Mechanistic Comparison between Gastric Bypass vs. Duodenal Switch with Sleeve Gastrectomy in Rat Models

Both gastric bypass (GB) and duodenal switch with sleeve gastrectomy (DS) have been widely used as bariatric surgeries, and DS appears to be superior to GB. The aim of this study was to better understand the mechanisms leading to body weight loss by comparing these two procedures in experimental models of rats. Animals were subjected to GB, DS or laparotomy (controls), and monitored by an open-circuit indirect calorimeter composed of comprehensive laboratory animal monitoring system and adiabatic bomb calorimeter. Body weight loss was greater after DS than GB. Food intake was reduced after DS but not GB. Energy expenditure was increased after either GB or DS. Fecal energy content was increased after DS but not GB. GB induced body weight loss by increasing energy expenditure, whereas DS induced greater body weight loss by reducing food intake, increasing energy expenditure and causing malabsorption in rat models.

59 BASIC BIOLOGICAL SCIENCES↗

Genomic Instability and Radiation Risk in Molecular Pathways to Colon Cancer

Colon cancer is caused by multiple genomic alterations which lead to genomic instability (GI). GI appears in molecular pathways of microsatellite instability (MSI) and chromosomal instability (CIN) with clinically observed case shares of about 15–20% and 80–85%. Radiation enhances the colon cancer risk by inducing GI, but little is known about different outcomes for MSI and CIN. Computer-based modelling can facilitate the understanding of the phenomena named above. Comprehensive biological models, which combine the two main molecular pathways to colon cancer, are fitted to incidence data of Japanese a-bomb survivors. The preferred model is selected according to statistical criteria and biological plausibility. Imprints of cell-based processes in the succession from adenoma to carcinoma are identified by the model from age dependences and secular trends of the incidence data. Model parameters show remarkable compliance with mutation rates and growth rates for adenoma, which has been reported over the last fifteen years. Model results suggest that CIN begins during fission of intestinal crypts. Chromosomal aberrations are generated at a markedly elevated rate which favors the accelerated growth of premalignant adenoma. Possibly driven by a trend of Westernization in the Japanese diet, incidence rates for the CIN pathway increased notably in subsequent birth cohorts, whereas rates pertaining to MSI remained constant. An imbalance between number of CIN and MSI cases began to emerge in the 1980s, whereas in previous decades the number of cases was almost equal. The CIN pathway exhibits a strong radio-sensitivity, probably more intensive in men. Among young birth cohorts of both sexes the excess absolute radiation risk related to CIN is larger by an order of magnitude compared to the MSI-related risk. Observance of pathway-specific risks improves the determination of the probability of causation for radiation-induced colon cancer in individual patients, if their exposure histories are known.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Effects on Mortality from Solid Cancers Other than Lung, Liver, and Bone Cancer in the Mayak Worker Cohort: 1948–2008

Radiation effects on mortality from solid cancers other than lung, liver, and bone cancer in the Mayak worker cohort: 1948–2008. The cohort of Mayak Production Association (PA) workers in Russia offers a unique opportunity to study the effects of prolonged low dose rate external gamma exposures and exposure to plutonium in a working age population. We examined radiation effects on the risk of mortality from solid cancers excluding sites of primary plutonium deposition (lung, liver, and bone surface) among 25,757 workers who were first employed in 1948–1982. During the period 1948–2008, there were 1,825 deaths from cancers other than lung, liver and bone. Using colon dose as a representative external dose, a linear dose response model described the data well. The excess relative risk per Gray for external gamma exposure was 0.16 (95% CI: 0.07 – 0.26) when unadjusted for plutonium exposure and 0.12 (95% CI 0.03 – 0.21) when adjusted for plutonium dose and monitoring status. There was no significant effect modification by sex or attained age. Plutonium exposure was not significantly associated with the group of cancers analyzed after adjusting for monitoring status. Site-specific risks were uncertainly estimated but positive for 13 of the 15 sites evaluated with a statistically significant estimate only for esophageal cancer. Comparison with estimates based on the acute exposures in atomic bomb survivors suggests that the excess relative risk per Gray for prolonged external exposure in Mayak workers may be lower than that for acute exposure but, given the uncertainties, the possibility of equal effects cannot be dismissed.

60 APPLIED LIFE SCIENCES↗

Apparent climate-mediated loss and fragmentation of core habitat of the American pika in the Northern Sierra Nevada, California, USA

Contemporary climate change has been widely documented as the apparent cause of range contraction at the edge of many species distributions but documentation of climate change as a cause of extirpation and fragmentation of the interior of a species’ core habitat has been lacking. Here in this paper, we report the extirpation of the American pika (Ochotona princeps), a temperature-sensitive small mammal, from a 165-km 2 area located within its core habitat in California’s Sierra Nevada mountains. While sites surrounding the area still maintain pikas, radiocarbon analyses of pika fecal pellets recovered within this area indicate that former patch occupancy ranges from before 1955, the beginning of the atmospheric spike in radiocarbon associated with above ground atomic bomb testing, to c. 1991. Despite an abundance of suitable rocky habitat climate warming appears to have precipitated their demise. Weather station data reveal a 1.9°C rise in local temperature and a significant decline in snowpack over the period of record, 1910–2015, pushing pika habitat into increasingly tenuous climate conditions during the period of extirpation. This is among the first accounts of an apparently climate-mediated, modern extirpation of a species from an interior portion of its geographic distribution, resulting in habitat fragmentation, and is the largest area yet reported for a modern-era pika extirpation. Our finding provides empirical support to model projections, indicating that even core areas of species habitat are vulnerable to climate change within a timeframe of decades.

54 ENVIRONMENTAL SCIENCES↗

Impact Sensitivity and Ignition Mechanisms of Nanoaluminum-poly(perfluorinated methacrylate) Nanocomposites

Nanoenergetic composites are of overwhelming interest to the Department of Defense because of the higher power output and the ability to finely tune the ignition thresholds of these composites. Recently, several variants of a nanoaluminum-poly(perfluorinated methacrylate) (AlFA) have been synthesized and optimized for a variety of applications including reactive warhead liners and bullet spotters. While conventional techniques such as thermal analysis and bomb calorimetry can be used to characterize the reaction mechanism and energy output of AlFA composites, characterizing their dynamic behaviour is more challenging. Bullet spotter applications require a material to be impact sensitive at very low velocities, yet be adequately insensitive. Several live-fire tests were conducted which revealed the AlFA 50 material reacted consistently upon target impact at high velocities, but unreliably at very low velocities. In an effort to better understand the fundamental impact ignition mechanism and to determine the impact velocity threshold of AlFA 50 a series of Taylor gas gun experiments were conducted. It was determined that the light-initiation mechanism was consistent with a pinch mechanism, and that the ignition velocity threshold was near 74 m/s. Based on these results, it was hypothesized that the addition of a filler material could be used to sensitize the AlFA 50 , and that Asay shear impact testing could be used to determine a more optimal shape of such inclusions. Experiments performed using the Asay shear impact test setup confirmed the pinch ignition mechanism, but observations also revealed that the size of the pinch point was important. It was shown that the addition of large glass beads (> 1mm in diameter) was effective at sensitizing the AlFA 50 material at high and low velocities, with ignition observed at impact velocities as low as 35 m/s.

36 MATERIALS SCIENCE↗

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation at Different Fetal Stages Results in Different Translocation Frequencies in Adult Mouse Thyroid Cells

While it is generally believed that fetuses are at high risk of developing cancers, including leukemia, after low doses of radiation, it has been reported that atomic bomb survivors exposed in utero did not show a dose response for translocations in blood T lymphocytes when they were examined at approximately 40 years of age. Subsequent mouse studies confirmed that animals irradiated during the fetal stage did not show evidence of radiation effects in lymphocytes and bone marrow cells when they were examined after reaching adulthood. However, in a study of rat mammary epithelial cells, radiation effects were clearly observed after fetal irradiation. These results indicate that the fate of chromosome aberrations induced in a fetus could vary among different tissues. Here we report on translocation frequencies in mouse thyroid cells, which were irradiated at different stages of fetal development. Cytogenetic examination was then conducted using fluorescence in situ hybridization (FISH) painting of chromosomes 1 and 3. Adult mice, 2 Gy X-ray irradiated at 15.5-day-old fetuses (E15.5), showed a higher translocation frequency (30/1,155 or 25.3 x 10 -3 ) than nonirradiated adult controls (0/1,007 or 0.1 x 10 -3 ), and was near that experienced by irradiated mothers and non-pregnant adult females (43/1,244 or 33.7 x 10 -3 ). These results are consistent with those seen in rat mammary cells. However, when fetuses were irradiated at an earlier stage of development (E6.5) before thyroid organogenesis, the resulting observed translocation frequency was much lower (3/502 or 5.8 x 10 -3 ) than that in E15.5 mice. These results suggest that after fetal irradiation, tissue stem cells record radiation effects primarily when the exposure occurs in cells that have been integrated into tissue. Embryonic stem cells that have been damaged prior to integration into the niche may undergo negative selection due to apoptosis, mitotic death or stem cell-niche cell interactions. The implications of these results in interpreting cancer risks after fetal irradiation are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Preface to the Focus Section on North Korea’s September 2017 Nuclear Test and Its Aftermath

On September 3, 2017 a large seismic event was detected near the Punggye-ri nuclear test site in North Korea (officially known as the Democratic People Republic of Korea or DPRK) by several geophysical monitoring institutions (for example, the USGS announced it as mb 6.3 event, the CTBTO announced it as a mb 6.1 event). Within a few hours North Korea declared it had carried out its sixth underground nuclear explosion, a test of a hydrogen bomb.

58 GEOSCIENCES↗

Best Practices for the Security of Radioactive Materials

This work is funded under a grant provided by the US Department of Health and Human Services, Centers for Disease Control. The Department of Health and Mental Hygiene (DOHMH) awarded a contract to Brookhaven National Laboratory (BNL) to develop best practices guidance for Office of Radiological Health (ORH) licensees to increase on-site security to deter and prevent theft of radioactive materials (RAM). The purpose of this document is to describe best practices available to manage the security of radioactive materials in medical centers, hospitals, and research facilities. There are thousands of such facilities in the United States, and recent studies suggest that these materials may be vulnerable to theft or sabotage. Their malevolent use in a radiological-dispersion device (RDD), viz., a dirty bomb, can have severe environmental- and economic- impacts, the associated area denial, and potentially large cleanup costs, as well as other effects on the licensees and the public. These issues are important to all Nuclear Regulatory Commission and Agreement State licensees, and to the general public. This document outlines approaches for the licensees possessing these materials to undertake security audits to identify vulnerabilities in how these materials are stored or used, and to describe best practices to upgrade or enhance their security. Best practices can be described as the most efficient (least amount of effort/cost) and effective (best results) way of accomplishing a task and meeting an objective, based on repeatable procedures that have proven themselves over time for many people and circumstances. Best practices within the security industry include information security, personnel security, administrative security, and physical security. Each discipline within the security industry has its own 'best practices' that have evolved over time into common ones. With respect to radiological devices and radioactive-materials security, industry best practices encompass both physical security (hardware and engineering) and administrative procedures. Security regimes for these devices and materials typically use a defense-in-depth- or layered-security approach to eliminate single points of failure. The Department of Energy, the Department of Homeland Security, the Department of Defense, the American Society of Industrial Security (ASIS), the Security Industry Association (SIA) and Underwriters Laboratory (UL) all rovide design guidance and hardware specifications. With a graded approach, a physical-security specialist can tailor an integrated security-management system in the most appropriate cost-effective manner to meet the regulatory and non-regulatory requirements of the licensee or client.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Monte Carlo Simulations for Homeland Security Using Anthropomorphic Phantoms

A radiological dispersion device (RDD) is a device which deliberately releases radioactive material for the purpose of causing terror or harm. In the event that a dirty bomb is detonated, there may be airborne radioactive material that can be inhaled as well as settle on an individuals leading to external contamination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Th Cell Gene Expression and Function in Response to Low Dose and Acute Radiation

Human low dose radiation data have been derived primarily from studies of space and airline flight personnel, nuclear plant workers and others exposed occupationally, as well as victims in the vicinity of atomic bomb explosions. The findings remain inconclusive due to population inconsistencies and complex interactions among total dose, dose rate, radiation quality and age at exposure. Thus, safe limits for low dose occupational irradiation are currently based on data obtained with doses far exceeding the levels expected for the general population and health risks have been largely extrapolated using the linear-nonthreshold dose-response model. The overall working hypothesis of the present study is that priming with low dose, low-linear energy transfer (LET) radiation can ameliorate the response to acute high-dose radiation exposure. We also propose that the efficacy of low-dose induced protection will be dependent upon the form and regimen of the high-dose exposure: photons versus protons versus simulated solar particle event protons (sSPE). The emphasis has been on gene expression and function of CD4+ T helper (Th) lymphocytes harvested from spleens of whole-body irradiated C57BL/6 mice, a strain that provides the genetic background for many genetically engineered strains. Evaluations of the responses of other selected cells, tissues such as skin, and organs such as lung, liver and brain were also initiated (partially funded by other sources). The long-term goal is to provide information that will be useful in estimating human health risks due to radiation that may occur during exposures in the work environment, nuclear/radiological catastrophes, as well as radiotherapy. Several papers have been published, accepted for publication or are in preparation. A number of poster and oral presentations have been made at scientific conferences and workshops. Archived tissues of various types will continue to be evaluated via funding from other sources (the DoE Low Dose Radiation Research Program, Office of Science and this specific grant will be appropriately included in the Acknowledgements of all subsequent publications/presentations). A post-doc and several students have participated in this study. More detailed description of the accomplishments is described below.

59 BASIC BIOLOGICAL SCIENCES↗

2012 SARA Students Technical Report

The Service Academy Research Associates (SARA) program provides an opportunity for Midshipmen and Cadets from US Service Academies to participate in research at Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratory for several weeks during the summer as part of their summer training assignments. During the summer of 2012, three Midshipmen were assigned to work with the XCP Division at LANL for approximately 5-6 weeks. As one of the nation's top national security science laboratories, LANL stretches across 36 square miles, has over 2,100 facilities, and employs over 9,000 individuals including a significant number of students and postdocs. LANL's mission is to 'apply science and technology to: ensure the safety, security, and reliability of the US nuclear deterrent, reduce global threats, and solve other emerging national security challenges.' While LANL officially operates under the US Department of Energy (DoE), fulfilling this mission requires mutual cooperation with the US Department of Defense (DoD) as well. LANL's high concentration of knowledge and experience provides interns a chance to perform research in many disciplines, and its connection with the DoD in both operation and personnel gives SARA students insight to career possibilities both during and after military service. SARA students have plenty of opportunity to enjoy hiking, camping, the Los Alamos YMCA, and many other outdoor activities in New Mexico while staying at the Buffalo Thunder Resort, located 20 miles east of the lab. XCP Division is the Computational Physics division of LANL's Weapons Department. Working with XCP Division requires individuals to be Q cleared by the DoE. This means it is significantly more convenient for SARA students to be assigned to XCP Division than their civilian counterparts as the DoD CNWDI clearance held by SARA students is easily transferred to the lab prior to the students arriving at the start of the summer. SARA students working with XCP Division were given a comprehensive introduction into nuclear engineering and physics, nuclear weapons, and radiation transport and detection via texts and lectures at various classification levels. Students also attended tours of several prominent facilities at LANL including TA-41 Ice House, TA-55 PF-4 plutonium facility, the Nicholas C. Metropolis Center for Modeling and Simulation, also known as the Secure Computing Center (SCC), and the Dual-Axis Radiological Hydro Test (DARHT) facility; in addition, SARA students accompanied by LANL staff traveled to Minot AFB in North Dakota for tours of the 5th Bomb Wing and 91st Missile Wing facilities. Students participated in a week long class on the Monte Carlo N Particle (MCNP) code to supplement their understanding of radiation transport simulations. SARA students were then tasked with using this knowledge to model radiation detectors and use MCNP to compare their models to experimental data and previously accepted models.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗